product image
Emerson 3-Phase Ups In Manesar

Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues. Key Features of Emerson 3-Phase UPS: Power Capacity: 3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model. Suitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings. Technology: Double Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging. Efficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs. Battery Management: Integrated advanced battery management for monitoring health, charge, and backup times. High Availability: Designed to provide reliable power for mission-critical applications. Hot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply. Scalability: Many models allow for modular expansion, meaning you can add additional capacity as needed. Input/Output Voltage: Input Voltage: Common input voltages are 380V, 400V, and 415V (3-phase). Output Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards. Power Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency. Advanced Features: LCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring. Remote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics. Bypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime. Design and Durability: Compact Design: Many models are designed to be space-efficient without compromising on power or cooling needs. Rack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs. Thermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating. Applications: Data Centers: Ensures uptime for servers and networking equipment. Industrial Equipment: Protects critical machinery and automated systems from power failures. Telecommunications: Keeps communication systems running without interruption. Hospitals: Supports life-saving equipment and systems that require constant power. Commercial Buildings: Ensures backup power for office systems and equipment. Maintenance and Service: Smart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required. Serviceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition. Proactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations. Popular Models: Emerson (now part of Vertiv) offers various UPS models under different series, such as: Vertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications. Vertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability. Vertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications. Advantages of Emerson 3-Phase UPS: High Reliability: Ensures critical equipment remains powered during power failures or fluctuations. Advanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility. Energy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact. Scalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand. Conclusion: Emerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.

Send Message
product image
Vertiv Three Phase Online Ups

The Vertiv Online UPS systems offer a range of three-phase solutions designed for critical power applications. Here are some key models and their specifications: 1. Liebert EXS Power Rating: Up to 20 kVA Output Configuration: Configurable for three-phase (3/3) or single-phase (3/1) output Flexibility: On-site configuration allows adaptation to changing power needs Efficiency: High efficiency with double conversion technology Applications: Suitable for data centers and critical IT infrastructure 2. Liebert ITA2 Power Rating: Up to 10 kVA Design: Available in rackmount or tower configurations Reliability: Economical and efficient three-phase power for critical loads Features: High power factor and compact design 3. Liebert NX Power Rating: 40-200 kVA Scalability: Allows growth from 40 to 60 to 80 kVA, and from 80 to 100 to 120 kVA Parallel Operation: Can be paralleled for additional capacity or redundancy Efficiency: Designed for high efficiency and reliability 4. Vertiv Trinergy Power Rating: 1500-2500 kW Modular Design: High-capacity modular UPS for large applications Reliability: Maximized reliability with advanced features for critical systems 5. Liebert NXL Power Rating: Up to 800 kW Input Voltage: 480VAC, three-phase, three-wire Load Voltage: 480VAC, three-phase, three-wire in and out or four-wire in Applications: Ideal for large data centers and mission-critical environments General Features Across Models Double Conversion Technology: Ensures continuous power conditioning and protection against power disturbances High Efficiency: Designed to minimize energy costs while maximizing performance Advanced Monitoring: Many models include LCD displays for real-time monitoring and diagnostics Flexible Configurations: Options for tower or rackmount installations to suit various environments Conclusion Vertiv\'s three-phase UPS systems provide robust and reliable power protection for critical applications, ensuring the availability and integrity of essential systems in data centers and other mission-critical environments.

Send Message
product image
3kva ups

The Vertiv 3kVA online UPS is a reliable power solution designed for critical applications. Here are its key features and specifications: Key Features: True double conversion online UPS technology for high-quality power output Compact tower design for reduced footprint and increased reliability Eco mode for high efficiency and reduced total cost of ownership (TCO) Intelligent monitoring and network management capabilities for enhanced system shutdown and control Scalable runtime options with matching external battery cabinets for extended backup time Specifications: Capacity: 3kVA Type: Double Conversion Online UPS Volts: 230V AC (single-phase) Power Factor: 0.9 Efficiency: Up to 95% Input Voltage Range: 180-280V AC (single-phase) Output Voltage: 230V AC (single-phase) Frequency: 50/60 Hz Battery Type: Valve Regulated Lead Acid (VRLA) Battery Capacity: Up to 12Ah Battery Life: Up to 5 years Dimensions: 440 x 220 x 640 mm (H x W x D) Weight: Approximately 30 kg Applications: Small to medium-sized data centers Network operation centers Server rooms Telecommunication systems Medical equipment Industrial control systems Security systems Building management systems Benefits: High-quality power output Compact design High efficiency Scalable runtime options Intelligent monitoring and network management capabilities Warranty and Support: Warranty period: Up to 3 years Customer support: Available from the manufacturer and authorized dealers

Send Message
product image
Vertiv 30 KVA Online UPS

The Vertiv 30 KVA Online UPS is designed for high availability and reliability in critical power applications. Here are the key details: Specifications Power Rating: 30 KVA (27 kW) capacity. Input Voltage: Typically 380-480 V AC (three-phase). Output Voltage: Configurable, commonly 220/230/240 V AC (three-phase). Frequency: 50/60 Hz. Topology: Online Double-Conversion for continuous power conditioning. Output Waveform: Pure sine wave. Battery Type: Lead-acid or lithium-ion options available. Battery Runtime: Varies by load; external battery packs can extend runtime. Charging Time: Full recharge time is typically 4-8 hours. Cooling Method: Air-cooled with internal fans. Dimensions: Generally rack-mountable or floor-standing, with dimensions varying by model. Weight: Usually ranges from 150 to 300 kg, depending on the configuration. Features LCD Display: Provides real-time monitoring of system status, battery levels, and load. Multiple Outlets: Various outlet types for flexibility in connectivity. Smart Battery Management: Enhances battery life and performance. Surge Protection: Protects against voltage spikes and surges. Remote Monitoring: Options for SNMP, USB, or serial communication for remote management. Maintenance Bypass: Allows for safe maintenance without power interruptions. Modularity: Options for scalable solutions and additional battery units. Applications Data Centers Telecommunications Industrial Applications IT Infrastructure Medical Equipment Maintenance Regular maintenance is crucial for performance, including: Periodic battery checks and replacements. Cleaning of vents and fans. Load testing to ensure reliability.

Send Message
product image
Eaton 9395P UPS

The Eaton 9395P UPS is a high-performance uninterruptible power supply designed for critical applications. It features a three-phase online design with power ratings ranging from 250 to 1200 kVA, utilizing advanced technology for high efficiency and scalability. Key Specifications Power Ratings: 250-1200 kVA Input Voltage: Typically 480V, with options for 400V or 600V Efficiency: High double conversion efficiency with reduced energy losses Battery Types: Supports VRLA, AGM, and wet cell batteries Overload Capacity: 110% for 10 minutes, 125% for 2 minutes, 150% for 15 seconds Display: 7” or 10” touchscreen for monitoring and control Features Modular Design: Allows for easy scalability and maintenance. Advanced Monitoring: Provides real-time data and alerts for optimal performance. Compact Footprint: Designed to maximize power density in limited spaces. Applications Ideal for data centers, telecommunications, and industrial environments where reliable power is critical. For more detailed specifications, you can refer to the official Eaton documentation. ### Additional Features Energy Saver System (ESS): Achieves up to 99% efficiency, significantly reducing operational costs. Three-Level Converter Design: Reduces stress on components, extending their lifespan and reliability. Heat Reduction: Produces 33% less heat, leading to lower HVAC costs. Increased Power Density: Offers up to 20% more power in the same footprint compared to previous models. Redundancy: Modular design ensures inherent redundancy, preventing dropped loads. Battery Information Battery System: External battery systems are used, with options for lead-acid or lithium batteries. Batteries Included: Typically, batteries are not included and must be purchased separately. Lead Time Availability: Estimated lead time for delivery is 20+ weeks, depending on configuration and order specifics. Target Markets Enterprise Data Centers: Provides robust power protection for critical IT infrastructure. Colocation Facilities: Supports multiple clients with varying power needs. Server Farms and Telecommunications: Ensures uptime for essential services and applications. Healthcare and Financial Systems: Protects sensitive equipment and data from power interruptions. Conclusion The Eaton 9395P UPS is engineered for high efficiency and reliability, making it an excellent choice for organizations that require uninterrupted power supply. Its modular design, advanced features, and scalability cater to a wide range of applications, ensuring that critical systems remain operational during power disturbances. For further details, consult the official Eaton website or authorized distributors.

Send Message
product image
UPS

Vertiv offers the 30kVA UPS models designed for high availability and critical power applications. Here’s a detailed overview of the key features and specifications: Key Model: 1. Vertiv Liebert EXS UPS: Power Rating: 30kVA / 30k - Input/Output Voltage: 400V in / 400V out, three-phase Technology: Online double conversion for superior power quality Power Factor: High power factor (0.9) for efficient energy usage Form Factor: Rack-mounted or tower configuration Features: Modular Design: Allows for easy scalability and maintenance without downtime Advanced Monitoring: Integrated monitoring capabilities with the Vertiv monitoring platform for real-time insights Battery Management: Intelligent battery management system to optimize battery life and performance User -Friendly Interface: Touchscreen display for easy navigation and monitoring of UPS status Energy Efficiency: Designed to meet or exceed ENERGY STAR certification for energy savings Applications: Data Centers: Provides reliable power to critical IT infrastructure Healthcare Facilities: Ensures uninterrupted power for life-saving medical equipment Telecommunications: Supports network operations and communications during power failures Industrial Applications: Protects sensitive equipment and processes from power disturbances Technical Specifications: Input Connection Types: IEC 320 EN 60320 C19, IEC 60320 C13 Output Connection Types: 6 x IEC 60320 C19, 2 x IEC 60320 C13 Operating Environment: Suitable for both indoor and outdoor installations, with temperature and humidity controls Advantages: High Availability: Designed for maximum uptime and reliability in critical applications Flexible Configuration: Can be customized to meet specific power requirements and installation environments Robust Protection: Offers comprehensive protection against power anomalies, ensuring equipment safety Vertiv\'s 30kVA UPS solutions are engineered to deliver reliable power protection and management, ensuring operational continuity and efficiency in demanding environments.

Send Message
product image
Vertiv Online Ups

Vertiv offers a range of online UPS (Uninterruptible Power Supply) systems designed to provide reliable power protection for critical applications, including data centers, telecommunications, and industrial environments. Here’s a detailed overview of Vertiv's online UPS solutions, including key features, specifications, benefits, and maintenance practices. Vertiv Online UPS Overview Purpose: Online UPS systems are designed to ensure continuous and clean power supply by converting incoming AC power to DC and then back to AC. This process provides maximum protection against power disturbances such as surges, sags, and outages. Key Features Continuous Power Supply: Provides uninterrupted power during outages, ensuring that sensitive equipment remains operational. Double-Conversion Technology: Converts incoming AC to DC and back to AC, delivering stable and high-quality power output. High Efficiency: Many models boast efficiencies of 95% or higher, particularly in eco-mode, reducing energy costs. Scalability: Options for parallel operation allow for easy scaling of capacity by adding additional units. Advanced Battery Management: Features for monitoring battery health, optimizing performance, and extending battery life, including temperature and state of charge monitoring. User-Friendly Interface: LCD or LED displays provide real-time data on power status, battery health, and load levels. Network Management Capabilities: Integration with remote monitoring systems through SNMP, allowing for proactive management and alerts. Vibration and Shock Resistance: Designed to withstand harsh operating conditions, making them suitable for industrial environments. Flexible Input/Output Options: Supports various voltages and phases, accommodating different application requirements. Specifications (Typical) Input Voltage: 380/400/415 V (three-phase), with some models supporting single-phase. Output Voltage: 380/400/415 V (three-phase). Output Frequency: 50/60 Hz (auto-sensing). Capacity Range: Varies widely, from small systems (1 kVA) to large systems (up to 500 kVA or more). Efficiency: Typically 95% to 98%, depending on model and operating conditions. Form Factor: Available in tower or rack-mounted configurations. Benefits Reliability: Provides a stable power supply, protecting sensitive equipment from power disturbances. Improved Power Quality: Filters out electrical noise and provides clean power, which is crucial for IT and telecommunications equipment. Cost Savings: High efficiency reduces operational costs, and predictive maintenance can prevent costly downtime. Robust Performance: Designed for heavy loads and capable of maintaining performance under varying conditions. Remote Monitoring: Enables proactive management and quick response to potential issues, enhancing system reliability. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Includes cleaning, tightening connections, and replacing worn-out components as necessary. Battery Management: Monitor battery health, conduct load tests, and replace batteries according to manufacturer guidelines. Documentation: Maintain records of inspections, tests, and repairs to track system performance over time. Professional Support: Engage professional services for emergency repairs, technical support, and routine maintenance. Conclusion Vertiv's online UPS systems provide critical power protection for a variety of applications. With their advanced features, high efficiency, and robust design, they are ideal for ensuring reliable power in environments where uptime is essential. Proper maintenance and proactive management are key to maximizing performance and longevity. If you need more specific information about particular models, configurations, or any other aspect, feel free to ask!

Send Message
product image
Vertiv 30Kva Ups

The Vertiv 30 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection for critical applications in various environments, such as data centers, telecommunications, and industrial settings. Here’s a comprehensive overview of its features, specifications, and benefits: Vertiv 30 kVA UPS Overview Key Features Power Capacity: 30 kVA output, suitable for medium-sized systems. Topologies: Typically available in both online double-conversion and line-interactive designs, ensuring maximum protection against power disturbances. High Efficiency: Energy-efficient operation, often with advanced features to minimize energy consumption, especially in low-load scenarios. Modular Design: Some models may offer a modular design for easy scalability, allowing for future expansions without significant infrastructure changes. Flexible Input and Output Options: Compatible with various input voltages and offers different output configurations to accommodate various loads. Advanced Battery Management: Features for optimizing battery performance, including temperature monitoring, equalization charging, and predictive diagnostics. User-Friendly Interface: LCD or LED display for easy monitoring of status, battery health, and load levels. Network Management Capabilities: Integration with network management systems for remote monitoring and control, often through SNMP or web interfaces. Parallel Operation: Capability to operate multiple units in parallel for increased redundancy and capacity. Specifications (Typical) Input Voltage: 380/400/415 V (Three-phase) Output Voltage: 380/400/415 V (Three-phase) Output Frequency: 50/60 Hz (Auto-sensing) Efficiency: Up to 95% or higher in online mode. Form Factor: Tower or rack-mounted options depending on the model. Batteries: Lead-acid or lithium-ion options depending on configuration. Benefits Reliability: Ensures continuous power supply and protects against all power disturbances. Scalability: Easily add capacity as your needs grow, especially with modular options. Cost Savings: High efficiency reduces energy costs, and predictive maintenance can prevent costly downtime. Enhanced Performance: Maintains stable output voltage and frequency, protecting sensitive equipment. Remote Monitoring: Allows for proactive management and maintenance, minimizing potential issues. Maintenance and Support Annual Maintenance Contracts (AMC): Regular inspections, preventive maintenance, and emergency support can help ensure optimal performance and reliability. Battery Replacement: Scheduled battery replacements as per usage and manufacturer guidelines are crucial for longevity and performance. Conclusion The Vertiv 30 kVA UPS is a robust solution for critical power needs, combining efficiency, reliability, and advanced management features. Whether for a data center, telecommunications, or other mission-critical applications, it provides essential protection against power interruptions. If you need specific model numbers, configuration options, or pricing information, let me know!

Send Message
product image
UPS

The Emerson/Vertiv 1kVA UPS is a single-phase uninterruptible power supply solution that offers premium power outage protection and continuous power conditioning. It has a true online double conversion topology, ensuring high reliability and efficiency. Technical Specifications **Brand **: Emerson/Vertiv Model Name/Number: 1kVA UPS Capacity: 1kVA/ 0.8KW (1in - 1out) Input Voltage: 140-300VAC at 100% load; 100VAC - 300VAC on 50% load Output Voltage: 230VAC (single phase) Application Areas Small to Medium-Sized Businesses Home Offices Small Server Rooms Point of Sale (POS) Systems ATMs Medical Equipment Security Systems Telecom Reliability in a Compact Footprint Fully-digital control with high output voltage precision Manages all the nine power problems including sagging, spikes, and fluctuations Built-in Ethernet port includes compatibility with intelligent cards (SIC card, RDU_SIC cards, etc.,) with browser support Built-in-power charger for fast charging reduces battery charging time Prolonged backup time through cascaded connection

Send Message