Liebert Series 610 On-line UPS In Patparganj Delhi

The Liebert Series 610 On-line UPS is a true double-conversion online UPS designed for large facilities, offering a high level of reliability and flexibility. Here are its key specifications and features: Specifications: Power Rating: 225k VA to 600kVA Input Voltage: 380V to 480V AC Output Voltage: 380V to 480V AC Frequency: 50/60 Hz Efficiency: Up to 94% Battery Type: Valve-Regulated Lead-Acid (VRLA) Battery Capacity: Up to 40 minutes at full load Dimensions: Varies by model Weight: Varies by model Features: High Efficiency: Up to 94% efficiency, reducing heat output and energy costs Flexibility: Modular design allows for easy expansion and customization Reliability: True double-conversion online UPS design provides high reliability and fault tolerance Scalability: Supports large facilities with high power requirements Low Heat Output: Reduces the need for complex cooling arrangements Higher DC Bus Utilization: Provides higher AC/AC and DC/AC efficiency and allows for a relatively smaller battery Applications: Enterprise Data Centers: Provides reliable power protection for large data centers Colocation/Hosting: Supports high-density colocation and hosting facilities Services: Engineering: Customized engineering services for UPS system design and implementation Installation: Professional installation services for UPS systems Preventative Maintenance: Regular maintenance services to ensure UPS system reliability Monitoring: Real-time monitoring services for UPS system performance Recycling: Environmentally responsible recycling services for UPS batteries and equipment Certifications: ISO 9001: Quality management system certification ISO 14001: Environmental management system certification ISO 45001: Occupational health and safety management system certification

Send Message
product image
UPS

overview of the Vertiv 1000 kVA UPS, focusing on its features, specifications, and applications. General Overview Type: Online UPS (Double-Conversion) Capacity: 1000 kVA (1 MVA) Form Factor: Typically floor-mounted, designed for large facilities. Electrical Specifications Input Voltage: Usually 380V to 480V AC, three-phase Output Voltage: Configurable output, typically 380V to 480V AC Frequency: 50/60 Hz (auto-sensing) Output Power Factor: Typically around 0.9 to 1.0 Performance Efficiency: High efficiency, often exceeding 95%, with options for eco-mode to enhance energy savings. Transfer Time: Zero milliseconds due to the online architecture, ensuring uninterrupted power supply. Battery and Runtime Battery Type: Commonly uses sealed lead-acid (SLA) or lithium-ion batteries. Battery Backup Time: Varies based on load; external battery cabinets can extend runtime. Recharge Time: Typically 4-8 hours to recharge from complete discharge. Features User Interface: LCD display with real-time monitoring of operational status, battery health, load levels, and alarms. Communication Ports: SNMP, USB, and RS-232 for monitoring and remote management. Surge Protection: Built-in surge protection to safeguard connected equipment. Overload Protection: Automatic shutdown in case of overload conditions. Physical Specifications Dimensions: Size varies by model; requires substantial floor space and proper ventilation. Weight: Generally heavy; ensure appropriate installation support. Installation and Management Mounting Options: Designed for floor mounting; requires sufficient space and infrastructure. Management Software: Advanced software options for monitoring and managing UPS status remotely. Applications Ideal for: Data centers Large IT infrastructures Industrial applications Telecommunications Healthcare facilities Additional Features Modularity: Some models may offer modular designs for scalability and redundancy. Hot-Swap Capability: Allows battery replacement and maintenance without downtime. Parallel Operation: Supports parallel configurations for redundancy and capacity scaling. Warranty and Support Warranty: Generally includes a limited warranty covering parts and labor, with options for extended service agreements. Support: Vertiv offers various support services, including installation, maintenance, and monitoring solutions. Conclusion The Vertiv 1000 kVA UPS is designed for mission-critical applications requiring high reliability and performance. It is well-suited for environments where power continuity is essential.

Send Message
product image
VERTIV 175 TO 200 KVA ONLINE UPS IN SECTOR 82 NOIDA

overview of the Vertiv UPS models in the 175 kVA to 200 kVA range, focusing on features, specifications, and applications. General Overview Type: Online UPS (Double-Conversion) Capacity: 175 kVA to 200 kVA Form Factor: Typically available in a floor-standing configuration Electrical Specifications Input Voltage: Typically 380V to 480V AC three-phase Output Voltage: 380V to 480V AC (configurable based on application) Frequency: 50/60 Hz (auto-sensing) Output Power Factor: Usually around 0.9 to 1.0 Performance Efficiency: High efficiency, often exceeding 95% in normal operating mode, with some models offering an eco-mode for even greater energy savings. Transfer Time: Zero milliseconds due to the online architecture. Battery and Runtime Battery Type: Typically uses sealed lead-acid (SLA) or lithium-ion batteries. Battery Backup Time: Varies based on load; options for extended runtime through external battery cabinets. Recharge Time: Generally 4-8 hours to recharge from complete discharge, depending on configuration. Features LCD Display: Advanced display panel providing real-time information on operational status, battery health, load percentage, and alarms. Communication Ports: Options typically include USB, RS-232, and SNMP for monitoring and management. Surge Protection: Built-in surge protection to safeguard equipment. Overload Protection: Automatic shutdown in case of overload situations. Physical Specifications Dimensions: Varies by model; typically requires dedicated floor space. Weight: Generally heavy; ensure proper installation and support infrastructure. Installation and Management Mounting Options: Floor-mounted; requires adequate space and ventilation. Management Software: Advanced management and monitoring software available, allowing for remote control and status checks. Applications Ideal for: Data centers Critical IT infrastructure Telecommunications Industrial applications Healthcare facilities Additional Features Modularity: Some models offer modular design for scalability. Hot-Swap Capability: Allows for battery maintenance without downtime. Redundancy Options: Parallel operation capability for enhanced reliability. Warranty and Support Warranty: Typically includes a limited period covering parts and labor, with options for extended service agreements. Support: Vertiv provides various support services, including installation, maintenance, and remote monitoring. Conclusion The Vertiv UPS in the 175 kVA to 200 kVA range is designed for robust applications that require high reliability and performance. These systems are ideal for environments where uptime is critical.

Send Message
product image
Emerson 40kVA Online UPS

The Emerson 40kVA Online UPS is a high-capacity uninterruptible power supply designed for critical applications where power reliability is essential. Here are the detailed specifications and features typically associated with this UPS model: Specifications Capacity: 40 kVA (kilovolt-amps) Input Voltage: Typically operates within a range of 380V to 480V AC. Output Voltage: Provides stable output, usually around 400V or 415V AC. Output Waveform: Pure sine wave output to ensure compatibility with sensitive electronic equipment. Input Frequency: Generally supports 50/60 Hz auto-sensing. Features Online Double-Conversion Technology: Ensures continuous power supply by converting incoming AC to DC and then back to AC, effectively isolating the load from power disturbances. LCD Display: Provides real-time information on operational status, including input/output voltage, battery status, and load percentage. Battery Type: Usually uses sealed lead-acid or lithium-ion batteries, depending on the specific model configuration. Charging Time: Full charge time can range from 4 to 8 hours, depending on battery type and condition. Runtime: Varies based on load; configurations can provide backup for several minutes to hours. Protection Features Overload Protection: Automatically shuts down the UPS to prevent damage if the load exceeds the rated capacity. Short-Circuit Protection: Protects against potential damage due to short circuits. Surge Protection: Guards connected equipment from voltage spikes and transients. Thermal Management: Equipped with fans and temperature sensors to prevent overheating. Connectivity Output Sockets: Multiple outlets for connecting various devices, often including hardwired connections. Communication Ports: USB, RS232, and SNMP options for remote monitoring and management. Parallel Operation: Supports multiple UPS units to work together for enhanced capacity and redundancy. Applications Suitable for: Data centers Telecommunications Industrial applications Medical equipment Critical IT infrastructure Installation & Maintenance Installation: Typically requires professional installation due to its size and complexity. Maintenance: Regular maintenance checks are essential for battery health and overall system performance. Warranty Often includes a manufacturer’s warranty, typically ranging from 1 to 3 years, depending on the model and specific terms.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Battery Replacement In Faridabad

Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each. Types of Batteries and Their Replacement Process 1. Lead-Acid Batteries Common Types: Flooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells. Sealed Lead-Acid (SLA): Maintenance-free and does not require water addition. Absorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats. Gel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications. Replacement Process: Turn off the system: Ensure the system is powered off, and disconnect it from the grid or load. Safety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases. Disconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal. Remove old batteries: Lift and remove the batteries carefully, especially if they're heavy. Clean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water. Install new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal. Check the system: Power on the system and check the voltage and charging status. Maintenance Tips: Regularly check the electrolyte levels in flooded batteries. Clean terminals and ensure the battery box or tray is secure. 2. Lithium-Ion Batteries Common Types: Lithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan. Lithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools. Lithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications. Lithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones. Replacement Process: Turn off the system: Disconnect the power source or system. Safety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage. Disconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal. Remove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries. Install the new battery: Place the new battery in the same orientation and secure it. Reconnect terminals: Attach the positive terminal first, followed by the negative terminal. Check the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly. Maintenance Tips: Lithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range. Battery Management System (BMS) should be monitored to ensure proper functioning and safety. Conclusion: Battery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation. Lead-acid batteries need regular maintenance, especially flooded types. Lithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance. Always follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.

Send Message
product image
Emerson 3-Phase Ups In Manesar

Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues. Key Features of Emerson 3-Phase UPS: Power Capacity: 3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model. Suitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings. Technology: Double Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging. Efficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs. Battery Management: Integrated advanced battery management for monitoring health, charge, and backup times. High Availability: Designed to provide reliable power for mission-critical applications. Hot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply. Scalability: Many models allow for modular expansion, meaning you can add additional capacity as needed. Input/Output Voltage: Input Voltage: Common input voltages are 380V, 400V, and 415V (3-phase). Output Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards. Power Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency. Advanced Features: LCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring. Remote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics. Bypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime. Design and Durability: Compact Design: Many models are designed to be space-efficient without compromising on power or cooling needs. Rack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs. Thermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating. Applications: Data Centers: Ensures uptime for servers and networking equipment. Industrial Equipment: Protects critical machinery and automated systems from power failures. Telecommunications: Keeps communication systems running without interruption. Hospitals: Supports life-saving equipment and systems that require constant power. Commercial Buildings: Ensures backup power for office systems and equipment. Maintenance and Service: Smart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required. Serviceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition. Proactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations. Popular Models: Emerson (now part of Vertiv) offers various UPS models under different series, such as: Vertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications. Vertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability. Vertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications. Advantages of Emerson 3-Phase UPS: High Reliability: Ensures critical equipment remains powered during power failures or fluctuations. Advanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility. Energy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact. Scalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand. Conclusion: Emerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.

Send Message
product image
Vertiv Powerbank

The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency. Key Specifications Model: Liebert Powerbank 600 Capacity: 600 kVA Input Voltage: Typically supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Form Factor: Modular design for easy scalability Efficiency: High efficiency, often exceeding 95% in double conversion mode Features Modular Design: Allows for easy expansion and maintenance, enabling users to add or replace modules as needed. High Availability: Designed for redundancy and reliability, ensuring continuous power supply to critical loads. Advanced Monitoring: Equipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking. Flexible Configuration: Supports various configurations to meet specific power requirements and environmental conditions. Battery Management: Intelligent battery management features to optimize battery life and performance. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Compact Footprint: Designed to maximize power density in limited spaces, making it suitable for various installation environments. Applications Data Centers: Provides robust power protection for critical IT infrastructure. Telecommunications: Ensures uptime for communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Performance Metrics Input Frequency: Typically supports 50/60 Hz Output Power Factor: Generally rated at 0.9, allowing for efficient power delivery. Operating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius. Conclusion The Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
Eaton 9395P UPS

The Eaton 9395P UPS is a high-performance uninterruptible power supply designed for critical applications. It features a three-phase online design with power ratings ranging from 250 to 1200 kVA, utilizing advanced technology for high efficiency and scalability. Key Specifications Power Ratings: 250-1200 kVA Input Voltage: Typically 480V, with options for 400V or 600V Efficiency: High double conversion efficiency with reduced energy losses Battery Types: Supports VRLA, AGM, and wet cell batteries Overload Capacity: 110% for 10 minutes, 125% for 2 minutes, 150% for 15 seconds Display: 7” or 10” touchscreen for monitoring and control Features Modular Design: Allows for easy scalability and maintenance. Advanced Monitoring: Provides real-time data and alerts for optimal performance. Compact Footprint: Designed to maximize power density in limited spaces. Applications Ideal for data centers, telecommunications, and industrial environments where reliable power is critical. For more detailed specifications, you can refer to the official Eaton documentation. ### Additional Features Energy Saver System (ESS): Achieves up to 99% efficiency, significantly reducing operational costs. Three-Level Converter Design: Reduces stress on components, extending their lifespan and reliability. Heat Reduction: Produces 33% less heat, leading to lower HVAC costs. Increased Power Density: Offers up to 20% more power in the same footprint compared to previous models. Redundancy: Modular design ensures inherent redundancy, preventing dropped loads. Battery Information Battery System: External battery systems are used, with options for lead-acid or lithium batteries. Batteries Included: Typically, batteries are not included and must be purchased separately. Lead Time Availability: Estimated lead time for delivery is 20+ weeks, depending on configuration and order specifics. Target Markets Enterprise Data Centers: Provides robust power protection for critical IT infrastructure. Colocation Facilities: Supports multiple clients with varying power needs. Server Farms and Telecommunications: Ensures uptime for essential services and applications. Healthcare and Financial Systems: Protects sensitive equipment and data from power interruptions. Conclusion The Eaton 9395P UPS is engineered for high efficiency and reliability, making it an excellent choice for organizations that require uninterrupted power supply. Its modular design, advanced features, and scalability cater to a wide range of applications, ensuring that critical systems remain operational during power disturbances. For further details, consult the official Eaton website or authorized distributors.

Send Message