Bhiwadi
+918076792323

'50 test monthly'

Items tagged with '50 test monthly'

product image
Vertiv 500 kva Ups

The Vertiv 500 kVA UPS (Uninterruptible Power Supply) is a high-capacity power protection solution designed for industrial applications, data centers, and critical infrastructure. Here’s a detailed overview of its features, specifications, benefits, and maintenance practices. Vertiv 500 kVA UPS Overview Key Features High Power Capacity: Provides 500 kVA of power, suitable for large-scale applications requiring substantial backup power. Topologies: Online Double-Conversion: This design ensures continuous, clean, and stable power by converting incoming AC to DC and then back to AC, offering maximum protection against power disturbances. High Efficiency: Typically achieves efficiencies of 95% or higher, reducing energy consumption and operational costs. Scalability: Supports parallel operation with multiple units for increased redundancy and power capacity as your needs grow. Advanced Battery Management: Features for optimizing battery performance, including temperature monitoring, state of charge, and predictive diagnostics. User-Friendly Interface: LCD or LED displays provide real-time monitoring of power status, battery health, and load levels. Network Management Capabilities: Integration with network management systems for remote monitoring and control, often through SNMP or web interfaces. Vibration and Shock Resistance: Designed to withstand industrial environments, making it reliable for mission-critical applications. Multiple Input/Output Options: Flexible configurations to match various voltage and phase requirements. Specifications (Typical) Input Voltage: 380/400/415 V (Three-phase) Output Voltage: 380/400/415 V (Three-phase) Output Frequency: 50/60 Hz (auto-sensing) Efficiency: Up to 98% in eco mode. Dimensions: Varies by model; typically designed for rack or floor mounting. Weight: Can exceed 1000 kg, depending on configuration and battery type. Battery Types: Can support various battery technologies, including lead-acid and lithium-ion. Benefits Reliability: Ensures uninterrupted power supply and protects critical loads from power disturbances. Cost Savings: High efficiency leads to lower energy costs, while predictive maintenance helps avoid expensive downtimes. Enhanced Performance: Maintains stable output voltage and frequency, protecting sensitive equipment. Proactive Monitoring: Remote monitoring capabilities allow for early detection of potential issues, improving uptime and reliability. Robust Design: Built to withstand harsh industrial conditions, ensuring longevity and performance. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Cleaning, tightening connections, and replacing worn-out parts as needed. Battery Management: Monitor battery health, perform load tests, and replace batteries according to manufacturer guidelines. Documentation: Keep detailed records of maintenance, inspections, and performance metrics. Emergency Support: Engage professional services for emergency repairs and technical support when needed. Conclusion The Vertiv 500 kVA UPS is a robust solution designed for high-demand environments, ensuring reliable power protection for critical applications. With its advanced features and capabilities, it is ideal for data centers, industrial applications, and other mission-critical settings. Proper maintenance and proactive management can further enhance its performance and longevity. If you have specific questions or need additional details, feel free to ask!

Send Message
product image
12v 150ah

The Amaron Quanta 12V 150Ah battery is a Sealed Maintenance Free (SMF) VRLA (Valve Regulated Lead Acid) battery designed for UPS applications. It has a capacity of 150Ah and operates at 12 volts. The battery comes with a warranty of 24 months. Key Features: PPCP Containers with low permeability ensures that there is no water loss Lead Acid Storage Type @ C20 Rating Proven AGM technology ensures maintenance-free characteristics Reinforced end walls improve impact resistance Thicker grids and higher separator compression prolong life expectancy Inter cell weld between cells provide a high reliable, low resistance current path A unique heavy duty corrosion-resistant alloy for positive grids, to increase cyclic life in tropical environments Radgrid profile provides lower internal resistance and superior high discharge performance Instacharge a patented paste recipe for excellent charge acceptance Low self-discharge rates for extended storage periods Conforms to International standards – JIS8702C Design float life of 10 years Clean and Sleek looks Specifications: Capacity: 150Ah Type: SMF, VRLA (Sealed Maintenance Free, Valve Regulated Lead Acid) Volts: 12V Warranty: 24 months Weight: 46 kgs (approx.) Dimensions: 406168283 in mm (approx.) Applications: Data Centers Online UPS Inverter Systems Banks & Financial Markets Network Operation Centers Semiconductor Manufacturing Power Generation Plants Hospital & Testing Laboratories Portable Testing & Measuring Instruments Vending machines & Weighing Scales Office Automation Equipment Fire Alarm & Security Systems Electronic PABX Systems Telecommunication Systems Process Instrumentation & Control Railway Signalling Power Plants & Substations Benefits: High performance and reliability Low maintenance cost Long lifespan Environmentally friendly Warranty and Support: Warranty period: 24 months Customer support: Available from the manufacturer and authorized dealers

Send Message
product image
Battery Testing In Sonipat

Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details: Types of Tests: Voltage Test: Measures the battery's output voltage to check if it meets the specified range. Capacity Test: Assesses how much charge the battery can hold and deliver over time. Load Test: Simulates real-world usage to check how the battery performs under load. Internal Resistance Test: Evaluates the battery's internal resistance, indicating its health. Tools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers. Frequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures. Indicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage. Proper battery testing helps in proactive maintenance, ensuring reliability and safety.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
10 kW solar system installed at Parashuram Eye Hospital

10 kW solar Universal Power team has installed a 10 kW solar system at Parashuram Eye Hospital. Key Details of the 10 kW Solar System Installation: Solar Power Generation: A 10 kW system typically generates about 40-50 kWh per day, depending on the location and weather conditions. This translates to 14,600 to 18,250 kWh annually, which will help the hospital meet a significant portion of its energy needs. System Components: Solar Panels: Around 25-30 panels, each with a capacity of 330W-400W. Inverter: A 10 kW inverter is used to convert the DC electricity from the panels into AC electricity for hospital use. Mounting System: Panels are mounted on the roof or ground depending on the hospital's infrastructure. Grid Connection: The system is connected to the grid, allowing the hospital to export excess energy to the grid through net metering. Benefits for Parashuram Eye Hospital: Cost Reduction: The solar system will reduce the hospital's dependence on grid electricity, leading to lower monthly electricity bills. Sustainability: The hospital will be contributing to environmental sustainability by utilizing renewable energy, which helps reduce its carbon footprint. Energy Independence: The system ensures a reliable power source, especially during peak hours or grid outages. Maintenance: Solar panels require minimal maintenance, with periodic cleaning to ensure maximum efficiency. Lifespan: Solar panels typically last 25-30 years, and the inverter may need replacement after 10-15 years. Conclusion: The installation of a 10 kW on-grid solar power system at Parashuram Eye Hospital by Universal Power Team will provide long-term benefits in terms of cost savings, energy independence, and environmental impact. It’s an excellent step towards sustainable energy usage for the hospital. If you need more specific details about this installation, it would be best to contact Universal Power Team or the hospital directly.

Send Message
product image
Vertiv 10 Kva Ups

The Vertiv Liebert GXT MT LX (3 X 3) 10KVA UPS is a compact and reliable uninterruptible power supply designed for critical applications. It features best-in-class efficiency, robust protection, and simplified installation, making it suitable for commercial use. Key Specifications Power Rating: 10 KVA Phase: 3-phase, 4-wire Input Voltage: 400VAC Output Type: Online double conversion Warranty: 1 year Features High Efficiency: Offers excellent energy efficiency, reducing operational costs. Compact Design: Space-saving design ideal for various environments. Remote Monitoring: Capable of remote management for enhanced operational oversight. Applications Ideal for data centers, telecommunications, and other critical systems requiring uninterrupted power. For more detailed specifications, refer to the official Vertiv documentation. ### Additional Features True Online Double-Conversion: Provides continuous power supply and protects against power disturbances. DSP Processor: Utilizes the latest Digital Signal Processing technology for enhanced performance. Output Power Factor: Rated at 0.9, ensuring efficient power delivery. Active Input Power Factor Correction: Maintains efficiency across all phases. Frequency Converter Mode: Supports both 50 Hz and 60 Hz operations. ECO Mode Operation: Energy-saving mode that optimizes efficiency during low-load conditions. Emergency Power-Off Function (EPO): Allows for immediate shutdown in emergencies. Generator Compatibility: Designed to work seamlessly with generator systems. Multiple Communication Ports: Includes SNMP, USB, and RS-232 for versatile monitoring and management options. 3-Stage Extendable Charging Design: Optimizes battery performance and extends battery life. Adjustable Battery Numbers: Configurable for long-run models based on specific needs. Operational Conditions Operating Temperature: Functions effectively in a temperature range of 0 °C to 40 °C. Integrated Maintenance Bypass Breaker: Facilitates maintenance without interrupting power supply. Scalability: Can be expanded up to 40 kVA for growing power needs. Caster Wheels: Equipped for easy repositioning within facilities. Conclusion The Vertiv Liebert GXT MT LX (3 X 3) 10KVA UPS is engineered for high performance and reliability, making it an excellent choice for businesses that require uninterrupted power for their critical infrastructure. Its advanced features, compact design, and efficient operation ensure that essential systems remain operational during power outages. For further information, consult the official Vertiv website or authorized distributors.

Send Message
product image
ALL TYPES UPS & BATTERIES AMC

An Annual Maintenance Contract (AMC) for UPS systems typically includes routine maintenance, repair services, and emergency support to ensure optimal performance. It covers inspections, battery maintenance, and high-priority assistance during breakdowns, helping to extend the lifespan of your UPS and batteries. For more specific details, you can refer to the links provided in the search results. UPS AMC Services Overview: Purpose of AMC: The AMC is designed to provide comprehensive support for UPS systems, ensuring they operate efficiently and reliably. This includes regular maintenance, emergency repairs, and technical assistance. Key Components of AMC: Routine Maintenance: Regular inspections and servicing to prevent issues before they arise. Repair Services: Quick response to any failures or malfunctions, minimizing downtime. Emergency Support: 24/7 assistance to address urgent issues. Types of AMC Plans: Platinum Plan: Covers all spare parts during maintenance, excluding natural calamities. High-priority assistance during breakdowns. Regular preventive maintenance and detailed reports with recommendations. Gold Plan: Similar to the Platinum plan but does not include standby units. Focuses on critical equipment maintenance. Silver Plan: Basic support with engineers and technical assistance only. Maintenance Schedule: Monthly Checks: Visual inspections of batteries and connections. Measurement of ambient temperature and humidity. Cleaning of the UPS environment. Quarterly Checks: Voltage measurement of each battery cell. Conductance testing for battery health. Yearly Checks: Torque measurement of all connections. Testing of interconnecting cable resistance. Importance of Battery Maintenance: Regular maintenance is crucial as battery failures account for a significant percentage of UPS failures. Environmental conditions can greatly affect battery life, with temperature fluctuations leading to reduced performance. Contact Information: For inquiries or to set up an AMC, you can reach out via: Email: info@universalpower.co.in Phone: 8744823336

Send Message
product image
12V 150Ah

The Amaron Quanta 12V 150Ah battery is a sealed maintenance-free (SMF) VRLA (Valve Regulated Lead Acid) battery designed for various applications, including UPS systems and renewable energy storage. Here are the key details: Voltage: 12V Capacity: 150Ah Type: Sealed Maintenance-Free (SMF) VRLA Dimensions: Typically larger than smaller batteries, suitable for various applications (exact dimensions may vary by model) Weight: Heavier due to higher capacity (exact weight may vary) Warranty: Generally comes with a warranty period of around 24 months Applications: Ideal for UPS systems, inverters, solar energy storage, and other backup power solutions Features: Low self-discharge rate High cycle life Excellent performance in high-temperature conditions Vibration-resistant design Fully sealed to prevent leakage Customer Reviews: Average rating based on user feedback is positive, highlighting good value for money and satisfactory service. Contact Information: For inquiries, you can reach out via: Email:info@universalpower.co.in Call or WhatsApp: 8744823336 For more specific details, you may want to check the product listings on the respective websites or contact the suppliers directly.

Send Message
product image
12v 150ah batteries

The Amaron Quanta 12V 150Ah battery, also known as the 12AL150 model, is a sealed maintenance-free (SMF) battery designed for various applications. Here are the key details: Voltage: 12 Volts Capacity: 150 Ampere Hours (Ah) Battery Type: Absorbent Glass Mat (AGM) / Valve Regulated Lead Acid (VRLA) Dimensions: Length: 453 mm Width: 173 mm Height: 251 mm Weight: Approximately 45 kg (± 1 kg) Internal Resistance: 4.86 mΩ Warranty: 24 Months Discharge Characteristics: Capacity after 3 months of storage: 90% Capacity after 6 months of storage: 80% Design Features: Patented heavy-duty lead alloy Thick robust intercell connections Low impedance path for superior discharge performance Designed to perform in harsh tropical conditions Applications: Suitable for various applications including solar systems, UPS systems, and other backup power solutions. Manufacturer: Johnson Controls This battery is known for its reliability and long service life, making it a popular choice for both commercial and residential use.

Send Message

Still searching for