Bhiwadi
+918076792323

'9 cooling system'

Items tagged with '9 cooling system'

product image
HPL Lithium-Ion Battery Energy Storage System

The HPL Lithium-Ion Battery Energy Storage System is a type of energy storage technology that uses lithium-ion batteries to store and manage electrical energy. These systems are typically used to store excess energy generated from renewable sources like solar and wind or from the grid, and release it when needed to help stabilize energy supply and demand. Here’s a breakdown of the key components and features that are generally associated with Lithium-Ion Battery Energy Storage Systems (BESS), including those from HPL or similar manufacturers: Key Features: Lithium-Ion Technology: Lithium-ion batteries are favored for their high energy density, long cycle life, and efficient performance. They are commonly used in applications like electric vehicles, grid storage, and consumer electronics. Energy Storage: These systems store electrical energy in lithium-ion battery packs and release it during periods of high demand, or when renewable energy production is low (e.g., on cloudy days for solar energy systems). Efficiency: Lithium-ion batteries typically offer high efficiency in terms of energy conversion, with round-trip efficiencies often exceeding 90%. This means that most of the stored energy is usable when discharged. Modular Design: HPL and other manufacturers often design their battery systems with modularity in mind. This means that the system can be scaled to fit a variety of needs, from residential to commercial and industrial applications. Grid Integration: These energy storage systems are commonly integrated with the electrical grid. They can help balance grid frequency and voltage, provide backup power during outages, and support the integration of renewable energy sources by smoothing fluctuations in supply. Battery Management System (BMS): The BMS ensures the safety, performance, and longevity of the battery by monitoring the state of charge (SOC), temperature, and other critical parameters. It can also prevent overcharging, over-discharging, and overheating. Applications: Residential Use: Homeowners can use these systems to store solar energy for use during the night or power outages. Commercial & Industrial Use: Businesses can use these systems to reduce demand charges or to provide backup power. Grid-Scale: Large energy storage systems can be used to stabilize the grid and facilitate the integration of renewable energy at a larger scale. Advantages: Sustainability: By storing renewable energy, these systems contribute to reducing carbon footprints and dependence on fossil fuels. Flexibility: They can be used in a wide range of applications, including residential, commercial, and large-scale energy storage. Cost Savings: Especially in commercial applications, they can help reduce energy costs by managing peak demand and reducing reliance on expensive grid power during peak periods.

Send Message
product image
Emerson 3-Phase Ups In Manesar

Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues. Key Features of Emerson 3-Phase UPS: Power Capacity: 3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model. Suitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings. Technology: Double Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging. Efficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs. Battery Management: Integrated advanced battery management for monitoring health, charge, and backup times. High Availability: Designed to provide reliable power for mission-critical applications. Hot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply. Scalability: Many models allow for modular expansion, meaning you can add additional capacity as needed. Input/Output Voltage: Input Voltage: Common input voltages are 380V, 400V, and 415V (3-phase). Output Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards. Power Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency. Advanced Features: LCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring. Remote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics. Bypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime. Design and Durability: Compact Design: Many models are designed to be space-efficient without compromising on power or cooling needs. Rack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs. Thermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating. Applications: Data Centers: Ensures uptime for servers and networking equipment. Industrial Equipment: Protects critical machinery and automated systems from power failures. Telecommunications: Keeps communication systems running without interruption. Hospitals: Supports life-saving equipment and systems that require constant power. Commercial Buildings: Ensures backup power for office systems and equipment. Maintenance and Service: Smart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required. Serviceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition. Proactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations. Popular Models: Emerson (now part of Vertiv) offers various UPS models under different series, such as: Vertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications. Vertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability. Vertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications. Advantages of Emerson 3-Phase UPS: High Reliability: Ensures critical equipment remains powered during power failures or fluctuations. Advanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility. Energy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact. Scalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand. Conclusion: Emerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.

Send Message
product image
5 kW solar system installed at nooh school

Universal Power team has installed a 5 kW solar system at nooh school Key Details of the 5 kW Solar System Installation at Nooh School: Solar Power Generation: A 5 kW system typically generates around 20-25 kWh per day depending on sunlight hours and weather conditions. Annual Energy Production: The system could produce around 7, 300 to 9, 125 kWh annually, which can cover a significant portion of the school\'s energy needs. System Components: Solar Panels: Typically, 15-20 panels with a capacity of around 250W-330W each. Inverter: A 5 kW inverter is used to convert the DC power produced by the panels into AC power. Mounting Structure: The solar panels are mounted on the roof or ground, depending on the school\'s infrastructure. Grid Connection: The system is likely connected to the grid, allowing excess energy to be fed back into the grid via net metering, helping reduce electricity costs for the school. Benefits for Nooh School: Cost Savings: The school will benefit from reduced electricity bills by offsetting its grid power usage with solar energy. Sustainability: The system will contribute to a reduction in carbon emissions, helping the school be more environmentally responsible. Educational Opportunity: The solar installation can serve as a live example for students, providing them with a practical demonstration of renewable energy technology. Maintenance: The system requires minimal maintenance, with occasional cleaning of the panels to ensure optimal performance. Panel Lifespan: Solar panels generally last around 25-30 years, with a slight decline in efficiency over time. Inverter Lifespan: Inverters typically last around 10-15 years before needing replacement. Conclusion: The 5 kW solar system installed by Universal Power Team at Nooh School will provide long-term benefits, including reduced electricity costs, environmental sustainability, and educational opportunities for students to learn about solar energy. If more detailed information is needed, contacting Universal Power Team or the school would provide the specifics of the installation.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
Eaton 9395P UPS

The Eaton 9395P UPS is a high-performance uninterruptible power supply designed for critical applications. It features a three-phase online design with power ratings ranging from 250 to 1200 kVA, utilizing advanced technology for high efficiency and scalability. Key Specifications Power Ratings: 250-1200 kVA Input Voltage: Typically 480V, with options for 400V or 600V Efficiency: High double conversion efficiency with reduced energy losses Battery Types: Supports VRLA, AGM, and wet cell batteries Overload Capacity: 110% for 10 minutes, 125% for 2 minutes, 150% for 15 seconds Display: 7” or 10” touchscreen for monitoring and control Features Modular Design: Allows for easy scalability and maintenance. Advanced Monitoring: Provides real-time data and alerts for optimal performance. Compact Footprint: Designed to maximize power density in limited spaces. Applications Ideal for data centers, telecommunications, and industrial environments where reliable power is critical. For more detailed specifications, you can refer to the official Eaton documentation. ### Additional Features Energy Saver System (ESS): Achieves up to 99% efficiency, significantly reducing operational costs. Three-Level Converter Design: Reduces stress on components, extending their lifespan and reliability. Heat Reduction: Produces 33% less heat, leading to lower HVAC costs. Increased Power Density: Offers up to 20% more power in the same footprint compared to previous models. Redundancy: Modular design ensures inherent redundancy, preventing dropped loads. Battery Information Battery System: External battery systems are used, with options for lead-acid or lithium batteries. Batteries Included: Typically, batteries are not included and must be purchased separately. Lead Time Availability: Estimated lead time for delivery is 20+ weeks, depending on configuration and order specifics. Target Markets Enterprise Data Centers: Provides robust power protection for critical IT infrastructure. Colocation Facilities: Supports multiple clients with varying power needs. Server Farms and Telecommunications: Ensures uptime for essential services and applications. Healthcare and Financial Systems: Protects sensitive equipment and data from power interruptions. Conclusion The Eaton 9395P UPS is engineered for high efficiency and reliability, making it an excellent choice for organizations that require uninterrupted power supply. Its modular design, advanced features, and scalability cater to a wide range of applications, ensuring that critical systems remain operational during power disturbances. For further details, consult the official Eaton website or authorized distributors.

Send Message
product image
Vertiv 600 Kva Ups

The Vertiv 600 kVA UPS models, such as the Liebert APM and EXL S1, offer specifications like transformer-free designs, high efficiency (up to 99%), and modular configurations. They support various input voltages and provide robust power management features, ensuring reliable performance for critical applications. Vertiv 600 kVA UPS Models Liebert EXL S1 Capacity: 600 kVA Efficiency: Optimized for maximum efficiency and power density Voltage Support: Typically supports 380/400/415 V three-phase systems Features: Transformer-free design, advanced power management Liebert NX Capacity Range: 225-600 kVA Modes: High efficiency in both Eco-mode and double conversion mode Note: This model has been discontinued but was known for its reliability and performance in critical power applications Key Specifications Input Voltage: Supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Modular Configurations: Options available for scalability and redundancy Cooling Options: Designed to operate efficiently in various environmental conditions Applications Ideal for data centers, telecommunications, and other critical infrastructure requiring uninterrupted power supply. Suitable for environments where high efficiency and reliability are paramount.

Send Message
product image
12V 9Ah Battery

The Amaron Quanta 12V 9Ah battery is a sealed maintenance-free VRLA (Valve Regulated Lead Acid) battery designed for reliable performance in various applications. Key Specifications: Nominal Voltage: 12 Volts Rated Capacity: 9 Ampere Hours Dimensions: 151 mm x 65 mm x 101 mm Weight: Approximately 1.5 kg Warranty: 12 months Features: Corrosion-Resistant Alloy: Enhances cyclic life, especially in tropical environments. Low Self-Discharge Rate: Ensures longer shelf life and reliability. Maintenance-Free: No regular maintenance required, providing convenience. Applications: UPS Systems: Ideal for backup power in computers and electronic devices. Emergency Lighting: Suitable for use in emergency lighting systems. Industrial Equipment: Effective in various industrial applications requiring dependable power. This battery is known for its durability and efficiency, making it a preferred choice for users needing a reliable power source. The Amaron Quanta 12V 9Ah battery is a high-performance sealed maintenance-free VRLA (Valve Regulated Lead Acid) battery, ideal for various applications requiring dependable power. Key Specifications: Nominal Voltage: 12 Volts Rated Capacity: 9 Ampere Hours Dimensions: 151 mm x 65 mm x 101 mm Weight: Approximately 1.5 kg Warranty: 12 months offsite warranty Features: Reliable Functionality: Designed for consistent performance in critical applications. Fast Recharging: Capable of quick recharging to minimize downtime. Sealed Maintenance-Free: No need for regular maintenance, enhancing convenience. Heavy Duty Alloy Construction: Built to withstand deep discharge and overcharge conditions. Applications: UPS Systems: Ideal for providing backup power to computers and other electronic devices. Emergency Lighting: Suitable for use in emergency lighting systems. Industrial Equipment: Effective in various industrial applications where reliable power is crucial. Warranty Information: Warranty Type: 12 Months Offsite Warranty Service: Warranty service available at the nearest service center. This battery is widely recognized for its high quality and reliability, making it a popular choice among users needing dependable power solutions.

Send Message
product image
12V 9Ah

The Amaron Quanta 12V 9Ah battery is a sealed maintenance-free (SMF) VRLA (Valve Regulated Lead Acid) battery designed for various applications, including UPS systems. Here are the key details: Voltage: 12V Capacity: 9Ah Type: Sealed Maintenance-Free (SMF) VRLA Dimensions: Typically compact, suitable for small spaces (exact dimensions may vary by model) Weight: Lightweight for easy handling (exact weight may vary) Warranty: Generally comes with a warranty period of around 15 months Applications: Ideal for UPS systems, inverters, and other backup power solutions Features: Low self-discharge rate High cycle life Excellent performance in high-temperature conditions Vibration-resistant design Contact Information: For inquiries, you can reach out via: Email: info@universalpower.co.in Call or WhatsApp: 8744823336 UNIVERSAL POWER SYSTEM For more specific details, you may want to check the product listings on the respective websites or contact the suppliers directly.

Send Message
product image
20 KVA UPS

The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount). Here\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS: Key Features of the Vertiv Liebert GXT5-20KMVRT11UXLN: 1. Power Rating and Capacity: Power Rating: 20kVA / 20000VA Output Power: 16000W (16kW) at 208V (depending on load conditions) This provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure. 2. Voltage Configuration: Input Voltage: 208V (for 3-phase input) The GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements. 3. Topology: On-Line Double-Conversion: The GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection. This topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances. Zero transfer time from utility power to battery power ensures no downtime for connected equipment. 4. Waveform Type: Pure Sinewave Output: The UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference. 5. Battery Type and Runtime: Battery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems. External Battery Support: The Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications. Charging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity. 6. Runtime (Backup Time): The battery backup time will vary depending on the load. Here are some estimates: At 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes. At full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity. Extended runtime can be achieved with additional external battery cabinets. 7. Cooling: Fan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures. 8. Form Factor: Rackmount and Tower: The Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS. Rackmount form factor: 3U (for the rack version), designed for 19-inch rack installations. The rackmount option allows easy integration into standard server racks or data center environments. 9. Energy Efficiency and Certifications: Energy Star Certification: The Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation. It also has low total cost of ownership (TCO), thanks to its energy-efficient operation. High Efficiency Mode (Eco Mode): The UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit. 10. Interfaces and Monitoring: LCD Display: The UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status. Connectivity: USB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring. SNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network. Dry Contact Interface: Available for integration with building management or alert systems. 11. Advanced Features: Automatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity. Overload and Short-Circuit Protection: Protects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms. Smart Battery Management: The system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures. Audible Alarms: Provides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.

Send Message

Still searching for
9 cooling system?