product image
10KVA UPS

The Vertiv™ Liebert® GXE 6000-10000VA UPS is part of the Liebert GXE Series, which provides line-interactive power protection with advanced features, making it an ideal solution for small and medium-sized businesses, IT infrastructure, and critical equipment in need of reliable power backup. The Liebert GXE UPS offers features like Automatic Voltage Regulation (AVR), extended battery support, efficient performance, and compact design. Here are all the key details and specifications for the Vertiv™ Liebert® GXE 6000-10000VA UPS: Vertiv Liebert GXE 10000VA UPS (10kVA) Power Rating: 10kVA / 10000VA Output Power: 6000W to 8000W Input Voltage: 170V - 280V Output Voltage: 230V ± 10% Waveform: Simulated Sinewave (or Pure Sinewave for specific models) Battery Type: Sealed Lead-Acid (SLA) / VRLA Battery Capacity: Typically 12V, 18Ah or 24Ah (with external battery options) Charging Time: 4-6 hours for a full recharge Backup Time: 10-40 minutes depending on load and battery configuration Form Factor: Tower or Rackmount Interfaces: USB/Serial, SNMP (optional) Additional Features: AVR, Smart Battery Management, LCD Display, Overload Protection, Alarms, External Battery Support Key Features: Topology: Line-Interactive – This topology offers good protection and ensures that your equipment receives stable power during fluctuations, such as brownouts or overvoltages, without using battery power unnecessarily. Power Rating: 6kVA to 10kVA (6000VA to 10000VA) – Suitable for medium to large-sized IT infrastructure, servers, networking equipment, and other critical applications that need consistent and reliable power. Output Power: 6kVA (6000VA) models typically provide 3600W - 4800W of output power. 10kVA (10000VA) models provide 6000W - 8000W of output power, depending on the specific model and configuration. Input Voltage Range: 170V - 280V (wide input voltage range) – Provides protection from both high and low voltage fluctuations. Output Voltage: 230V ± 10% – Standard output voltage suitable for most business and IT applications. Waveform Type: Simulated Sinewave – In line-interactive mode, the output waveform is simulated sinewave. However, the UPS is designed to handle sensitive loads well. Automatic Voltage Regulation (AVR): The Liebert GXE UPS comes with AVR that corrects voltage fluctuations without switching to battery power, reducing battery wear and extending the overall life of the system. Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries – Commonly used for UPS systems due to their reliability and low maintenance. Battery Capacity: 12V batteries, with 18Ah, 24Ah, or higher capacity depending on the model and configuration. Extended Battery Support: The UPS can be connected to additional battery packs for longer backup runtimes if needed. Charging Time: Typically, the battery recharge time is around 4-6 hours for a full charge from a discharged state. Backup Time (Runtime): Backup time varies depending on load. For example: At 50% load, the runtime could range from 30 minutes to 1 hour. At full load, the backup time may range from 10-20 minutes, depending on the model and load. External Battery Packs can extend runtime significantly for longer power outages. Form Factor: Tower or Rackmount options are available, making the Liebert GXE adaptable for different environments, such as server rooms or small data centers. Rackmount models are designed for 19-inch racks and are ideal for installations in IT environments. Cooling: Fan-assisted cooling for efficient thermal management. Interfaces & Monitoring: USB/Serial Communication Ports for connection with monitoring and management software. SNMP Slot: Provides optional SNMP (Simple Network Management Protocol) support for remote monitoring and management. LCD Display: Many models include an LCD screen that shows real-time UPS status, load, battery condition, input/output voltage, and other important information. Smart Battery Management: Ensures that the batteries are efficiently charged and maintained, extending the life of the battery bank. Advanced battery diagnostics can help predict failures and improve overall UPS reliability. Overload Protection: Provides protection against equipment overload and ensures that the system shuts down or enters bypass mode in the event of a fault condition. Audible Alarms: Alarms provide real-time alerts for conditions like battery low, overload, fault conditions, and input/output abnormalities. Green Features: Energy-Efficient: Offers high energy efficiency to reduce operational costs. ECO Mode: In certain conditions, the system can operate in ECO mode to provide further energy savings, reducing electricity consumption.

Send Message
product image
ONLINE UPS REPAIRING SERVICE IN ANANDPUR BAWAL

Here\\'s a comprehensive guide to repairing Vertiv and Liebert online UPS systems: Preparation Before starting the repair process, ensure you have the necessary tools, documentation, and safety precautions in place. Familiarize yourself with the UPS system\\'s electrical and mechanical components. Tools and Equipment Multimeter Screwdrivers (flathead and Phillips) Torx driver (for some models) Wire strippers Pliers and wrenches Safety glasses and gloves Anti-static wrist strap or mat Safety Precautions Ensure the UPS system is turned off and unplugged from the power source. Verify the system is properly grounded. Wear protective gear, including safety glasses and gloves. Avoid touching electrical components or wires. Common Faults and Repairs Faulty Battery Symptoms: UPS not holding charge, frequent shutdowns, or battery failure. Repair: Replace the faulty battery with a new one of the same type and rating. Power Module Failure Symptoms: UPS not functioning, error messages, or overheating. Repair: Replace the faulty power module with a new one of the same type and rating. Control Board Failure Symptoms: UPS not functioning, error messages, or erratic behavior. Repair: Replace the faulty control board with a new one of the same type and rating. Fan Failure Symptoms: Overheating, noise, or reduced airflow. Repair: Replace the faulty fan with a new one of the same type and rating. Capacitor Failure Symptoms: UPS not functioning, error messages, or overheating. Repair: Replace the faulty capacitor with a new one of the same type and rating. Repair Procedures Disassembly Remove the UPS system\\'s outer casing and any internal components to access the faulty part. Document the wiring and connections before disconnecting them. Component Replacement Remove the faulty component and replace it with a new one of the same type and rating. Ensure proper connections and wiring. Reassembly Reassemble the UPS system in the reverse order of disassembly. Ensure all connections and wiring are secure. Testing and Verification Visual Inspection Verify all components are properly installed and connected. Check for any signs of physical damage or wear. Functional Testing Turn on the UPS system and verify it\\'s functioning correctly. Test the system under various load conditions. Performance Verification Verify the UPS system\\'s performance meets the manufacturer\\'s specifications. Check for any error messages or alarms. Documentation and Record-Keeping Repair Log Document the repair process, including the faulty component, replacement part, and any challenges encountered. Include before-and-after photos or videos. System Configuration Update the UPS system\\'s configuration and settings, if necessary. Verify the system is properly configured and functioning correctly. Additional Tips and Recommendations Manufacturer\\'s Documentation Consult the manufacturer\\'s documentation and repair guides for specific instructions and recommendations. Training and Certification Consider obtaining training and certification from the manufacturer or a reputable third-party organization. Preventive Maintenance Regularly perform preventive maintenance tasks to minimize the risk of future repairs. By following this guide, you\\'ll be able to repair your Vertiv or Liebert online UPS system efficiently and effectively. Remember to always follow safety precautions and manufacturer\\'s recommendations to ensure a successful repair.

Send Message

Still searching for
abnormal behavior?