Black Ups

Vertiv offers a range of black UPS systems, particularly the Liebert GXT5 series, which is known for its reliability and efficiency. Here are some key specifications and details: Vertiv Liebert GXT5 Series Power Ratings: Available in various capacities, including 1500VA, 3000VA, and higher configurations to meet diverse power needs. Design: Compact 2U rackmount or tower form factor. Black color finish for a sleek appearance. Input/Output Specifications: Input Voltage: 120V, with a range of 60-150V. Output Voltage: 120V, providing stable power to connected devices. Efficiency: Online double conversion technology ensures high efficiency and power quality. Energy Star certified models available for reduced energy consumption. Backup/Run Time: Backup time varies by load; for example, at half load, the 1500VA model provides approximately 13 minutes of backup time, while at full load, it offers around 5 minutes. Battery Type: Lead-acid batteries are standard, with options for lithium-ion in some models for extended life and reduced maintenance. Features: Advanced monitoring capabilities with LCD displays for real-time status updates. Hot-swappable batteries for easy maintenance without downtime. Multiple communication options, including USB, serial, and network management cards for remote monitoring. Applications Ideal for protecting critical IT equipment, including servers, networking devices, and telecommunications systems. Suitable for use in data centers, healthcare facilities, and other environments where power reliability is crucial. Conclusion The black Vertiv UPS systems, particularly the Liebert GXT5 series, provide robust power protection with a focus on efficiency, reliability, and advanced features, making them an excellent choice for various critical applications.

Send Message
product image
Vertiv Online Ups

Vertiv offers a range of online UPS (Uninterruptible Power Supply) systems designed to provide reliable power protection for critical applications, including data centers, telecommunications, and industrial environments. Here’s a detailed overview of Vertiv's online UPS solutions, including key features, specifications, benefits, and maintenance practices. Vertiv Online UPS Overview Purpose: Online UPS systems are designed to ensure continuous and clean power supply by converting incoming AC power to DC and then back to AC. This process provides maximum protection against power disturbances such as surges, sags, and outages. Key Features Continuous Power Supply: Provides uninterrupted power during outages, ensuring that sensitive equipment remains operational. Double-Conversion Technology: Converts incoming AC to DC and back to AC, delivering stable and high-quality power output. High Efficiency: Many models boast efficiencies of 95% or higher, particularly in eco-mode, reducing energy costs. Scalability: Options for parallel operation allow for easy scaling of capacity by adding additional units. Advanced Battery Management: Features for monitoring battery health, optimizing performance, and extending battery life, including temperature and state of charge monitoring. User-Friendly Interface: LCD or LED displays provide real-time data on power status, battery health, and load levels. Network Management Capabilities: Integration with remote monitoring systems through SNMP, allowing for proactive management and alerts. Vibration and Shock Resistance: Designed to withstand harsh operating conditions, making them suitable for industrial environments. Flexible Input/Output Options: Supports various voltages and phases, accommodating different application requirements. Specifications (Typical) Input Voltage: 380/400/415 V (three-phase), with some models supporting single-phase. Output Voltage: 380/400/415 V (three-phase). Output Frequency: 50/60 Hz (auto-sensing). Capacity Range: Varies widely, from small systems (1 kVA) to large systems (up to 500 kVA or more). Efficiency: Typically 95% to 98%, depending on model and operating conditions. Form Factor: Available in tower or rack-mounted configurations. Benefits Reliability: Provides a stable power supply, protecting sensitive equipment from power disturbances. Improved Power Quality: Filters out electrical noise and provides clean power, which is crucial for IT and telecommunications equipment. Cost Savings: High efficiency reduces operational costs, and predictive maintenance can prevent costly downtime. Robust Performance: Designed for heavy loads and capable of maintaining performance under varying conditions. Remote Monitoring: Enables proactive management and quick response to potential issues, enhancing system reliability. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Includes cleaning, tightening connections, and replacing worn-out components as necessary. Battery Management: Monitor battery health, conduct load tests, and replace batteries according to manufacturer guidelines. Documentation: Maintain records of inspections, tests, and repairs to track system performance over time. Professional Support: Engage professional services for emergency repairs, technical support, and routine maintenance. Conclusion Vertiv's online UPS systems provide critical power protection for a variety of applications. With their advanced features, high efficiency, and robust design, they are ideal for ensuring reliable power in environments where uptime is essential. Proper maintenance and proactive management are key to maximizing performance and longevity. If you need more specific information about particular models, configurations, or any other aspect, feel free to ask!

Send Message
product image
Online Ups Amc Repair & Services

As a leading provider of UPS services, we understand the criticality of uninterrupted power supply for your business. Our team of highly skilled technicians is dedicated to delivering efficient and reliable online UPS services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . With our expertise and experience, we offer comprehensive solutions for online UPS installation, maintenance, and repair. Whether you are looking for a new installation or need assistance with troubleshooting and repairs, we have got you covered. UPS Repair & Services In Manesar We specialize in UPS Repair & Services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . offering professional troubleshooting and repair. Our team is equipped to handle issues of any scale, ensuring your UPS systems are always in top working condition. Maintenance Contract After entering into AMC, the contract will do the 1st preventive maintenance to check UPS condition, Healthy and working UPS only will be considered under AMC and also Faulty will be repaired on chargeable basis before considering it under AMC. If the batteries are found faulty at the time of inspection it will have to be replaced before taking it under AMC. Any make, any capacity (expect Vertiv & Emerson) Unlimited Break Down calls (Except Wire wound components, batteries, transformers). Includes 100% labor and travel coverage 6 days/week, 8 hours/day. Performed by ACCESS factory trained Customer Engineers. Break down calls – UNLIMITED. Subject to all Terms & Conditions as noted in the ACCESS Maintenance Agreement. 8 Hours Turnaround Time. Preventive Service Preventive Measurement : 4 PM per year Cleaning up of Unit, Visual Inspection tocheck any deformation. Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current. Checking and Adjustment (If needed) of Control parameters on different PCBs. Tightness of all connections, if shut down possible. Functional Checking up of Rectifier section. Functional Checking up of Inverter section. Functional Checking up of Static Switch Section. With customer approval, perform operational tests of the system including unit transfer and battery discharge. Maintaining the posted checklist at the client place. Battery Health checks with Multi Meter. Battery AMC Introducing for the very first time in the Industry “Battery AMC”, wherein you get your additional 3rd year warranty only @15% of your previous pay for the batteries. Quanta Amaron Make of battery is only included in AMC. Battery should be within the warranty period. Currently AMC will be carried forward only for Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . Region. UPS Renting Cost Effective: Rental UPS is very cost effective, you can save on huge project costs. Power Stability: Provides stable power continuously and saves all your expensive equipment from Power Surges. No Minimum Requirements: Online UPS available from 1KVA to 600 KVA on rent for short & long term. No Maintenance Cost: UPS Rental helps you save on maintenance & Servicing cost. Customisable: Special customization facility available for your specific needs. No Power Cuts: Battery life is always ON, due to immediate replacement facility. Maintenance Contracts On line ups in each kVA rating and battery backup system are very sensitive issues and so it should be taken care utmost to enhance the life of UPS system and battery life for almost 99% up time during performance. Access Power Link is a leader in this market for 25 years having expertise and experience in the field to ensure hassle-free UPS AMC services on PAN INDIA level. UPS Servicing To Suit You Our response time is the time to get to site, not the time for a callback Travel and labour is included in all contract prices unless not required Our technical support is offered by actual UPS experts, not a call centre. Our inclusive parts contracts include ALL parts not just “consumables”. Our preventative maintenance includes multipoint checks not just visuals. We offer different plans to pass on savings during normal working hours.

Send Message
product image
Apc Ups Repairing And Maintenance In Aurangabad Sonipat

Repairing and testing an APC UPS (Uninterruptible Power Supply) involves several steps to diagnose issues and ensure the unit functions properly. Here’s a detailed guide on how to approach this: Common Issues with APC UPS Battery Failure: Most common issue; symptoms include frequent beeping and inability to hold a charge. Overload: The UPS may beep continuously if connected devices exceed its capacity. Faulty Output: No power output despite being plugged in. Firmware Issues: May require updates or resets. Tools Needed Multimeter Screwdriver set Replacement batteries (if needed) Laptop or PC for firmware updates Diagnostic software (if applicable) Testing Procedure Visual Inspection: Check for physical damage, burnt components, or loose connections. Inspect the battery for any signs of swelling or leakage. Battery Testing: Disconnect the UPS from the wall outlet. Use a multimeter to measure the battery voltage. Compare it to the rated voltage (e.g., 12V for most lead-acid batteries). If the voltage is significantly lower, consider replacing the battery. Load Testing: Connect a load tester to the UPS and apply a known load (within the UPS capacity). Monitor the output voltage and see if it remains stable under load. Output Testing: Plug the UPS into the wall and turn it on. Measure the output voltage with a multimeter to ensure it’s delivering the correct voltage (typically around 120V or 230V depending on your region). Check if the UPS switches to battery mode when you disconnect it from the wall. Overload Testing: Gradually increase the load on the UPS until it beeps or shuts down. Verify that it returns to normal operation once the overload is removed. Repair Procedures Battery Replacement: Follow the manufacturer’s guidelines for replacing batteries. Dispose of old batteries responsibly. Firmware Updates: Connect the UPS to a computer. Use APC’s software (like PowerChute) to check for and install firmware updates. Component Repair: If internal components (like capacitors or fans) are damaged, soldering skills may be required for repairs or replacements. Reassembly: Carefully reassemble the UPS, ensuring all screws are tightened and no wires are pinched. Final Testing After repairs, conduct a full load test to ensure the UPS operates correctly under stress. Monitor for any unusual noises or overheating during operation. Safety Precautions Always ensure the UPS is unplugged before performing internal inspections or repairs. Handle batteries with care, as they can be hazardous. Conclusion Regular testing and maintenance of your APC UPS can extend its lifespan and ensure reliable performance. If issues persist after self-repair attempts, consider consulting a professional technician or contacting APC support for assistance.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Luminous Ups

The Luminous LD30KH-PRO is a high-performance Inverter designed to provide reliable backup power for homes, offices, and small commercial setups. It is a part of Luminous' Pure Sine Wave Inverter series, offering high efficiency and stable power supply to sensitive equipment like computers, refrigerators, air conditioners, and other appliances. Here are the key features and specifications of the Luminous LD30KH-PRO: Key Features: Power Capacity: 30 kVA (Kilovolt-Ampere) – It is designed to support large power loads, making it suitable for medium to large residential, commercial, or industrial applications. Pure Sine Wave Output: Provides clean and stable output voltage, ensuring that sensitive equipment (like computers, air conditioners, and medical equipment) operates without issues, such as noise or voltage fluctuations. High Efficiency: The inverter operates with high efficiency, which reduces power loss and ensures that more of the battery's energy is used to power connected appliances. Advanced Microprocessor Technology: The inverter uses a microprocessor-based design to ensure high performance, protection, and reliability. It optimizes charging and discharging cycles, as well as load management. User-Friendly LCD Display: It comes with an intuitive LCD display that shows important information such as battery status, power usage, input and output voltage, and fault conditions. This helps users easily monitor and manage the system. Wide Input Voltage Range: The inverter operates with a wide input voltage range, which helps it perform well under varying input conditions. This feature helps protect connected equipment from power surges and fluctuations. Multiple Protection Mechanisms: Built-in protection features include overload protection, short-circuit protection, deep discharge protection, and battery reverse polarity protection, which ensures the safety of the connected equipment. Battery Compatibility: The Luminous LD30KH-PRO is compatible with both lead-acid and lithium-ion batteries, giving users flexibility depending on their preferences for battery technology. Smart Battery Management: The inverter comes with intelligent battery management to optimize battery performance, extending their lifespan and ensuring safe charging and discharging cycles. Compact and Reliable Design: Designed with a compact form factor and a durable build, the inverter is ideal for both indoor and outdoor installations and can be used for both backup power and off-grid applications. Applications: Residential Homes – For providing backup power for large appliances like air conditioners, refrigerators, lighting, and electronics. Small and Medium Businesses – For ensuring uninterrupted power supply to computers, servers, and other essential equipment. Commercial Use – Ideal for large offices, small industries, and workshops. Rural/Off-Grid Areas – Can be used in places with frequent power outages or no access to the grid, providing a reliable power solution. Specifications Summary: Rated Capacity: 30 kVA Output Type: Pure Sine Wave Input Voltage: 120V – 300V (depending on model) Charging Current: Adjustable (depends on load) Display: LCD with detailed status updates Battery Compatibility: Compatible with lead-acid and lithium-ion batteries

Send Message
product image
Vertiv 60 kVA UPS

The Vertiv 60 kVA Online UPS is an uninterruptible power supply (UPS) designed to provide reliable and continuous power to critical equipment in case of power interruptions. Here are some key details and features typically associated with this kind of UPS: Key Features: Online UPS Technology: The Vertiv 60 kVA UPS uses online double-conversion technology, meaning it provides constant, clean, and stable power to connected equipment by continuously converting incoming AC power to DC and then back to AC. High Capacity: With a capacity of 60 kVA (kilo volt-amperes), this UPS is ideal for medium to large-sized businesses or industrial applications that require a significant amount of power protection, such as data centers, manufacturing equipment, or IT infrastructure. Energy Efficiency: These systems are typically designed to offer high efficiency, reducing operational costs while maintaining reliable performance. Some models offer "eco-mode" functionality to optimize efficiency during non-critical times. Battery Management: Vertiv UPS units generally feature advanced battery management technology that ensures longer battery life, more efficient charging, and optimal performance. The batteries are usually hot-swappable, allowing for maintenance without shutting down the system. Compact Design: Despite its high capacity, the Vertiv 60 kVA Online UPS is designed to have a relatively compact form factor, making it easier to integrate into limited spaces in data centers or industrial settings. Communication and Monitoring: Many Vertiv UPS systems come equipped with intelligent monitoring systems that allow users to track performance, status, and any faults. This can often be done remotely through a web interface or software. Bypass Capability: Some models offer an internal bypass, which allows the load to continue operating even during maintenance or if the UPS needs to be shut down for any reason. Typical Applications: Data Centers: Ensuring that critical server equipment continues running during power interruptions. Industrial Automation: Protecting machinery and control systems from voltage sags or outages. Healthcare: Protecting medical equipment that is sensitive to power fluctuations. Telecommunications: Ensuring consistent power supply to communication infrastructure. Advantages: Continuous Power Protection: Ideal for environments where power outages can cause data loss, downtime, or even equipment damage. Scalability: Can be paired with additional units or battery banks for higher power requirements. Reliability: The Vertiv brand is well-regarded in the power protection industry for producing durable and dependable UPS systems.

Send Message
product image
Battery Replacement In Faridabad

Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each. Types of Batteries and Their Replacement Process 1. Lead-Acid Batteries Common Types: Flooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells. Sealed Lead-Acid (SLA): Maintenance-free and does not require water addition. Absorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats. Gel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications. Replacement Process: Turn off the system: Ensure the system is powered off, and disconnect it from the grid or load. Safety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases. Disconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal. Remove old batteries: Lift and remove the batteries carefully, especially if they're heavy. Clean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water. Install new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal. Check the system: Power on the system and check the voltage and charging status. Maintenance Tips: Regularly check the electrolyte levels in flooded batteries. Clean terminals and ensure the battery box or tray is secure. 2. Lithium-Ion Batteries Common Types: Lithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan. Lithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools. Lithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications. Lithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones. Replacement Process: Turn off the system: Disconnect the power source or system. Safety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage. Disconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal. Remove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries. Install the new battery: Place the new battery in the same orientation and secure it. Reconnect terminals: Attach the positive terminal first, followed by the negative terminal. Check the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly. Maintenance Tips: Lithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range. Battery Management System (BMS) should be monitored to ensure proper functioning and safety. Conclusion: Battery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation. Lead-acid batteries need regular maintenance, especially flooded types. Lithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance. Always follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.

Send Message
product image
Vertiv Liebert PS15 UPS

The Vertiv Liebert PS15 UPS is a model of Uninterruptible Power Supply (UPS) designed to provide reliable power protection for various types of critical equipment, such as servers, networking devices, and other essential electronics. Here's a general overview of its key features: Key Features: Power Capacity: The Liebert PS15 typically offers a 15kVA (kilovolt-ampere) power capacity, making it suitable for medium to large-sized IT and data center applications. Form Factor: It's available in both tower and rack-mounted configurations, providing flexibility in installation based on the user's space requirements. True Online Double-Conversion Technology: The UPS employs a double-conversion topology, which provides continuous, clean power to connected devices by isolating them from input power fluctuations, ensuring consistent voltage output. High Efficiency: The Liebert PS15 often features advanced efficiency modes to reduce energy consumption, particularly in non-critical load conditions. Scalability: Some models in this series can be expanded with external battery cabinets, providing longer backup runtimes when needed. Monitoring & Management: Equipped with advanced monitoring options, the UPS can be connected to networked management systems, offering remote monitoring, control, and alerting for efficient power management. Battery Technology: The unit uses valve-regulated lead-acid (VRLA) or lithium-ion batteries, depending on the configuration. VRLA batteries are the most common, though lithium-ion options may offer longer lifespan and better energy density. Input and Output Voltage: The UPS typically supports a wide input voltage range and provides stable 208V/400V output, depending on the model configuration. Safety Features: Includes built-in surge protection, overload protection, and short-circuit protection for both the unit and connected equipment. Applications: IT Infrastructure: Ideal for protecting servers, storage devices, and networking equipment in small and medium-sized data centers. Telecommunication: Provides power protection for critical telecommunications equipment. Healthcare: Ensures that sensitive medical equipment continues to operate without interruption. Manufacturing and Industrial: Often used in industries where downtime due to power failure is not an option. Maintenance and Support: Vertiv offers various support options for its UPS systems, including extended warranties, remote diagnostics, and on-site service.