Bhiwadi
+918076792323

'connections measurement'

Items tagged with 'connections measurement'

product image
ALL TYPES UPS & BATTERIES AMC

An Annual Maintenance Contract (AMC) for UPS systems typically includes routine maintenance, repair services, and emergency support to ensure optimal performance. It covers inspections, battery maintenance, and high-priority assistance during breakdowns, helping to extend the lifespan of your UPS and batteries. For more specific details, you can refer to the links provided in the search results. UPS AMC Services Overview: Purpose of AMC: The AMC is designed to provide comprehensive support for UPS systems, ensuring they operate efficiently and reliably. This includes regular maintenance, emergency repairs, and technical assistance. Key Components of AMC: Routine Maintenance: Regular inspections and servicing to prevent issues before they arise. Repair Services: Quick response to any failures or malfunctions, minimizing downtime. Emergency Support: 24/7 assistance to address urgent issues. Types of AMC Plans: Platinum Plan: Covers all spare parts during maintenance, excluding natural calamities. High-priority assistance during breakdowns. Regular preventive maintenance and detailed reports with recommendations. Gold Plan: Similar to the Platinum plan but does not include standby units. Focuses on critical equipment maintenance. Silver Plan: Basic support with engineers and technical assistance only. Maintenance Schedule: Monthly Checks: Visual inspections of batteries and connections. Measurement of ambient temperature and humidity. Cleaning of the UPS environment. Quarterly Checks: Voltage measurement of each battery cell. Conductance testing for battery health. Yearly Checks: Torque measurement of all connections. Testing of interconnecting cable resistance. Importance of Battery Maintenance: Regular maintenance is crucial as battery failures account for a significant percentage of UPS failures. Environmental conditions can greatly affect battery life, with temperature fluctuations leading to reduced performance. Contact Information: For inquiries or to set up an AMC, you can reach out via: Email: info@universalpower.co.in Phone: 8744823336

Send Message
product image
Online Ups Amc Repair & Services

As a leading provider of UPS services, we understand the criticality of uninterrupted power supply for your business. Our team of highly skilled technicians is dedicated to delivering efficient and reliable online UPS services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . With our expertise and experience, we offer comprehensive solutions for online UPS installation, maintenance, and repair. Whether you are looking for a new installation or need assistance with troubleshooting and repairs, we have got you covered. UPS Repair & Services In Manesar We specialize in UPS Repair & Services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . offering professional troubleshooting and repair. Our team is equipped to handle issues of any scale, ensuring your UPS systems are always in top working condition. Maintenance Contract After entering into AMC, the contract will do the 1st preventive maintenance to check UPS condition, Healthy and working UPS only will be considered under AMC and also Faulty will be repaired on chargeable basis before considering it under AMC. If the batteries are found faulty at the time of inspection it will have to be replaced before taking it under AMC. Any make, any capacity (expect Vertiv & Emerson) Unlimited Break Down calls (Except Wire wound components, batteries, transformers). Includes 100% labor and travel coverage 6 days/week, 8 hours/day. Performed by ACCESS factory trained Customer Engineers. Break down calls – UNLIMITED. Subject to all Terms & Conditions as noted in the ACCESS Maintenance Agreement. 8 Hours Turnaround Time. Preventive Service Preventive Measurement : 4 PM per year Cleaning up of Unit, Visual Inspection tocheck any deformation. Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current. Checking and Adjustment (If needed) of Control parameters on different PCBs. Tightness of all connections, if shut down possible. Functional Checking up of Rectifier section. Functional Checking up of Inverter section. Functional Checking up of Static Switch Section. With customer approval, perform operational tests of the system including unit transfer and battery discharge. Maintaining the posted checklist at the client place. Battery Health checks with Multi Meter. Battery AMC Introducing for the very first time in the Industry “Battery AMC”, wherein you get your additional 3rd year warranty only @15% of your previous pay for the batteries. Quanta Amaron Make of battery is only included in AMC. Battery should be within the warranty period. Currently AMC will be carried forward only for Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . Region. UPS Renting Cost Effective: Rental UPS is very cost effective, you can save on huge project costs. Power Stability: Provides stable power continuously and saves all your expensive equipment from Power Surges. No Minimum Requirements: Online UPS available from 1KVA to 600 KVA on rent for short & long term. No Maintenance Cost: UPS Rental helps you save on maintenance & Servicing cost. Customisable: Special customization facility available for your specific needs. No Power Cuts: Battery life is always ON, due to immediate replacement facility. Maintenance Contracts On line ups in each kVA rating and battery backup system are very sensitive issues and so it should be taken care utmost to enhance the life of UPS system and battery life for almost 99% up time during performance. Access Power Link is a leader in this market for 25 years having expertise and experience in the field to ensure hassle-free UPS AMC services on PAN INDIA level. UPS Servicing To Suit You Our response time is the time to get to site, not the time for a callback Travel and labour is included in all contract prices unless not required Our technical support is offered by actual UPS experts, not a call centre. Our inclusive parts contracts include ALL parts not just “consumables”. Our preventative maintenance includes multipoint checks not just visuals. We offer different plans to pass on savings during normal working hours.

Send Message
product image
Exide Battery

Exide Insta Brite is a range of automotive batteries known for providing reliable and high-performance power to vehicles. The Insta Brite series is specially designed to deliver superior cranking power, longer battery life, and low maintenance requirements, making it a popular choice for a wide range of vehicles. Below are the key features and details of Exide Insta Brite batteries: 1. Key Features: High Cranking Power: Provides excellent starting power for engines, even under extreme weather conditions (both hot and cold). Maintenance-Free: Exide Insta Brite batteries are designed to be virtually maintenance-free, reducing the need for constant checks and refills. Durability: Built with robust construction to handle tough environments, ensuring a longer lifespan and reliable performance. Enhanced Safety: These batteries come with advanced safety features, reducing the risk of leakage or damage. Shock and Vibration Resistance: Built to withstand shocks and vibrations that are common in automotive applications. 2. Technology: Lead-Acid Technology: Like most automotive batteries, Exide Insta Brite uses lead-acid technology, which ensures high performance, reliability, and cost-effectiveness. Calcium-Calcium Technology: Some variants of Exide Insta Brite incorporate calcium-calcium technology, which helps in reducing water loss and improving the overall battery performance. Advanced Grid Design: This design improves the efficiency and strength of the battery, enhancing its cranking power and overall battery life. 3. Types of Vehicles: Passenger Cars: Exide Insta Brite is commonly used in standard passenger vehicles like sedans, hatchbacks, and SUVs. Two-Wheelers: Some models are also suitable for motorcycles and scooters. Commercial Vehicles: Some higher-capacity variants are suitable for commercial vehicles, including trucks and buses. 4. Advantages: Longer Life: Designed to provide a longer service life, reducing the frequency of replacements. Excellent Starting Performance: Ensures smooth engine start-ups, especially in cold weather conditions. Cost-Effective: Provides great value by offering a balance of performance, durability, and cost. Environmentally Friendly: Being a lead-acid battery, it is recyclable, making it more eco-friendly than some other types of batteries. 5. Available Sizes/Models: Exide Insta Brite batteries come in different sizes and specifications based on the vehicle’s requirements. These sizes are designed to meet the specific needs of the vehicle, whether it is a compact car or a larger commercial vehicle. 6. Warranty: Exide Insta Brite batteries often come with a manufacturer warranty, typically ranging from 12 months to 36 months depending on the model. The warranty covers manufacturing defects and performance issues, offering peace of mind for the customer. 7. Maintenance: Low Maintenance: While it is a maintenance-free battery, users should still check the battery for any physical damage or signs of wear. Regular Inspections: It's recommended to periodically check the battery's charge level and connections for safety and optimal performance. 8. Application Areas: Automotive: Passenger cars, SUVs, and trucks. Commercial Vehicles: Larger vehicles such as buses and cargo trucks. Motorcycles & Two-Wheelers: Some models are designed for use in motorcycles and scooters. 9. Price Range: The price of Exide Insta Brite batteries typically ranges from INR 3,000 to INR 10,000 or more, depending on the specific model, size, and vehicle type. 10. Availability: Exide Insta Brite batteries are widely available through Exide dealers, automotive battery retailers, and online platforms in various regions. 11. Popular Models in the Insta Brite Series: Exide Insta Brite IB 100: Known for high starting power, suitable for a range of vehicles. Exide Insta Brite IB 120: Offers more power for larger vehicles. Exide Insta Brite IB 150: Ideal for commercial vehicles, providing reliable performance under heavy load conditions.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
12v 150ah batteries

The Amaron Quanta 12V 150Ah battery, also known as the 12AL150 model, is a sealed maintenance-free (SMF) battery designed for various applications. Here are the key details: Voltage: 12 Volts Capacity: 150 Ampere Hours (Ah) Battery Type: Absorbent Glass Mat (AGM) / Valve Regulated Lead Acid (VRLA) Dimensions: Length: 453 mm Width: 173 mm Height: 251 mm Weight: Approximately 45 kg (± 1 kg) Internal Resistance: 4.86 mΩ Warranty: 24 Months Discharge Characteristics: Capacity after 3 months of storage: 90% Capacity after 6 months of storage: 80% Design Features: Patented heavy-duty lead alloy Thick robust intercell connections Low impedance path for superior discharge performance Designed to perform in harsh tropical conditions Applications: Suitable for various applications including solar systems, UPS systems, and other backup power solutions. Manufacturer: Johnson Controls This battery is known for its reliability and long service life, making it a popular choice for both commercial and residential use.

Send Message
product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message
product image
car battery

The Amaron Pro 45Ah AAM-PR-0055B24LS is a car battery from the Amaron Pro series, designed for vehicles that require a high-performance, maintenance-free power source. Below are the key details about this battery: 1. Battery Type Type: Lead-acid, Maintenance-free Series: Amaron Pro Technology: AGM (Absorbent Glass Mat) or Conventional lead-acid depending on the specific model 2. Capacity and Specifications Ampere-Hours (Ah): 45Ah Cold Cranking Amps (CCA): Typically around 600 CCA (can vary depending on region or specific variant) Reserve Capacity (RC): ~85 minutes (again, this may vary slightly depending on regional specifications) Voltage: 12V Weight: Approx. 12-15 kg (depending on the construction, for a 45Ah battery) 3. Dimensions Length: 238 mm Width: 129 mm Height: 227 mm Terminal Configuration: B24LS (L indicates the positive terminal is on the left side when viewed from the front of the battery) 4. Application Designed for small to mid-sized vehicles, including sedans, hatchbacks, and compact SUVs. Suitable for standard gasoline-powered cars and may be used in diesel engines that require a 45Ah battery. It can also be used in some older vehicles or as a replacement for weaker or dead batteries. 5. Key Features Maintenance-Free: Sealed and spill-proof design with advanced lead-calcium technology. Long Life: Amaron Pro batteries are designed for long service life, offering higher durability and resistance to extreme weather conditions (high heat and cold). High Cranking Power: Provides excellent cold cranking amps (CCA), which ensures reliable starts in cold weather. Corrosion Resistance: Has improved resistance to corrosion, extending battery life and reducing the need for maintenance. Leak-Proof and Spill-Proof: The battery is fully sealed, which makes it maintenance-free and safer than traditional flooded batteries. 6. Warranty Amaron Pro batteries typically come with a 2-year free replacement warranty and an additional 18-month pro-rata warranty (varies by region). This warranty is subject to the terms and conditions of the manufacturer and distributor. 7. Advantages Strong Performance: High starting power, especially for vehicles with demanding electrical systems. Durability: Designed for hot climates and harsh conditions, suitable for both urban and rural driving conditions. Low Self-Discharge Rate: The battery retains charge for longer when the vehicle is not in use. 8. Pricing Prices can vary depending on location, but typically Amaron Pro batteries in the 45Ah range cost between ₹3, 500 - ₹5, 000 (Indian Rupees) or around $60-$100 in other markets. Always check with local dealers for specific pricing. 9. Compatibility This specific model (AAM-PR-0055B24LS) is typically designed to fit vehicles with a B24LS terminal configuration. It is important to verify that your vehicle is compatible with this size and terminal arrangement before purchasing. 10. Installation This battery comes pre-charged and does not require any initial maintenance before installation. However, it should be installed by a professional or an authorized dealer to avoid mishandling or improper connections. 11. Safety Considerations Proper Disposal: Batteries should be recycled responsibly once their life cycle ends, as they contain toxic chemicals like lead and sulfuric acid. Handling: Always wear gloves and safety goggles when handling batteries to avoid acid spills or contact with the terminals. Conclusion: The Amaron Pro 45Ah AAM-PR-0055B24LS is an excellent choice for those looking for a reliable, maintenance-free, and high-performing car battery. It is a popular option for vehicles that demand consistent starting power in varying conditions. As with all batteries, it is essential to ensure compatibility with your vehicle\'s specifications before purchasing.

Send Message
product image
battery

The Amaron Quanta 12V 9Ah battery is a type of lead-acid battery commonly used in various applications such as uninterruptible power supplies (UPS), electric vehicles, and other equipment requiring reliable power storage. Here are some key details about the Amaron Quanta 12V 9Ah battery: Specifications: Voltage: 12 volts Capacity: 9 ampere-hours (Ah) Type: Lead-acid battery (typically VRLA - Valve Regulated Lead Acid) Dimensions: Varies by manufacturer, but generally around 151mm x 65mm x 94mm (L x W x H) Weight: Approximately 3.5 to 4 kg, depending on the specific model and manufacturer. Terminal Type: Usually comes with F1 or F2 terminals. Operating Temperature Range: Typically between -15°C to +50°C. Cycle Life: Generally rated for about 300-500 cycles depending on depth of discharge and usage conditions. Features: Maintenance-Free: Designed to be maintenance-free, meaning no need for regular water topping. Leak-Proof Design: The VRLA design prevents leakage, making it safer for various applications. High Discharge Rate: Capable of delivering high currents for short periods, which is beneficial for applications requiring burst power. Deep Cycle Capability: Suitable for deep cycle applications, allowing for a deeper discharge without damaging the battery. Durability: Built to withstand harsh conditions and high temperatures, making it suitable for outdoor use. Applications: Uninterruptible Power Supplies (UPS): Provides backup power during outages. Electric Vehicles (EVs): Used in scooters, bikes, and other electric vehicles. Solar Energy Storage: Can be used in solar energy systems for storing power. Emergency Lighting: Powers emergency lighting systems. Telecommunications: Used in communication equipment for backup power. Maintenance Tips: Regular Inspection: Check for any signs of corrosion on terminals and ensure connections are tight. Proper Charging: Use a compatible charger and avoid overcharging to prolong battery life. Storage: Store in a cool, dry place and maintain a charge if not in use for extended periods. Safety Precautions: Avoid Short Circuits: Ensure terminals do not come into contact with conductive materials. Handle with Care: Batteries can be heavy; handle them carefully to avoid injury. Dispose Properly: Follow local regulations for battery disposal or recycling. For the most accurate and specific details, always refer to the manufacturer\'s datasheet or user manual, as specifications may vary slightly between different production batches or models.

Send Message

Still searching for
connections measurement?