product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Amaron Tubular Battery

Amaron is a well-known brand, and they manufacture various types of batteries, including tubular batteries. These batteries are primarily used for inverter applications (backup power for homes and businesses) and for solar energy systems. Key features of Amaron Tubular Batteries: Long Life: Tubular batteries are known for their long service life, and Amaron's version is no different. The tubular plates offer better performance and longer discharge cycles. Durability: Amaron batteries are designed to handle harsh conditions and provide consistent power over extended periods. Deep Discharge: Tubular batteries are ideal for deep discharge applications, which means they can be used for long durations without damaging the battery. Low Maintenance: Although they are flooded lead-acid batteries, Amaron batteries generally require less maintenance compared to traditional batteries. Fast Charging: They have the ability to charge faster compared to flat plate batteries, making them a good choice for areas with frequent power cuts. Amaron offers a variety of options in this category, depending on your energy needs and system configuration. The exact specifications (capacity, voltage, etc.) would depend on the model you are considering.

Send Message
product image
Vertiv 5kVA UPS

The Vertiv 5kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power for critical equipment, protecting them from power outages, surges, and other electrical disturbances. Vertiv is known for providing high-quality power management solutions, and a 5kVA UPS typically serves small to medium-sized applications such as: Server rooms Small data centers Telecommunication equipment Networking devices Medical equipment Key Features of a Vertiv 5kVA UPS: Power Capacity: 5kVA (Kilovolt-Ampere) translates to 5000 Volt-Amperes. This is roughly equivalent to 4000 watts, but the exact power capacity depends on the power factor (typically around 0.8 for UPS systems). Battery Backup: Ensures that connected equipment continues to run during power outages. The runtime depends on the load being connected and the battery capacity. Surge Protection: Provides protection against voltage spikes and surges, which can damage sensitive equipment. Voltage Regulation: The UPS can regulate incoming voltage to ensure connected devices receive consistent, safe power even if the input voltage fluctuates. Compact Design: These units are usually compact and designed to fit into standard server racks or other equipment areas. Advanced Features: Some Vertiv 5kVA models come with monitoring and management capabilities via network cards, allowing you to check the status, set alarms, or configure settings remotely. Scalability: Many Vertiv UPS systems are modular and can be expanded with additional battery packs or additional units if needed. Maintenance Bypass: Ensures continuous operation and simplifies service and maintenance tasks.

Send Message
product image
Amaron Quanta 12V 18Ah Battery

The Amaron Quanta 12V 18Ah is a type of sealed lead-acid (SLA) battery, commonly used for backup power applications, such as in UPS systems, inverters, and other critical power supply systems. Here's a detailed breakdown of its specifications and features: 1. General Overview Brand: Amaron Quanta Battery Type: Sealed Lead-Acid (SLA) Battery Voltage: 12 Volts (V) Capacity: 18 Ampere-Hours (Ah) 2. Key Features Longer Battery Life: Amaron Quanta batteries are designed for long-lasting performance and high reliability. They typically offer a good lifespan, especially in applications with a low depth of discharge (DOD). Maintenance-Free: The battery is sealed, so it doesn’t require regular maintenance (e.g., adding water). Vibration Resistance: These batteries are designed to withstand vibrations, making them ideal for use in environments like telecoms, solar power, and UPS systems. Wide Operating Temperature: They can operate in a wide range of temperatures, typically from 0°C to 40°C, making them versatile for use in different climates. 3. Technical Specifications Voltage: 12V (Nominal) Capacity: 18Ah (Ampere-Hours) Dimensions: Length: 181 mm Width: 77 mm Height: 167 mm Weight: Around 5.2 to 5.5 kg (varies slightly based on exact model) Charge Voltage: 14.4V to 15.0V (during charging) Discharge Voltage: Typically 10.5V to 11.0V for complete discharge Self-discharge: Less than 3% per month at 25°C 4. Applications UPS Systems: The 12V 18Ah battery is widely used in smaller uninterruptible power supplies (UPS) for providing backup power to sensitive electronics. Inverters: It can also be used in small-scale inverters to provide backup power to homes or offices. Telecommunications: In telecom applications, these batteries can be used for backup power to critical network equipment. Solar Energy Storage: Sometimes used in small-scale solar energy systems for storing energy for use during off-sunlight hours. 5. Battery Design Features Valve Regulated Lead-Acid (VRLA): The Amaron Quanta battery uses VRLA technology, which means the battery is sealed and uses a valve to release gas in case of overpressure. Deep Cycle: Designed for regular deep discharge cycles, making it suitable for power backup applications where batteries frequently discharge. Absorbent Glass Mat (AGM): Some models use AGM technology, where the electrolyte is absorbed in a fiberglass mat, allowing the battery to be spill-proof and leak-proof. 6. Charge/Discharge Characteristics Charging: Amaron Quanta batteries typically use a constant voltage charge, with a float charge voltage of around 13.5V to 13.8V. Discharge: The battery can typically discharge down to around 10.5V under load, but frequent deep discharges can reduce the battery's overall lifespan. 7. Advantages Longer Service Life: Typically offers a long life when maintained and used properly, making it a cost-effective option for long-term use. Reliable Performance: Known for reliability in maintaining charge over time, especially in demanding environments. Environmentally Friendly: Sealed and maintenance-free design minimizes risks associated with acid leakage and spills. 8. Maintenance Maintenance-Free Design: As mentioned, the battery is sealed, so it doesn't require regular maintenance like adding distilled water. However, regular inspection for corrosion on terminals and proper charge maintenance is recommended. Charging Recommendations: Always charge the battery in accordance with the manufacturer’s recommendations. Overcharging or undercharging can significantly reduce the battery’s lifespan. 9. Warranty Amaron Quanta batteries often come with a warranty that covers defects in material or workmanship, which typically lasts for 1 to 2 years depending on the seller and country-specific terms. 10. Compatibility Compatible Devices: The Amaron Quanta 12V 18Ah battery is commonly used in small UPS systems, solar power applications, and other critical systems where consistent backup power is required. Charging Systems: Can be used with most standard 12V chargers designed for SLA or AGM batteries. Conclusion The Amaron Quanta 12V 18Ah battery is an ideal solution for users looking for a reliable, low-maintenance, and efficient power backup option in smaller systems. It is widely used in UPS systems, inverters, and telecommunications applications where it can provide critical backup power when needed.

Send Message
product image
Vertiv 60 kVA to 200 kVA Ups

The Liebert SX series from Vertiv offers UPS systems ranging from 60 kVA to 200 kVA, utilizing full IGBT double conversion technology. This design enhances efficiency, reduces installation and operational costs, and provides reliable power backup solutions for critical applications. Key Features of Liebert SX 60kVA to 200kVA Modular Design: The Liebert SX series features a modular architecture that allows for easy scalability and maintenance. Front Access Design: This design minimizes repair time and optimizes installation and serviceability, making it user-friendly. Environmental Standards: The Liebert SX series is designed to meet high environmental standards, promoting energy efficiency and sustainability. ID Card for Each UPS: Each unit comes with an ID card that includes all working parameters, which helps in reducing downtime during maintenance. Applications Power Backup: Ideal for critical applications requiring uninterrupted power supply. Data Centers: Suitable for use in data centers where reliability and efficiency are paramount. Industrial Use: Can be utilized in various industrial settings to ensure consistent power availability. Contact Information for Further Inquiries Company: Universal Power System Location: Plot No.-70, Udyog Vihar-VI, Sector-37 Gurugram, Haryana, India -122001 Mobile - 8744823336 Email: info@universalpower.co.in

Send Message
product image
Vertiv Liebert PS15 UPS

The Vertiv Liebert PS15 UPS is a model of Uninterruptible Power Supply (UPS) designed to provide reliable power protection for various types of critical equipment, such as servers, networking devices, and other essential electronics. Here's a general overview of its key features: Key Features: Power Capacity: The Liebert PS15 typically offers a 15kVA (kilovolt-ampere) power capacity, making it suitable for medium to large-sized IT and data center applications. Form Factor: It's available in both tower and rack-mounted configurations, providing flexibility in installation based on the user's space requirements. True Online Double-Conversion Technology: The UPS employs a double-conversion topology, which provides continuous, clean power to connected devices by isolating them from input power fluctuations, ensuring consistent voltage output. High Efficiency: The Liebert PS15 often features advanced efficiency modes to reduce energy consumption, particularly in non-critical load conditions. Scalability: Some models in this series can be expanded with external battery cabinets, providing longer backup runtimes when needed. Monitoring & Management: Equipped with advanced monitoring options, the UPS can be connected to networked management systems, offering remote monitoring, control, and alerting for efficient power management. Battery Technology: The unit uses valve-regulated lead-acid (VRLA) or lithium-ion batteries, depending on the configuration. VRLA batteries are the most common, though lithium-ion options may offer longer lifespan and better energy density. Input and Output Voltage: The UPS typically supports a wide input voltage range and provides stable 208V/400V output, depending on the model configuration. Safety Features: Includes built-in surge protection, overload protection, and short-circuit protection for both the unit and connected equipment. Applications: IT Infrastructure: Ideal for protecting servers, storage devices, and networking equipment in small and medium-sized data centers. Telecommunication: Provides power protection for critical telecommunications equipment. Healthcare: Ensures that sensitive medical equipment continues to operate without interruption. Manufacturing and Industrial: Often used in industries where downtime due to power failure is not an option. Maintenance and Support: Vertiv offers various support options for its UPS systems, including extended warranties, remote diagnostics, and on-site service.

Send Message
product image
AMARON QUANTA VRLA SMF BATTERY

The Amaron Quanta VRLA SMF Battery 100 Ah is designed for various applications, particularly for use in uninterruptible power supply (UPS) systems and other backup power solutions. Here are the key specifications and features of this battery: Key Specifications Model: Amaron Quanta 100 Ah Type: VRLA (Valve Regulated Lead Acid) Sealed Maintenance Free (SMF) Voltage: 12 V Capacity: 100 Ah Weight: Approximately 30-35 kg (exact weight may vary) Dimensions: Typically around 407 x 173 x 220 mm (length x width x height) Operating Temperature: 0 – 40 °C Warranty: Usually 24 months (check specific terms) Key Features Maintenance-Free: The VRLA technology ensures that the battery does not require regular maintenance, such as topping up with water. High Performance: Designed for high discharge rates, making it suitable for applications that require reliable power. Durability: Built to withstand harsh conditions and has a long service life. Quick Recharge: Capable of accepting a fast charge, which is beneficial in environments with frequent power cuts. Safety Features: Equipped with safety valves to prevent overpressure and leakage. Applications UPS Systems: Ideal for providing backup power to critical systems during outages. Telecommunication Equipment: Used in telecom towers and data centers. Solar Power Systems: Can be used in solar energy storage applications. Industrial Applications: Suitable for various industrial equipment requiring reliable power. Conclusion The Amaron Quanta VRLA SMF Battery 100 Ah is a reliable choice for users looking for a robust and maintenance-free power solution. It is particularly well-suited for applications that demand consistent performance and durability. Always check with local suppliers for the most accurate pricing and availability.

Send Message
product image
12V 9Ah Battery

The Amaron Quanta 12V 9Ah battery is a sealed maintenance-free VRLA (Valve Regulated Lead Acid) battery designed for reliable performance in various applications. Key Specifications: Nominal Voltage: 12 Volts Rated Capacity: 9 Ampere Hours Dimensions: 151 mm x 65 mm x 101 mm Weight: Approximately 1.5 kg Warranty: 12 months Features: Corrosion-Resistant Alloy: Enhances cyclic life, especially in tropical environments. Low Self-Discharge Rate: Ensures longer shelf life and reliability. Maintenance-Free: No regular maintenance required, providing convenience. Applications: UPS Systems: Ideal for backup power in computers and electronic devices. Emergency Lighting: Suitable for use in emergency lighting systems. Industrial Equipment: Effective in various industrial applications requiring dependable power. This battery is known for its durability and efficiency, making it a preferred choice for users needing a reliable power source. The Amaron Quanta 12V 9Ah battery is a high-performance sealed maintenance-free VRLA (Valve Regulated Lead Acid) battery, ideal for various applications requiring dependable power. Key Specifications: Nominal Voltage: 12 Volts Rated Capacity: 9 Ampere Hours Dimensions: 151 mm x 65 mm x 101 mm Weight: Approximately 1.5 kg Warranty: 12 months offsite warranty Features: Reliable Functionality: Designed for consistent performance in critical applications. Fast Recharging: Capable of quick recharging to minimize downtime. Sealed Maintenance-Free: No need for regular maintenance, enhancing convenience. Heavy Duty Alloy Construction: Built to withstand deep discharge and overcharge conditions. Applications: UPS Systems: Ideal for providing backup power to computers and other electronic devices. Emergency Lighting: Suitable for use in emergency lighting systems. Industrial Equipment: Effective in various industrial applications where reliable power is crucial. Warranty Information: Warranty Type: 12 Months Offsite Warranty Service: Warranty service available at the nearest service center. This battery is widely recognized for its high quality and reliability, making it a popular choice among users needing dependable power solutions.