Bhiwadi
+918076792323

'controlled sockets'

Items tagged with 'controlled sockets'

product image
UPS

Vertiv Liebert PSA - 1000VA Mini Tower UPS PSA1000MT3-230U Specifications and Details The Vertiv Liebert PSA PSA1000MT3-230U is a line-interactive uninterruptible power supply (UPS) designed to provide reliable power protection for small office computers and electronic equipment. Below are the detailed specifications and features of this UPS model. Key Specifications Model: Vertiv Liebert PSA PSA1000MT3-230U Capacity: VA: 1000 VA Watts: 600 Watts Form Factor: Mini Tower Phase: Single Phase (1:1) Battery Type: Lead Acid Run Time: Typical: 5 minutes (varies with load) Warranty: 2 years Physical Dimensions Height: 234 mm Width: 147 mm Depth: 360 mm Weight: 9.5 kg Features User -Friendly LED Display: Provides easy operation and monitoring of UPS status. Socket Configuration: Multiple battery-backed and surge-protected sockets to accommodate different types of loads. Includes a mix of battery-backed and surge-only sockets. USB Communication: Comes with USB communications/shutdown software and cable for plug-and-play use. User -Replaceable Batteries: Designed for easy battery replacement to maximize the initial investment. Data Line Protection: Protects data lines to ensure the safety of connected devices. Environmental Compliance: Fully RoHS compliant, ensuring it meets environmental standards. Additional Information Input Voltage: Typically operates at 230 VAC. Output Waveform: Simulated sine wave. Runtime Performance: Provides 5 or more minutes of battery backup depending on the load level. Conclusion The Vertiv Liebert PSA PSA1000MT3-230U is an efficient and cost-effective solution for power protection in small office environments. Its combination of features, including user-friendly interfaces, multiple socket options, and easy maintenance, makes it a reliable choice for safeguarding electronic equipment against power interruptions.

Send Message
product image
Repairing And Maintaining UPS

Repairing And Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring the reliability and longevity of the power backup system. Here’s a detailed overview of UPS battery maintenance and repair practices. UPS Battery Types Lead-Acid Batteries: Valve-Regulated Lead Acid (VRLA): Maintenance-free and sealed, suitable for most UPS systems. Flooded Lead Acid: Requires periodic maintenance and water topping. Lithium-Ion Batteries: Increasingly used due to longer life and higher efficiency but may require specific handling protocols. Maintenance Practices Regular Inspections: Visual Check: Inspect batteries for physical damage, corrosion, or leaks. Look for swelling or bulging in case of lead-acid batteries. Connections: Ensure all terminals and connections are tight and free of corrosion. Cleaning: Clean battery terminals with a mixture of baking soda and water to remove corrosion. Rinse with clean water and dry thoroughly. Battery Testing: Voltage Checks: Regularly measure the voltage of each battery to identify weak cells. Load Testing: Perform load tests to ensure the battery can deliver the expected capacity under load conditions. Temperature Monitoring: Monitor battery temperature, especially in environments with high heat, as excessive temperatures can affect battery performance and lifespan. Electrolyte Level (for Flooded Batteries): Check and maintain the electrolyte levels in flooded lead-acid batteries. Top up with distilled water as necessary. Battery Health Monitoring: Use battery management systems (BMS) for advanced monitoring of battery health, state of charge, and state of health. Repair Practices Identifying Faults: Common issues include short-circuited cells, sulfation, and capacity loss. Use diagnostic tools to identify problems. Replacing Individual Batteries: If a battery within a pack fails, replace only the faulty battery if it’s compatible. However, it's often recommended to replace all batteries in a series to ensure uniform performance. Equalization Charging (for Flooded Batteries): Periodically perform equalization charging to balance the charge across all cells and prevent sulfation. Reconditioning: Some lead-acid batteries can be reconditioned through a process of controlled charging and discharging to restore capacity. This is not always successful and should be done by professionals. Battery Replacement: When batteries reach the end of their lifespan (typically 3-5 years for lead-acid), replace them with new ones. Ensure that replacements meet the manufacturer's specifications. Best Practices for Maintenance Documentation: Keep records of inspections, tests, and replacements to track battery performance over time. Environmental Conditions: Maintain an optimal environment for batteries—ideally, a cool, dry place free from excessive humidity and temperature fluctuations. Professional Servicing: Consider engaging professionals for complex repairs or maintenance tasks, especially for large or critical UPS systems. Training: Train personnel on proper handling, maintenance, and safety procedures related to UPS batteries. Conclusion Regular maintenance and timely repairs of UPS batteries are essential for ensuring the reliability of power backup systems. By implementing best practices, monitoring battery health, and addressing issues promptly, you can prolong the life of your UPS batteries and enhance overall system performance. If you have specific questions or need further details on any aspect, feel free to ask!

Send Message
product image
UPS Rental & UPS Repairing Service

Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems: Repair Process Initial Assessment Gather Information: Document symptoms such as alarms, performance issues, or failure to start. Visual Inspection: Look for signs of physical damage, burnt components, or loose connections. Diagnosis Self-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes. Multimeter Testing: Use a multimeter to check voltage levels, current, and resistance. Battery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity. Inspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault. Common Issues Battery Failure: The most common issue; batteries may need replacement due to age or improper charging. Capacitor Issues: Capacitors can degrade over time, leading to performance problems. Overheating: Caused by dust accumulation, blocked ventilation, or fan failure. Control Board Failures: Issues with the control board can affect functionality. Input/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues. Repair and Replacement Battery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity. Component Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics. Soldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board. Firmware Updates: If applicable, update the firmware for optimal performance. Testing After Repair Functional Testing: Run the UPS to ensure it operates correctly. Load Testing: Test under load conditions to verify performance and capacity. Battery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected. Final Inspection Safety Checks: Verify that all repairs meet safety standards. Documentation: Record all repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct periodic self-tests and inspections to identify potential issues early. Battery Maintenance: Keep battery terminals clean and ensure connections are tight. Cooling: Ensure proper ventilation around the UPS to prevent overheating. Environment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures. When to Seek Professional Help If issues are complex or beyond basic troubleshooting, consult a professional service. Use authorized Vertiv service centers for repairs to ensure quality and warranty compliance. Conclusion Repairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.

Send Message
product image
Vertiv 3 kVA UPS In Rohini Delhi

The Vertiv 3 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection and backup for critical equipment, making it ideal for IT environments, data centers, and small to medium enterprises. Here are the key details: Specifications: Power Rating: 3 kVA (approximately 2400 watts, depending on the power factor) Input Voltage: Generally operates within a range of 160-300 VAC. Output Voltage: Commonly 220/230/240 VAC. Output Waveform: Pure sine wave, ensuring compatibility with sensitive electronic devices. Battery Type: Typically uses sealed lead-acid or lithium-ion batteries (model-dependent). Features: Automatic Voltage Regulation (AVR): Stabilizes output voltage, protecting against surges and sags. LCD Display: Provides real-time monitoring of battery status, load levels, and input/output voltage. Multiple Outlets: Usually equipped with multiple output sockets for connecting various devices. Communication Ports: USB, RS-232, or network management ports for monitoring and management via software. Hot-Swappable Batteries: Allows for battery replacement without the need to power down the UPS. Applications: IT Equipment: Ideal for servers, switches, and networking equipment. Small to Medium Enterprises: Suitable for office equipment, point-of-sale systems, and workstations. Telecommunications: Used to provide backup power for telecom equipment. Advantages: Reliable Power Backup: Ensures continuous operation during power interruptions, minimizing data loss and downtime. Compact Design: Space-efficient design for easy installation in various environments. Energy Efficiency: Many models feature energy-saving modes and high efficiency. Considerations: Battery Runtime: Assess the expected runtime based on the total load connected; higher loads will decrease runtime. Maintenance: Regular maintenance and timely battery replacements are crucial for optimal performance. Always refer to the specific model’s user manual for detailed specifications, features, and installation instructions to ensure proper use and maintenance.

Send Message
product image
Vertiv 2 kVA UPS In Patel Nagar Gurgaon

The Vertiv 2 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power and protection for various electronic devices, making it suitable for both IT and industrial applications. Here are the key details: Specifications: Power Rating: 2 kVA (approximately 1600 watts, depending on the power factor) Input Voltage: Typically operates within a range of 160-300 VAC. Output Voltage: Commonly 220/230/240 VAC. Output Waveform: Pure sine wave for compatibility with sensitive equipment. Battery Type: Generally sealed lead-acid or lithium-ion (varies by model). Features: Automatic Voltage Regulation (AVR): Protects against voltage fluctuations by stabilizing the output. LCD Display: Provides real-time data on battery status, load level, and input/output voltage. Multiple Outlets: Usually includes several output sockets for connecting multiple devices. Communication Ports: USB, RS-232, or network management options for monitoring and management. Hot-Swappable Batteries: Enables battery replacement without shutting down the UPS. Applications: IT Infrastructure: Ideal for servers, networking equipment, and critical computing systems. Small to Medium Enterprises: Suitable for point-of-sale systems, office equipment, and telecommunications. Industrial Use: Can be used for powering essential equipment in various industrial settings. Advantages: Reliable Backup Power: Ensures continuity during power outages, preventing data loss and downtime. Compact and Efficient: Designed for easy installation and energy efficiency. Scalability: Can be used in conjunction with other UPS systems for larger setups. Considerations: Battery Runtime: Evaluate the expected runtime based on the connected load; larger loads will reduce runtime. Maintenance: Regular maintenance checks and timely battery replacements are essential for performance. Always consult the specific model’s user manual for detailed specifications, features, and installation instructions tailored to your needs.

Send Message
product image
Vertiv 1 kVA UPS In Saket Delhi

The Vertiv 1 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power and surge protection for various electronic devices and systems. Here are the key details: Specifications: Power Rating: 1 kVA (approximately 800 watts) Input Voltage: Typically 160-300 VAC (check specific models for exact range) Output Voltage: 220/230/240 VAC (configurable depending on the model) Output Waveform: Pure sine wave (for many models), ensuring compatibility with sensitive equipment. Battery Type: Usually sealed lead-acid or lithium-ion (depending on the model). Features: Automatic Voltage Regulation (AVR): Stabilizes output voltage and protects against power fluctuations. LCD Display: Provides real-time information on battery status, load level, and input/output voltage. Multiple Outlets: Typically features several output sockets for connecting devices. Communication Ports: USB and/or serial ports for monitoring and management through software. Hot-Swappable Batteries: Allows battery replacement without shutting down the UPS. Applications: IT Equipment: Ideal for servers, networking equipment, and workstations. Home Office: Suitable for personal computers, routers, and home office equipment. Small Business: Provides backup for point-of-sale systems and other essential devices. Advantages: Reliable Backup Power: Ensures continuous power during outages, preventing data loss and equipment damage. Compact Design: Space-saving design for easy installation in various environments. Energy Efficient: Many models feature energy-saving modes to reduce power consumption. Considerations: Battery Runtime: Check the battery runtime specifications based on the load connected. Maintenance: Regular checks and battery replacements may be necessary to ensure optimal performance. Always refer to the specific model\\'s manual for detailed specifications, features, and installation instructions.

Send Message
product image
Emerson 3kVA Online UPS

The Emerson 3kVA Online UPS is a reliable power backup solution designed for small to medium-sized applications. Here’s an overview of its key specifications and features: Specifications Capacity: 3 kVA (kilovolt-amps) Input Voltage: Generally supports a range from 160V to 300V AC. Output Voltage: Typically provides 230V AC (or 220V, depending on the region). Output Waveform: Pure sine wave output for compatibility with sensitive electronics. Input Frequency: Usually auto-sensing for 50/60 Hz. Features Online Double-Conversion Technology: Provides continuous power supply by converting AC to DC and then back to AC, isolating the load from power disturbances. LCD Display: Shows real-time information on battery status, load percentage, input/output voltage, and other operational metrics. Battery Type: Commonly uses sealed lead-acid or lithium-ion batteries, depending on the model. Charging Time: Full charging time can typically range from 4 to 8 hours. Runtime: Varies based on load; configurations can offer backup for several minutes to hours. Protection Features Overload Protection: Automatically shuts down to prevent damage if the load exceeds capacity. Short-Circuit Protection: Safeguards against potential damage from short circuits. Surge Protection: Protects connected devices from voltage spikes and transients. Thermal Management: Equipped with cooling mechanisms to prevent overheating. Connectivity Output Sockets: Multiple outlets for connecting various devices. Communication Ports: USB, RS232, or SNMP options for remote monitoring and management. Parallel Operation: Some models may support parallel operation for increased capacity and redundancy. Applications Ideal for: Small server rooms Networking equipment Medical devices Industrial applications Critical IT infrastructure Installation & Maintenance Installation: Often requires professional installation for optimal performance. Maintenance: Regular checks of battery health and system performance are recommended. Warranty Usually comes with a manufacturer’s warranty of 1 to 3 years, depending on the specific terms.

Send Message
product image
Emerson 40kVA Online UPS

The Emerson 40kVA Online UPS is a high-capacity uninterruptible power supply designed for critical applications where power reliability is essential. Here are the detailed specifications and features typically associated with this UPS model: Specifications Capacity: 40 kVA (kilovolt-amps) Input Voltage: Typically operates within a range of 380V to 480V AC. Output Voltage: Provides stable output, usually around 400V or 415V AC. Output Waveform: Pure sine wave output to ensure compatibility with sensitive electronic equipment. Input Frequency: Generally supports 50/60 Hz auto-sensing. Features Online Double-Conversion Technology: Ensures continuous power supply by converting incoming AC to DC and then back to AC, effectively isolating the load from power disturbances. LCD Display: Provides real-time information on operational status, including input/output voltage, battery status, and load percentage. Battery Type: Usually uses sealed lead-acid or lithium-ion batteries, depending on the specific model configuration. Charging Time: Full charge time can range from 4 to 8 hours, depending on battery type and condition. Runtime: Varies based on load; configurations can provide backup for several minutes to hours. Protection Features Overload Protection: Automatically shuts down the UPS to prevent damage if the load exceeds the rated capacity. Short-Circuit Protection: Protects against potential damage due to short circuits. Surge Protection: Guards connected equipment from voltage spikes and transients. Thermal Management: Equipped with fans and temperature sensors to prevent overheating. Connectivity Output Sockets: Multiple outlets for connecting various devices, often including hardwired connections. Communication Ports: USB, RS232, and SNMP options for remote monitoring and management. Parallel Operation: Supports multiple UPS units to work together for enhanced capacity and redundancy. Applications Suitable for: Data centers Telecommunications Industrial applications Medical equipment Critical IT infrastructure Installation & Maintenance Installation: Typically requires professional installation due to its size and complexity. Maintenance: Regular maintenance checks are essential for battery health and overall system performance. Warranty Often includes a manufacturer’s warranty, typically ranging from 1 to 3 years, depending on the model and specific terms.

Send Message
product image
Emeson 3kVA Online UPS

The Emeson 3kVA Online UPS is a robust uninterruptible power supply designed to provide reliable power protection for critical equipment. Here are the key details and features typically associated with such a UPS: Specifications Capacity: 3kVA (kilovolt-amps) Input Voltage: Usually supports a wide range, often around 170V to 300V AC. Output Voltage: Typically provides a stable 220V/230V AC output. Output Waveform: Pure sine wave, ensuring compatibility with sensitive electronics. Input Frequency: Commonly 50/60 Hz auto-sensing. Features Online Double-Conversion Technology: Converts incoming AC to DC and then back to AC, providing isolation from power anomalies. LCD Display: Provides real-time information on battery status, load, input/output voltage, and other parameters. Battery Type: Usually utilizes sealed lead-acid or lithium-ion batteries, depending on the model. Charging Time: Often takes around 4 to 8 hours for a full charge. Runtime: Varies based on load and battery configuration, typically offering several minutes to hours of backup. Protection Features Overload Protection: Automatically shuts down if the load exceeds the rated capacity. Short-Circuit Protection: Prevents damage in case of a short circuit. Surge Protection: Shields connected devices from voltage spikes. Temperature Control: Many models include thermal protection to prevent overheating. Connectivity Output Sockets: Multiple outlets for connecting various devices. Communication Ports: USB, RS232, or SNMP for monitoring and management. Battery Management System: Monitors battery health and optimizes charging cycles. Applications Ideal for: Computers and servers Networking equipment Medical devices Industrial applications Installation & Maintenance Installation: Typically requires a professional for optimal setup. Maintenance: Regular checks of battery health and connections recommended. Warranty Often comes with a manufacturer’s warranty, typically ranging from 1 to 3 years, depending on the terms.

Send Message