Bhiwadi
+918076792323

'cooling needs'

Items tagged with 'cooling needs'

product image
Emerson 3-Phase Ups In Manesar

Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues. Key Features of Emerson 3-Phase UPS: Power Capacity: 3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model. Suitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings. Technology: Double Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging. Efficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs. Battery Management: Integrated advanced battery management for monitoring health, charge, and backup times. High Availability: Designed to provide reliable power for mission-critical applications. Hot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply. Scalability: Many models allow for modular expansion, meaning you can add additional capacity as needed. Input/Output Voltage: Input Voltage: Common input voltages are 380V, 400V, and 415V (3-phase). Output Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards. Power Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency. Advanced Features: LCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring. Remote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics. Bypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime. Design and Durability: Compact Design: Many models are designed to be space-efficient without compromising on power or cooling needs. Rack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs. Thermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating. Applications: Data Centers: Ensures uptime for servers and networking equipment. Industrial Equipment: Protects critical machinery and automated systems from power failures. Telecommunications: Keeps communication systems running without interruption. Hospitals: Supports life-saving equipment and systems that require constant power. Commercial Buildings: Ensures backup power for office systems and equipment. Maintenance and Service: Smart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required. Serviceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition. Proactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations. Popular Models: Emerson (now part of Vertiv) offers various UPS models under different series, such as: Vertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications. Vertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability. Vertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications. Advantages of Emerson 3-Phase UPS: High Reliability: Ensures critical equipment remains powered during power failures or fluctuations. Advanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility. Energy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact. Scalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand. Conclusion: Emerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
UPS

The Vertiv 300kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection for critical applications. Here are the key details: Key Features Power Capacity: 300 kVA (kilovolt-amperes) capacity, suitable for large-scale operations. Topology: Typically utilizes a double-conversion online topology, ensuring continuous power supply and high efficiency. Input Voltage Range: Designed to handle a wide input voltage range, which helps in maintaining stability during voltage fluctuations. Output Voltage: Standard output voltage options, often configurable to meet specific requirements. Efficiency: High efficiency ratings, often exceeding 95% in online mode, which helps in reducing operational costs. Technical Specifications Dimensions: Compact design for easy installation in various environments. Weight: Hefty weight due to robust construction, ensuring durability. Cooling System: Advanced cooling mechanisms to maintain optimal operating temperatures. Battery Type: Typically uses VRLA (Valve Regulated Lead Acid) or Lithium-ion batteries, depending on the model. Runtime: Configurable runtime options based on battery capacity and load requirements. Monitoring and Management User Interface: LCD display for real-time monitoring of UPS status, battery health, and load levels. Remote Management: Capable of integration with network management systems for remote monitoring and control. Alarms and Notifications: Equipped with alarm systems to alert users of any issues or maintenance needs. Applications Data Centers: Ideal for protecting critical IT infrastructure. Telecommunications: Ensures continuous operation of communication systems. Industrial Applications: Supports manufacturing processes that require uninterrupted power. Maintenance and Support Service Options: Various service plans available, including preventive maintenance and emergency support. Warranty: Standard warranty options, with extended warranties available for additional peace of mind. Conclusion The Vertiv 300kVA UPS is a robust solution for organizations requiring reliable power protection. Its combination of high capacity, efficiency, and advanced monitoring features makes it suitable for a variety of critical applications. For more detailed specifications and options, you may refer to the official Vertiv website or product catalog.

Send Message
product image
Exide Batteries In Ajronda Faridabad

Exide batteries are known for their reliability and performance in various applications, including automotive, industrial, and renewable energy systems. Here\\'s an overview of Exide batteries, along with details about their racks and mounting options: Types of Exide Batteries Lead-Acid Batteries: Flooded Lead-Acid: Standard type, requires maintenance. Absorbent Glass Mat (AGM): Sealed, maintenance-free, and offers better vibration resistance. Gel Batteries: Sealed, good for deep-cycle applications. Lithium Batteries: Lightweight and longer lifespan compared to lead-acid. Suitable for advanced applications like electric vehicles and renewable energy systems. Features Durability: Designed to withstand harsh conditions. Deep-Cycle Capability: Ideal for applications requiring repeated discharge and recharge. Fast Charging: Some models support quick recharge times. Rack Systems Battery Racks: Typically made from steel or aluminum, designed to hold multiple batteries securely. Modular Designs: Allow for scalability based on the number of batteries needed. Ventilation: Many racks include features to promote airflow, which helps in cooling and battery performance. Installation and Maintenance Installation: Requires proper spacing and secure connections to ensure safety and performance. Maintenance: Regular checks on electrolyte levels (for flooded types) and connections are recommended for optimal performance. Applications Automotive: Starting, lighting, and ignition (SLI). Renewable Energy: Solar and wind energy storage systems. Industrial: Forklifts and other heavy equipment. Safety Considerations Ensure proper ventilation to prevent gas buildup. Follow manufacturer guidelines for installation and maintenance. Use appropriate personal protective equipment (PPE) during handling. Conclusion Exide batteries are versatile and widely used, supported by robust rack systems for various applications. Their features cater to both standard and specialized needs, ensuring reliability and performance. Always refer to specific product documentation for detailed specifications and installation instructions.

Send Message
product image
VERTIV 10 kVA UPS IN SONIPAT

The Vertiv 10 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection for critical applications. Here are some key details and features typically associated with this model: Key Features: Capacity: 10 kVA (kilovolt-amperes), suitable for medium-sized data centers and IT equipment. Topologies: Double-Conversion: Offers high-level protection against power disturbances. Line-Interactive: Provides good efficiency with moderate protection. Input/Output: Input Voltage: Typically accepts a wide range (e.g., 200-240V). Output Voltage: Usually provides a pure sine wave output at 230V. Battery: Type: Sealed lead-acid or lithium-ion options. Runtime: Varies based on load; can be extended with external battery packs. Efficiency: High efficiency ratings (up to 95% or more) in online mode to reduce energy costs. Cooling: Built-in cooling fans, sometimes with temperature monitoring. Communication: USB, SNMP, or RS-232 ports for remote monitoring and management. LCD display for status updates and alerts. Form Factor: Typically available in rack-mounted or tower configurations. Safety Certifications: Compliance with relevant safety and performance standards (e.g., CE, UL). Management Software: Often bundled with software for monitoring and managing the UPS and connected devices. Applications: Data centers Telecommunications Industrial equipment Medical facilities Maintenance: Regular battery checks and replacements. Firmware updates for management software. Considerations: Determine your total load to ensure the 10 kVA capacity is adequate. Assess the physical space for installation and cooling needs. Evaluate redundancy options if necessary for mission-critical applications.

Send Message
product image
Vertiv 40Kva Online Ups In udhyog vihar Gurgaon

The Vertiv 40 kVA UPS is designed to provide robust power protection and management for critical infrastructure in data centers, IT rooms, and industrial applications. It ensures that sensitive equipment remains operational during power disturbances. Key Specifications Power Rating: 40 kVA Input Voltage: Typically 380/400/415V (three-phase) Output Voltage: 380/400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion or line-interactive Efficiency: Up to 96% in eco mode Total Harmonic Distortion (THD): <5% at full load Battery and Runtime Battery Type: Typically uses VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Capacity: Varies based on configuration; options for extended runtime Charging Time: Usually 4-8 hours for a full charge (depending on battery type) Runtime: Configurable based on load; options for longer runtimes available Features Redundancy: N+1 configuration allows for increased reliability. Scalability: Can be expanded with additional units for greater capacity or redundancy. Smart Monitoring: Advanced LCD display for real-time monitoring of UPS status, input/output voltage, load percentage, battery status, and alarms. Communication Options: SNMP, USB, RS232, and optional network management cards for remote management. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Physical Characteristics Dimensions: Varies by model; generally within 60-80 cm in width and depth Weight: Approximately 200-400 kg (depends on battery configuration) Cooling: Typically air-cooled; ensure adequate airflow in the installation environment. Benefits Power Quality: Provides clean and stable power to connected equipment. High Availability: Ensures uptime for critical loads. Flexibility: Suitable for a wide range of applications including data centers, telecommunications, and industrial systems. User-Friendly: Intuitive interface and management software for easy operation and monitoring. Considerations Installation: Professional installation recommended to ensure optimal configuration. Maintenance: Regular inspections and battery replacements are crucial for reliability. Environment: Needs proper ventilation; avoid humid or extreme temperature environments. Cost: Initial investment can be significant; consider total cost of ownership including maintenance and energy savings. Applications Data Centers IT Infrastructure Telecommunications Industrial Equipment Medical Equipment Conclusion The Vertiv 40 kVA UPS is a versatile and powerful solution for ensuring continuous power availability and protecting critical infrastructure.

Send Message
product image
Microtek inverter In Bawal

Microtek inverters are popular for their reliability and efficiency in providing backup power solutions. Here are some key points: Types: Available in pure sine wave, square wave, and modified sine wave models to suit different needs. Applications: Used for home, office, and industrial backup power systems. Features: Energy-efficient, low maintenance, with features like digital display, smart charging, and battery management systems. Compatibility: Works well with various battery types, including lead-acid and lithium-ion. Durability: Built to withstand power fluctuations and extreme conditions. Microtek is known for its durable and cost-effective inverters, widely used across India and other regions.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Amaron Tubular Battery

Amaron is a well-known brand, and they manufacture various types of batteries, including tubular batteries. These batteries are primarily used for inverter applications (backup power for homes and businesses) and for solar energy systems. Key features of Amaron Tubular Batteries: Long Life: Tubular batteries are known for their long service life, and Amaron's version is no different. The tubular plates offer better performance and longer discharge cycles. Durability: Amaron batteries are designed to handle harsh conditions and provide consistent power over extended periods. Deep Discharge: Tubular batteries are ideal for deep discharge applications, which means they can be used for long durations without damaging the battery. Low Maintenance: Although they are flooded lead-acid batteries, Amaron batteries generally require less maintenance compared to traditional batteries. Fast Charging: They have the ability to charge faster compared to flat plate batteries, making them a good choice for areas with frequent power cuts. Amaron offers a variety of options in this category, depending on your energy needs and system configuration. The exact specifications (capacity, voltage, etc.) would depend on the model you are considering.