Bhiwadi
+918076792323

'dayal bagh colony faridabad'

Items tagged with 'dayal bagh colony faridabad'

product image
Battery

Amaron Short Tubular Batteries are a specific type of lead-acid battery designed primarily for use in inverter applications, particularly in regions with frequent power outages. These batteries are known for their durability, long life, and ability to handle deep discharge cycles. Below are the key details and specifications for Amaron Short Tubular Batteries: General Features: Design: Short tubular design allows for better space utilization and easier installation in various setups. Maintenance-Free: Many models are designed to be low-maintenance, requiring minimal attention during their lifespan. Deep Cycle Capability: Specifically engineered to handle deep discharges, making them ideal for inverter applications. Long Life: Known for their longevity, often lasting longer than conventional flat plate batteries. High Efficiency: Offers better charge acceptance and discharge performance, making them suitable for high-demand applications. Corrosion Resistance: Designed with materials that resist corrosion, enhancing the battery's lifespan. Specifications: While specific specifications can vary depending on the model, here are some common specifications for Amaron Short Tubular Batteries: Voltage: 12V Capacity: Typically ranges from 100 Ah to 220 Ah, depending on the model. Dimensions: Varies by model; common sizes include: 100 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) 150 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) 200 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) Weight: Generally ranges from 30 kg to 60 kg depending on capacity. Applications: Inverter Systems: Primarily used in home inverter systems for power backup. Solar Applications: Can also be used in solar power systems for energy storage. Commercial Use: Suitable for small businesses requiring reliable power backup solutions. Warranty: Amaron Short Tubular Batteries typically come with a warranty ranging from 24 to 36 months, depending on the specific model. Maintenance Tips: Water Level Check: If the battery is not maintenance-free, periodically check the electrolyte level and top up with distilled water if necessary. Terminal Cleaning: Regularly clean the battery terminals to prevent corrosion. Secure Installation: Ensure that the battery is securely mounted to prevent movement and damage. Environmental Considerations: Lead-acid batteries must be disposed of properly to prevent environmental harm. Many retailers offer recycling programs for old batteries. Conclusion: Amaron Short Tubular Batteries are a reliable choice for those needing a robust power backup solution, especially in areas with frequent power interruptions. For specific models and their detailed specifications, it is advisable to consult the manufacturer's catalog or speak with a retailer.

Send Message
product image
Batteries

Amaron Quanta batteries are a range of Sealed Maintenance Free (SMF) VRLA batteries designed for various applications, including UPS systems, renewable energy systems, and more. Here\\\'s an overview of the Amaron Quanta batteries and their specifications : Types of Amaron Quanta Batteries: Amaron Quanta 12V 7 Ah Battery: Capacity: 7 Ah Voltage: 12V Dimensions: 151 x 98 x 95 mm Material: PPCP Terminal Type: F2 Terminal Design Float Life: 10 Years Amaron Quanta 12V 12 Ah Battery: Capacity: 12 Ah Voltage: 12V Dimensions: 151 x 98 x 95 mm Material: PPCP Terminal Type: F2 Terminal Design Float Life: 10 Years Amaron Quanta 12V 18 Ah Battery: Capacity: 18 Ah Voltage: 12V Dimensions: 181 x 76 x 167 mm Material: PPCP Terminal Type: F2 Terminal Design Float Life: 10 Years Amaron Quanta 12V 26 Ah Battery: Capacity: 26 Ah Voltage: 12V Dimensions: 167 x 126 x 175 mm Material: PPCP Terminal Type: L Terminal (B5) Design Float Life: 10 Years Amaron Quanta 12V 42 Ah Battery: Capacity: 42 Ah Voltage: 12V Dimensions: 199 x 167 x 175 mm Material: PPCP Terminal Type: L Terminal (B6) Design Float Life: 10 Years Amaron Quanta 12V 65 Ah Battery: Capacity: 65 Ah Voltage: 12V Dimensions: 351 x 167 x 175 mm Material: PPCP Terminal Type: L Terminal (B6) Design Float Life: 10 Years Amaron Quanta 12V 84 Ah Battery: Capacity: 84 Ah Voltage: 12V Dimensions: 351 x 167 x 203 mm Material: PPCP Terminal Type: L Terminal (B6) Design Float Life: 10 Years Amaron Quanta 12V 100 Ah Battery: Capacity: 100 Ah Voltage: 12V Dimensions: 393 x 173 x 221 mm Material: PPCP Terminal Type: M8 x 25 mm Copper Design Float Life: 10 Years Amaron Quanta 12V 120 Ah Battery: Capacity: 120 Ah Voltage: 12V Dimensions: 393 x 173 x 240 mm Material: PPCP Terminal Type: M8 x 25 mm Copper Design Float Life: 10 Years Amaron Quanta 12V 130 Ah Battery: Capacity: 130 Ah Voltage: 12V Dimensions: 445 x 168 x 247 mm Material: PPCP Terminal Type: L Terminal (B6) Design Float Life: 10 Years Amaron Quanta 12V 150 Ah Battery: Capacity: 150 Ah Voltage: 12V Dimensions: 453 x 173 x 251 mm Material: PPCP Terminal Type: M8 x 25 mm Copper Design Float Life: 10 Years Amaron Quanta 12V 160 Ah Battery: Capacity: 160 Ah Voltage: 12V

Send Message
product image
Amaron Tubular Battery In Faridabad

Amaron tubular batteries are a type of rechargeable battery known for their durability and long service life, making them ideal for deep-cycle applications. Here are some key points: Design: They use tubular plates, which provide a longer lifespan compared to flat plates, especially in deep discharge conditions. Applications: Commonly used in inverters, solar power systems, and other backup power solutions. Durability: Known for high resistance to corrosion and low maintenance requirements. Performance: Excellent charge retention and high power output, even in harsh conditions. Maintenance: Requires periodic checking of water levels and occasional equalization charging. Amaron is a well-known brand in the Indian market, popular for its robust and reliable battery solutions.

Send Message
product image
Battery Replacement In Faridabad

Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each. Types of Batteries and Their Replacement Process 1. Lead-Acid Batteries Common Types: Flooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells. Sealed Lead-Acid (SLA): Maintenance-free and does not require water addition. Absorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats. Gel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications. Replacement Process: Turn off the system: Ensure the system is powered off, and disconnect it from the grid or load. Safety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases. Disconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal. Remove old batteries: Lift and remove the batteries carefully, especially if they're heavy. Clean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water. Install new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal. Check the system: Power on the system and check the voltage and charging status. Maintenance Tips: Regularly check the electrolyte levels in flooded batteries. Clean terminals and ensure the battery box or tray is secure. 2. Lithium-Ion Batteries Common Types: Lithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan. Lithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools. Lithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications. Lithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones. Replacement Process: Turn off the system: Disconnect the power source or system. Safety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage. Disconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal. Remove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries. Install the new battery: Place the new battery in the same orientation and secure it. Reconnect terminals: Attach the positive terminal first, followed by the negative terminal. Check the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly. Maintenance Tips: Lithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range. Battery Management System (BMS) should be monitored to ensure proper functioning and safety. Conclusion: Battery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation. Lead-acid batteries need regular maintenance, especially flooded types. Lithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance. Always follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.

Send Message
product image
20kva ups

The Vertiv ITA 20kVA UPS is a robust power protection solution designed for mission-critical applications. Here are the key details: Vertiv ITA 20kVA UPS Overview Type: True online, double conversion, three-phase UPS. **Power Rating - Capacity: 20 kVA / 20 kW. Input Voltage: Configurable for 380/400/415 VAC. Frequency: Operates at 50/60 Hz. Design Features Form Factor: Compact rack-tower design for installation flexibility. Dimensions: Designed to fit in standard server racks or as a standalone unit. Weight: Approximately 200 kg (varies by configuration). Performance Specifications Efficiency: High efficiency with a unity power factor, ensuring maximum power delivery. Output: Provides both three-phase and single-phase output options. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Battery and Backup Battery Type: Typically uses lead-acid batteries, with options for lithium-ion for longer life and reduced maintenance. Backup Time: Varies based on load; designed to provide extended backup for critical systems. Monitoring and Management Display: LCD screen for real-time monitoring of UPS status, battery health, and load levels. Communication: Equipped with SNMP/Web card for remote monitoring and management capabilities. Management Software: Compatible with Vertiv\'s monitoring solutions for enhanced management. Applications Ideal for small computer rooms, network equipment, and data centers requiring reliable power protection. Suitable for industries such as healthcare, finance, and telecommunications where uptime is critical. Conclusion The Vertiv ITA 20kVA UPS is a highly efficient and reliable power protection solution, designed to meet the demands of critical applications with its advanced features and robust performance.

Send Message
product image
Battery

The Amaron Quanta 12V 160Ah SMF VRLA Battery (12AL160) is a premium sealed maintenance-free lead-acid (SMF) battery that is primarily used in applications requiring reliable and long-lasting power backup. This battery is designed for both residential and industrial use, offering a robust power supply for inverters, UPS systems, and other equipment that require stable power during outages. Here’s a detailed breakdown of its features, specifications, and applications: Key Features: Battery Type: SMF (Sealed Maintenance-Free) VRLA (Valve-Regulated Lead Acid) battery. This type of battery does not require regular water refilling, making it low-maintenance. The VRLA technology helps regulate the gas pressure inside the battery, preventing acid leakage and reducing the need for manual maintenance. Capacity: 160 Ah (Ampere-Hours), suitable for medium to high power backup applications. Provides reliable power for inverter systems and UPS (Uninterruptible Power Supply) for homes, offices, and small to medium commercial setups. Voltage: 12V – Ideal for most inverter systems, particularly those used in residential and commercial settings. Design and Construction: Sealed Design: The SMF design makes the battery spill-proof, which ensures safety even in the event of accidents or mishandling. Robust construction: The high-quality components used in the battery provide resistance to high temperatures, deep discharges, and vibration. Maintenance-Free Operation: Maintenance-Free: No need for water topping, which saves time and effort in the long run. The battery is sealed, and the use of VRLA technology ensures no need for periodic maintenance, unlike traditional flooded lead-acid batteries. Deep-Cycle Capability: Deep Discharge Tolerance: This battery can discharge deeply without compromising its lifespan, making it a good choice for areas that face frequent power outages. It is designed for applications requiring frequent cycling (discharge/recharge) without damaging the internal plates. Durability: Long life: It offers a longer life span compared to regular flat-plate lead-acid batteries. The high-performance design ensures it can withstand extreme conditions like temperature fluctuations and high heat. Safety Features: Valve Regulated: The battery is equipped with a valve to control internal gas pressure, ensuring that no dangerous gas buildup occurs. Spill-Proof: Even in the event of damage, the battery will not leak electrolyte, making it safe to install in a variety of locations. Quick Charge & High Efficiency: The Amaron Quanta 12V 160Ah battery features quick charging capabilities, making it ideal for use in environments where fast recovery is important.

Send Message
product image
UPS

The Vertiv 3 kVA UPS options primarily include the Liebert GXT MT+ and Liebert GXT5 models, both designed for reliable power protection and conditioning. Liebert GXT MT+ (1/2/3 kVA): Topology: Online Double Conversion, ensuring a continuous and clean power supply. Efficiency: High efficiency ratings, typically around 94% in online mode. Input Voltage Range: Wide input voltage range to accommodate various power conditions. Battery Options: Configurable with internal and external battery options for extended runtime. Display: LCD display for real-time monitoring of UPS status and parameters. Liebert GXT5 (1-3 kVA): Topology: Also features Online Double Conversion for superior power quality. Efficiency: Offers up to 95% efficiency in online mode, contributing to lower operational costs. Form Factor: Compact design suitable for rack or tower configurations. Battery Management: Advanced battery management system for optimal battery performance and lifespan. Communication: Equipped with multiple communication options, including USB, RS232, and SNMP for remote monitoring. Key Features: Protection: Provides protection against power disturbances such as surges, spikes, and outages. Scalability: Can be integrated into larger systems for increased capacity and redundancy. Warranty: Typically comes with a standard warranty, often around 2 years, depending on the model and region. Support and Services: Technical Support: Vertiv offers technical support for installation, maintenance, and troubleshooting. Contact Information: Customers can reach out to Vertiv\'s support team for assistance or inquiries. This overview highlights the essential features and specifications of the Vertiv 3 kVA UPS models, suitable for various applications requiring reliable power protection.

Send Message
product image
12v200ah battery

The Amaron Quanta 12V 200Ah battery is a high-performance sealed maintenance-free (SMF) battery designed for various applications, particularly in UPS systems. Here are the key specifications and details: Specifications: Voltage: 12V Capacity: 200 Ah (Ampere-hours) Type: Sealed Maintenance-Free (SMF) Dimensions: Typically around 522mm x 240mm x 218mm (L x W x H) Weight: Approximately 60 kg Key Features: Spill-Proof Design: The battery is spill-proof, allowing for flexible installation in various positions. High Power Density: Optimizes space usage, making it suitable for installations with limited area. Quick Recharge Capability: Lower internal resistance enables faster recharge times. Long Life Cycle: Designed for extended service life, reducing the frequency of replacements. Applications: Uninterruptible Power Supply (UPS): Ideal for providing backup power to critical systems. Telecommunications: Supports communication systems that require reliable power. Renewable Energy Systems: Suitable for solar power storage and other renewable energy applications. Industrial Equipment: Ensures machinery and equipment remain operational during power outages. Advantages: Maintenance-Free Operation: No regular maintenance required, enhancing user convenience. Robust Construction: Built to withstand harsh conditions and provide consistent performance. Environmentally Friendly: Manufactured with eco-friendly materials and processes. The Amaron Quanta 12V 200Ah battery is an excellent choice for those seeking a reliable and efficient power source for various applications, particularly in environments where performance and dependability are crucial.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message

Still searching for
dayal bagh colony faridabad?