Bhiwadi
+918076792323

'heat generation'

Items tagged with 'heat generation'

product image
UPS

Vertiv Liebert EXS 80kVA UPS Specifications and Details The Vertiv Liebert EXS is a high-performance uninterruptible power supply (UPS) designed for critical applications requiring reliable power protection. Below are the detailed specifications and features of the Liebert EXS model, which covers the 30-80 kVA range. Key Specifications Model Range: Vertiv Liebert EXS (30-80 kVA) Capacity: Power Rating: Available in 30 kVA, 40 kVA, 60 kVA, and 80 kVA configurations. Input Voltage: Typically operates at 208/220/230/240 VAC. Output Voltage: Configurable to match the input voltage. Phase: Three-phase input and output. Battery Type: Sealed lead-acid or lithium-ion options available. Physical Dimensions Height: Varies by model; typically around 1, 800 mm. Width: Varies by model; typically around 600 mm. Depth: Varies by model; typically around 800 mm. Weight: Varies by model; typically between 500 kg to 800 kg. Features High Efficiency: Offers up to 96% efficiency in double conversion mode, reducing energy costs and heat generation. Scalability: Modular design allows for easy scalability to meet growing power needs. Advanced Monitoring: Equipped with a user-friendly LCD display for real-time monitoring of UPS status and performance metrics. Flexible Configuration: Supports various configurations including parallel operation for redundancy and increased capacity. Smart Battery Management: Extends battery life through intelligent charging and discharging cycles. Environmental Compliance: Designed to meet global environmental standards, including RoHS compliance. Additional Information Output Waveform: Pure sine wave output for compatibility with sensitive electronic equipment. Communication Options: Multiple communication interfaces including SNMP, Modbus, and USB for integration with building management systems. Runtime Performance: Configurable runtime based on battery capacity and load requirements. Conclusion The Vertiv Liebert EXS 30-80kVA UPS is an ideal solution for data centers, industrial applications, and critical infrastructure requiring robust power protection. Its high efficiency, scalability, and advanced monitoring capabilities make it a reliable choice for ensuring continuous power supply and protecting sensitive equipment from power disturbances.

Send Message
product image
UPS

Emerson offers a range of three-phase industrial UPS systems designed to provide reliable power protection for critical applications. Here are some key details typically associated with Emerson's three-phase UPS solutions: Key Features Power Capacity: Models often range from 10 kVA to several hundred kVA, catering to different industrial requirements. Topology: Many models utilize an online double-conversion topology, which ensures continuous power supply and zero transfer time during outages. Efficiency: High-efficiency ratings (up to 96% or more) help reduce energy costs and heat generation. Modular Design: Many systems allow for modular configurations, enabling easy scalability and redundancy. Smart Battery Management: Advanced battery management systems extend battery life and enhance performance. User Interface: LCD screens or touchscreen interfaces for real-time monitoring, diagnostics, and control. Communication Protocols: Various options for remote monitoring and integration, including SNMP, Modbus, and other industry-standard protocols. Input/Output Configuration: Flexible I/O options for different electrical environments, often with customizable settings. Applications Data centers Industrial automation systems Telecommunications Manufacturing facilities Critical power applications in healthcare Considerations Installation: Requires professional installation to ensure compliance with local electrical codes and optimal performance. Maintenance: Regular maintenance checks are necessary for reliability; consider a service contract for ongoing support. Load Assessment: Properly assess total load requirements to select the appropriate UPS capacity. Environmental Conditions: Ensure the UPS is suitable for the operating environment (temperature, humidity, etc.). Popular Models Emerson has various models within its UPS lineup, including: Liebert APM: Modular UPS systems known for scalability and high efficiency. Liebert EXL S1: High-density UPS for critical loads, offering excellent performance and efficiency. Conclusion When considering an Emerson three-phase industrial UPS, it's essential to evaluate specific needs, including power requirements, space constraints, and operational conditions. For the most accurate and detailed information, including specifications and installation requirements, consult Emerson's official documentation or contact a local representative. If you have specific models or features in mind, let me know!

Send Message
product image
UPS

The Vertiv Liebert EXM is a modular uninterruptible power supply (UPS) designed for critical applications requiring high availability and reliability. It is particularly suitable for data centers, telecommunications, and other environments where power continuity is essential. Below are the key details and specifications of the Vertiv Liebert EXM UPS: General Features: Modular Design: The Liebert EXM features a modular architecture, allowing for easy scalability. Users can add or remove power modules as needed to meet changing power requirements. High Efficiency: The UPS is designed for high efficiency, often exceeding 95% in double conversion mode, which helps reduce energy costs and heat generation. Flexible Configuration: Available in various configurations, including single-phase and three-phase outputs, to accommodate different applications and environments. Advanced Monitoring: Equipped with advanced monitoring and management features, including a user-friendly LCD display and network management capabilities, allowing for remote monitoring and control. Redundancy: Supports N+1 redundancy, ensuring that if one module fails, the remaining modules can continue to provide power without interruption. Hot-Swap Capability: Modules can be replaced or serviced without shutting down the UPS, ensuring continuous operation. Smart Battery Management: Features intelligent battery management systems that optimize battery performance and lifespan. Specifications: While specific specifications can vary based on the model and configuration, here are common specifications for the Liebert EXM UPS: Power Ratings: Typically available in configurations ranging from 10 kVA to 40 kVA per module, with the ability to scale up to higher capacities by adding modules. Input Voltage: 380/400/415V three-phase (configurable). Output Voltage: 380/400/415V three-phase (configurable). Frequency: 50/60 Hz (auto-sensing). Efficiency: Up to 95% in double conversion mode and even higher in eco-mode operation. Battery Type: Typically uses valve-regulated lead-acid (VRLA) batteries, with options for lithium-ion batteries in some configurations. Operating Temperature: Generally operates in the range of 0°C to 40°C (32°F to 104°F). Dimensions: Varies based on the configuration and number of modules; typically, a standard 10 kVA module might have dimensions around 600 mm (W) x 800 mm (D) x 2000 mm (H). Weight: Weight varies by configuration but can range from 50 kg to over 200 kg for larger systems. Applications: Data Centers: Ideal for protecting critical IT infrastructure from power disruptions. Telecommunications: Ensures reliable power for telecom equipment and networks. Industrial Applications: Suitable for manufacturing and process control systems requiring uninterrupted power. Healthcare: Provides backup power for critical medical equipment and systems. Warranty and Support: Vertiv typically offers a standard warranty period for its UPS systems, which may vary by region and model. Extended warranty and service plans are often available. Maintenance Tips: Regular Testing: Conduct regular testing of the UPS and batteries to ensure proper operation. Firmware Updates: Keep the UPS firmware updated to benefit from the latest features and improvements. Environmental Monitoring: Ensure the UPS is installed in a suitable environment, with adequate cooling and ventilation. Conclusion: The Vertiv Liebert EXM UPS is a robust and flexible solution for critical power applications, offering high efficiency, modularity, and advanced monitoring capabilities. For specific models, configurations, and detailed specifications, it is advisable to consult the manufacturer\'s documentation or contact a Vertiv representative.

Send Message
product image
UPS

The Vertiv 500 kVA UPS is a high-capacity uninterruptible power supply designed for large data centers, critical infrastructure, and industrial applications. Here are the key details: Specifications Power Rating: 500 kVA Input Voltage: Typically supports 380/400/415V three-phase configurations. Output Voltage: 380/400/415V three-phase. Frequency: 50/60 Hz, auto-sensing. Key Features Double Conversion Technology: Provides clean and stable power by converting AC to DC and then back to AC, ensuring zero transfer time during outages. High Efficiency: Designed for high efficiency, often exceeding 95% in online mode, minimizing energy costs and reducing heat generation. Modular Design: Can be configured in a parallel setup with multiple units for redundancy and increased capacity. Smart Battery Management: Enhances battery performance and lifespan through advanced charging techniques. User-Friendly Interface: Equipped with an LCD touchscreen display for real-time monitoring and easy access to operational data. Physical Characteristics Dimensions: Varies based on the specific model; typically around 1200 mm x 800 mm x 2400 mm (length x width x height). Weight: Approximately 800-1000 kg (exact weight may vary based on configuration). Cooling: Air-cooled; requires adequate space for ventilation. Safety Features Overload Protection: Prevents damage during overload conditions. Short Circuit Protection: Automatically disconnects the unit in case of short circuits. Thermal Protection: Equipped with temperature sensors to prevent overheating. Applications Data Centers: Provides reliable power for IT equipment and servers. Telecommunications: Ensures consistent power for telecom infrastructure. Industrial: Supports critical processes in manufacturing and production environments. Maintenance and Support Service Agreements: Vertiv offers various service plans to ensure reliability and uptime. Remote Monitoring: Many models come with options for remote access and monitoring capabilities. Conclusion The Vertiv 500 kVA UPS is engineered for high performance and reliability, making it suitable for critical applications across various sectors. For specific model details, configurations, pricing, and installation, it is recommended to consult with Vertiv or an authorized distributor.

Send Message
product image
Vertiv 10kVA Ups In Omaxe City Sonipat

The Vertiv 10kVA UPS is a true online double-conversion UPS designed to provide high-quality power protection for critical applications. Here are its key specifications and features: Specifications: Power Rating: 10kVA / 8kW Input Voltage: 230V AC Output Voltage: 230V AC Input Frequency: 50/60 Hz Output Frequency: 50/60 Hz Efficiency: Up to 94% (depending on load) Battery Type: Valve-Regulated Lead-Acid (VRLA) Battery Capacity: Typically provides backup for 10-15 minutes at full load (depending on battery configuration) Dimensions: Varies by model, typically around 700 x 500 x 1000 mm Weight: Approximately 80-100 kg (depending on configuration) Features: True Online Operation: Provides continuous power supply without any transfer time, ensuring zero downtime. Double-Conversion Technology: Ensures high-quality power output, independent of input voltage and frequency. High Efficiency: Reduces energy costs and heat generation, contributing to a more sustainable operation. Advanced Battery Management: Prolongs battery life and ensures optimal performance through intelligent charging and discharging. LCD Display: Provides real-time monitoring of UPS status, including input/output voltage, load percentage, and battery status. Modular Design: Allows for easy maintenance and upgrades. Multiple Communication Ports: Includes RS-232, USB, and optional SNMP for remote monitoring and management. Hot-Swappable Batteries: Enables battery replacement without interrupting power to the load. Parallel Capability: Allows for scalability and redundancy in high-availability applications. Applications: Data Centers: Ensures reliable power for critical IT infrastructure. Telecommunications: Protects sensitive telecom equipment from power disturbances. Medical Facilities: Supports essential medical equipment requiring uninterrupted power. Industrial Applications: Suitable for manufacturing and process control systems. Financial Institutions: Provides reliable power for critical financial systems. Services: Engineering: Customized solutions for specific power requirements. Installation: Professional installation services to ensure proper setup. Preventive Maintenance: Regular maintenance to ensure optimal performance and reliability. Monitoring: Remote monitoring services to track UPS performance and health. Recycling: Environmentally responsible disposal of old batteries and equipment. Certifications: ISO 9001: Quality management system certification. ISO 14001: Environmental management system certification. ISO 45001: Occupational health and safety management system certification. CE: Conforms to European Union safety and environmental standards. UL: Conforms to Underwriters Laboratories safety standards. Warranty: Standard Warranty: Typically offers a 2-year warranty on the UPS system and batteries. Extended Warranty: Options for additional warranty coverage may be available. Additional Information: The Vertiv 10kVA UPS is designed to provide high-quality power protection for critical applications, ensuring maximum uptime and reliability. Its true online double-conversion technology and advanced battery management features make it an ideal choice for data centers, telecommunications, medical facilities, and other industries requiring high-availability power systems. If you need more specific details or have further questions, feel free to ask!

Send Message
product image
Emerson Vertiv 6KVA Ups In Mehrauli Gurugram

The Emerson Vertiv 6KVA 1:1 Phase Online UPS with an inbuilt isolation transformer is designed to provide reliable power protection for critical applications, particularly in environments requiring high levels of power quality and isolation. Here are the key specifications and features: Specifications: Power Rating: 6kVA / 4.8kW Input Voltage: 230V AC Output Voltage: 230V AC Input Frequency: 50/60 Hz Output Frequency: 50/60 Hz Efficiency: Up to 92% (depending on load) Battery Type: Valve-Regulated Lead-Acid (VRLA) Battery Capacity: Typically provides backup for 10-15 minutes at full load (depending on battery configuration) Dimensions: Varies by model, typically around 600 x 400 x 800 mm Weight: Approximately 50-70 kg (depending on configuration) Features: True Online Operation: Provides continuous power supply without any transfer time, ensuring zero downtime. Inbuilt Isolation Transformer: Enhances power quality by isolating the load from input disturbances and providing additional safety. High Efficiency: Reduces energy costs and heat generation, contributing to a more sustainable operation. Advanced Battery Management: Prolongs battery life and ensures optimal performance through intelligent charging and discharging. LCD Display: Provides real-time monitoring of UPS status, including input/output voltage, load percentage, and battery status. Modular Design: Allows for easy maintenance and upgrades. Multiple Communication Ports: Includes RS-232, USB, and optional SNMP for remote monitoring and management. Applications: Data Centers: Ensures reliable power for critical IT infrastructure. Telecommunications: Protects sensitive telecom equipment from power disturbances. Medical Facilities: Supports essential medical equipment requiring uninterrupted power. Industrial Applications: Suitable for manufacturing and process control systems. Services: Engineering: Customized solutions for specific power requirements. Installation: Professional installation services to ensure proper setup. Preventive Maintenance: Regular maintenance to ensure optimal performance and reliability. Monitoring: Remote monitoring services to track UPS performance and health. Recycling: Environmentally responsible disposal of old batteries and equipment. Certifications: ISO 9001: Quality management system certification. ISO 14001: Environmental management system certification. ISO 45001: Occupational health and safety management system certification. CE: Conforms to European Union safety and environmental standards. UL: Conforms to Underwriters Laboratories safety standards. Warranty: Standard Warranty: Typically offers a 2-year warranty on the UPS system and batteries. Extended Warranty: Options for additional warranty coverage may be available. Additional Information: The Emerson Vertiv 6KVA Online UPS with an inbuilt isolation transformer is designed to meet the demanding power quality requirements of various industries. Its features ensure that critical systems remain operational even during power interruptions, making it a reliable choice for businesses that cannot afford downtime.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Amaron Car Battery

Amaron is also known for manufacturing high-quality car batteries. Their car batteries are designed to provide reliable performance, longer life, and are known for being maintenance-free. Here's a breakdown of the key features of Amaron Car Batteries: Key Features of Amaron Car Batteries: Maintenance-Free: Most of Amaron's car batteries are maintenance-free, meaning you don't need to top up the water level regularly, making them hassle-free to use. Long Life: Amaron batteries are built for longevity. They use advanced technology in their manufacturing process to ensure they last longer than standard car batteries. High Cranking Power: Amaron batteries are designed to offer high cranking power, which is important for starting your car, especially in extreme weather conditions. Durability: Amaron batteries are built to withstand the challenges of extreme heat and cold, making them durable and reliable in all kinds of climates. Vibration Resistance: The batteries are designed to be resistant to vibrations, which is important for vehicles that are driven on rough roads. Better Performance: Amaron batteries are equipped with advanced lead-calcium alloy technology, improving the overall performance and reliability of the battery. Warranty: Amaron offers a good warranty on its car batteries, generally ranging from 24 months to 48 months, depending on the model. Types of Amaron Car Batteries: Amaron Go: A popular line for regular cars and entry-level vehicles, offering solid performance at a competitive price. Amaron Flo: Known for its low-maintenance and enhanced performance features, ideal for newer cars with more advanced electrical systems. Amaron Pro: Designed for more premium cars or those with additional electrical demands, providing extra cranking power and extended life. Amaron Quanta: A high-performance option for commercial vehicles and larger applications. Benefits: Wide Range: Amaron has a broad selection of car batteries that suit various vehicle models and sizes. Reliable Performance: Their batteries provide consistent performance and are known for being able to withstand heavy use. Low Self-Discharge Rate: These batteries maintain charge longer, even when the car isn't used for an extended period.

Send Message
product image
ALL TYPES OF UPS REPAIR

UPS (Uninterruptible Power Supply) repair typically involves diagnosing and fixing issues related to power failures, battery problems, or malfunctioning components. Here are some common repair tasks: Battery Replacement: Batteries in UPS units degrade over time and may need replacing. This is one of the most common repairs. Power Supply Issues: Problems with the internal power supply circuit or malfunctioning capacitors can cause a UPS to fail to charge or provide backup power. Overheating Issues: Dust buildup or fan failure can cause the unit to overheat, requiring cleaning or fan replacement. Inverter and Charger Problems: If the UPS isn't converting DC to AC power properly, it could be an inverter problem. Similarly, charger failures could stop the battery from charging. Internal Component Replacement: This may involve replacing transformers, fuses, or circuit boards that have failed.

Send Message

Still searching for
heat generation?