Bhiwadi
+918076792323

'manufacturer recommendations'

Items tagged with 'manufacturer recommendations'

product image
Amaron Quanta 12V 18Ah Battery

The Amaron Quanta 12V 18Ah is a type of sealed lead-acid (SLA) battery, commonly used for backup power applications, such as in UPS systems, inverters, and other critical power supply systems. Here's a detailed breakdown of its specifications and features: 1. General Overview Brand: Amaron Quanta Battery Type: Sealed Lead-Acid (SLA) Battery Voltage: 12 Volts (V) Capacity: 18 Ampere-Hours (Ah) 2. Key Features Longer Battery Life: Amaron Quanta batteries are designed for long-lasting performance and high reliability. They typically offer a good lifespan, especially in applications with a low depth of discharge (DOD). Maintenance-Free: The battery is sealed, so it doesn’t require regular maintenance (e.g., adding water). Vibration Resistance: These batteries are designed to withstand vibrations, making them ideal for use in environments like telecoms, solar power, and UPS systems. Wide Operating Temperature: They can operate in a wide range of temperatures, typically from 0°C to 40°C, making them versatile for use in different climates. 3. Technical Specifications Voltage: 12V (Nominal) Capacity: 18Ah (Ampere-Hours) Dimensions: Length: 181 mm Width: 77 mm Height: 167 mm Weight: Around 5.2 to 5.5 kg (varies slightly based on exact model) Charge Voltage: 14.4V to 15.0V (during charging) Discharge Voltage: Typically 10.5V to 11.0V for complete discharge Self-discharge: Less than 3% per month at 25°C 4. Applications UPS Systems: The 12V 18Ah battery is widely used in smaller uninterruptible power supplies (UPS) for providing backup power to sensitive electronics. Inverters: It can also be used in small-scale inverters to provide backup power to homes or offices. Telecommunications: In telecom applications, these batteries can be used for backup power to critical network equipment. Solar Energy Storage: Sometimes used in small-scale solar energy systems for storing energy for use during off-sunlight hours. 5. Battery Design Features Valve Regulated Lead-Acid (VRLA): The Amaron Quanta battery uses VRLA technology, which means the battery is sealed and uses a valve to release gas in case of overpressure. Deep Cycle: Designed for regular deep discharge cycles, making it suitable for power backup applications where batteries frequently discharge. Absorbent Glass Mat (AGM): Some models use AGM technology, where the electrolyte is absorbed in a fiberglass mat, allowing the battery to be spill-proof and leak-proof. 6. Charge/Discharge Characteristics Charging: Amaron Quanta batteries typically use a constant voltage charge, with a float charge voltage of around 13.5V to 13.8V. Discharge: The battery can typically discharge down to around 10.5V under load, but frequent deep discharges can reduce the battery's overall lifespan. 7. Advantages Longer Service Life: Typically offers a long life when maintained and used properly, making it a cost-effective option for long-term use. Reliable Performance: Known for reliability in maintaining charge over time, especially in demanding environments. Environmentally Friendly: Sealed and maintenance-free design minimizes risks associated with acid leakage and spills. 8. Maintenance Maintenance-Free Design: As mentioned, the battery is sealed, so it doesn't require regular maintenance like adding distilled water. However, regular inspection for corrosion on terminals and proper charge maintenance is recommended. Charging Recommendations: Always charge the battery in accordance with the manufacturer’s recommendations. Overcharging or undercharging can significantly reduce the battery’s lifespan. 9. Warranty Amaron Quanta batteries often come with a warranty that covers defects in material or workmanship, which typically lasts for 1 to 2 years depending on the seller and country-specific terms. 10. Compatibility Compatible Devices: The Amaron Quanta 12V 18Ah battery is commonly used in small UPS systems, solar power applications, and other critical systems where consistent backup power is required. Charging Systems: Can be used with most standard 12V chargers designed for SLA or AGM batteries. Conclusion The Amaron Quanta 12V 18Ah battery is an ideal solution for users looking for a reliable, low-maintenance, and efficient power backup option in smaller systems. It is widely used in UPS systems, inverters, and telecommunications applications where it can provide critical backup power when needed.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
Ups And Batteries

Vertiv offers a range of UPS solutions tailored for different applications, including data centers, telecommunications, industrial environments, and more. Their systems are known for reliability, efficiency, and advanced features. Key Features of Vertiv UPS Systems Power Capacity: Various models available, ranging from small single-phase UPS (1 kVA) to large three-phase systems (up to 500 kVA or more). Topologies: Online Double-Conversion: Provides the highest level of protection by converting incoming AC to DC and then back to AC, ensuring clean and stable power. Line-Interactive: Adjusts voltage fluctuations without switching to battery, suitable for less critical applications. High Efficiency: Many models boast high efficiency ratings, often exceeding 95%, which reduces operational costs. Battery Options: Lead-Acid Batteries: Common and cost-effective, but heavier and shorter lifespan. Lithium-Ion Batteries: Increasingly available, offering longer life, lower weight, and higher efficiency. Modular Design: Some models are modular, allowing for scalable configurations that can grow with your power needs. Advanced Battery Management: Features to enhance battery lifespan, including temperature monitoring, equalization charging, and smart diagnostics. User-Friendly Interface: Intuitive LCD or LED displays for easy monitoring of power status, battery health, and load levels. Network Management: Options for SNMP or web-based monitoring allow for remote management of UPS performance. Parallel Operation: Supports parallel operation for redundancy and increased capacity. Battery Systems Types of Batteries Used: Lead-Acid Batteries: Sealed Lead Acid (SLA): Maintenance-free and widely used; available in various configurations. Valve-Regulated Lead Acid (VRLA): Designed to be more durable and safe. Lithium-Ion Batteries: Offer longer cycle life, lower weight, and better energy density. Can provide up to 10 years of life or more, depending on usage. Typical Specifications (Examples) Input Voltage: 380/400/415 V (three-phase). Output Voltage: 380/400/415 V (three-phase). Output Frequency: 50/60 Hz (auto-sensing). Efficiency: Up to 98% in eco-mode for certain models. Form Factor: Tower or rack-mounted options, based on the model. Benefits of Vertiv UPS with Batteries Reliability: Ensures uninterrupted power supply, crucial for mission-critical operations. Scalability: Easily expand capacity by adding additional UPS units or modules. Cost-Effectiveness: High efficiency leads to lower energy costs; predictive maintenance can help avoid costly downtime. Enhanced Protection: Maintains stable power output, protecting sensitive equipment from surges and outages. Proactive Monitoring: Remote monitoring capabilities allow for early detection of potential issues, improving uptime. Maintenance and Support Annual Maintenance Contracts (AMC): Regular inspections, preventive maintenance, and support services ensure optimal performance. Battery Replacement Services: Timely replacement of batteries as per usage and manufacturer recommendations is critical for maintaining efficiency and reliability. Conclusion Vertiv UPS systems paired with appropriate battery solutions provide a robust and efficient power protection strategy for various applications. With their focus on reliability, efficiency, and advanced features, Vertiv UPS systems are well-suited for mission-critical environments. If you need more specific information about particular models or configurations, feel free to ask!

Send Message
product image
UPS Repair

When it comes to Vertiv 10kVA UPS repair and testing, it involves several key processes to ensure that the UPS functions correctly and reliably. Below are the details regarding Vertiv 10kVA UPS repair and testing: Vertiv 10kVA UPS Repair Common Issues: Battery Failure: Batteries may degrade over time and need replacement. Inverter Problems: The inverter may fail to convert DC to AC power. Overheating: Excessive heat can damage internal components. Faulty Charging Circuit: Issues with the charging system can prevent batteries from charging properly. Software Failures: Problems with firmware can affect UPS functionality. Repair Process: Diagnosis: Use diagnostic tools to identify issues. Check for error codes or alerts on the UPS display. Component Testing: Test batteries for capacity and voltage. Inspect the inverter and charging circuits for faults. Replacement of Parts: Replace faulty batteries with new ones. Repair or replace damaged circuit boards, inverters, or other components. Calibration: Calibrate the UPS settings to ensure optimal performance. Final Testing: Conduct a load test to verify that the UPS can handle its rated capacity. Vertiv 10kVA UPS Testing Testing Procedures: Visual Inspection: Check for physical damage, loose connections, or corrosion. Battery Testing: Measure the voltage and capacity of the batteries. Conduct a discharge test to ensure batteries can hold a charge. Load Testing: Connect a load to the UPS and monitor its performance. Ensure that the UPS can supply power for the specified duration under load. Transfer Time Testing: Measure the time it takes for the UPS to switch from mains to battery power and back. Efficiency Testing: Assess the efficiency of the UPS under various loads to ensure it meets manufacturer specifications. Maintenance Recommendations Regular Maintenance: Schedule regular checks (at least annually) to ensure all components are functioning correctly. Battery Replacement: Replace batteries every 3-5 years, depending on usage and manufacturer recommendations. Firmware Updates: Keep the UPS firmware updated to benefit from the latest features and fixes. Conclusion Proper repair and testing of Vertiv 10kVA UPS systems are crucial for ensuring reliable power backup. Regular maintenance can prevent unexpected failures and extend the lifespan of the unit. If you require further details on specific models or repair services, feel free to ask!

Send Message
product image
Amaron Quanta Batteries In Baghanki Manesar

Amaron Quanta batteries are known for their reliability and performance, particularly in applications like UPS systems, solar power setups, and backup power. Here’s an overview of the different types and details of Amaron Quanta batteries: Key Features: Sealed Maintenance Free (SMF): No need for water topping or maintenance. Long Service Life: Designed for extended use and durability. High Performance: Capable of handling high discharge rates. Deep Cycle Capability: Suitable for applications requiring frequent deep discharges. Types of Amaron Quanta Batteries: Amaron Quanta 12V 7Ah Dimensions: Approximately 151 x 65 x 94 mm Weight: About 2.5 kg Applications: UPS, alarm systems, portable electronics. Amaron Quanta 12V 9Ah Dimensions: Approximately 150 x 65 x 95 mm Weight: About 3.0 kg Applications: UPS, small power tools, and backup lighting. Amaron Quanta 12V 18Ah Dimensions: Approximately 181 x 77 x 167 mm Weight: Around 5.5 kg Applications: UPS, solar energy systems, and telecommunications. Amaron Quanta 12V 26Ah Dimensions: Approximately 166 x 175 x 125 mm Weight: About 7.0 kg Applications: Larger UPS systems, solar inverters, and backup power systems. Amaron Quanta 12V 42Ah Dimensions: Approximately 198 x 165 x 170 mm Weight: About 12.5 kg Applications: High-capacity UPS systems, solar power systems, and security systems. Amaron Quanta 12V 65Ah Dimensions: Approximately 350 x 167 x 175 mm Weight: Around 19.0 kg Applications: Heavy-duty UPS, large solar installations, and industrial applications. Charging Recommendations: Charging Voltage: Typically between 14.4 to 15.0 volts. Charging Current: Should not exceed specified rates (e.g., for a 7Ah battery, keep under 1.5A; for a 42Ah, under 6A). Storage and Maintenance: Store in a cool, dry place. Keep the battery fully charged if not in use for long periods. Regularly inspect for physical damage or signs of wear. Safety Precautions: Avoid short-circuiting terminals. Handle with care to prevent damage. Follow manufacturer guidelines for safe usage. For precise specifications and any additional models, it’s advisable to check the official Amaron website or product datasheets

Send Message
product image
Exide 12V 42Ah SMF In Ashiana Village Bhiwadi

The Exide 12V 42Ah SMF (Sealed Maintenance Free) battery is a versatile option, commonly used in applications like UPS systems, solar power setups, and backup power systems. Here are the detailed specifications and features: Specifications: Voltage: 12 Volts Capacity: 42 Ah (Ampere-hours) Type: Sealed Maintenance Free (SMF) Chemistry: Lead-acid (VRLA - Valve Regulated Lead Acid) Dimensions: Approximately 198 mm (L) x 165 mm (W) x 170 mm (H) (dimensions may vary slightly by model) Weight: Around 12.5 to 13.5 kg Features: Maintenance-Free: No need for electrolyte checks or water refills, reducing maintenance effort. Leak-Proof Design: Safe to use in various orientations without leakage risk. Long Service Life: Engineered for durability and reliability over extended periods. High Discharge Rate: Capable of delivering quick bursts of power for demanding applications. Applications: Uninterruptible Power Supplies (UPS) Solar power systems Emergency lighting Security and alarm systems Small electric vehicles and scooters Charging Recommendations: Charging Voltage: Typically between 14.4 to 15.0 volts. Charging Current: Should not exceed 4.2A for optimal battery health. Storage and Maintenance: Store in a cool, dry location. Ensure the battery is kept fully charged if not used for long periods. Regularly check for any physical damage or corrosion. Safety Precautions: Avoid short-circuiting the terminals. Handle the battery with care to prevent damage. Follow all manufacturer guidelines for safe operation and handling. Always refer to the specific product datasheet or manufacturer guidelines for the most accurate and tailored information regarding the particular model you are using.

Send Message
product image
Exide 12V 26Ah SMF Battery In Alawapur Bawal

The Exide 12V 26Ah SMF (Sealed Maintenance Free) battery is designed for reliable power in various applications, including UPS systems, solar power setups, and backup power solutions. Here are the key details: Specifications: Voltage: 12 Volts Capacity: 26 Ah (Ampere-hours) Type: Sealed Maintenance Free (SMF) Chemistry: Lead-acid (VRLA - Valve Regulated Lead Acid) Dimensions: Approximately 166 mm (L) x 175 mm (W) x 125 mm (H) (dimensions may vary slightly by model) Weight: Around 7.0 to 8.0 kg Features: Maintenance-Free: No need to add water or check electrolyte levels. Leak-Proof Design: Safe operation in various orientations without risk of leakage. Long Service Life: Built for durability and reliable performance. High Discharge Rate: Capable of delivering quick bursts of power for demanding applications. Applications: Uninterruptible Power Supplies (UPS) Solar energy systems Emergency lighting Security systems Small electric vehicles and mobility aids Charging Recommendations: Charging Voltage: Generally between 14.4 to 15.0 volts. Charging Current: Should not exceed 2.6A for optimal battery lifespan. Storage and Maintenance: Store in a cool, dry environment. Ensure the battery is fully charged if not in use for extended periods. Regularly inspect for any signs of damage or wear. Safety Precautions: Avoid short-circuiting the terminals. Handle carefully to prevent physical damage. Follow all manufacturer instructions for safe use. For the most accurate information, always refer to the specific product datasheet or manufacturer guidelines related to your model.

Send Message
product image
Exide 12V 18Ah SMF In Ajit Nagar Faridabad

The Exide 12V 18Ah SMF (Sealed Maintenance Free) battery is a robust option for various applications like UPS systems, solar energy systems, and emergency backup power. Here are the key details: Specifications: Voltage: 12 Volts Capacity: 18 Ah (Ampere-hours) Type: Sealed Maintenance Free (SMF) Chemistry: Lead-acid (VRLA - Valve Regulated Lead Acid) Dimensions: Approximately 181 mm (L) x 77 mm (W) x 167 mm (H) (dimensions may vary slightly by model) Weight: Around 5.5 to 6.0 kg Features: Maintenance-Free: No need for electrolyte checks or water refills. Leak-Proof Design: Safe for use in various positions without leakage. Long Service Life: Designed for durability and reliable performance. High Discharge Rate: Suitable for applications requiring rapid power delivery. Applications: Uninterruptible Power Supplies (UPS) Solar power systems Emergency lighting systems Security systems Small electric vehicles and scooters Charging Recommendations: Charging Voltage: Typically between 14.4 to 15.0 volts. Charging Current: Should not exceed 1.8A for optimal battery health. Storage and Maintenance: Store in a cool, dry environment. Maintain a full charge if not in use for extended periods. Regularly check for any signs of damage or wear. Safety Precautions: Avoid short-circuiting terminals. Handle with care to prevent damage. Follow all manufacturer instructions for safe operation. For precise details and specifications, always refer to the specific product datasheet or manufacturer guidelines relevant to your model.

Send Message

Still searching for