product image
Microtek inverter In Bawal

Microtek inverters are popular for their reliability and efficiency in providing backup power solutions. Here are some key points: Types: Available in pure sine wave, square wave, and modified sine wave models to suit different needs. Applications: Used for home, office, and industrial backup power systems. Features: Energy-efficient, low maintenance, with features like digital display, smart charging, and battery management systems. Compatibility: Works well with various battery types, including lead-acid and lithium-ion. Durability: Built to withstand power fluctuations and extreme conditions. Microtek is known for its durable and cost-effective inverters, widely used across India and other regions.

Send Message
product image
Luminous Ups

The Luminous LD30KH-PRO is a high-performance Inverter designed to provide reliable backup power for homes, offices, and small commercial setups. It is a part of Luminous' Pure Sine Wave Inverter series, offering high efficiency and stable power supply to sensitive equipment like computers, refrigerators, air conditioners, and other appliances. Here are the key features and specifications of the Luminous LD30KH-PRO: Key Features: Power Capacity: 30 kVA (Kilovolt-Ampere) – It is designed to support large power loads, making it suitable for medium to large residential, commercial, or industrial applications. Pure Sine Wave Output: Provides clean and stable output voltage, ensuring that sensitive equipment (like computers, air conditioners, and medical equipment) operates without issues, such as noise or voltage fluctuations. High Efficiency: The inverter operates with high efficiency, which reduces power loss and ensures that more of the battery's energy is used to power connected appliances. Advanced Microprocessor Technology: The inverter uses a microprocessor-based design to ensure high performance, protection, and reliability. It optimizes charging and discharging cycles, as well as load management. User-Friendly LCD Display: It comes with an intuitive LCD display that shows important information such as battery status, power usage, input and output voltage, and fault conditions. This helps users easily monitor and manage the system. Wide Input Voltage Range: The inverter operates with a wide input voltage range, which helps it perform well under varying input conditions. This feature helps protect connected equipment from power surges and fluctuations. Multiple Protection Mechanisms: Built-in protection features include overload protection, short-circuit protection, deep discharge protection, and battery reverse polarity protection, which ensures the safety of the connected equipment. Battery Compatibility: The Luminous LD30KH-PRO is compatible with both lead-acid and lithium-ion batteries, giving users flexibility depending on their preferences for battery technology. Smart Battery Management: The inverter comes with intelligent battery management to optimize battery performance, extending their lifespan and ensuring safe charging and discharging cycles. Compact and Reliable Design: Designed with a compact form factor and a durable build, the inverter is ideal for both indoor and outdoor installations and can be used for both backup power and off-grid applications. Applications: Residential Homes – For providing backup power for large appliances like air conditioners, refrigerators, lighting, and electronics. Small and Medium Businesses – For ensuring uninterrupted power supply to computers, servers, and other essential equipment. Commercial Use – Ideal for large offices, small industries, and workshops. Rural/Off-Grid Areas – Can be used in places with frequent power outages or no access to the grid, providing a reliable power solution. Specifications Summary: Rated Capacity: 30 kVA Output Type: Pure Sine Wave Input Voltage: 120V – 300V (depending on model) Charging Current: Adjustable (depends on load) Display: LCD with detailed status updates Battery Compatibility: Compatible with lead-acid and lithium-ion batteries

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
5SC UPS

The Eaton 5SC UPS is designed for high-end residential, retail, and small business applications, offering reliable power protection. It features power ratings from 500 VA to 1500 VA, pure sine wave output, advanced LCD monitoring, and various connectivity options including USB and serial ports. Key Specifications: Power Ratings: 500 VA to 1500 VA Output: Pure sine wave Connectivity: USB, serial, and relay Battery Type: Sealed lead-acid, maintenance-free Dimensions: Varies by model Weight: Approximately 34 lbs to 50 lbs depending on the model For more detailed specifications and features, you can refer to the Eaton website or the technical datasheets available in the search results. The Eaton 5SC UPS is a reliable uninterruptible power supply designed to protect sensitive electronic equipment in various environments, including small businesses and home offices. Key Features: Power Ratings: Available in multiple configurations, including 500 VA, 750 VA, 1000 VA, 1500 VA Output Type: Pure sine wave output, ensuring compatibility with high-end workstations and storage systems Battery Technology: Utilizes sealed lead-acid batteries with Advanced Battery Management (ABM) technology, extending battery life by up to 50% Connectivity Options: Equipped with USB and serial ports for easy integration with various operating systems (Windows, Mac, Linux) Display: Features an advanced LCD screen that provides real-time information on battery status, load, and operating mode Design: Compact tower style with multiple battery-protected outlets (5-15R) and Automatic Voltage Regulation (AVR) Performance and Reliability: Run Time: Estimated run time varies based on load; for example, a 1500 VA unit can provide over an hour of backup for moderate loads Warranty: Comes with a 3-year warranty on the UPS system and internal batteries, along with a $150,000 load protection guarantee for connected equipment Noise Level: Generally quiet operation due to the absence of a fan, although some users report a low-level buzz from the unit User Experience: Setup: Users find the setup process straightforward, aided by clear instructions and a user-friendly interface Software: Companion software is available for configuration, though some users report it can be glitchy and recommend using built-in OS features instead Customer Feedback: Many customers appreciate the value for money, noting the unit's reliability and performance, while some have raised concerns about battery life and occasional noise during operation

Send Message
product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message
product image
3 KVA

SB MODEL & LB MODEL The Vertiv 3kVA UPS models in the SB (Standby) and LB (Line-Interactive) series are designed to provide power protection and backup for medium-sized equipment or small-to-medium office environments, server rooms, and critical infrastructure. Below are the detailed specifications and features for each of these series in the 3kVA range. 1. Vertiv 3kVA SB (Standby) Series UPS The SB Series for 3kVA is a basic uninterruptible power supply solution. The Standby topology is typically the most cost-effective option, ideal for environments that require minimal backup time and surge protection without sophisticated power regulation. Key Features: Topology: Standby (Off-line) UPS Power Rating: 3kVA / 3000VA Output Power: 1800W - 2400W (varies by model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% (standard for most regions) Waveform Type: Simulated Sinewave (approximate sinewave output) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) Battery Capacity: 12V, 9Ah, 12Ah, or higher (depending on model) Charging Time: Typically 4-8 hours for a full charge Backup Time (Runtime): Provides backup for 5-20 minutes depending on load (e.g., 60-70% load) Cooling: Fan-assisted cooling for heat dissipation Interfaces: USB/Serial ports (some models include monitoring software) Form Factor: Typically Tower form factor Additional Features: Surge protection (for protection against power spikes) Overload protection and short-circuit protection Battery and overload indicators (LED and audible alarms) Optional software for remote monitoring and automatic shutdown Compact design for easier deployment in small-to-medium businesses, home offices, or workstations Ideal Use Case: Home offices and small businesses needing reliable backup power and surge protection Low power devices like workstations, point-of-sale (POS) systems, small networking equipment Environments where minimal power conditioning and voltage regulation are required 2. Vertiv 3kVA LB (Line-Interactive) Series UPS The LB Series for 3kVA uses a Line-Interactive topology, providing more advanced protection and efficiency, making it ideal for environments where power quality and stability are essential. The line-interactive design offers better Automatic Voltage Regulation (AVR), correcting voltage fluctuations without switching to battery power. Key Features: Topology: Line-Interactive Power Rating: 3kVA / 3000VA Output Power: 2100W - 2700W (varies by model) Input Voltage: 140V - 300V (wider input range compared to the SB series) Output Voltage: 230V ± 10% (standard for most regions) Waveform Type: Simulated Sinewave (or Pure Sinewave on some models) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 9Ah, 12Ah, or higher (depending on model) Charging Time: 4-6 hours to fully charge the battery Backup Time (Runtime): 10-30 minutes depending on the load (e.g., for 50-60% load) Cooling: Fan-assisted cooling Interfaces: USB/Serial ports (for monitoring and management software) Form Factor: Tower or Rackmount (depending on the specific model) Additional Features: Automatic Voltage Regulation (AVR): Corrects minor voltage fluctuations without using battery power Cold Start Capability: Can start without mains power (useful during power failures) LCD Display (on some models) to show real-time UPS status, battery level, and load information Overload, short-circuit, and low-battery protection Smart battery management for enhanced performance and extended battery life Audible alarms for power events (e.g., low battery, overload, fault) Smart monitoring and remote management with optional software for logging events and automatic shutdown during extended power outages Ideal Use Case: Small-to-medium-sized servers, network equipment, and critical infrastructure requiring more advanced power protection Environments needing consistent power quality, such as server rooms, medical equipment, and point-of-sale systems Small businesses with sensitive equipment that requires more stable voltage levels and longer backup time

Send Message
product image
2 KVA UPS

Vertiv 2kVA UPS SB MODEL & LB MODEL The Vertiv 2kVA UPS models in the SB (Standby) and LB (Line-Interactive) series offer similar features to their 1kVA counterparts, but with higher power ratings to cater to larger or more demanding devices. Here are the general details for each series in the 2kVA range: 1. Vertiv 2kVA SB (Standby) Series UPS The SB Series for 2kVA is a basic UPS solution designed for small office and home office environments where power backup and protection from power surges are required for a range of devices. Key Features: Topology: Standby (Off-line) Power Rating: 2kVA / 2000VA Output Power: 1200W - 1600W (depending on model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (approximate sinewave output) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Approximately 4-8 hours for a full charge Backup Time (Runtime): Provides backup for 5-15 minutes depending on the load (e.g., for 60-80% load) Cooling: Fan-assisted cooling for heat dissipation Interfaces: USB or serial ports for monitoring (depending on model) Form Factor: Typically Tower Additional Features: Surge protection Overload and short-circuit protection Low battery, overload, and fault indicators Automatic shutdown feature with optional software Audible alarms for power events (e.g., overload, low battery, fault) Compact design for easier placement in home office or small business environments Ideal Use Case: Home offices and small businesses Workstations, point-of-sale (POS) systems, and network equipment Consumer electronics that need surge protection and limited backup time 2. Vertiv 2kVA LB (Line-Interactive) Series UPS The LB Series for 2kVA is a more robust and efficient option than the Standby series, suitable for more demanding applications. It provides better voltage regulation and a higher level of protection due to the line-interactive topology. Key Features: Topology: Line-Interactive Power Rating: 2kVA / 2000VA Output Power: 1400W - 1800W (varies by model) Input Voltage: 140V - 300V (wider input range than SB series) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (typically) or Pure Sinewave (depending on model) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Around 4-6 hours to fully charge the battery Backup Time (Runtime): Can provide backup for 10-20 minutes depending on load (typically for a 50-70% load) Form Factor: Tower or Rackmount (depending on model) Interfaces: USB and/or Serial port for monitoring and management (some models support software for auto-shutdown) Additional Features: Automatic Voltage Regulation (AVR) to correct voltage fluctuations Cold Start: Can be turned on without mains power (useful in power failure situations) Overload, short-circuit, and low battery protection LCD or LED display (on some models) for real-time monitoring of UPS status, battery level, load capacity, etc. Enhanced battery management and energy-saving features to extend battery lifespan Audio and visual alerts for power failures, overloads, and battery issues Smart monitoring and management with optional software for power event logging and automatic shutdown Ideal Use Case: Small to medium-sized servers, workstations, and network equipment Sensitive equipment needing more precise power regulation IT infrastructures that require more consistent and reliable power protection Critical devices where frequent voltage fluctuations or outages could damage equipment Conclusion: SB Series (2kVA): The SB Series is a more cost-effective option for users who need basic backup power and surge protection for small office or home use. It is ideal for lower-power devices and non-critical applications where voltage regulation isn't a priority. LB Series (2kVA): The LB Series provides more robust features, such as Automatic Voltage Regulation (AVR), better battery management, and longer runtime. This makes it a better option for users who need more reliable and consistent power, especially in small to medium business environments, servers, or critical systems where power fluctuations are more common.

Send Message
product image
1 KVA UPS

VERTIV 1kVA UPS SB MODEL & LB MODEL The Vertiv 1kVA UPS comes in various models, with common models being the SB (Standby) and LB (Line-Interactive) series. These are uninterruptible power supplies designed to provide backup power and protection for critical equipment like servers, networking devices, and other sensitive electronic systems. Let’s break down the general features and details of both SB and LB models in the 1kVA range. 1. Vertiv 1kVA SB (Standby) Series UPS The SB Series is typically a basic Standby UPS designed to offer essential protection for home office and small business applications. The main purpose of the SB UPS is to provide basic surge protection and power backup during outages. Key Features: Topology: Standby Power Rating: 1kVA / 1000VA Output Power: 600W - 800W (varies by specific model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% (for typical models) Waveform Type: Simulated Sinewave (basic sinewave approximation) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries Battery Capacity: 12V, 7Ah or 9Ah (depending on model) Charging Time: Typically 4-8 hours to fully charge the battery Run Time: Provides backup power for 5-15 minutes depending on the load Interfaces: Often includes USB or serial ports for monitoring (depending on model) Form Factor: Tower type, compact design Additional Features: Surge protection Automatic voltage regulation (AVR) Overload and short-circuit protection Low battery and overload indicators Fan-assisted cooling for efficient operation Ideal Use Case: Small offices, home offices, and workstations Network routers, modems, and smaller networking equipment Low power devices and equipment 2. Vertiv 1kVA LB (Line-Interactive) Series UPS The LB Series is a more advanced line-interactive UPS system, designed for more demanding applications that require better efficiency and more consistent power quality. Key Features: Topology: Line-Interactive Power Rating: 1kVA / 1000VA Output Power: 800W - 900W (varies by specific model) Input Voltage: 140V - 300V (wider input range compared to SB) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave or Pure Sinewave (depending on the model and configuration) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: 12V, 7Ah or 9Ah Charging Time: Around 4-6 hours for full charge Run Time: Offers longer backup time, depending on load (usually 10-20 minutes for 50-75% load) Form Factor: Tower or Rackmount (depending on model) Interfaces: USB/Serial ports for monitoring, sometimes includes software for automatic shutdown Additional Features: Automatic Voltage Regulation (AVR) for stabilizing voltage fluctuations Enhanced battery management to extend battery life Cold start capability (UPS can start without mains power) Overload protection LCD display for real-time status monitoring (on some models) Audible alarms for low battery, overload, and fault conditions Ideal Use Case: Small to medium-sized servers, workstations, and critical network equipment Sensitive medical equipment Point-of-sale (POS) systems Small business IT infrastructure

Send Message
product image
UPS

The VERTIV Liebert ITON CX 1000VA UPS is a line-interactive uninterruptible power supply designed for home and small office use. Below are the details regarding its unboxing and quick testing. Unboxing Details Packaging: The UPS comes securely packaged to prevent damage during transit. Ensure to check for any visible signs of damage upon receipt. Included Items: VERTIV Liebert ITON CX 1000VA UPS unit User manual and installation guide Power cord with UK outlet Warranty card Initial Inspection: Check the UPS for any physical damage. Verify that all components are included as per the manual. Quick Test Procedure Setup: Place the UPS in a well-ventilated area. Connect the power cord to the UPS and plug it into a wall outlet. Power On: Press the power button to turn on the UPS. Observe the LED indicators: Green Light: Indicates AC mode (normal operation). Red Light: Indicates a fault condition. Battery Mode Test: To test the battery mode, disconnect the UPS from the wall outlet. Ensure that the UPS switches to battery mode automatically. Check the runtime by connecting a load (e.g., a computer) and monitor how long the UPS can sustain power. Load Testing: Connect a load that draws approximately 120W (e.g., a standard desktop computer). Monitor the backup time, which should be around 30 minutes under this load. Recharge Time: After the test, reconnect the UPS to the wall outlet. Note that the typical recharge time is 6-8 hours to reach 90% capacity. Key Specifications Power Capacity: 1000 VA / 600 Watts Input Voltage: 220/230 VAC Output Waveform: Simulated Sine Wave Transfer Time: 2-6 ms Battery Type: 12 V / 7 Ah x 2 Typical Backup Time: 30 minutes at 120W load Dimensions: 369 x 141 x 160 mm Weight: 10 kg Conclusion The VERTIV Liebert ITON CX 1000VA UPS is a reliable solution for power protection in small setups. The unboxing and quick test confirm its functionality and performance, making it a suitable choice for users needing uninterrupted power supply for their electronic devices. Always refer to the user manual for detailed instructions and safety precautions.