Bhiwadi
+918076792323

'operate efficiently'

Items tagged with 'operate efficiently'

product image
Vertiv 600 Kva Ups

The Vertiv 600 kVA UPS models, such as the Liebert APM and EXL S1, offer specifications like transformer-free designs, high efficiency (up to 99%), and modular configurations. They support various input voltages and provide robust power management features, ensuring reliable performance for critical applications. Vertiv 600 kVA UPS Models Liebert EXL S1 Capacity: 600 kVA Efficiency: Optimized for maximum efficiency and power density Voltage Support: Typically supports 380/400/415 V three-phase systems Features: Transformer-free design, advanced power management Liebert NX Capacity Range: 225-600 kVA Modes: High efficiency in both Eco-mode and double conversion mode Note: This model has been discontinued but was known for its reliability and performance in critical power applications Key Specifications Input Voltage: Supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Modular Configurations: Options available for scalability and redundancy Cooling Options: Designed to operate efficiently in various environmental conditions Applications Ideal for data centers, telecommunications, and other critical infrastructure requiring uninterrupted power supply. Suitable for environments where high efficiency and reliability are paramount.

Send Message
product image
ALL TYPES UPS & BATTERIES AMC

An Annual Maintenance Contract (AMC) for UPS systems typically includes routine maintenance, repair services, and emergency support to ensure optimal performance. It covers inspections, battery maintenance, and high-priority assistance during breakdowns, helping to extend the lifespan of your UPS and batteries. For more specific details, you can refer to the links provided in the search results. UPS AMC Services Overview: Purpose of AMC: The AMC is designed to provide comprehensive support for UPS systems, ensuring they operate efficiently and reliably. This includes regular maintenance, emergency repairs, and technical assistance. Key Components of AMC: Routine Maintenance: Regular inspections and servicing to prevent issues before they arise. Repair Services: Quick response to any failures or malfunctions, minimizing downtime. Emergency Support: 24/7 assistance to address urgent issues. Types of AMC Plans: Platinum Plan: Covers all spare parts during maintenance, excluding natural calamities. High-priority assistance during breakdowns. Regular preventive maintenance and detailed reports with recommendations. Gold Plan: Similar to the Platinum plan but does not include standby units. Focuses on critical equipment maintenance. Silver Plan: Basic support with engineers and technical assistance only. Maintenance Schedule: Monthly Checks: Visual inspections of batteries and connections. Measurement of ambient temperature and humidity. Cleaning of the UPS environment. Quarterly Checks: Voltage measurement of each battery cell. Conductance testing for battery health. Yearly Checks: Torque measurement of all connections. Testing of interconnecting cable resistance. Importance of Battery Maintenance: Regular maintenance is crucial as battery failures account for a significant percentage of UPS failures. Environmental conditions can greatly affect battery life, with temperature fluctuations leading to reduced performance. Contact Information: For inquiries or to set up an AMC, you can reach out via: Email: info@universalpower.co.in Phone: 8744823336

Send Message
product image
black hiway

Amaron Black Hiway batteries are known for their durability and performance, designed to meet the demands of various vehicles. Here’s a comprehensive overview of their features and specifications: Overview Type: Automotive batteries suitable for a range of vehicles. Technology: Advanced zero-maint enance technology for hassle-free operation. Design: Engineered for tropical climates, ensuring reliability in high temperatures. Key Specifications Capacity Options: Available in various capacities, including 80 AH, 120 AH, and 150 AH. Voltage: Standard voltage of 12 V across models. Cold Cranking Amps (CCA): High CCA ratings, such as 950 CCA for certain models, ensuring reliable starts in cold conditions. Warranty and Support Warranty Period: Typically ranges from 24 to 42 months, depending on the model. Example: 24 months full replacement + 18 months pro-rata for some models. Customer Support: Amaron provides extensive customer support for battery maintenance and inquiries. Performance Features Maintenance-Free: Designed to require no water topping up, reducing maintenance efforts. Vibration Resistance: Built to withstand harsh conditions and vibrations, enhancing longevity. High Heat Technology: Specifically designed to operate efficiently in high-temperature environments. Popular Models HC620D31R: Known for its premium quality and long life. HC180D04R: Offers a balance of performance and affordability. NT800E41R: Features a capacity of 120 AH with a total warranty of 42 months. NTX00D04R: A robust option with 150 AH capacity and high CCA. Conclusion Amaron Black Hiway batteries are a reliable choice for automotive needs, offering a combination of advanced technology, high performance, and minimal maintenance requirements, making them suitable for various driving conditions and vehicle types.

Send Message
product image
20 KVA UPS

The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount). Here\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS: Key Features of the Vertiv Liebert GXT5-20KMVRT11UXLN: 1. Power Rating and Capacity: Power Rating: 20kVA / 20000VA Output Power: 16000W (16kW) at 208V (depending on load conditions) This provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure. 2. Voltage Configuration: Input Voltage: 208V (for 3-phase input) The GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements. 3. Topology: On-Line Double-Conversion: The GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection. This topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances. Zero transfer time from utility power to battery power ensures no downtime for connected equipment. 4. Waveform Type: Pure Sinewave Output: The UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference. 5. Battery Type and Runtime: Battery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems. External Battery Support: The Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications. Charging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity. 6. Runtime (Backup Time): The battery backup time will vary depending on the load. Here are some estimates: At 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes. At full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity. Extended runtime can be achieved with additional external battery cabinets. 7. Cooling: Fan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures. 8. Form Factor: Rackmount and Tower: The Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS. Rackmount form factor: 3U (for the rack version), designed for 19-inch rack installations. The rackmount option allows easy integration into standard server racks or data center environments. 9. Energy Efficiency and Certifications: Energy Star Certification: The Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation. It also has low total cost of ownership (TCO), thanks to its energy-efficient operation. High Efficiency Mode (Eco Mode): The UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit. 10. Interfaces and Monitoring: LCD Display: The UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status. Connectivity: USB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring. SNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network. Dry Contact Interface: Available for integration with building management or alert systems. 11. Advanced Features: Automatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity. Overload and Short-Circuit Protection: Protects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms. Smart Battery Management: The system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures. Audible Alarms: Provides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.

Send Message
product image
10KVA UPS

The Vertiv™ Liebert® GXE 6000-10000VA UPS is part of the Liebert GXE Series, which provides line-interactive power protection with advanced features, making it an ideal solution for small and medium-sized businesses, IT infrastructure, and critical equipment in need of reliable power backup. The Liebert GXE UPS offers features like Automatic Voltage Regulation (AVR), extended battery support, efficient performance, and compact design. Here are all the key details and specifications for the Vertiv™ Liebert® GXE 6000-10000VA UPS: Vertiv Liebert GXE 10000VA UPS (10kVA) Power Rating: 10kVA / 10000VA Output Power: 6000W to 8000W Input Voltage: 170V - 280V Output Voltage: 230V ± 10% Waveform: Simulated Sinewave (or Pure Sinewave for specific models) Battery Type: Sealed Lead-Acid (SLA) / VRLA Battery Capacity: Typically 12V, 18Ah or 24Ah (with external battery options) Charging Time: 4-6 hours for a full recharge Backup Time: 10-40 minutes depending on load and battery configuration Form Factor: Tower or Rackmount Interfaces: USB/Serial, SNMP (optional) Additional Features: AVR, Smart Battery Management, LCD Display, Overload Protection, Alarms, External Battery Support Key Features: Topology: Line-Interactive – This topology offers good protection and ensures that your equipment receives stable power during fluctuations, such as brownouts or overvoltages, without using battery power unnecessarily. Power Rating: 6kVA to 10kVA (6000VA to 10000VA) – Suitable for medium to large-sized IT infrastructure, servers, networking equipment, and other critical applications that need consistent and reliable power. Output Power: 6kVA (6000VA) models typically provide 3600W - 4800W of output power. 10kVA (10000VA) models provide 6000W - 8000W of output power, depending on the specific model and configuration. Input Voltage Range: 170V - 280V (wide input voltage range) – Provides protection from both high and low voltage fluctuations. Output Voltage: 230V ± 10% – Standard output voltage suitable for most business and IT applications. Waveform Type: Simulated Sinewave – In line-interactive mode, the output waveform is simulated sinewave. However, the UPS is designed to handle sensitive loads well. Automatic Voltage Regulation (AVR): The Liebert GXE UPS comes with AVR that corrects voltage fluctuations without switching to battery power, reducing battery wear and extending the overall life of the system. Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries – Commonly used for UPS systems due to their reliability and low maintenance. Battery Capacity: 12V batteries, with 18Ah, 24Ah, or higher capacity depending on the model and configuration. Extended Battery Support: The UPS can be connected to additional battery packs for longer backup runtimes if needed. Charging Time: Typically, the battery recharge time is around 4-6 hours for a full charge from a discharged state. Backup Time (Runtime): Backup time varies depending on load. For example: At 50% load, the runtime could range from 30 minutes to 1 hour. At full load, the backup time may range from 10-20 minutes, depending on the model and load. External Battery Packs can extend runtime significantly for longer power outages. Form Factor: Tower or Rackmount options are available, making the Liebert GXE adaptable for different environments, such as server rooms or small data centers. Rackmount models are designed for 19-inch racks and are ideal for installations in IT environments. Cooling: Fan-assisted cooling for efficient thermal management. Interfaces & Monitoring: USB/Serial Communication Ports for connection with monitoring and management software. SNMP Slot: Provides optional SNMP (Simple Network Management Protocol) support for remote monitoring and management. LCD Display: Many models include an LCD screen that shows real-time UPS status, load, battery condition, input/output voltage, and other important information. Smart Battery Management: Ensures that the batteries are efficiently charged and maintained, extending the life of the battery bank. Advanced battery diagnostics can help predict failures and improve overall UPS reliability. Overload Protection: Provides protection against equipment overload and ensures that the system shuts down or enters bypass mode in the event of a fault condition. Audible Alarms: Alarms provide real-time alerts for conditions like battery low, overload, fault conditions, and input/output abnormalities. Green Features: Energy-Efficient: Offers high energy efficiency to reduce operational costs. ECO Mode: In certain conditions, the system can operate in ECO mode to provide further energy savings, reducing electricity consumption.

Send Message
product image
Amaron Car Batteries

Amaron batteries are well-known in the automotive sector for their reliability and performance. Here’s a comprehensive overview of Amaron car batteries, including their features, types, specifications, and benefits. Amaron Car Batteries Overview Manufacturer: Amaron is a brand under the Amara Raja Batteries Ltd., one of India\'s leading battery manufacturers. Key Features Maintenance-Free: Amaron batteries are designed to be maintenance-free, eliminating the need for regular water topping and reducing user hassle. Long Life: Known for their durability, Amaron batteries often have a longer life cycle compared to conventional batteries. High Cranking Power: They offer excellent cold cranking amps (CCA), ensuring reliable starting power even in extreme weather conditions. Vibration Resistance: Engineered to withstand harsh conditions, Amaron batteries are resistant to vibrations and shocks, making them suitable for rugged environments. Fast Charging: Designed for efficient charging, they can recharge quickly, reducing downtime for users. Environmentally Friendly: Amaron batteries are designed to minimize environmental impact, adhering to stringent environmental regulations. Types of Amaron Batteries Amaron Flo (Flat Plate): These are conventional lead-acid batteries ideal for a range of vehicles, providing reliable performance. Amaron Hi-Life: A high-performance option designed for longer life and better endurance, suitable for SUVs and luxury vehicles. Amaron Pro: Targeted at heavy-duty applications, this battery type is built for commercial vehicles and heavy machinery. Amaron Black: Designed for entry-level vehicles, offering a good balance of performance and cost-effectiveness. Specifications (Typical) Voltage: 12V Capacity: Varies by model, typically ranging from 35Ah to 150Ah. Cold Cranking Amps (CCA): Varies by model; commonly from 300 to 800 CCA. Weight: Depends on capacity; usually between 10 kg and 60 kg. Design Life: Generally 3-5 years, with some premium models lasting longer. Benefits of Amaron Batteries Reliability: Amaron batteries are known for their dependable performance, making them a popular choice among consumers. Wide Range of Applications: Suitable for various vehicle types, including cars, SUVs, commercial vehicles, and two-wheelers. Cost-Effectiveness: Good value for money with a balance of performance and lifespan. Support and Warranty: Typically backed by a warranty period of 2 to 4 years, depending on the model. Maintenance Tips Regular Inspection: While they are maintenance-free, periodic checks for physical damage or corrosion can help ensure longevity. Clean Terminals: Keep battery terminals clean to avoid corrosion and ensure optimal performance. Proper Installation: Ensure correct installation to avoid damage and ensure the battery operates efficiently. Conclusion Amaron car batteries offer a reliable and efficient power source for various vehicles, known for their long lifespan, maintenance-free operation, and robustness. Whether for daily commuting or heavy-duty applications, Amaron provides a range of options to meet diverse automotive needs. If you need more specific information about particular models, pricing, or installation tips, feel free to ask!

Send Message
product image
Amaron Quanta 12V 42ah Smf Batteries With Vertiv 2Kva Ups

The Amaron 12V 42Ah battery is commonly used in various uninterruptible power supply (UPS) systems, including those from Vertiv. When paired with a Vertiv 2 kVA UPS, it provides reliable backup power for critical applications. Below are the details regarding both the Amaron battery and its application in a Vertiv 2 kVA UPS system. Amaron 12V 42Ah Battery Type: Sealed Lead Acid (SLA) battery, specifically designed for deep cycle applications. Voltage: Nominal Voltage: 12 Volts. Capacity: Ah Rating: 42 Ampere-hours (Ah), which indicates the battery's capacity to deliver a specific current for a certain period. Dimensions: Size: Typically around 9.5 x 5.5 x 8.5 inches (L x W x H), but this can vary by manufacturer. Weight: Approximately 30-35 lbs (13-16 kg), depending on the specific model and manufacturer. Construction: Maintenance-Free: The sealed design prevents leakage and reduces maintenance requirements. Durability: Designed to withstand vibrations and shocks, making it suitable for various environments. Discharge Characteristics: Cycle Life: Can typically provide around 300-500 cycles at 100% discharge, depending on usage and maintenance. Operating Temperature: Generally operates efficiently within a temperature range of -15°C to 50°C (5°F to 122°F). Vertiv 2 kVA UPS Power Rating: Capacity: 2 kVA (2000 VA) / typically around 1.6 kW output, depending on the power factor. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring maximum protection for connected equipment. Input Specifications: Input Voltage: Typically accepts 110-240 VAC. Input Frequency: 50/60 Hz (auto-sensing). Output Specifications: Output Voltage: Configurable, typically 220/230/240 VAC. Output Connections: Multiple IEC or NEMA outlets for connecting devices. Battery Compatibility: The 2 kVA UPS can be paired with multiple 12V batteries (like the Amaron 12V 42Ah) in series or parallel configurations to achieve the desired runtime and capacity. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 for management and monitoring. Some models may have SNMP options. Physical Dimensions: Size: Generally around 3U to 5U in height, depending on the specific model. Weight: Approximately 50-70 lbs (22-32 kg) for the UPS alone, excluding batteries. Applications The combination of the Amaron 12V 42Ah battery with a Vertiv 2 kVA UPS is ideal for protecting critical IT equipment, networking devices, and servers in small to medium-sized data centers, server rooms, and telecommunications environments. Summary The Amaron 12V 42Ah battery is a reliable choice for use in a Vertiv 2 kVA UPS, providing the necessary backup power to maintain operations during outages. The UPS offers advanced features like online double-conversion technology and real-time monitoring, ensuring that sensitive equipment remains protected. For the most accurate and specific details, including installation, configuration, and warranty information, it's advisable to refer to the official documentation from Vertiv and Amaron or consult with their respective representatives.

Send Message
product image
Battery

Amaron batteries are well-known for their performance and reliability in various applications, including automotive, UPS systems, and renewable energy setups. Here’s a comprehensive overview of charging Amaron batteries, covering methods, parameters, and best practices. Charging Amaron Batteries 1. Charging Methods: Constant Current (CC) Charging: The charger supplies a constant current until the battery reaches a predefined voltage. Commonly used for lead-acid batteries, ensuring a safe and efficient charge. Constant Voltage (CV) Charging: After reaching the target voltage, the charger maintains that voltage while the current decreases. This method is suitable for maintaining battery charge without overcharging. Smart Chargers: These chargers automatically adjust voltage and current based on the battery's state. They often include features like temperature compensation and multi-stage charging. 2. Charging Parameters: Voltage: For lead-acid Amaron batteries, the charging voltage typically ranges from 2.25V to 2.40V per cell. For a 12V battery (6 cells), this translates to about 13.5V to 14.4V. Current: The charging current should be set to 10-30% of the battery's capacity (C-rate). For example, a 100Ah battery should be charged at 10A to 30A. Temperature Compensation: Adjust the charging voltage based on the ambient temperature to avoid damage. Generally, for every degree Celsius above 25°C, reduce the charging voltage by 0.005V per cell. 3. Charging Stages: Bulk Charge: The initial phase where maximum current is applied to quickly charge the battery. This stage continues until the battery reaches approximately 70-80% of its capacity. Absorption Charge: The charger maintains a constant voltage, allowing the current to taper off as the battery approaches full charge. This phase ensures the battery reaches full capacity without overcharging. Float Charge: A lower voltage is maintained to keep the battery fully charged without overcharging. This is essential for maintaining the battery in a ready state for immediate use. Best Practices for Charging Amaron Batteries: Use the Right Charger: Always use a charger specifically designed for the type of battery you are charging (lead-acid, AGM, etc.). Avoid Deep Discharge: Regularly charge the battery to prevent deep discharges, which can shorten battery life. Monitor Temperature: Ensure the charging environment is within the recommended temperature range (typically 15°C to 25°C). Regular Maintenance: Periodically check the battery's state of charge and electrolyte levels (if applicable). Clean terminals and connections to ensure efficient charging. Follow Manufacturer Guidelines: Always refer to the specific charging instructions provided by Amaron for the particular battery model. Conclusion Proper charging of Amaron batteries is vital for maximizing their lifespan and performance. By following the recommended charging methods, parameters, and best practices, users can ensure that their batteries operate efficiently and reliably. If you have specific models in mind or need further details, feel free to ask!

Send Message
product image
UPS & BATTERIES MAINTENANCE IN SECTOR 55 NOIDA

Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring reliable performance and extending their lifespan. Here’s a comprehensive guide on UPS battery maintenance: 1. Regular Inspection Visual Checks: Inspect batteries for physical damage, leaks, or corrosion. Connections: Ensure that terminals and connections are tight and free from corrosion. 2. Battery Testing Load Testing: Conduct regular load tests to ensure batteries can handle the expected load. Voltage Checks: Measure the voltage of each battery regularly to identify weak cells. 3. Cleaning Dust and Debris: Keep the battery area clean and free from dust. Use a soft brush or cloth. Corrosion Removal: Clean any corrosion from terminals with a solution of baking soda and water. 4. Temperature Monitoring Operating Temperature: Keep batteries within the manufacturer’s recommended temperature range (typically 20-25°C). Ventilation: Ensure proper airflow around the batteries to prevent overheating. 5. Charging Practices Regular Charging: Ensure batteries are charged regularly, even if the UPS is not in use. Avoid Deep Discharge: Do not allow batteries to discharge below the recommended level. 6. Battery Replacement Age and Cycle Life: Be aware of the expected lifespan (usually 3-5 years for lead-acid batteries) and replace batteries as needed. Use OEM Batteries: Always replace with original equipment manufacturer (OEM) batteries to ensure compatibility. 7. Documentation and Logs Maintenance Log: Keep records of inspections, tests, and replacements. Battery Specifications: Document battery type, installation date, and capacity for reference. 8. Environmental Considerations Disposal: Follow local regulations for disposing of old batteries. Storage: Store spare batteries in a cool, dry place. 9. Professional Servicing Annual Maintenance: Consider scheduling annual inspections by a professional to assess battery health. 10. Safety Precautions Personal Protective Equipment (PPE): Always wear gloves and safety goggles when handling batteries. Emergency Procedures: Be familiar with emergency procedures in case of battery leaks or failures. By following these maintenance tips, you can ensure your UPS batteries operate efficiently and last longer. Regular upkeep is key to preventing unexpected failures and ensuring reliable power during outages.

Send Message

Still searching for
operate efficiently?