Amaron Quanta 12v 42Ah Battery

The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial. Key Features of Amaron Quanta 42Ah Battery: Capacity: 42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load. Technology: Maintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free. High Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter. Deep Cycle Battery: This is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently. Durability: Long Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored. High-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions. Design: Compact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern. Vibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings. Safety Features: Flame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction. Leak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety. Application Areas: UPS Systems: Provides backup power to computers, servers, and networking equipment. Inverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages. Solar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night. Warranty: The Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details. General Specifications: Voltage: 12V (standard for most UPS and inverter batteries). Capacity: 42Ah. Type: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat). Charging Voltage: Typically around 14.4 to 15.0V for 12V batteries. Nominal Voltage: 12V. Dimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model). Weight: Approximately 12-14 kg. Maintenance Tips for the Amaron Quanta 42Ah Battery: Regular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan. Storage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically. Clean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed. Avoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it. Check for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear. Battery Testing: To check the health of the Amaron Quanta 42Ah battery, you can follow these steps: Voltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V. Load Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation. Capacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold. Conclusion: The Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message
product image
Vertiv Online Ups

Vertiv offers a range of online UPS (Uninterruptible Power Supply) systems designed to provide reliable power protection for critical applications, including data centers, telecommunications, and industrial environments. Here’s a detailed overview of Vertiv's online UPS solutions, including key features, specifications, benefits, and maintenance practices. Vertiv Online UPS Overview Purpose: Online UPS systems are designed to ensure continuous and clean power supply by converting incoming AC power to DC and then back to AC. This process provides maximum protection against power disturbances such as surges, sags, and outages. Key Features Continuous Power Supply: Provides uninterrupted power during outages, ensuring that sensitive equipment remains operational. Double-Conversion Technology: Converts incoming AC to DC and back to AC, delivering stable and high-quality power output. High Efficiency: Many models boast efficiencies of 95% or higher, particularly in eco-mode, reducing energy costs. Scalability: Options for parallel operation allow for easy scaling of capacity by adding additional units. Advanced Battery Management: Features for monitoring battery health, optimizing performance, and extending battery life, including temperature and state of charge monitoring. User-Friendly Interface: LCD or LED displays provide real-time data on power status, battery health, and load levels. Network Management Capabilities: Integration with remote monitoring systems through SNMP, allowing for proactive management and alerts. Vibration and Shock Resistance: Designed to withstand harsh operating conditions, making them suitable for industrial environments. Flexible Input/Output Options: Supports various voltages and phases, accommodating different application requirements. Specifications (Typical) Input Voltage: 380/400/415 V (three-phase), with some models supporting single-phase. Output Voltage: 380/400/415 V (three-phase). Output Frequency: 50/60 Hz (auto-sensing). Capacity Range: Varies widely, from small systems (1 kVA) to large systems (up to 500 kVA or more). Efficiency: Typically 95% to 98%, depending on model and operating conditions. Form Factor: Available in tower or rack-mounted configurations. Benefits Reliability: Provides a stable power supply, protecting sensitive equipment from power disturbances. Improved Power Quality: Filters out electrical noise and provides clean power, which is crucial for IT and telecommunications equipment. Cost Savings: High efficiency reduces operational costs, and predictive maintenance can prevent costly downtime. Robust Performance: Designed for heavy loads and capable of maintaining performance under varying conditions. Remote Monitoring: Enables proactive management and quick response to potential issues, enhancing system reliability. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Includes cleaning, tightening connections, and replacing worn-out components as necessary. Battery Management: Monitor battery health, conduct load tests, and replace batteries according to manufacturer guidelines. Documentation: Maintain records of inspections, tests, and repairs to track system performance over time. Professional Support: Engage professional services for emergency repairs, technical support, and routine maintenance. Conclusion Vertiv's online UPS systems provide critical power protection for a variety of applications. With their advanced features, high efficiency, and robust design, they are ideal for ensuring reliable power in environments where uptime is essential. Proper maintenance and proactive management are key to maximizing performance and longevity. If you need more specific information about particular models, configurations, or any other aspect, feel free to ask!

Send Message
product image
Vertiv 500 kva Ups

The Vertiv 500 kVA UPS (Uninterruptible Power Supply) is a high-capacity power protection solution designed for industrial applications, data centers, and critical infrastructure. Here’s a detailed overview of its features, specifications, benefits, and maintenance practices. Vertiv 500 kVA UPS Overview Key Features High Power Capacity: Provides 500 kVA of power, suitable for large-scale applications requiring substantial backup power. Topologies: Online Double-Conversion: This design ensures continuous, clean, and stable power by converting incoming AC to DC and then back to AC, offering maximum protection against power disturbances. High Efficiency: Typically achieves efficiencies of 95% or higher, reducing energy consumption and operational costs. Scalability: Supports parallel operation with multiple units for increased redundancy and power capacity as your needs grow. Advanced Battery Management: Features for optimizing battery performance, including temperature monitoring, state of charge, and predictive diagnostics. User-Friendly Interface: LCD or LED displays provide real-time monitoring of power status, battery health, and load levels. Network Management Capabilities: Integration with network management systems for remote monitoring and control, often through SNMP or web interfaces. Vibration and Shock Resistance: Designed to withstand industrial environments, making it reliable for mission-critical applications. Multiple Input/Output Options: Flexible configurations to match various voltage and phase requirements. Specifications (Typical) Input Voltage: 380/400/415 V (Three-phase) Output Voltage: 380/400/415 V (Three-phase) Output Frequency: 50/60 Hz (auto-sensing) Efficiency: Up to 98% in eco mode. Dimensions: Varies by model; typically designed for rack or floor mounting. Weight: Can exceed 1000 kg, depending on configuration and battery type. Battery Types: Can support various battery technologies, including lead-acid and lithium-ion. Benefits Reliability: Ensures uninterrupted power supply and protects critical loads from power disturbances. Cost Savings: High efficiency leads to lower energy costs, while predictive maintenance helps avoid expensive downtimes. Enhanced Performance: Maintains stable output voltage and frequency, protecting sensitive equipment. Proactive Monitoring: Remote monitoring capabilities allow for early detection of potential issues, improving uptime and reliability. Robust Design: Built to withstand harsh industrial conditions, ensuring longevity and performance. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Cleaning, tightening connections, and replacing worn-out parts as needed. Battery Management: Monitor battery health, perform load tests, and replace batteries according to manufacturer guidelines. Documentation: Keep detailed records of maintenance, inspections, and performance metrics. Emergency Support: Engage professional services for emergency repairs and technical support when needed. Conclusion The Vertiv 500 kVA UPS is a robust solution designed for high-demand environments, ensuring reliable power protection for critical applications. With its advanced features and capabilities, it is ideal for data centers, industrial applications, and other mission-critical settings. Proper maintenance and proactive management can further enhance its performance and longevity. If you have specific questions or need additional details, feel free to ask!

Send Message
product image
Amaron Car Batteries

Amaron batteries are well-known in the automotive sector for their reliability and performance. Here’s a comprehensive overview of Amaron car batteries, including their features, types, specifications, and benefits. Amaron Car Batteries Overview Manufacturer: Amaron is a brand under the Amara Raja Batteries Ltd., one of India\'s leading battery manufacturers. Key Features Maintenance-Free: Amaron batteries are designed to be maintenance-free, eliminating the need for regular water topping and reducing user hassle. Long Life: Known for their durability, Amaron batteries often have a longer life cycle compared to conventional batteries. High Cranking Power: They offer excellent cold cranking amps (CCA), ensuring reliable starting power even in extreme weather conditions. Vibration Resistance: Engineered to withstand harsh conditions, Amaron batteries are resistant to vibrations and shocks, making them suitable for rugged environments. Fast Charging: Designed for efficient charging, they can recharge quickly, reducing downtime for users. Environmentally Friendly: Amaron batteries are designed to minimize environmental impact, adhering to stringent environmental regulations. Types of Amaron Batteries Amaron Flo (Flat Plate): These are conventional lead-acid batteries ideal for a range of vehicles, providing reliable performance. Amaron Hi-Life: A high-performance option designed for longer life and better endurance, suitable for SUVs and luxury vehicles. Amaron Pro: Targeted at heavy-duty applications, this battery type is built for commercial vehicles and heavy machinery. Amaron Black: Designed for entry-level vehicles, offering a good balance of performance and cost-effectiveness. Specifications (Typical) Voltage: 12V Capacity: Varies by model, typically ranging from 35Ah to 150Ah. Cold Cranking Amps (CCA): Varies by model; commonly from 300 to 800 CCA. Weight: Depends on capacity; usually between 10 kg and 60 kg. Design Life: Generally 3-5 years, with some premium models lasting longer. Benefits of Amaron Batteries Reliability: Amaron batteries are known for their dependable performance, making them a popular choice among consumers. Wide Range of Applications: Suitable for various vehicle types, including cars, SUVs, commercial vehicles, and two-wheelers. Cost-Effectiveness: Good value for money with a balance of performance and lifespan. Support and Warranty: Typically backed by a warranty period of 2 to 4 years, depending on the model. Maintenance Tips Regular Inspection: While they are maintenance-free, periodic checks for physical damage or corrosion can help ensure longevity. Clean Terminals: Keep battery terminals clean to avoid corrosion and ensure optimal performance. Proper Installation: Ensure correct installation to avoid damage and ensure the battery operates efficiently. Conclusion Amaron car batteries offer a reliable and efficient power source for various vehicles, known for their long lifespan, maintenance-free operation, and robustness. Whether for daily commuting or heavy-duty applications, Amaron provides a range of options to meet diverse automotive needs. If you need more specific information about particular models, pricing, or installation tips, feel free to ask!

Send Message
product image
UPS

Emerson offers a range of three-phase industrial UPS systems designed to provide reliable power protection for critical applications. Here are some key details typically associated with Emerson's three-phase UPS solutions: Key Features Power Capacity: Models often range from 10 kVA to several hundred kVA, catering to different industrial requirements. Topology: Many models utilize an online double-conversion topology, which ensures continuous power supply and zero transfer time during outages. Efficiency: High-efficiency ratings (up to 96% or more) help reduce energy costs and heat generation. Modular Design: Many systems allow for modular configurations, enabling easy scalability and redundancy. Smart Battery Management: Advanced battery management systems extend battery life and enhance performance. User Interface: LCD screens or touchscreen interfaces for real-time monitoring, diagnostics, and control. Communication Protocols: Various options for remote monitoring and integration, including SNMP, Modbus, and other industry-standard protocols. Input/Output Configuration: Flexible I/O options for different electrical environments, often with customizable settings. Applications Data centers Industrial automation systems Telecommunications Manufacturing facilities Critical power applications in healthcare Considerations Installation: Requires professional installation to ensure compliance with local electrical codes and optimal performance. Maintenance: Regular maintenance checks are necessary for reliability; consider a service contract for ongoing support. Load Assessment: Properly assess total load requirements to select the appropriate UPS capacity. Environmental Conditions: Ensure the UPS is suitable for the operating environment (temperature, humidity, etc.). Popular Models Emerson has various models within its UPS lineup, including: Liebert APM: Modular UPS systems known for scalability and high efficiency. Liebert EXL S1: High-density UPS for critical loads, offering excellent performance and efficiency. Conclusion When considering an Emerson three-phase industrial UPS, it's essential to evaluate specific needs, including power requirements, space constraints, and operational conditions. For the most accurate and detailed information, including specifications and installation requirements, consult Emerson's official documentation or contact a local representative. If you have specific models or features in mind, let me know!

Send Message
product image
UPS

The Vertiv Liebert Ita2 10 kVA is an online uninterruptible power supply (UPS) designed to provide reliable power protection for critical applications. Here are some key features and specifications: Key Features Power Capacity: 10 kVA, suitable for medium-sized equipment or applications. Phase Conversion: Can convert three-phase input to single-phase output and vice versa, making it versatile for various setups. Online Topology: Provides continuous power with no transfer time during power outages, ensuring critical systems remain operational. High Efficiency: Designed for energy efficiency, reducing operational costs while providing reliable power. Modular Design: Allows for scalability and easy maintenance. Smart Battery Management: Extends battery life and improves reliability. User-Friendly Interface: Typically includes an LCD display for monitoring and management. Communication Options: Often features various communication interfaces (USB, SNMP, etc.) for integration with monitoring systems. Applications Data centers IT infrastructure Telecommunications Medical equipment Industrial applications Considerations Installation: Ensure proper installation by qualified personnel to optimize performance and safety. Maintenance: Regular maintenance is essential for ensuring reliability and extending the lifespan of the UPS. Load Requirements: Assess the total load to determine if 10 kVA meets your needs. If you have specific questions or need more detailed information, feel free to ask!

Send Message
product image
UPS

The Vertiv Liebert EXM is a modular uninterruptible power supply (UPS) designed for critical applications requiring high availability and reliability. It is particularly suitable for data centers, telecommunications, and other environments where power continuity is essential. Below are the key details and specifications of the Vertiv Liebert EXM UPS: General Features: Modular Design: The Liebert EXM features a modular architecture, allowing for easy scalability. Users can add or remove power modules as needed to meet changing power requirements. High Efficiency: The UPS is designed for high efficiency, often exceeding 95% in double conversion mode, which helps reduce energy costs and heat generation. Flexible Configuration: Available in various configurations, including single-phase and three-phase outputs, to accommodate different applications and environments. Advanced Monitoring: Equipped with advanced monitoring and management features, including a user-friendly LCD display and network management capabilities, allowing for remote monitoring and control. Redundancy: Supports N+1 redundancy, ensuring that if one module fails, the remaining modules can continue to provide power without interruption. Hot-Swap Capability: Modules can be replaced or serviced without shutting down the UPS, ensuring continuous operation. Smart Battery Management: Features intelligent battery management systems that optimize battery performance and lifespan. Specifications: While specific specifications can vary based on the model and configuration, here are common specifications for the Liebert EXM UPS: Power Ratings: Typically available in configurations ranging from 10 kVA to 40 kVA per module, with the ability to scale up to higher capacities by adding modules. Input Voltage: 380/400/415V three-phase (configurable). Output Voltage: 380/400/415V three-phase (configurable). Frequency: 50/60 Hz (auto-sensing). Efficiency: Up to 95% in double conversion mode and even higher in eco-mode operation. Battery Type: Typically uses valve-regulated lead-acid (VRLA) batteries, with options for lithium-ion batteries in some configurations. Operating Temperature: Generally operates in the range of 0°C to 40°C (32°F to 104°F). Dimensions: Varies based on the configuration and number of modules; typically, a standard 10 kVA module might have dimensions around 600 mm (W) x 800 mm (D) x 2000 mm (H). Weight: Weight varies by configuration but can range from 50 kg to over 200 kg for larger systems. Applications: Data Centers: Ideal for protecting critical IT infrastructure from power disruptions. Telecommunications: Ensures reliable power for telecom equipment and networks. Industrial Applications: Suitable for manufacturing and process control systems requiring uninterrupted power. Healthcare: Provides backup power for critical medical equipment and systems. Warranty and Support: Vertiv typically offers a standard warranty period for its UPS systems, which may vary by region and model. Extended warranty and service plans are often available. Maintenance Tips: Regular Testing: Conduct regular testing of the UPS and batteries to ensure proper operation. Firmware Updates: Keep the UPS firmware updated to benefit from the latest features and improvements. Environmental Monitoring: Ensure the UPS is installed in a suitable environment, with adequate cooling and ventilation. Conclusion: The Vertiv Liebert EXM UPS is a robust and flexible solution for critical power applications, offering high efficiency, modularity, and advanced monitoring capabilities. For specific models, configurations, and detailed specifications, it is advisable to consult the manufacturer\'s documentation or contact a Vertiv representative.