Bhiwadi
+918076792323

'sale systems'

Items tagged with 'sale systems'

product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
6 KVA UPS

The Vertiv 6kVA UPS models are available in both the SB (Standby) and LB (Line-Interactive) series, as well as other more advanced series, such as the On-Line (Double Conversion) series, which are designed for higher power loads and more demanding applications. Below is a breakdown of the 6kVA UPS options from Vertiv, highlighting the SB, LB, and other potential variants, including their key features, specifications, and ideal use cases. Vertiv 6kVA LB (Line-Interactive) Series UPS The LB Series for 6kVA is more advanced than the SB Series, using a Line-Interactive topology that corrects voltage fluctuations without switching to battery power. This is ideal for environments where power stability is critical, and provides more reliable protection for sensitive equipment. Key Features: Topology: Line-Interactive Power Rating: 6kVA / 6000VA Output Power: 4200W - 5400W (depending on model) Input Voltage: 140V - 300V (wider input range than SB series) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (or Pure Sinewave, depending on model) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: 12V, 18Ah, 24Ah, or higher (depending on model) Charging Time: 4-6 hours for full charge Backup Time (Runtime): 10-30 minutes depending on load (e.g., 50-70% load) Cooling: Fan-assisted cooling for high-efficiency operation Interfaces: USB/Serial ports (with optional software for remote monitoring and automatic shutdown) Form Factor: Tower or Rackmount (depending on specific model) Additional Features: Automatic Voltage Regulation (AVR): Helps correct voltage fluctuations (e.g., brownouts or surges) without using battery power Cold Start: Can be turned on without mains power (useful during power failures) LCD/LED Display (on some models): Real-time monitoring of UPS status, battery level, load capacity, etc. Overload, short-circuit, and low-battery protection Smart battery management to extend battery life and improve performance Audible alarms for low battery, overload, and fault events Advanced monitoring and remote management (via optional software) Ideal Use Case: Small-to-medium-sized servers, network equipment, and critical business infrastructure Medical equipment, point-of-sale (POS) systems, and sensitive electronics requiring stable power quality IT infrastructure in small businesses needing both battery backup and protection against power fluctuations Vertiv 6kVA On-Line (Double Conversion) Series UPS The On-Line (Double Conversion) series is the most robust and efficient series, providing true double-conversion power protection. This topology is designed to offer continuous clean and stable power to sensitive equipment, protecting it from all power disturbances including blackouts, brownouts, and voltage surges. Key Features: Topology: On-Line (Double Conversion) Power Rating: 6kVA / 6000VA Output Power: 4800W - 5400W (depending on the model) Input Voltage: 110V - 300V (wide input range) Output Voltage: 230V ± 2% (pure sinewave output) Waveform Type: Pure Sinewave Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 18Ah, or 24Ah, with external battery options for longer runtimes Charging Time: 4-6 hours for full charge Backup Time (Runtime): 20-40 minutes depending on load (e.g., 50-60% load) Cooling: Advanced fan-assisted cooling with efficient heat dissipation Interfaces: USB/Serial ports, RS-232, SNMP for remote monitoring and management Form Factor: Tower or Rackmount Additional Features: Double Conversion: Provides continuous, clean power from the UPS’s inverter, ensuring zero transfer time during power disturbances High Efficiency Mode: Switches to energy-efficient operation during stable power conditions while ensuring seamless transition to double conversion during power failure LCD/LED Display: Provides real-time status of the UPS, battery health, load capacity, etc. Remote Monitoring: Integrated SNMP or optional software for proactive monitoring and automated shutdown Overload and short-circuit protection Extended Battery Options: External battery packs for longer runtime in high-demand applications

Send Message
product image
3 KVA

SB MODEL & LB MODEL The Vertiv 3kVA UPS models in the SB (Standby) and LB (Line-Interactive) series are designed to provide power protection and backup for medium-sized equipment or small-to-medium office environments, server rooms, and critical infrastructure. Below are the detailed specifications and features for each of these series in the 3kVA range. 1. Vertiv 3kVA SB (Standby) Series UPS The SB Series for 3kVA is a basic uninterruptible power supply solution. The Standby topology is typically the most cost-effective option, ideal for environments that require minimal backup time and surge protection without sophisticated power regulation. Key Features: Topology: Standby (Off-line) UPS Power Rating: 3kVA / 3000VA Output Power: 1800W - 2400W (varies by model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% (standard for most regions) Waveform Type: Simulated Sinewave (approximate sinewave output) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) Battery Capacity: 12V, 9Ah, 12Ah, or higher (depending on model) Charging Time: Typically 4-8 hours for a full charge Backup Time (Runtime): Provides backup for 5-20 minutes depending on load (e.g., 60-70% load) Cooling: Fan-assisted cooling for heat dissipation Interfaces: USB/Serial ports (some models include monitoring software) Form Factor: Typically Tower form factor Additional Features: Surge protection (for protection against power spikes) Overload protection and short-circuit protection Battery and overload indicators (LED and audible alarms) Optional software for remote monitoring and automatic shutdown Compact design for easier deployment in small-to-medium businesses, home offices, or workstations Ideal Use Case: Home offices and small businesses needing reliable backup power and surge protection Low power devices like workstations, point-of-sale (POS) systems, small networking equipment Environments where minimal power conditioning and voltage regulation are required 2. Vertiv 3kVA LB (Line-Interactive) Series UPS The LB Series for 3kVA uses a Line-Interactive topology, providing more advanced protection and efficiency, making it ideal for environments where power quality and stability are essential. The line-interactive design offers better Automatic Voltage Regulation (AVR), correcting voltage fluctuations without switching to battery power. Key Features: Topology: Line-Interactive Power Rating: 3kVA / 3000VA Output Power: 2100W - 2700W (varies by model) Input Voltage: 140V - 300V (wider input range compared to the SB series) Output Voltage: 230V ± 10% (standard for most regions) Waveform Type: Simulated Sinewave (or Pure Sinewave on some models) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 9Ah, 12Ah, or higher (depending on model) Charging Time: 4-6 hours to fully charge the battery Backup Time (Runtime): 10-30 minutes depending on the load (e.g., for 50-60% load) Cooling: Fan-assisted cooling Interfaces: USB/Serial ports (for monitoring and management software) Form Factor: Tower or Rackmount (depending on the specific model) Additional Features: Automatic Voltage Regulation (AVR): Corrects minor voltage fluctuations without using battery power Cold Start Capability: Can start without mains power (useful during power failures) LCD Display (on some models) to show real-time UPS status, battery level, and load information Overload, short-circuit, and low-battery protection Smart battery management for enhanced performance and extended battery life Audible alarms for power events (e.g., low battery, overload, fault) Smart monitoring and remote management with optional software for logging events and automatic shutdown during extended power outages Ideal Use Case: Small-to-medium-sized servers, network equipment, and critical infrastructure requiring more advanced power protection Environments needing consistent power quality, such as server rooms, medical equipment, and point-of-sale systems Small businesses with sensitive equipment that requires more stable voltage levels and longer backup time

Send Message
product image
2 KVA UPS

Vertiv 2kVA UPS SB MODEL & LB MODEL The Vertiv 2kVA UPS models in the SB (Standby) and LB (Line-Interactive) series offer similar features to their 1kVA counterparts, but with higher power ratings to cater to larger or more demanding devices. Here are the general details for each series in the 2kVA range: 1. Vertiv 2kVA SB (Standby) Series UPS The SB Series for 2kVA is a basic UPS solution designed for small office and home office environments where power backup and protection from power surges are required for a range of devices. Key Features: Topology: Standby (Off-line) Power Rating: 2kVA / 2000VA Output Power: 1200W - 1600W (depending on model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (approximate sinewave output) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Approximately 4-8 hours for a full charge Backup Time (Runtime): Provides backup for 5-15 minutes depending on the load (e.g., for 60-80% load) Cooling: Fan-assisted cooling for heat dissipation Interfaces: USB or serial ports for monitoring (depending on model) Form Factor: Typically Tower Additional Features: Surge protection Overload and short-circuit protection Low battery, overload, and fault indicators Automatic shutdown feature with optional software Audible alarms for power events (e.g., overload, low battery, fault) Compact design for easier placement in home office or small business environments Ideal Use Case: Home offices and small businesses Workstations, point-of-sale (POS) systems, and network equipment Consumer electronics that need surge protection and limited backup time 2. Vertiv 2kVA LB (Line-Interactive) Series UPS The LB Series for 2kVA is a more robust and efficient option than the Standby series, suitable for more demanding applications. It provides better voltage regulation and a higher level of protection due to the line-interactive topology. Key Features: Topology: Line-Interactive Power Rating: 2kVA / 2000VA Output Power: 1400W - 1800W (varies by model) Input Voltage: 140V - 300V (wider input range than SB series) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (typically) or Pure Sinewave (depending on model) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Around 4-6 hours to fully charge the battery Backup Time (Runtime): Can provide backup for 10-20 minutes depending on load (typically for a 50-70% load) Form Factor: Tower or Rackmount (depending on model) Interfaces: USB and/or Serial port for monitoring and management (some models support software for auto-shutdown) Additional Features: Automatic Voltage Regulation (AVR) to correct voltage fluctuations Cold Start: Can be turned on without mains power (useful in power failure situations) Overload, short-circuit, and low battery protection LCD or LED display (on some models) for real-time monitoring of UPS status, battery level, load capacity, etc. Enhanced battery management and energy-saving features to extend battery lifespan Audio and visual alerts for power failures, overloads, and battery issues Smart monitoring and management with optional software for power event logging and automatic shutdown Ideal Use Case: Small to medium-sized servers, workstations, and network equipment Sensitive equipment needing more precise power regulation IT infrastructures that require more consistent and reliable power protection Critical devices where frequent voltage fluctuations or outages could damage equipment Conclusion: SB Series (2kVA): The SB Series is a more cost-effective option for users who need basic backup power and surge protection for small office or home use. It is ideal for lower-power devices and non-critical applications where voltage regulation isn't a priority. LB Series (2kVA): The LB Series provides more robust features, such as Automatic Voltage Regulation (AVR), better battery management, and longer runtime. This makes it a better option for users who need more reliable and consistent power, especially in small to medium business environments, servers, or critical systems where power fluctuations are more common.

Send Message
product image
1 KVA UPS

VERTIV 1kVA UPS SB MODEL & LB MODEL The Vertiv 1kVA UPS comes in various models, with common models being the SB (Standby) and LB (Line-Interactive) series. These are uninterruptible power supplies designed to provide backup power and protection for critical equipment like servers, networking devices, and other sensitive electronic systems. Let’s break down the general features and details of both SB and LB models in the 1kVA range. 1. Vertiv 1kVA SB (Standby) Series UPS The SB Series is typically a basic Standby UPS designed to offer essential protection for home office and small business applications. The main purpose of the SB UPS is to provide basic surge protection and power backup during outages. Key Features: Topology: Standby Power Rating: 1kVA / 1000VA Output Power: 600W - 800W (varies by specific model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% (for typical models) Waveform Type: Simulated Sinewave (basic sinewave approximation) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries Battery Capacity: 12V, 7Ah or 9Ah (depending on model) Charging Time: Typically 4-8 hours to fully charge the battery Run Time: Provides backup power for 5-15 minutes depending on the load Interfaces: Often includes USB or serial ports for monitoring (depending on model) Form Factor: Tower type, compact design Additional Features: Surge protection Automatic voltage regulation (AVR) Overload and short-circuit protection Low battery and overload indicators Fan-assisted cooling for efficient operation Ideal Use Case: Small offices, home offices, and workstations Network routers, modems, and smaller networking equipment Low power devices and equipment 2. Vertiv 1kVA LB (Line-Interactive) Series UPS The LB Series is a more advanced line-interactive UPS system, designed for more demanding applications that require better efficiency and more consistent power quality. Key Features: Topology: Line-Interactive Power Rating: 1kVA / 1000VA Output Power: 800W - 900W (varies by specific model) Input Voltage: 140V - 300V (wider input range compared to SB) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave or Pure Sinewave (depending on the model and configuration) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: 12V, 7Ah or 9Ah Charging Time: Around 4-6 hours for full charge Run Time: Offers longer backup time, depending on load (usually 10-20 minutes for 50-75% load) Form Factor: Tower or Rackmount (depending on model) Interfaces: USB/Serial ports for monitoring, sometimes includes software for automatic shutdown Additional Features: Automatic Voltage Regulation (AVR) for stabilizing voltage fluctuations Enhanced battery management to extend battery life Cold start capability (UPS can start without mains power) Overload protection LCD display for real-time status monitoring (on some models) Audible alarms for low battery, overload, and fault conditions Ideal Use Case: Small to medium-sized servers, workstations, and critical network equipment Sensitive medical equipment Point-of-sale (POS) systems Small business IT infrastructure

Send Message
product image
Vertiv 3 Kva Single Phase Ups

The Vertiv 3 kVA single-phase UPS is designed to provide reliable power protection for small to medium-sized applications, such as servers, telecommunications equipment, and sensitive electronic devices. Here’s a comprehensive overview of its key features, specifications, and applications: Key Features Reliable Power Protection: Offers stable and clean power to protect critical equipment from surges, sags, and outages. Compact Design: Ideal for environments with limited space, easily fitting into small racks or on desktops. High Efficiency: Many models boast efficiency ratings of over 90%, reducing energy costs. User-Friendly Interface: Often includes an LCD display for easy monitoring of battery status, load levels, and UPS health. Extended Battery Life: Intelligent battery management systems help prolong battery lifespan and optimize performance. Multiple Connectivity Options: Typically includes USB and RS-232 ports for monitoring and management. Specifications (Typical Vertiv 3 kVA Model) Power Rating: 3 kVA / 2.4 kW Input Voltage: 230V single-phase Output Voltage: 230V single-phase Input Frequency: 50/60 Hz (auto-sensing) Efficiency: Generally exceeds 90% in online mode Battery Type: Typically uses valve-regulated lead-acid (VRLA) or lithium-ion batteries Form Factor: Tower configuration for easy placement Communication Interfaces: USB, RS-232, with optional SNMP for network management Applications Small Business Environments: Provides backup power for computers, POS systems, and other critical devices. Home Offices: Protects home office equipment from power disruptions. Telecommunications: Ensures the reliability of communication devices and networks. Retail Applications: Supports electronic point-of-sale systems and other sensitive electronics. Conclusion The Vertiv 3 kVA single-phase UPS is designed for reliability and efficiency, making it an excellent choice for various small to medium-sized applications. For specific models and detailed technical specifications, it's advisable to refer to the Vertiv website or contact a local distributor. If you have specific questions about a particular model or need more details, feel free to ask!

Send Message
product image
UPS

The Emerson/Vertiv 1kVA UPS is a single-phase uninterruptible power supply solution that offers premium power outage protection and continuous power conditioning. It has a true online double conversion topology, ensuring high reliability and efficiency. Technical Specifications **Brand **: Emerson/Vertiv Model Name/Number: 1kVA UPS Capacity: 1kVA/ 0.8KW (1in - 1out) Input Voltage: 140-300VAC at 100% load; 100VAC - 300VAC on 50% load Output Voltage: 230VAC (single phase) Application Areas Small to Medium-Sized Businesses Home Offices Small Server Rooms Point of Sale (POS) Systems ATMs Medical Equipment Security Systems Telecom Reliability in a Compact Footprint Fully-digital control with high output voltage precision Manages all the nine power problems including sagging, spikes, and fluctuations Built-in Ethernet port includes compatibility with intelligent cards (SIC card, RDU_SIC cards, etc.,) with browser support Built-in-power charger for fast charging reduces battery charging time Prolonged backup time through cascaded connection

Send Message
product image
Vertiv 3 kVA UPS In Rohini Delhi

The Vertiv 3 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection and backup for critical equipment, making it ideal for IT environments, data centers, and small to medium enterprises. Here are the key details: Specifications: Power Rating: 3 kVA (approximately 2400 watts, depending on the power factor) Input Voltage: Generally operates within a range of 160-300 VAC. Output Voltage: Commonly 220/230/240 VAC. Output Waveform: Pure sine wave, ensuring compatibility with sensitive electronic devices. Battery Type: Typically uses sealed lead-acid or lithium-ion batteries (model-dependent). Features: Automatic Voltage Regulation (AVR): Stabilizes output voltage, protecting against surges and sags. LCD Display: Provides real-time monitoring of battery status, load levels, and input/output voltage. Multiple Outlets: Usually equipped with multiple output sockets for connecting various devices. Communication Ports: USB, RS-232, or network management ports for monitoring and management via software. Hot-Swappable Batteries: Allows for battery replacement without the need to power down the UPS. Applications: IT Equipment: Ideal for servers, switches, and networking equipment. Small to Medium Enterprises: Suitable for office equipment, point-of-sale systems, and workstations. Telecommunications: Used to provide backup power for telecom equipment. Advantages: Reliable Power Backup: Ensures continuous operation during power interruptions, minimizing data loss and downtime. Compact Design: Space-efficient design for easy installation in various environments. Energy Efficiency: Many models feature energy-saving modes and high efficiency. Considerations: Battery Runtime: Assess the expected runtime based on the total load connected; higher loads will decrease runtime. Maintenance: Regular maintenance and timely battery replacements are crucial for optimal performance. Always refer to the specific model’s user manual for detailed specifications, features, and installation instructions to ensure proper use and maintenance.

Send Message
product image
Vertiv 2 kVA UPS In Patel Nagar Gurgaon

The Vertiv 2 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable backup power and protection for various electronic devices, making it suitable for both IT and industrial applications. Here are the key details: Specifications: Power Rating: 2 kVA (approximately 1600 watts, depending on the power factor) Input Voltage: Typically operates within a range of 160-300 VAC. Output Voltage: Commonly 220/230/240 VAC. Output Waveform: Pure sine wave for compatibility with sensitive equipment. Battery Type: Generally sealed lead-acid or lithium-ion (varies by model). Features: Automatic Voltage Regulation (AVR): Protects against voltage fluctuations by stabilizing the output. LCD Display: Provides real-time data on battery status, load level, and input/output voltage. Multiple Outlets: Usually includes several output sockets for connecting multiple devices. Communication Ports: USB, RS-232, or network management options for monitoring and management. Hot-Swappable Batteries: Enables battery replacement without shutting down the UPS. Applications: IT Infrastructure: Ideal for servers, networking equipment, and critical computing systems. Small to Medium Enterprises: Suitable for point-of-sale systems, office equipment, and telecommunications. Industrial Use: Can be used for powering essential equipment in various industrial settings. Advantages: Reliable Backup Power: Ensures continuity during power outages, preventing data loss and downtime. Compact and Efficient: Designed for easy installation and energy efficiency. Scalability: Can be used in conjunction with other UPS systems for larger setups. Considerations: Battery Runtime: Evaluate the expected runtime based on the connected load; larger loads will reduce runtime. Maintenance: Regular maintenance checks and timely battery replacements are essential for performance. Always consult the specific model’s user manual for detailed specifications, features, and installation instructions tailored to your needs.

Send Message

Still searching for
sale systems?