Bhiwadi
+918076792323

'short term high power loads'

Items tagged with 'short term high power loads'

product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Battery

The Amaron Quanta 12V 12Ah battery is part of Amaron's lineup of high-performance lead-acid batteries, designed for various applications including uninterruptible power supply (UPS) systems, solar energy storage, and other backup power requirements. Here are the key details and specifications of the Amaron Quanta 12V 12Ah battery: 1. General Specifications: Model: Amaron Quanta 12V 12Ah Voltage: 12V (nominal) Capacity: 12Ah (Ampere-hours) Chemistry: Lead-Acid (Flooded or VRLA - Valve Regulated Lead Acid, depending on the specific model variant) Type: Sealed Lead Acid (SLA) or VRLA (Valve-Regulated Lead Acid) 2. Dimensions: Length: Approximately 151 mm Width: Approximately 65 mm Height: Approximately 94 mm Weight: Approximately 3.8 kg (8.38 lbs) 3. Applications: UPS Systems: Ideal for providing backup power to critical systems like computers, telecom equipment, and other sensitive electronics. Solar Energy Storage: Can be used in solar applications to store excess energy for later use. Electric Vehicles: Sometimes used in smaller electric vehicle or mobility scooter systems. Alarm and Security Systems: Provides backup power to alarm systems, CCTV, and other security devices. Emergency Lighting: Often used in emergency lighting setups for buildings, factories, and other premises. 4. Performance Features: Cycle Life: The Amaron Quanta 12V 12Ah battery generally offers around 300-500 charge/discharge cycles (varies based on usage, charge/discharge depth, and environmental conditions). Discharge Current: Able to provide a high discharge current (depending on load), making it suitable for short-term high-power loads. Recharge Time: Typically around 6-8 hours for a full recharge from full discharge, but this can vary depending on the charger and charging conditions. Self-Discharge Rate: Low self-discharge rate, meaning it holds charge for a long period when not in use. 5. Key Features: High Reliability: Designed for reliable performance, making it a trusted option for various backup power systems. Safety: Valve-Regulated Lead-Acid (VRLA) design, meaning it is sealed and maintenance-free under normal operating conditions. Durability: Offers robust construction for longer-lasting performance even under challenging environmental conditions. Leak-Proof Design: The VRLA design ensures that the battery is leak-resistant, which is particularly important for use in enclosed spaces. Low Maintenance: Does not require regular water refilling like traditional flooded lead-acid batteries. 6. Charging Voltage and Current: Float Voltage: Around 13.5V to 13.8V. Charge Voltage (Bulk): Typically around 14.4V to 14.7V (depending on the charger and temperature). Charge Current: Around 0.1C to 0.3C (for a 12Ah battery, this translates to a charge current of about 1.2A to 3.6A). 7. Temperature Range: Operating Temperature: Generally from -15°C to 50°C, but the optimal temperature range for performance is usually between 20°C to 25°C. Storage Temperature: For best longevity, store the battery at temperatures between 15°C to 25°C. 8. Warranty: Warranty Period: Amaron Quanta batteries typically come with a warranty period of 1-2 years, depending on the region and specific seller's terms. 9. Advantages: Cost-Effective: Amaron Quanta batteries are considered affordable yet reliable for various low to medium capacity backup systems. Wide Availability: These batteries are widely available in many regions and are popular due to their reputation for consistent performance. Maintenance-Free: VRLA technology means no need for regular maintenance, unlike flooded batteries. 10. Safety Considerations: Ventilation: While sealed, it's important to ensure that the battery is placed in a well-ventilated area to prevent the buildup of gases. Avoid Deep Discharge: Like most lead-acid batteries, it is not recommended to discharge the battery below 50% of its total capacity frequently, as this can shorten its lifespan. Proper Charging: Always use a proper charger designed for lead-acid batteries, as improper charging can lead to overcharging or undercharging, which will reduce battery life. 11. Comparison with Other Batteries: Compared to other 12V 12Ah batteries, the Amaron Quanta typically offers good cycle life, consistent performance, and a strong reputation for reliability. It is one of the more affordable options in its class, which makes it a good choice for cost-conscious consumers looking for backup power. Conclusion: The Amaron Quanta 12V 12Ah is a reliable and efficient lead-acid battery suitable for a variety of applications, from backup power systems to solar storage. It offers robust performance, minimal maintenance, and a reasonable lifespan with proper care. It's an excellent choice if you're looking for a cost-effective power solution for home or small business applications.

Send Message
product image
Battery

Amaron Short Tubular Batteries are a specific type of lead-acid battery designed primarily for use in inverter applications, particularly in regions with frequent power outages. These batteries are known for their durability, long life, and ability to handle deep discharge cycles. Below are the key details and specifications for Amaron Short Tubular Batteries: General Features: Design: Short tubular design allows for better space utilization and easier installation in various setups. Maintenance-Free: Many models are designed to be low-maintenance, requiring minimal attention during their lifespan. Deep Cycle Capability: Specifically engineered to handle deep discharges, making them ideal for inverter applications. Long Life: Known for their longevity, often lasting longer than conventional flat plate batteries. High Efficiency: Offers better charge acceptance and discharge performance, making them suitable for high-demand applications. Corrosion Resistance: Designed with materials that resist corrosion, enhancing the battery's lifespan. Specifications: While specific specifications can vary depending on the model, here are some common specifications for Amaron Short Tubular Batteries: Voltage: 12V Capacity: Typically ranges from 100 Ah to 220 Ah, depending on the model. Dimensions: Varies by model; common sizes include: 100 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) 150 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) 200 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) Weight: Generally ranges from 30 kg to 60 kg depending on capacity. Applications: Inverter Systems: Primarily used in home inverter systems for power backup. Solar Applications: Can also be used in solar power systems for energy storage. Commercial Use: Suitable for small businesses requiring reliable power backup solutions. Warranty: Amaron Short Tubular Batteries typically come with a warranty ranging from 24 to 36 months, depending on the specific model. Maintenance Tips: Water Level Check: If the battery is not maintenance-free, periodically check the electrolyte level and top up with distilled water if necessary. Terminal Cleaning: Regularly clean the battery terminals to prevent corrosion. Secure Installation: Ensure that the battery is securely mounted to prevent movement and damage. Environmental Considerations: Lead-acid batteries must be disposed of properly to prevent environmental harm. Many retailers offer recycling programs for old batteries. Conclusion: Amaron Short Tubular Batteries are a reliable choice for those needing a robust power backup solution, especially in areas with frequent power interruptions. For specific models and their detailed specifications, it is advisable to consult the manufacturer's catalog or speak with a retailer.

Send Message
product image
Battery

The Amaron Quanta 100Ah battery is designed for reliable power backup, particularly in applications like telecom, UPS systems, and industrial use. Here are the key details: Specifications Voltage: 12V Capacity: 100Ah Type: Sealed Maintenance Free (SMF) Lead-Acid Battery Technology: Advanced lead-calcium technology for enhanced performance. Key Features Maintenance-Free: No need for regular electrolyte topping, making it user-friendly. Long Life: Designed for extended service life with minimal degradation over time. High Durability: Built to withstand harsh operating conditions, including temperature fluctuations. Deep Discharge Capability: Suitable for applications that require deep cycling. Vibration Resistance: Can endure vibrations, making it ideal for industrial environments. Applications Telecommunications: Provides backup power for telecom equipment and infrastructure. UPS Systems: Used in uninterruptible power supplies for critical loads. Solar Energy: Suitable for solar applications where energy storage is necessary. Industrial Use: Powers machinery and equipment requiring reliable energy. Physical Characteristics Dimensions: Approximately 330 mm x 170 mm x 220 mm (length x width x height). Weight: Around 30-35 kg (exact weight may vary slightly). Safety Features Valve-Regulated: Prevents leakage and spillage of electrolytes. Thermal Management: Built to operate safely within specified temperature ranges. Short Circuit Protection: Designed to disconnect safely in the event of a short circuit. Warranty Typically comes with a warranty of 18 months to 2 years, depending on usage and application. Maintenance Tips Although maintenance-free, check terminals for cleanliness and tightness periodically. Ensure the battery is kept in a well-ventilated area to avoid overheating. Conclusion The Amaron Quanta 100Ah battery is a reliable solution for a variety of applications, offering excellent performance with minimal maintenance.

Send Message
product image
Luminous Ups

The Luminous LD30KH-PRO is a high-performance Inverter designed to provide reliable backup power for homes, offices, and small commercial setups. It is a part of Luminous' Pure Sine Wave Inverter series, offering high efficiency and stable power supply to sensitive equipment like computers, refrigerators, air conditioners, and other appliances. Here are the key features and specifications of the Luminous LD30KH-PRO: Key Features: Power Capacity: 30 kVA (Kilovolt-Ampere) – It is designed to support large power loads, making it suitable for medium to large residential, commercial, or industrial applications. Pure Sine Wave Output: Provides clean and stable output voltage, ensuring that sensitive equipment (like computers, air conditioners, and medical equipment) operates without issues, such as noise or voltage fluctuations. High Efficiency: The inverter operates with high efficiency, which reduces power loss and ensures that more of the battery's energy is used to power connected appliances. Advanced Microprocessor Technology: The inverter uses a microprocessor-based design to ensure high performance, protection, and reliability. It optimizes charging and discharging cycles, as well as load management. User-Friendly LCD Display: It comes with an intuitive LCD display that shows important information such as battery status, power usage, input and output voltage, and fault conditions. This helps users easily monitor and manage the system. Wide Input Voltage Range: The inverter operates with a wide input voltage range, which helps it perform well under varying input conditions. This feature helps protect connected equipment from power surges and fluctuations. Multiple Protection Mechanisms: Built-in protection features include overload protection, short-circuit protection, deep discharge protection, and battery reverse polarity protection, which ensures the safety of the connected equipment. Battery Compatibility: The Luminous LD30KH-PRO is compatible with both lead-acid and lithium-ion batteries, giving users flexibility depending on their preferences for battery technology. Smart Battery Management: The inverter comes with intelligent battery management to optimize battery performance, extending their lifespan and ensuring safe charging and discharging cycles. Compact and Reliable Design: Designed with a compact form factor and a durable build, the inverter is ideal for both indoor and outdoor installations and can be used for both backup power and off-grid applications. Applications: Residential Homes – For providing backup power for large appliances like air conditioners, refrigerators, lighting, and electronics. Small and Medium Businesses – For ensuring uninterrupted power supply to computers, servers, and other essential equipment. Commercial Use – Ideal for large offices, small industries, and workshops. Rural/Off-Grid Areas – Can be used in places with frequent power outages or no access to the grid, providing a reliable power solution. Specifications Summary: Rated Capacity: 30 kVA Output Type: Pure Sine Wave Input Voltage: 120V – 300V (depending on model) Charging Current: Adjustable (depends on load) Display: LCD with detailed status updates Battery Compatibility: Compatible with lead-acid and lithium-ion batteries

Send Message
product image
Battery Replacement In Faridabad

Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each. Types of Batteries and Their Replacement Process 1. Lead-Acid Batteries Common Types: Flooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells. Sealed Lead-Acid (SLA): Maintenance-free and does not require water addition. Absorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats. Gel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications. Replacement Process: Turn off the system: Ensure the system is powered off, and disconnect it from the grid or load. Safety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases. Disconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal. Remove old batteries: Lift and remove the batteries carefully, especially if they're heavy. Clean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water. Install new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal. Check the system: Power on the system and check the voltage and charging status. Maintenance Tips: Regularly check the electrolyte levels in flooded batteries. Clean terminals and ensure the battery box or tray is secure. 2. Lithium-Ion Batteries Common Types: Lithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan. Lithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools. Lithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications. Lithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones. Replacement Process: Turn off the system: Disconnect the power source or system. Safety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage. Disconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal. Remove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries. Install the new battery: Place the new battery in the same orientation and secure it. Reconnect terminals: Attach the positive terminal first, followed by the negative terminal. Check the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly. Maintenance Tips: Lithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range. Battery Management System (BMS) should be monitored to ensure proper functioning and safety. Conclusion: Battery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation. Lead-acid batteries need regular maintenance, especially flooded types. Lithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance. Always follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.

Send Message
product image
Vertiv Powerbank

The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency. Key Specifications Model: Liebert Powerbank 600 Capacity: 600 kVA Input Voltage: Typically supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Form Factor: Modular design for easy scalability Efficiency: High efficiency, often exceeding 95% in double conversion mode Features Modular Design: Allows for easy expansion and maintenance, enabling users to add or replace modules as needed. High Availability: Designed for redundancy and reliability, ensuring continuous power supply to critical loads. Advanced Monitoring: Equipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking. Flexible Configuration: Supports various configurations to meet specific power requirements and environmental conditions. Battery Management: Intelligent battery management features to optimize battery life and performance. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Compact Footprint: Designed to maximize power density in limited spaces, making it suitable for various installation environments. Applications Data Centers: Provides robust power protection for critical IT infrastructure. Telecommunications: Ensures uptime for communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Performance Metrics Input Frequency: Typically supports 50/60 Hz Output Power Factor: Generally rated at 0.9, allowing for efficient power delivery. Operating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius. Conclusion The Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
Battery

The Amaron 200Ah Current Tall Tubular Inverter Battery (AR200TT54) is a popular choice for home and small office power backup solutions. It is known for its long-lasting performance and is designed to support high power demands while offering reliable service for inverters. Here\'s a detailed breakdown of the features and specifications of this battery: Key Features: Battery Type: Tubular Lead Acid Battery – Known for better deep-cycle performance and durability as compared to flat-plate batteries. It is especially suited for areas with long and frequent power outages. Capacity: 200 Ah (Ampere-Hours) – This indicates the total charge the battery can hold, with 200 Ah being suitable for larger inverters or longer power backup requirements. Design: Tall Tubular Design – The tubular design enhances performance and life span as it offers better heat dissipation and reduces the chances of plate corrosion. Technology: Amaron\'s proprietary technology – Utilizes advanced battery design and manufacturing processes that provide greater resistance to overcharging, longer life, and higher efficiency. Maintenance: Low maintenance – The battery comes with an advanced grid technology and corrosion-resistant components, which minimizes the need for constant maintenance. Long Life: Longer battery life – The tubular design and advanced technology help extend the life of the battery compared to other types of lead-acid batteries, making it a reliable long-term investment. High Durability: Durable in high temperatures – It performs well in high-temperature conditions, making it suitable for regions with hot climates. Deep Discharge Recovery: Deep discharge tolerance – This battery can tolerate deep discharges and can recover from them effectively, making it more reliable when the power goes out for extended periods. Warranty: Typically comes with a 2-year warranty (may vary depending on the dealer or region), which ensures that the battery is protected against manufacturing defects. Performance Considerations: Backup Time: The backup time depends on the load connected to the inverter. A 200Ah battery typically supports moderate to heavy loads for up to 6-8 hours depending on inverter efficiency and power usage. Charging Time: Generally, a fully discharged 200Ah battery will take 8–12 hours to charge completely, depending on the charging system’s capacity. Applications: Home UPS Systems: Ideal for homes with moderate to heavy power usage. Inverters: Works well with most domestic and industrial inverters. Solar Systems: Can be used for off-grid and hybrid solar setups. Small Offices/Commercial Use: Suitable for locations that require a stable and reliable power backup. Pros: Long-lasting: The tubular design offers superior longevity compared to other types of batteries. Higher Charge Retention: Better charge retention ensures less frequent charging. Corrosion Resistance: Advanced technology ensures that the plates are protected from corrosion, which can extend the battery life. Cons: Weight: As a high-capacity lead-acid battery, it is heavy and might require more effort during installation. Space Requirements: It may require a bit more space compared to flat plate batteries due to its larger size. Conclusion: The Amaron AR200TT54 200Ah inverter battery is an excellent choice for those who need a high-capacity, durable, and low-maintenance backup solution. Whether you are using it for residential, commercial, or solar power applications, it provides long-term performance and reliability in all kinds of power outage scenarios.

Send Message

Still searching for