product image
Battery

Exide Technologies is a global leader in battery manufacturing, known for high-quality products and advanced battery technology. The company produces batteries for various applications, including automotive, marine, and industrial sectors. Product Range Exide offers a wide range of car batteries suitable for different vehicle types, including: Light Vehicles: Standard batteries for everyday cars. Commercial Vehicles: Heavy-duty batteries designed for trucks and buses. Hybrid and Electric Vehicles: Specialized batteries for modern electric and hybrid cars. Powersport Batteries: Batteries for motorcycles, ATVs, and other recreational vehicles. Battery Types Lead-Acid Batteries: Traditional batteries that are widely used in vehicles. AGM (Absorbent Glass Mat) Batteries: Maintenance-free batteries that provide better performance and longer life. Li-ion Batteries: Advanced lithium-ion batteries for electric and hybrid vehicles, offering higher energy density and efficiency. Battery Finder Tool Exide provides an online tool to help customers find the right battery for their vehicle by entering specific vehicle details or battery specifications. Quality Assurance Exide batteries are manufactured in certified plants across Europe, adhering to the highest Original Equipment Manufacturer (OEM) standards. The company supplies batteries to 75% of vehicle manufacturers, ensuring reliability and quality. Accessories and Support Exide offers a range of accessories, including chargers and testing equipment, to support battery maintenance and replacement. Workshops can access tools and resources to enhance service quality and profitability. Latest Innovations Exide continuously innovates, with recent developments including: Marine & Leisure Li-ion batteries featuring a \'sleep mode\' function for energy efficiency. Recertification of their Marine & Leisure battery range, ensuring compliance with industry standards. Conclusion Exide car batteries are designed to meet the diverse needs of modern vehicles, combining advanced technology with high-quality manufacturing. Their extensive product range, commitment to quality, and innovative solutions make them a trusted choice for consumers and automotive manufacturers alike. For more detailed information, you can visit their official website or use their battery finder tool to select the appropriate battery for your vehicle.

Send Message
product image
Amaron industrial batteries

Amaron industrial batteries are designed for heavy-duty applications and are known for their reliability, performance, and long service life. Here’s a detailed overview of their features, types, specifications, and applications: Key Features Robust Construction: Designed to withstand harsh industrial environments, these batteries are built to resist vibrations, shocks, and extreme temperatures. High Cycle Life: Amaron industrial batteries are engineered for deep cycling, offering excellent performance in frequent charge and discharge cycles. Maintenance-Free Options: Many models are sealed and maintenance-free, reducing the need for regular upkeep. Versatile Applications: Suitable for a variety of industrial uses, from backup power to specialized equipment. Efficiency: High charging efficiency allows for quicker recharge times and optimal energy utilization. Corrosion Resistance: Constructed with materials that resist corrosion, enhancing longevity and performance. Types of Amaron Industrial Batteries Amaron Quanta: Use: Ideal for industrial applications, including UPS systems, telecommunications, and other critical power needs. Features: Available in both 12V and 2V configurations, designed for high capacity and reliability. Amaron SMF (Sealed Maintenance-Free): Use: Suitable for various industrial applications where maintenance is challenging. Features: Provides reliable power with low self-discharge rates, ensuring long shelf life. Amaron AGM Batteries: Use: Ideal for high-performance applications, including industrial machinery and equipment. Features: Offers excellent power delivery and deep cycle capabilities. Specifications Voltage: Available in both 12V and 2V configurations. Capacity: Ranges from 100Ah to over 300Ah, depending on the specific model. Sizes: Various sizes are available to fit different industrial setups and requirements. Applications Uninterruptible Power Supply (UPS): Used in UPS systems for critical applications, ensuring power continuity. Telecommunications: Powers telecom equipment and towers, providing reliable backup. Material Handling Equipment: Suitable for forklifts, pallet jacks, and other industrial vehicles. Renewable Energy Systems: Can be used in conjunction with solar or wind energy systems for energy storage. Mining and Construction: Ideal for equipment used in harsh conditions and demanding environments. Conclusion Amaron industrial batteries are designed for performance and reliability in demanding applications, making them a preferred choice for various industries. For specific models, detailed specifications, or further information, it’s best to check the Amaron website or consult with local distributors. If you have specific questions or need more details about a particular model, feel free to ask!

Send Message
product image
UPS Rental & UPS Repairing Service

Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems: Repair Process Initial Assessment Gather Information: Document symptoms such as alarms, performance issues, or failure to start. Visual Inspection: Look for signs of physical damage, burnt components, or loose connections. Diagnosis Self-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes. Multimeter Testing: Use a multimeter to check voltage levels, current, and resistance. Battery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity. Inspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault. Common Issues Battery Failure: The most common issue; batteries may need replacement due to age or improper charging. Capacitor Issues: Capacitors can degrade over time, leading to performance problems. Overheating: Caused by dust accumulation, blocked ventilation, or fan failure. Control Board Failures: Issues with the control board can affect functionality. Input/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues. Repair and Replacement Battery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity. Component Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics. Soldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board. Firmware Updates: If applicable, update the firmware for optimal performance. Testing After Repair Functional Testing: Run the UPS to ensure it operates correctly. Load Testing: Test under load conditions to verify performance and capacity. Battery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected. Final Inspection Safety Checks: Verify that all repairs meet safety standards. Documentation: Record all repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct periodic self-tests and inspections to identify potential issues early. Battery Maintenance: Keep battery terminals clean and ensure connections are tight. Cooling: Ensure proper ventilation around the UPS to prevent overheating. Environment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures. When to Seek Professional Help If issues are complex or beyond basic troubleshooting, consult a professional service. Use authorized Vertiv service centers for repairs to ensure quality and warranty compliance. Conclusion Repairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.

Send Message
product image
UPS Repair

Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations: UPS Repair Process Initial Assessment Identify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms. Visual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections. Diagnosis Self-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues. Multimeter Testing: Measure voltage, current, and resistance to identify electrical issues. Battery Testing: Check the health of the batteries using a battery tester or multimeter. Check Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning. Common Issues Battery Failure: Batteries may need replacement due to age or over-discharge. Capacitor Issues: Capacitors can fail due to heat or age, leading to performance issues. Cooling Problems: Blocked fans or insufficient ventilation can cause overheating. Control Board Malfunctions: Issues with the control board can affect the UPS's operation. Input/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry. Repair and Replacement Battery Replacement: Remove and replace old batteries with new ones of the same specifications. Component Replacement: Replace faulty capacitors, fuses, or other components as diagnosed. Resoldering Connections: Fix any broken or loose solder joints on the circuit board. Software/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance. Testing After Repair Functional Testing: After repairs, perform a complete functional test of the UPS. Load Testing: Test the UPS under load to ensure it can handle the required capacity. Battery Cycle Testing: Run the UPS on battery power to check for proper operation. Final Inspection Safety Check: Ensure all repairs meet safety standards. Documentation: Document the repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct regular self-tests and inspections to catch issues early. Battery Maintenance: Check battery connections and terminals periodically; keep them clean and tight. Environment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan. Firmware Updates: Keep the UPS firmware updated for improved performance and security. Professional Repair Services When to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional. Authorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs. Conclusion Repairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.

Send Message
product image
UPS ( Uninterrupted Power Supplies)

The Vertiv Liebert Hipulse-U 30kVA UPS is a high-performance uninterruptible power supply designed for critical applications. Here\\'s an overview of the Vertiv Liebert Hipulse-U 30kVA UPS and its specifications: ** Key Features:** Online double conversion topology for high power quality and reliability 30kVA/30kW power rating with high power factor (0.9-1.0) 3-phase input and 3-phase output configuration Scalable runtime options with matching external battery cabinets ENERGY STAR 2.0 certified for energy efficiency Intuitive gravity sensing full-color LCD display Remote management capabilities with optional Vertiv RDU101 network communications card 3-year comprehensive warranty including battery with options for 2-year extension Technical Specifications: Load Capacity: VA: 30000 VA Watt: 30000 W Output Voltage: 208V AC (3-phase) 400V AC (3-phase) Waveform Type: Pure Sine Wave User Selectable Output: 208/120VAC 400/230VAC Utility (AC) Mode Overload: 105% to 125% for 5 minutes 125% to 150% for 60 seconds Bypass Switch: Automatic & Manual Internal Maintenance Plug/Connector Type: Terminal Block Product Overview: The Vertiv Liebert Hipulse-U 30kVA UPS is designed to protect critical equipment against outages and every type of power disturbance. This 30kVA online double conversion UPS offers continuous power conditioning in centralized and edge locations. With high power factor (0.9-1.0), it allows more connected loads saving space and costs. This tower/rack mount UPS has a built-in Vertiv RDU101 communications card for remote monitoring to help you make more informed decisions and faster event resolution. With the free Vertiv Power Insight software, you can consolidate your view of up to 100 distributed UPS units providing simple notification of status and events in a single pane of glass.

Send Message
product image
Exide Batteries In Ajronda Faridabad

Exide batteries are known for their reliability and performance in various applications, including automotive, industrial, and renewable energy systems. Here\\'s an overview of Exide batteries, along with details about their racks and mounting options: Types of Exide Batteries Lead-Acid Batteries: Flooded Lead-Acid: Standard type, requires maintenance. Absorbent Glass Mat (AGM): Sealed, maintenance-free, and offers better vibration resistance. Gel Batteries: Sealed, good for deep-cycle applications. Lithium Batteries: Lightweight and longer lifespan compared to lead-acid. Suitable for advanced applications like electric vehicles and renewable energy systems. Features Durability: Designed to withstand harsh conditions. Deep-Cycle Capability: Ideal for applications requiring repeated discharge and recharge. Fast Charging: Some models support quick recharge times. Rack Systems Battery Racks: Typically made from steel or aluminum, designed to hold multiple batteries securely. Modular Designs: Allow for scalability based on the number of batteries needed. Ventilation: Many racks include features to promote airflow, which helps in cooling and battery performance. Installation and Maintenance Installation: Requires proper spacing and secure connections to ensure safety and performance. Maintenance: Regular checks on electrolyte levels (for flooded types) and connections are recommended for optimal performance. Applications Automotive: Starting, lighting, and ignition (SLI). Renewable Energy: Solar and wind energy storage systems. Industrial: Forklifts and other heavy equipment. Safety Considerations Ensure proper ventilation to prevent gas buildup. Follow manufacturer guidelines for installation and maintenance. Use appropriate personal protective equipment (PPE) during handling. Conclusion Exide batteries are versatile and widely used, supported by robust rack systems for various applications. Their features cater to both standard and specialized needs, ensuring reliability and performance. Always refer to specific product documentation for detailed specifications and installation instructions.

Send Message
product image
Batteries Repairing & AMC Services in Delhi

Overview: We provide specialized repairing and Annual Maintenance Contract (AMC) services for batteries ranging from 7Ah to 280Ah. Our services are designed to extend battery life, ensure optimal performance, and reduce unexpected costs. Services Offered: Battery Repair Services: Diagnostics and Testing: Comprehensive testing to identify issues such as capacity loss, internal resistance, and short circuits. Reconditioning: Techniques to restore battery capacity, including desulfation and electrolyte replenishment. Cell Replacement: Replacement of faulty cells to improve overall battery health. Sealing and Maintenance: Sealing and maintenance of battery terminals to prevent corrosion. Annual Maintenance Contracts (AMC): Regular Inspections: Scheduled inspections to monitor battery health and performance. Preventive Maintenance: Cleaning and servicing to prevent issues before they arise. 24/7 Support: Round-the-clock assistance for any battery-related emergencies. Customized Plans: AMC plans tailored to individual requirements and usage patterns. Battery Capacity Focus: Range: 7Ah to 280Ah Small Batteries (7Ah - 40Ah): Ideal for UPS systems, alarms, and backup power solutions. Medium Batteries (40Ah - 120Ah): Used in telecommunications, solar applications, and larger UPS systems. Large Batteries (120Ah - 280Ah): Suitable for industrial applications, large UPS systems, and energy storage solutions. Benefits of Our Services: Extended Battery Life: Regular maintenance and timely repairs can significantly increase battery lifespan. Cost-Effective Solutions: AMC services help prevent unexpected expenses due to battery failures. Expert Technicians: Skilled professionals with experience in handling various battery types and brands. Quick Turnaround: Efficient service delivery to minimize downtime. Safety Assurance: Adherence to safety standards during repairs and maintenance. Contact Information: For inquiries or to schedule a service, please contact us: Phone: 8744823336 Email: info@universalpower.co.in Address: Plot No.-70, Udyog Vihar-VI, Sector-37 Gurugram, Haryana, India -122001

Send Message

Still searching for