Bhiwadi
+918076792323

'up to 10 years'

Items tagged with 'up to 10 years'

product image
9PX Lithium-ion UPS

The Eaton 9PX Lithium-ion UPS is designed for mission-critical applications, offering an extended battery life of 8 to 10 years. It features power ratings from 1 to 6 kVA, advanced ABM technology for battery longevity, and flexible configurations for both rack and tower setups. Key Specifications: Power Ratings: 1 kVA to 6 kVA Battery Type: Lithium-ion with 8-10 years life expectancy Form Factor: Rackmount and tower options Connectivity: Multiple external battery module options Warranty: 5 years on electronics and internal batteries Key Features: ABM Technology: Extends battery service life by up to 50% Remote Management: Capable of remote monitoring and management Compact Design: Space-saving design suitable for various environments Output: Pure sine wave output for sensitive equipment Performance and Reliability: Run Time: Varies based on load; designed for high availability Noise Level: Operates quietly, suitable for office environments

Send Message
product image
UPS

Vertiv Liebert PSA - 1000VA Mini Tower UPS PSA1000MT3-230U Specifications and Details The Vertiv Liebert PSA PSA1000MT3-230U is a line-interactive uninterruptible power supply (UPS) designed to provide reliable power protection for small office computers and electronic equipment. Below are the detailed specifications and features of this UPS model. Key Specifications Model: Vertiv Liebert PSA PSA1000MT3-230U Capacity: VA: 1000 VA Watts: 600 Watts Form Factor: Mini Tower Phase: Single Phase (1:1) Battery Type: Lead Acid Run Time: Typical: 5 minutes (varies with load) Warranty: 2 years Physical Dimensions Height: 234 mm Width: 147 mm Depth: 360 mm Weight: 9.5 kg Features User -Friendly LED Display: Provides easy operation and monitoring of UPS status. Socket Configuration: Multiple battery-backed and surge-protected sockets to accommodate different types of loads. Includes a mix of battery-backed and surge-only sockets. USB Communication: Comes with USB communications/shutdown software and cable for plug-and-play use. User -Replaceable Batteries: Designed for easy battery replacement to maximize the initial investment. Data Line Protection: Protects data lines to ensure the safety of connected devices. Environmental Compliance: Fully RoHS compliant, ensuring it meets environmental standards. Additional Information Input Voltage: Typically operates at 230 VAC. Output Waveform: Simulated sine wave. Runtime Performance: Provides 5 or more minutes of battery backup depending on the load level. Conclusion The Vertiv Liebert PSA PSA1000MT3-230U is an efficient and cost-effective solution for power protection in small office environments. Its combination of features, including user-friendly interfaces, multiple socket options, and easy maintenance, makes it a reliable choice for safeguarding electronic equipment against power interruptions.

Send Message
product image
UPS

The VERTIV Liebert ITON CX 1000VA UPS is a line-interactive uninterruptible power supply designed for home and small office use. Below are the details regarding its unboxing and quick testing. Unboxing Details Packaging: The UPS comes securely packaged to prevent damage during transit. Ensure to check for any visible signs of damage upon receipt. Included Items: VERTIV Liebert ITON CX 1000VA UPS unit User manual and installation guide Power cord with UK outlet Warranty card Initial Inspection: Check the UPS for any physical damage. Verify that all components are included as per the manual. Quick Test Procedure Setup: Place the UPS in a well-ventilated area. Connect the power cord to the UPS and plug it into a wall outlet. Power On: Press the power button to turn on the UPS. Observe the LED indicators: Green Light: Indicates AC mode (normal operation). Red Light: Indicates a fault condition. Battery Mode Test: To test the battery mode, disconnect the UPS from the wall outlet. Ensure that the UPS switches to battery mode automatically. Check the runtime by connecting a load (e.g., a computer) and monitor how long the UPS can sustain power. Load Testing: Connect a load that draws approximately 120W (e.g., a standard desktop computer). Monitor the backup time, which should be around 30 minutes under this load. Recharge Time: After the test, reconnect the UPS to the wall outlet. Note that the typical recharge time is 6-8 hours to reach 90% capacity. Key Specifications Power Capacity: 1000 VA / 600 Watts Input Voltage: 220/230 VAC Output Waveform: Simulated Sine Wave Transfer Time: 2-6 ms Battery Type: 12 V / 7 Ah x 2 Typical Backup Time: 30 minutes at 120W load Dimensions: 369 x 141 x 160 mm Weight: 10 kg Conclusion The VERTIV Liebert ITON CX 1000VA UPS is a reliable solution for power protection in small setups. The unboxing and quick test confirm its functionality and performance, making it a suitable choice for users needing uninterrupted power supply for their electronic devices. Always refer to the user manual for detailed instructions and safety precautions.

Send Message
product image
UPS Repair

When it comes to Vertiv 10kVA UPS repair and testing, it involves several key processes to ensure that the UPS functions correctly and reliably. Below are the details regarding Vertiv 10kVA UPS repair and testing: Vertiv 10kVA UPS Repair Common Issues: Battery Failure: Batteries may degrade over time and need replacement. Inverter Problems: The inverter may fail to convert DC to AC power. Overheating: Excessive heat can damage internal components. Faulty Charging Circuit: Issues with the charging system can prevent batteries from charging properly. Software Failures: Problems with firmware can affect UPS functionality. Repair Process: Diagnosis: Use diagnostic tools to identify issues. Check for error codes or alerts on the UPS display. Component Testing: Test batteries for capacity and voltage. Inspect the inverter and charging circuits for faults. Replacement of Parts: Replace faulty batteries with new ones. Repair or replace damaged circuit boards, inverters, or other components. Calibration: Calibrate the UPS settings to ensure optimal performance. Final Testing: Conduct a load test to verify that the UPS can handle its rated capacity. Vertiv 10kVA UPS Testing Testing Procedures: Visual Inspection: Check for physical damage, loose connections, or corrosion. Battery Testing: Measure the voltage and capacity of the batteries. Conduct a discharge test to ensure batteries can hold a charge. Load Testing: Connect a load to the UPS and monitor its performance. Ensure that the UPS can supply power for the specified duration under load. Transfer Time Testing: Measure the time it takes for the UPS to switch from mains to battery power and back. Efficiency Testing: Assess the efficiency of the UPS under various loads to ensure it meets manufacturer specifications. Maintenance Recommendations Regular Maintenance: Schedule regular checks (at least annually) to ensure all components are functioning correctly. Battery Replacement: Replace batteries every 3-5 years, depending on usage and manufacturer recommendations. Firmware Updates: Keep the UPS firmware updated to benefit from the latest features and fixes. Conclusion Proper repair and testing of Vertiv 10kVA UPS systems are crucial for ensuring reliable power backup. Regular maintenance can prevent unexpected failures and extend the lifespan of the unit. If you require further details on specific models or repair services, feel free to ask!

Send Message
product image
UPS & BATTERIES MAINTENANCE IN SECTOR 55 NOIDA

Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring reliable performance and extending their lifespan. Here’s a comprehensive guide on UPS battery maintenance: 1. Regular Inspection Visual Checks: Inspect batteries for physical damage, leaks, or corrosion. Connections: Ensure that terminals and connections are tight and free from corrosion. 2. Battery Testing Load Testing: Conduct regular load tests to ensure batteries can handle the expected load. Voltage Checks: Measure the voltage of each battery regularly to identify weak cells. 3. Cleaning Dust and Debris: Keep the battery area clean and free from dust. Use a soft brush or cloth. Corrosion Removal: Clean any corrosion from terminals with a solution of baking soda and water. 4. Temperature Monitoring Operating Temperature: Keep batteries within the manufacturer’s recommended temperature range (typically 20-25°C). Ventilation: Ensure proper airflow around the batteries to prevent overheating. 5. Charging Practices Regular Charging: Ensure batteries are charged regularly, even if the UPS is not in use. Avoid Deep Discharge: Do not allow batteries to discharge below the recommended level. 6. Battery Replacement Age and Cycle Life: Be aware of the expected lifespan (usually 3-5 years for lead-acid batteries) and replace batteries as needed. Use OEM Batteries: Always replace with original equipment manufacturer (OEM) batteries to ensure compatibility. 7. Documentation and Logs Maintenance Log: Keep records of inspections, tests, and replacements. Battery Specifications: Document battery type, installation date, and capacity for reference. 8. Environmental Considerations Disposal: Follow local regulations for disposing of old batteries. Storage: Store spare batteries in a cool, dry place. 9. Professional Servicing Annual Maintenance: Consider scheduling annual inspections by a professional to assess battery health. 10. Safety Precautions Personal Protective Equipment (PPE): Always wear gloves and safety goggles when handling batteries. Emergency Procedures: Be familiar with emergency procedures in case of battery leaks or failures. By following these maintenance tips, you can ensure your UPS batteries operate efficiently and last longer. Regular upkeep is key to preventing unexpected failures and ensuring reliable power during outages.

Send Message
product image
Vertiv 10kVA UPS

A Vertiv 10kVA UPS (Uninterruptible Power Supply) is a reliable power backup system designed to provide uninterrupted power to critical equipment, such as servers, networking devices, and other sensitive electronic systems. The 10kVA rating indicates that the UPS can handle loads of up to 10,000 volt-amperes, which is typically suitable for medium-sized office setups or small data centers. Vertiv (formerly Emerson Network Power) is known for offering high-quality, efficient, and reliable UPS solutions that help prevent downtime and protect equipment from power surges, outages, and other electrical disturbances. Here are some key features you might find in a Vertiv 10kVA UPS: Power Capacity: 10 kVA (or approximately 8 kW for resistive loads), which can support multiple servers or network equipment. Efficiency: Many Vertiv UPS systems are designed with energy efficiency in mind, minimizing energy loss and operating costs. Battery Type: Typically uses either VRLA (Valve Regulated Lead Acid) or Lithium-Ion batteries, providing long-lasting backup time during power interruptions. Form Factor: These systems may come in both rack-mounted or tower configurations, depending on space requirements. Scalability: Some Vertiv UPS units allow for modular expansion, meaning you can add additional units or battery packs to increase power capacity. Monitoring and Control: Advanced models often come with digital monitoring features, allowing remote monitoring of UPS status, battery health, and power consumption via web interfaces or software. Surge Protection and Isolation: Protects your sensitive equipment from power surges, voltage spikes, and electrical noise. Maintenance Bypass: Many UPS models, including 10kVA versions, have maintenance bypass switches that allow you to service the unit without interrupting power to connected devices. Vertiv offers various UPS models in this range, so if you’re looking to purchase, it's important to check specifications for exact features, runtime, and compatibility with your equipment.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
Vertiv 10 Kva Ups

The Vertiv Liebert GXT MT LX (3 X 3) 10KVA UPS is a compact and reliable uninterruptible power supply designed for critical applications. It features best-in-class efficiency, robust protection, and simplified installation, making it suitable for commercial use. Key Specifications Power Rating: 10 KVA Phase: 3-phase, 4-wire Input Voltage: 400VAC Output Type: Online double conversion Warranty: 1 year Features High Efficiency: Offers excellent energy efficiency, reducing operational costs. Compact Design: Space-saving design ideal for various environments. Remote Monitoring: Capable of remote management for enhanced operational oversight. Applications Ideal for data centers, telecommunications, and other critical systems requiring uninterrupted power. For more detailed specifications, refer to the official Vertiv documentation. ### Additional Features True Online Double-Conversion: Provides continuous power supply and protects against power disturbances. DSP Processor: Utilizes the latest Digital Signal Processing technology for enhanced performance. Output Power Factor: Rated at 0.9, ensuring efficient power delivery. Active Input Power Factor Correction: Maintains efficiency across all phases. Frequency Converter Mode: Supports both 50 Hz and 60 Hz operations. ECO Mode Operation: Energy-saving mode that optimizes efficiency during low-load conditions. Emergency Power-Off Function (EPO): Allows for immediate shutdown in emergencies. Generator Compatibility: Designed to work seamlessly with generator systems. Multiple Communication Ports: Includes SNMP, USB, and RS-232 for versatile monitoring and management options. 3-Stage Extendable Charging Design: Optimizes battery performance and extends battery life. Adjustable Battery Numbers: Configurable for long-run models based on specific needs. Operational Conditions Operating Temperature: Functions effectively in a temperature range of 0 °C to 40 °C. Integrated Maintenance Bypass Breaker: Facilitates maintenance without interrupting power supply. Scalability: Can be expanded up to 40 kVA for growing power needs. Caster Wheels: Equipped for easy repositioning within facilities. Conclusion The Vertiv Liebert GXT MT LX (3 X 3) 10KVA UPS is engineered for high performance and reliability, making it an excellent choice for businesses that require uninterrupted power for their critical infrastructure. Its advanced features, compact design, and efficient operation ensure that essential systems remain operational during power outages. For further information, consult the official Vertiv website or authorized distributors.

Send Message
product image
Eaton 9395P UPS

The Eaton 9395P UPS is a high-performance uninterruptible power supply designed for critical applications. It features a three-phase online design with power ratings ranging from 250 to 1200 kVA, utilizing advanced technology for high efficiency and scalability. Key Specifications Power Ratings: 250-1200 kVA Input Voltage: Typically 480V, with options for 400V or 600V Efficiency: High double conversion efficiency with reduced energy losses Battery Types: Supports VRLA, AGM, and wet cell batteries Overload Capacity: 110% for 10 minutes, 125% for 2 minutes, 150% for 15 seconds Display: 7” or 10” touchscreen for monitoring and control Features Modular Design: Allows for easy scalability and maintenance. Advanced Monitoring: Provides real-time data and alerts for optimal performance. Compact Footprint: Designed to maximize power density in limited spaces. Applications Ideal for data centers, telecommunications, and industrial environments where reliable power is critical. For more detailed specifications, you can refer to the official Eaton documentation. ### Additional Features Energy Saver System (ESS): Achieves up to 99% efficiency, significantly reducing operational costs. Three-Level Converter Design: Reduces stress on components, extending their lifespan and reliability. Heat Reduction: Produces 33% less heat, leading to lower HVAC costs. Increased Power Density: Offers up to 20% more power in the same footprint compared to previous models. Redundancy: Modular design ensures inherent redundancy, preventing dropped loads. Battery Information Battery System: External battery systems are used, with options for lead-acid or lithium batteries. Batteries Included: Typically, batteries are not included and must be purchased separately. Lead Time Availability: Estimated lead time for delivery is 20+ weeks, depending on configuration and order specifics. Target Markets Enterprise Data Centers: Provides robust power protection for critical IT infrastructure. Colocation Facilities: Supports multiple clients with varying power needs. Server Farms and Telecommunications: Ensures uptime for essential services and applications. Healthcare and Financial Systems: Protects sensitive equipment and data from power interruptions. Conclusion The Eaton 9395P UPS is engineered for high efficiency and reliability, making it an excellent choice for organizations that require uninterrupted power supply. Its modular design, advanced features, and scalability cater to a wide range of applications, ensuring that critical systems remain operational during power disturbances. For further details, consult the official Eaton website or authorized distributors.

Send Message

Still searching for
up to 10 years?