Bhiwadi
+918076792323

'variable speed fans'

Items tagged with 'variable speed fans'

product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
Vertiv 6 Kva Ups

The Vertiv Liebert GXT5-6000RT120 is a popular 6 kVA online uninterruptible power supply (UPS) designed for critical applications in data centers and IT environments. Below are the key specifications and features of the Vertiv 6 kVA UPS: Key Features Form Factor: Rack-mountable (typically 3U) or tower configuration, depending on the model. Power Rating: Capacity: 6 kVA (6000 VA) / 5.4 kW output. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 120 VAC (or 220/230/240 VAC depending on configuration). Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with a hardwired connection or NEMA L6-30P plug. Output Specifications: Output Voltage: Configurable 120/208/230/240 VAC. Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple NEMA outlets or terminal block connections for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries providing backup power during outages. Battery Runtime: Varies based on load; typically offers several minutes to hours of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often exceeding 95% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB, RS-232, and optional SNMP card for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 5.2 inches (3U) in height, with width and depth depending on the specific model. Weight: Typically around 100 lbs (45 kg), depending on the battery configuration. Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT5-6000RT120 is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
Vertiv 1 kva Ups

The Vertiv Liebert GXT RT+ 1 kVA is a highly regarded rack-mountable uninterruptible power supply (UPS) designed for critical applications, including data centers and IT environments. Below are the key details and specifications for the Liebert GXT RT+ 1 kVA model: Key Features Form Factor: Rack-mountable design, typically in a 2U form factor, allowing for easy integration into standard server racks. Power Rating: Capacity: 1 kVA (1000 VA) / 800 W output. Topology: On-Line Double-Conversion: Provides continuous power and zero transfer time to battery during power disturbances, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 100-240 VAC, auto-sensing. Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with IEC C14 inlet. Output Specifications: Output Voltage: 220/230/240 VAC (configurable). Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple IEC outlets for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries that provide backup power during outages. Battery Runtime: Varies based on load; typically provides several minutes of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often above 90% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 ports for management and monitoring. SNMP card options may be available for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 3.5 inches (2U) in height, with width and depth depending on the specific model. Weight: Varies based on battery configuration but generally around 20-30 lbs (9-14 kg). Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards, such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and small servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT RT+ 1 kVA UPS is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
UPS Repair

Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations: UPS Repair Process Initial Assessment Identify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms. Visual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections. Diagnosis Self-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues. Multimeter Testing: Measure voltage, current, and resistance to identify electrical issues. Battery Testing: Check the health of the batteries using a battery tester or multimeter. Check Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning. Common Issues Battery Failure: Batteries may need replacement due to age or over-discharge. Capacitor Issues: Capacitors can fail due to heat or age, leading to performance issues. Cooling Problems: Blocked fans or insufficient ventilation can cause overheating. Control Board Malfunctions: Issues with the control board can affect the UPS's operation. Input/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry. Repair and Replacement Battery Replacement: Remove and replace old batteries with new ones of the same specifications. Component Replacement: Replace faulty capacitors, fuses, or other components as diagnosed. Resoldering Connections: Fix any broken or loose solder joints on the circuit board. Software/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance. Testing After Repair Functional Testing: After repairs, perform a complete functional test of the UPS. Load Testing: Test the UPS under load to ensure it can handle the required capacity. Battery Cycle Testing: Run the UPS on battery power to check for proper operation. Final Inspection Safety Check: Ensure all repairs meet safety standards. Documentation: Document the repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct regular self-tests and inspections to catch issues early. Battery Maintenance: Check battery connections and terminals periodically; keep them clean and tight. Environment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan. Firmware Updates: Keep the UPS firmware updated for improved performance and security. Professional Repair Services When to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional. Authorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs. Conclusion Repairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.

Send Message
product image
Apc Ups Repairing And Maintenance In Aurangabad Sonipat

Repairing and testing an APC UPS (Uninterruptible Power Supply) involves several steps to diagnose issues and ensure the unit functions properly. Here’s a detailed guide on how to approach this: Common Issues with APC UPS Battery Failure: Most common issue; symptoms include frequent beeping and inability to hold a charge. Overload: The UPS may beep continuously if connected devices exceed its capacity. Faulty Output: No power output despite being plugged in. Firmware Issues: May require updates or resets. Tools Needed Multimeter Screwdriver set Replacement batteries (if needed) Laptop or PC for firmware updates Diagnostic software (if applicable) Testing Procedure Visual Inspection: Check for physical damage, burnt components, or loose connections. Inspect the battery for any signs of swelling or leakage. Battery Testing: Disconnect the UPS from the wall outlet. Use a multimeter to measure the battery voltage. Compare it to the rated voltage (e.g., 12V for most lead-acid batteries). If the voltage is significantly lower, consider replacing the battery. Load Testing: Connect a load tester to the UPS and apply a known load (within the UPS capacity). Monitor the output voltage and see if it remains stable under load. Output Testing: Plug the UPS into the wall and turn it on. Measure the output voltage with a multimeter to ensure it’s delivering the correct voltage (typically around 120V or 230V depending on your region). Check if the UPS switches to battery mode when you disconnect it from the wall. Overload Testing: Gradually increase the load on the UPS until it beeps or shuts down. Verify that it returns to normal operation once the overload is removed. Repair Procedures Battery Replacement: Follow the manufacturer’s guidelines for replacing batteries. Dispose of old batteries responsibly. Firmware Updates: Connect the UPS to a computer. Use APC’s software (like PowerChute) to check for and install firmware updates. Component Repair: If internal components (like capacitors or fans) are damaged, soldering skills may be required for repairs or replacements. Reassembly: Carefully reassemble the UPS, ensuring all screws are tightened and no wires are pinched. Final Testing After repairs, conduct a full load test to ensure the UPS operates correctly under stress. Monitor for any unusual noises or overheating during operation. Safety Precautions Always ensure the UPS is unplugged before performing internal inspections or repairs. Handle batteries with care, as they can be hazardous. Conclusion Regular testing and maintenance of your APC UPS can extend its lifespan and ensure reliable performance. If issues persist after self-repair attempts, consider consulting a professional technician or contacting APC support for assistance.

Send Message
product image
AMC FOR ALL TYPES UPS & BATTERIES , INVERTER

Looking for Inverter, UPS, Battery AMC Universal Power System comprehensive UPS AMC and battery service solutions which are designed to improve costs, uptime, reliability, power quality and safety. Our Service Include: UPS Installation and Commissioning, Battery Replacement, Battery Testing and Maintenance, UPS Maintenance and Service Contracts, Project Management, Warranty Upgrade. In India and network of highly experienced contractors we can support clients in Gurgaon, Delhi, Noida , Bawal , Bhiwadi , Manesar , Sonipat , Faridabad and all around India. This comprehensive Annual Maintenance Contract for Home UPS and Corporates provides peace of mind to the customer as the service contract covers regular PMs (Preventive Maintenance) and unlimited breakdown calls during the contract period. Any replacement of spares is free of cost during the contract period and excludes batteries. AMC for Home UPS With a multitude of convenience products in today’s modern homes, Annual Maintenance Contract (AMC) is critical not only for the product but also for customers who have invested on the product. There are a host of benefits when you opt for Annual Maintenance Contract: No need to remember dates. No need to call us. We store your product details in our database. Our team of professionals visit once every 6 months automatically to check & maintain the health of your gadget. (Both Home UPS & Battery provided you have opted for an AMC for both) Even after expiry of warranty for your product, you can opt for Annual Maintenance Contract. Scope of Home UPS AMC Under Annual Maintenance Contract Program, the Home UPS & Batteries are included provided you opt for separate AMC’s for both. PCB’s, IGBT/SCR, Switches, Fans, Capacitors & LCD display will be replaced free of cost if there is any failure Chassis & wheels are not covered and shall be charged extra at actual. Pls write your Home UPS AMC requirements to info@universalpower.co.in we have different packages for all Range of batteries and UPS Online/Offline/Interactive UPS Maintenance Contracts for Corporates Here at Critical Power Supplies, we offer a comprehensive maintenance plan for our customers, including customisable options for your site. As leading brand service engineers, we have earned an enviable reputation for our UPS service, and boast premier power protection plans. For access to the very best in the industry, take out one of our UPS maintenance plans today and ensure that your business stays safe. As UPS systems support critical applications we believe that through planned maintenance and effective battery testing we can ensure the reliability of your backup system. We strive to offer a professional, reliable and trusted service so our customers continue to benefit from our support for the life of their system.

Send Message
product image
VERTIV 10 kVA UPS IN SONIPAT

The Vertiv 10 kVA UPS (Uninterruptible Power Supply) is designed to provide reliable power protection for critical applications. Here are some key details and features typically associated with this model: Key Features: Capacity: 10 kVA (kilovolt-amperes), suitable for medium-sized data centers and IT equipment. Topologies: Double-Conversion: Offers high-level protection against power disturbances. Line-Interactive: Provides good efficiency with moderate protection. Input/Output: Input Voltage: Typically accepts a wide range (e.g., 200-240V). Output Voltage: Usually provides a pure sine wave output at 230V. Battery: Type: Sealed lead-acid or lithium-ion options. Runtime: Varies based on load; can be extended with external battery packs. Efficiency: High efficiency ratings (up to 95% or more) in online mode to reduce energy costs. Cooling: Built-in cooling fans, sometimes with temperature monitoring. Communication: USB, SNMP, or RS-232 ports for remote monitoring and management. LCD display for status updates and alerts. Form Factor: Typically available in rack-mounted or tower configurations. Safety Certifications: Compliance with relevant safety and performance standards (e.g., CE, UL). Management Software: Often bundled with software for monitoring and managing the UPS and connected devices. Applications: Data centers Telecommunications Industrial equipment Medical facilities Maintenance: Regular battery checks and replacements. Firmware updates for management software. Considerations: Determine your total load to ensure the 10 kVA capacity is adequate. Assess the physical space for installation and cooling needs. Evaluate redundancy options if necessary for mission-critical applications.

Send Message
product image
Vertiv 30 KVA Online UPS

The Vertiv 30 KVA Online UPS is designed for high availability and reliability in critical power applications. Here are the key details: Specifications Power Rating: 30 KVA (27 kW) capacity. Input Voltage: Typically 380-480 V AC (three-phase). Output Voltage: Configurable, commonly 220/230/240 V AC (three-phase). Frequency: 50/60 Hz. Topology: Online Double-Conversion for continuous power conditioning. Output Waveform: Pure sine wave. Battery Type: Lead-acid or lithium-ion options available. Battery Runtime: Varies by load; external battery packs can extend runtime. Charging Time: Full recharge time is typically 4-8 hours. Cooling Method: Air-cooled with internal fans. Dimensions: Generally rack-mountable or floor-standing, with dimensions varying by model. Weight: Usually ranges from 150 to 300 kg, depending on the configuration. Features LCD Display: Provides real-time monitoring of system status, battery levels, and load. Multiple Outlets: Various outlet types for flexibility in connectivity. Smart Battery Management: Enhances battery life and performance. Surge Protection: Protects against voltage spikes and surges. Remote Monitoring: Options for SNMP, USB, or serial communication for remote management. Maintenance Bypass: Allows for safe maintenance without power interruptions. Modularity: Options for scalable solutions and additional battery units. Applications Data Centers Telecommunications Industrial Applications IT Infrastructure Medical Equipment Maintenance Regular maintenance is crucial for performance, including: Periodic battery checks and replacements. Cleaning of vents and fans. Load testing to ensure reliability.

Send Message
product image
Emerson 5 KVA Online UPS

The Emerson 5 KVA Online UPS is designed to provide reliable power backup and protection for critical equipment. Here are some key details you might find helpful: Specifications Power Rating: 5 KVA (4500 watts) Input Voltage: Typically around 220-240 V AC Output Voltage: 220-240 V AC, often configurable Frequency: 50/60 Hz Topologies: Online Double-Conversion, providing isolation and voltage regulation. Output Waveform: Pure sine wave. Battery Type: Usually lead-acid or lithium-ion, depending on the model. Battery Runtime: Varies based on load; typically supports extended runtime with external battery packs. Charging Time: Full recharge time is usually 4-8 hours. Cooling Method: Typically air-cooled with internal fans. Dimensions: Varies by model but generally rack-mountable or tower form factors. Weight: Generally ranges from 30 to 50 kg, depending on the design. Features LCD Display: Shows real-time status, battery health, and load levels. Multiple Outlets: Usually equipped with a combination of IEC and NEMA outlets. Smart Battery Management: Extends battery life and optimizes performance. Surge Protection: Protects connected devices from power spikes. Remote Monitoring: Some models offer SNMP or USB connectivity for remote management. Maintenance Bypass: Allows maintenance without shutting down the connected equipment. Modularity: Options for expansion and additional battery packs. Applications IT Equipment Telecommunications Medical Devices Industrial Automation Data Centers Maintenance Regular maintenance is essential to ensure optimal performance, including: Checking battery health. Cleaning dust from vents and fans. Testing the UPS under load conditions.

Send Message

Still searching for
variable speed fans?