Delta 2Kva Ups
A Delta 2kVA UPS (Uninterruptible Power Supply) is a power backup device designed to provide temporary power to connected equipment during a power outage. The '2kVA' refers to its apparent power capacity, which is 2000 Volt-Amperes. This rating indicates the maximum power the UPS can supply to connected devices without overloading.
Here's a breakdown of what a Delta 2kVA UPS typically entails, based on the search results:
General Features and Specifications (may vary by model):
Topology: Often a true online double-conversion topology, which provides a consistent sine-wave output and zero transfer time to battery, ensuring high reliability for critical equipment.
Power Capacity: 2 kVA (kilovolt-amperes) / 1.6 kW to 1.8 kW (kilowatts), with a power factor of 0.8 to 0.9. The kilowatt rating indicates the real power the UPS can provide.
Input Voltage Range: Wide input voltage range, typically 110~300Vac or 175~280 Vac, allowing the UPS to work in various electrical environments and reducing battery usage.
Output Voltage: 220/230/240 Vac (single phase). Some models can also support 200/208 Vac.
Output Sockets: Equipped with IEC C13 and/or IEC C19 outlets, and in some models, Indian standard sockets.
Battery: Uses Sealed Maintenance-Free (SMF) batteries, with a DC bus voltage of 48 VDC or 72 VDC depending on the model.
Backup Time: Backup time varies depending on the load and the battery capacity. Some models offer:
10-15 minutes at full load with internal batteries.
Longer backup times (30-40 min, 45-60 min, 70-80 min, 110-120 min) are available with internal batteries in some models or with optional external battery packs.
Charger: Maximum charging current of up to 6A or 12A in some extended run models. Recharge time is typically around 3 hours to reach 90% capacity.
Efficiency: High AC-AC efficiency, up to 90-93% in online mode, leading to energy savings.
Input Power Factor: High input power factor (e.g., > 0.99) with PFC (Power Factor Correction), reducing input harmonic distortion and saving upstream investment.
Overload Capability: Varies by model but typically includes continuous operation up to 105% load and short durations at higher overloads.
Communication Interfaces: Usually includes RS-232, USB ports, and a mini slot for optional cards like SNMP for network management.
Display: LCD display for status and control, often multilingual.
Audible Noise: Typically less than 50 dBA at 1 meter.
Dimensions and Weight: Compact designs are available, with dimensions varying by model (e.g., around 397 x 145 x 220 mm and weights around 6-13 kg for some INX series models). Rack-mountable options (RT series) also exist with different dimensions and weights (e.g., 440W x 432D x 89H mm, 18 kg for RT 2kVA).
Protection: Offers protection against over voltage, deep battery discharge, overload, and short circuits.
ECO Mode: Some models feature an ECO mode for energy cost savings.
Cold Start Capability: Allows the UPS to be started with battery power when utility power is out.
Automatic Bypass: Transfers the load to mains in case of overload or internal fault.
Intelligent Battery Management: Maximizes battery performance and life.
Fan Speed Control: Optimizes performance by adjusting fan speed based on load and temperature.
Delta UPS Series that may include 2kVA models:
Amplon INX Series: A premier online double-conversion UPS series with high input power factor and AC-AC efficiency. Available in standard and extended runtime models, some with internal batteries (SB) and some for external batteries (LB).
Amplon R Series: Rack-mountable online double-conversion UPS, known for its compact size and high efficiency.
Amplon RT Series: Versatile rack/tower convertible UPS with high output power factor and efficiency, some models with internal batteries.
Keywords
613 kg
220 mm
50 dba
3 hours
2000 voltamperes
105 load
48 vdc
full load
model topology
acac efficiency
72 vdc depending
kilowatt rating
models feature
dimensions varying
1 meter dimensions
optional cards
mini slot
short durations
electrical environments
175280 vac allowing
18 kw kilowatts
transfer time
overloading heres
connected devices
connected equipment
utility power
battery power
real power
power factor
maximum power
power outage
compact size
eco mode
battery capacity
2kva refers
internal batteries
delta 2kva ups
extended runtime models
internal batteries sb
apparent power capacity
provide temporary power
weight compact designs
online mode leading
automatic bypass transfers
dc bus voltage
consistent sinewave output