Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

UNIVERSALPOWERSYSTEMF82C 6543468cae4e1df6fbef3986 Products https://locations.universalpower.co.in/bhiwadi
{ "products": [ { "_id": "67de4bd9042ffb8bd0390aa7", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Powerstack battery Testing ", "description": "Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition:\n\nSteps to Test Powerstack Batteries:\n1. Visual Inspection\nCheck for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced.\n\nClean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water.\n\n2. Check Battery Voltage\nMeasure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts.\n\nFor a 24V battery, you should see a voltage of around 25.2 to 26.0 volts.\n\nUndercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty.\n\n3. Load Testing\nTest under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak.\n\nDC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff.\n\n4. Battery Charge Test\nCharge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size.\n\nMonitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger.\n\nEnd of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery.\n\n5. Conduct a Specific Gravity Test (for Lead-Acid Batteries)\nHydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty.\n\n6. Perform a Battery Health Check (Advanced)\nUse a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs.\n\nInternal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life.\n\n7. Monitor for Temperature\nBatteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system.\n\nSigns of a Failing Battery:\nRapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating.\n\nShort Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life.\n\nInconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery.\n\nPhysical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced.\n\nBattery Maintenance Tips:\nRegular Charging: Avoid deep discharges and always keep the battery charged.\n\nEnvironmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures.\n\nPeriodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly.\n\nUse the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging.\n\nConclusion:\nBattery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 248, "imageuri": "https://bizimages.withfloats.com/actual/7f2c78a976e246efbe70882f742a421a.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/f8db1555dfa447dbb73d3446e6b45940.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-22T05:34:17.551Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/powerstack-battery-testing-/248", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Powerstack battery Testing ", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67f4bba3414e7cbef64febbb", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Battery Testing In Sonipat", "description": "Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details:\n\nTypes of Tests:\n\nVoltage Test: Measures the battery's output voltage to check if it meets the specified range.\n\nCapacity Test: Assesses how much charge the battery can hold and deliver over time.\n\nLoad Test: Simulates real-world usage to check how the battery performs under load.\n\nInternal Resistance Test: Evaluates the battery's internal resistance, indicating its health.\n\nTools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers.\n\nFrequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures.\n\nIndicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage.\n\nProper battery testing helps in proactive maintenance, ensuring reliability and safety.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "battery performs", "battery testing", "physical damage", "multimeter hydrometer", "health tools", "sonipatbattery testing", "backup power systems", "batterys output voltage", "key details types" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 252, "imageuri": "https://bizimages.withfloats.com/actual/c913575dfda84449995beac189bf35a3.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/c913575dfda84449995beac189bf35a3.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-04-08T06:01:07.782Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/battery-testing-in-sonipat/252", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Battery Testing In Sonipat", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67de50f12d762c4c27178365", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Quanta 12v 42Ah Battery", "description": "The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial.\n\nKey Features of Amaron Quanta 42Ah Battery:\nCapacity:\n\n42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load.\n\nTechnology:\n\nMaintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free.\n\nHigh Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter.\n\nDeep Cycle Battery:\n\nThis is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently.\n\nDurability:\n\nLong Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored.\n\nHigh-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions.\n\nDesign:\n\nCompact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern.\n\nVibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings.\n\nSafety Features:\n\nFlame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction.\n\nLeak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety.\n\nApplication Areas:\n\nUPS Systems: Provides backup power to computers, servers, and networking equipment.\n\nInverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages.\n\nSolar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night.\n\nWarranty:\n\nThe Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details.\n\nGeneral Specifications:\nVoltage: 12V (standard for most UPS and inverter batteries).\n\nCapacity: 42Ah.\n\nType: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat).\n\nCharging Voltage: Typically around 14.4 to 15.0V for 12V batteries.\n\nNominal Voltage: 12V.\n\nDimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model).\n\nWeight: Approximately 12-14 kg.\n\nMaintenance Tips for the Amaron Quanta 42Ah Battery:\nRegular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan.\n\nStorage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically.\n\nClean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed.\n\nAvoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it.\n\nCheck for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear.\n\nBattery Testing:\nTo check the health of the Amaron Quanta 42Ah battery, you can follow these steps:\n\nVoltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V.\n\nLoad Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation.\n\nCapacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold.\n\nConclusion:\nThe Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 249, "imageuri": "https://bizimages.withfloats.com/actual/1d085d444be04b38886a66b6877f7848.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/6ffad887d34b4ebd8fcc808aeb3d9a29.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-22T05:56:01.145Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-42ah-battery/249", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Amaron Quanta 12v 42Ah Battery", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d905d2a368d6b4e8edd8af", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "VERTIV UPS", "description": "The Liebert APM is a modular, scalable, and flexible Uninterruptible Power Supply (UPS) system from Vertiv (formerly Emerson Network Power). It's designed to provide reliable power protection for a wide range of applications, including IT, industrial, healthcare, and telecommunication environments. The Liebert APM series comes in various power ratings, with the range you mentioned being 30 kW - 300 kW, as well as the smaller 1 to 25 kVA units, offering high flexibility for different power requirements.\n\nKey Features of the Liebert APM Series:\nModular Design:\n\nOne of the standout features of the Liebert APM UPS system is its modular design. This allows users to scale the system based on their current needs and future expansion. The modular units can be added incrementally, making it highly adaptable.\nThis modular approach allows for easy maintenance and upgrades without having to replace the entire UPS unit.\nHigh Efficiency:\n\nThe Liebert APM delivers high efficiency, typically achieving up to 95% or more under normal operating conditions. This efficiency helps reduce operational costs and energy consumption.\nIt also features Eco-mode operation, which optimizes energy savings when operating in non-critical situations without compromising protection.\nCompact and Flexible:\n\nDespite its modular nature, the Liebert APM system has a compact design that fits easily into most data centers and industrial setups, where space can often be at a premium.\nIt can be configured for 1-phase or 3-phase power supply, offering flexibility for different types of loads and systems.\nScalable Power:\n\nThe Liebert APM is available in a range from 1 kVA to 300 kVA, which makes it suitable for small server rooms to large data centers.\nThe system allows for easy scalability by adding additional power modules as needed to meet growing demands.\nFlexible Battery Configurations:\n\nThe UPS system supports a variety of battery configurations, allowing for customization based on your runtime requirements. You can select from different battery types, including VRLA (Valve-Regulated Lead-Acid) and lithium-ion batteries.\nAdvanced Monitoring and Management:\n\nLiebert APM comes with Intelligent Monitoring that provides real-time data on the UPS’s performance, such as input/output voltage, battery status, and efficiency.\nIt supports both local and remote monitoring, ensuring that technicians can be alerted to issues before they become critical problems.\nThe system can be integrated with network management systems (NMS) for centralized control across multiple units.\nDual Input Capability:\n\nSome models of the Liebert APM offer dual input power sources, providing redundancy for critical applications. This feature ensures that the system remains operational even if one power input fails.\nFast Response Time:\n\nThe Liebert APM offers a fast transfer time (typically in the milliseconds), ensuring that sensitive equipment is protected even during brief power outages or voltage fluctuations.\nApplications:\nData Centers: Providing reliable, scalable power protection for server rooms and IT infrastructure.\nIndustrial: Protecting critical manufacturing equipment and automated systems from power interruptions.\nHealthcare: Ensuring medical equipment, including imaging devices, lab instruments, and patient monitoring systems, remain operational during power outages.\nTelecommunications: Keeping communication systems up and running to ensure continuous operation of vital network infrastructure.\nBenefits:\nScalability: The ability to scale up or down as required, which is a huge benefit for growing businesses or changing environments.\nReduced Total Cost of Ownership (TCO): With high efficiency and modularity, the Liebert APM reduces energy consumption and minimizes the cost of maintenance.\nReliability: Known for providing excellent protection against power issues, including surges, spikes, and outages.\nCustomization: Supports different configurations and battery options to meet specific needs, offering flexibility across various industries.\nModels & Power Ratings:\nSmall Power Ratings: For smaller environments or edge computing setups, Liebert APM models ranging from 1 kVA to 25 kVA offer robust protection without being overly complex.\nLarge Power Ratings: For larger industrial or data center applications, the 30 kW to 300 kW versions provide scalable power protection to ensure high availability for critical operations.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 239, "imageuri": "https://bizimages.withfloats.com/actual/930d91046d2046bb95b2598748fed6f3.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/930d91046d2046bb95b2598748fed6f3.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-18T05:34:10.095Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-ups/239", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "VERTIV UPS", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d7f2ab186166ef64e40639", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Vertiv 10kVA UPS", "description": "A Vertiv 10kVA UPS (Uninterruptible Power Supply) is a reliable power backup system designed to provide uninterrupted power to critical equipment, such as servers, networking devices, and other sensitive electronic systems. The 10kVA rating indicates that the UPS can handle loads of up to 10,000 volt-amperes, which is typically suitable for medium-sized office setups or small data centers.\n\nVertiv (formerly Emerson Network Power) is known for offering high-quality, efficient, and reliable UPS solutions that help prevent downtime and protect equipment from power surges, outages, and other electrical disturbances.\n\nHere are some key features you might find in a Vertiv 10kVA UPS:\n\nPower Capacity:\n\n10 kVA (or approximately 8 kW for resistive loads), which can support multiple servers or network equipment.\nEfficiency:\n\nMany Vertiv UPS systems are designed with energy efficiency in mind, minimizing energy loss and operating costs.\nBattery Type:\n\nTypically uses either VRLA (Valve Regulated Lead Acid) or Lithium-Ion batteries, providing long-lasting backup time during power interruptions.\nForm Factor:\n\nThese systems may come in both rack-mounted or tower configurations, depending on space requirements.\nScalability:\n\nSome Vertiv UPS units allow for modular expansion, meaning you can add additional units or battery packs to increase power capacity.\nMonitoring and Control:\n\nAdvanced models often come with digital monitoring features, allowing remote monitoring of UPS status, battery health, and power consumption via web interfaces or software.\nSurge Protection and Isolation:\n\nProtects your sensitive equipment from power surges, voltage spikes, and electrical noise.\nMaintenance Bypass:\n\nMany UPS models, including 10kVA versions, have maintenance bypass switches that allow you to service the unit without interrupting power to connected devices.\nVertiv offers various UPS models in this range, so if you’re looking to purchase, it's important to check specifications for exact features, runtime, and compatibility with your equipment.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "10000 voltamperes", "check specifications", "10kva versions", "isolation protects", "web interfaces", "battery packs", "resistive loads", "approximately 8 kw", "electrical disturbances", "protect equipment", "prevent downtime", "typically suitable", "handle loads", "10kva rating", "critical equipment", "sensitive equipment", "energy efficiency", "key features", "interrupting power", "power consumption", "ups models", "network equipment efficiency", "vertiv ups systems", "sensitive electronic systems", "control advanced models", "vertiv ups units", "reliable ups solutions", "exact features runtime", "power surges outages", "emerson network power", "provide uninterrupted power", "maintenance bypass switches", "software surge protection", "add additional units", "modular expansion meaning", "space requirements scalability", "tower configurations depending", "support multiple servers", "offering highquality efficient", "mediumsized office setups", "servers networking devices" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 233, "imageuri": "https://bizimages.withfloats.com/actual/6626a89452cd42bd9e741a13bf32b58b.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/6626a89452cd42bd9e741a13bf32b58b.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-17T10:00:11.465Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-10kva-ups/233", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Vertiv 10kVA UPS", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d7b418ea1b912b02105269", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Quanta 12V 200Ah battery", "description": "The Amaron Quanta 12V 200Ah battery is a sealed maintenance-free (SMF) VRLA battery designed for high performance. It features a nominal voltage of 12 volts, a rated capacity of 200 ampere-hours, and dimensions of approximately 541 x 232 x 208 mm, weighing around 62 kg. Specifications\n\nBrand: Amaron Quanta\nModel: 12AL200\nBattery Type: Sealed Maintenance Free (SMF)\nVoltage: 12V\nCapacity: 200Ah\nDimensions: 556 x 186 x 263 mm\nWeight: 62 kg (± 5%)\nKey Features\n\nAGM Technology: Utilizes Absorbed Glass Mat technology for low maintenance and high reliability.\nSpill-Proof Design: Can be installed in any position without risk of leakage.\nHigh Discharge Performance: Lower internal resistance for superior performance during high discharge rates.\nFast Charging: Instacharge technology allows for excellent charge acceptance.\nDurability: Designed to withstand tropical environments and heavy usage.\nSafety Features: Includes a one-way self-resealing safety vent and flame-retardant components.\nApplications", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "approximately 541", "200 amperehours", "12 volts", "superior performance", "low maintenance", "208 mm weighing", "rated capacity", "nominal voltage", "high performance", "flameretardant components applications", "withstand tropical environments" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 232, "imageuri": "https://bizimages.withfloats.com/actual/3c804d0c86ea4d368272b4e42fb5ea61.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/3c804d0c86ea4d368272b4e42fb5ea61.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-17T05:33:12.199Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-200ah-battery/232", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Amaron Quanta 12V 200Ah battery", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d52d8a4507f670f3d4fa58", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Emerson 3-Phase Ups In Manesar", "description": "Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues.\n\nKey Features of Emerson 3-Phase UPS:\nPower Capacity:\n\n3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model.\nSuitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings.\nTechnology:\n\nDouble Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging.\nEfficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs.\nBattery Management: Integrated advanced battery management for monitoring health, charge, and backup times.\nHigh Availability:\n\nDesigned to provide reliable power for mission-critical applications.\nHot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply.\nScalability: Many models allow for modular expansion, meaning you can add additional capacity as needed.\nInput/Output Voltage:\n\nInput Voltage: Common input voltages are 380V, 400V, and 415V (3-phase).\nOutput Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards.\nPower Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency.\nAdvanced Features:\n\nLCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring.\nRemote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics.\nBypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime.\nDesign and Durability:\n\nCompact Design: Many models are designed to be space-efficient without compromising on power or cooling needs.\nRack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs.\nThermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating.\nApplications:\n\nData Centers: Ensures uptime for servers and networking equipment.\nIndustrial Equipment: Protects critical machinery and automated systems from power failures.\nTelecommunications: Keeps communication systems running without interruption.\nHospitals: Supports life-saving equipment and systems that require constant power.\nCommercial Buildings: Ensures backup power for office systems and equipment.\nMaintenance and Service:\n\nSmart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required.\nServiceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition.\nProactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations.\nPopular Models:\nEmerson (now part of Vertiv) offers various UPS models under different series, such as:\n\nVertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications.\nVertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability.\nVertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications.\nAdvantages of Emerson 3-Phase UPS:\nHigh Reliability: Ensures critical equipment remains powered during power failures or fluctuations.\nAdvanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility.\nEnergy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact.\nScalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand.\n\nConclusion:\nEmerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "800 kva", "10 kva", "models batteries", "equipment maintenance", "small office", "380v 400v", "largescale facilities", "ups models", "excellent solutions", "easily expand", "data centers", "remote monitoring", "service contracts", "comprehensive support", "alert users", "realtime alerts", "remote access", "realtime data", "model suitable", "wide range", "ups remains", "office systems", "automated systems", "offers scalability", "vertiv offers", "bypass mode", "industrial commercial", "robust design", "higher depending", "critical infrastructure", "power failures", "monitoring health charge", "modular ups system", "advanced cooling systems", "emerson ups systems", "ups systems typically", "ensure uninterrupted operation", "3phase systems depending", "critical infrastructure applications", "power failures telecommunications", "emerson 3phase ups", "communication systems running", "environmental impact scalability", "industrial applications advantages", "vertiv liebert ita2", "diagnostics bypass capability", "high power factor", "provide reliable power", "power capacities generally", "provide uninterrupted power", "tower formats depending", "durability compact design", "avoid downtime design", "require high uptime", "flexibility energy efficiency", "diagnostic tools faults", "maintain efficient operation", "add additional capacity", "modular expansion meaning", "reduce energy consumption" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 229, "imageuri": "https://bizimages.withfloats.com/actual/187708a304fa44f1b41acc0e625a7a30.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/187708a304fa44f1b41acc0e625a7a30.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-15T07:34:34.549Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/emerson-3-phase-ups-in-manesar/229", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Emerson 3-Phase Ups In Manesar", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67ca9cb25716f22e86601481", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "All Types Of Ups & Batteries Repair And Maintenance Of Ups", "description": "Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices.\n\nTypes of UPS Systems\nOffline/Standby UPS:\n\nDescription: Provides basic protection; switches to battery during a power outage.\nMaintenance: Regular battery checks and replacement every 3-5 years.\nLine-Interactive UPS:\n\nDescription: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations.\nMaintenance: Inspect and test the battery and inverter regularly; check for dust accumulation.\nOnline Double-Conversion UPS:\n\nDescription: Provides continuous power and isolates equipment from power issues.\nMaintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates.\nModular UPS:\n\nDescription: Scalable systems that allow for adding or removing modules based on power needs.\nMaintenance: Regular checks on each module, ensuring proper connections and functionality.\nTypes of Batteries Used in UPS\nLead-Acid Batteries:\n\nTypes: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel.\nMaintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity.\nLithium-Ion Batteries:\n\nDescription: Increasingly used due to longer life and lighter weight.\nMaintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates.\nNickel-Cadmium (NiCd) Batteries:\n\nDescription: Used in specific applications; known for durability.\nMaintenance: Regularly test for capacity and perform equalization charging.\nRepair and Maintenance Practices\n1. Routine Inspections\nVisual Checks: Inspect for physical damage, corrosion, or loose connections.\nEnvironmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity).\n2. Battery Maintenance\nTesting: Conduct regular load tests and capacity tests to assess battery health.\nCleaning: Clean terminals and connections to prevent corrosion.\nReplacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid).\n3. UPS Maintenance\nFirmware Updates: Keep the UPS firmware updated for optimal performance.\nComponent Checks: Inspect capacitors, fans, and other internal components for wear and tear.\nCooling System: Ensure that cooling fans are operational and that vents are not blocked.\n4. Emergency Procedures\nTesting: Regularly test the UPS under load conditions to ensure it functions correctly during an outage.\nDocumentation: Maintain records of all maintenance activities, repairs, and battery replacements.\n5. Professional Servicing\nScheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS.\nEmergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts.\nConclusion\nRegular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries.\n\nFor specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "35 years", "capacity tests", "functionality types", "tailored solutions", "significantly extend", "timely repairs", "rapid response", "comprehensive inspections", "functions correctly", "load conditions", "cooling fans", "internal components", "longer life", "continuous power", "comprehensive overview", "ups failures", "complex systems", "ups systems", "specific applications", "performance check", "isolates equipment", "ups batteries repair", "ups systems batteries", "maintenance practices types", "maintenance activities repairs", "power issues maintenance", "battery backup ideal", "ups firmware updated", "detailed maintenance plans", "specific service providers", "structured maintenance schedule", "protecting sensitive equipment", "maintenance regular checks", "inverter regularly check", "engaging professional services", "manufacturer recommendations typically", "physical damage corrosion", "removing modules based", "basic protection switches" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 202, "imageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-07T07:13:54.328Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/all-types-of-ups-batteries-repair-and-maintenance-of-ups/202", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "All Types Of Ups & Batteries Repair And Maintenance Of Ups", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67ca9ac4d70c788e10fe2e7a", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "ALL TYPES UPS & BATTERIES AMC", "description": "An Annual Maintenance Contract (AMC) for UPS systems typically includes routine maintenance, repair services, and emergency support to ensure optimal performance. It covers inspections, battery maintenance, and high-priority assistance during breakdowns, helping to extend the lifespan of your UPS and batteries. For more specific details, you can refer to the links provided in the search results. UPS AMC Services Overview:\n\nPurpose of AMC: The AMC is designed to provide comprehensive support for UPS systems, ensuring they operate efficiently and reliably. This includes regular maintenance, emergency repairs, and technical assistance.\n\nKey Components of AMC:\n\nRoutine Maintenance: Regular inspections and servicing to prevent issues before they arise.\nRepair Services: Quick response to any failures or malfunctions, minimizing downtime.\nEmergency Support: 24/7 assistance to address urgent issues.\nTypes of AMC Plans:\n\nPlatinum Plan:\n\nCovers all spare parts during maintenance, excluding natural calamities.\nHigh-priority assistance during breakdowns.\nRegular preventive maintenance and detailed reports with recommendations.\nGold Plan:\n\nSimilar to the Platinum plan but does not include standby units.\nFocuses on critical equipment maintenance.\nSilver Plan:\n\nBasic support with engineers and technical assistance only.\nMaintenance Schedule:\n\nMonthly Checks:\n\nVisual inspections of batteries and connections.\nMeasurement of ambient temperature and humidity.\nCleaning of the UPS environment.\nQuarterly Checks:\n\nVoltage measurement of each battery cell.\nConductance testing for battery health.\nYearly Checks:\n\nTorque measurement of all connections.\nTesting of interconnecting cable resistance.\nImportance of Battery Maintenance:\n\nRegular maintenance is crucial as battery failures account for a significant percentage of UPS failures. Environmental conditions can greatly affect battery life, with temperature fluctuations leading to reduced performance.\nContact Information:\n\nFor inquiries or to set up an AMC, you can reach out via:\nEmail: info@universalpower.co.in\nPhone: 8744823336", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "significant percentage", "connections testing", "humidity cleaning", "connections measurement", "technical assistance", "platinum plan", "detailed reports", "spare parts", "prevent issues", "operate efficiently", "links provided", "specific details", "breakdowns helping", "highpriority assistance", "ambient temperature", "emergency support", "battery failures account", "ups systems ensuring", "temperature fluctuations leading", "provide comprehensive support", "standby units focuses", "ensure optimal performance" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 201, "imageuri": "https://bizimages.withfloats.com/actual/df07ef29e82c449c843b62b833b9ed63.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/df07ef29e82c449c843b62b833b9ed63.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-07T07:05:40.029Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//all-types-ups-batteries-amc/201", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "ALL TYPES UPS & BATTERIES AMC", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
battery health?

Still searching for
battery health?

Chat with us