Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "67de4bd9042ffb8bd0390aa7",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Powerstack battery Testing ",
"description": "Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition:\n\nSteps to Test Powerstack Batteries:\n1. Visual Inspection\nCheck for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced.\n\nClean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water.\n\n2. Check Battery Voltage\nMeasure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts.\n\nFor a 24V battery, you should see a voltage of around 25.2 to 26.0 volts.\n\nUndercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty.\n\n3. Load Testing\nTest under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak.\n\nDC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff.\n\n4. Battery Charge Test\nCharge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size.\n\nMonitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger.\n\nEnd of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery.\n\n5. Conduct a Specific Gravity Test (for Lead-Acid Batteries)\nHydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty.\n\n6. Perform a Battery Health Check (Advanced)\nUse a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs.\n\nInternal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life.\n\n7. Monitor for Temperature\nBatteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system.\n\nSigns of a Failing Battery:\nRapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating.\n\nShort Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life.\n\nInconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery.\n\nPhysical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced.\n\nBattery Maintenance Tips:\nRegular Charging: Avoid deep discharges and always keep the battery charged.\n\nEnvironmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures.\n\nPeriodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly.\n\nUse the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging.\n\nConclusion:\nBattery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 248,
"imageuri": "https://bizimages.withfloats.com/actual/7f2c78a976e246efbe70882f742a421a.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/f8db1555dfa447dbb73d3446e6b45940.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-22T05:34:17.551Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/powerstack-battery-testing-/248",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Powerstack battery Testing ",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67189ab9762edbb288f82b42",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Amaron Quanta 100Ah battery In Chirhara",
"description": "The Amaron Quanta 100Ah battery is designed for reliable power backup, particularly in applications like telecom, UPS systems, and industrial use. Here are the key details:\n\nSpecifications\nVoltage: 12V\nCapacity: 100Ah\nType: Sealed Maintenance Free (SMF) Lead-Acid Battery\nTechnology: Advanced lead-calcium technology for enhanced performance.\n\nKey Features\nMaintenance-Free: No need for regular electrolyte topping, making it user-friendly.\nLong Life: Designed for extended service life with minimal degradation over time.\nHigh Durability: Built to withstand harsh operating conditions, including temperature fluctuations.\nDeep Discharge Capability: Suitable for applications that require deep cycling.\nVibration Resistance: Can endure vibrations, making it ideal for industrial environments.\n\nApplications\nTelecommunications: Provides backup power for telecom equipment and infrastructure.\nUPS Systems: Used in uninterruptible power supplies for critical loads.\nSolar Energy: Suitable for solar applications where energy storage is necessary.\nIndustrial Use: Powers machinery and equipment requiring reliable energy.\nPhysical Characteristics\nDimensions: Approximately 330 mm x 170 mm x 220 mm (length x width x height).\nWeight: Around 30-35 kg (exact weight may vary slightly).\n\nSafety Features\nValve-Regulated: Prevents leakage and spillage of electrolytes.\nThermal Management: Built to operate safely within specified temperature ranges.\nShort Circuit Protection: Designed to disconnect safely in the event of a short circuit.\n\nWarranty\nTypically comes with a warranty of 18 months to 2 years, depending on usage and application.\n\nMaintenance Tips\nAlthough maintenance-free, check terminals for cleanliness and tightness periodically.\nEnsure the battery is kept in a well-ventilated area to avoid overheating.\n\nConclusion\nThe Amaron Quanta 100Ah battery is a reliable solution for a variety of applications, offering excellent performance with minimal maintenance. ",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"220 mm",
"170 mm",
"330 mm",
"2 years",
"30-35 kg",
"18 months",
"Long Life",
"100Ah Type",
"key details",
"UPS systems",
"exact weight",
"Solar Energy",
"12V Capacity",
"deep cycling",
"Key Features",
"backup power",
"energy storage",
"critical loads",
"industrial use",
"ventilated area",
"High Durability",
"reliable energy",
"Powers machinery",
"Maintenance Tips",
"telecom equipment",
"reliable solution",
"solar applications",
"temperature ranges",
"Thermal Management",
"minimal degradation",
"minimal maintenance",
"Vibration Resistance",
"enhanced performance",
"excellent performance",
"reliable power backup",
"Safety Features Valve",
"extended service life",
"Specifications Voltage",
"industrial environments",
"Sealed Maintenance Free",
"temperature fluctuations",
"Short Circuit Protection",
"Deep Discharge Capability",
"harsh operating conditions",
"regular electrolyte topping",
"uninterruptible power supplies",
"The Amaron Quanta 100Ah battery",
"Advanced lead-calcium technology",
"SMF) Lead-Acid Battery Technology",
"Physical Characteristics Dimensions"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 99,
"imageuri": "https://bizimages.withfloats.com/actual/bb3d5a7a66184e7385bf973ffe966e42.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/bb3d5a7a66184e7385bf973ffe966e42.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-23T06:42:01.709Z",
"updatedon": "2024-10-23T06:42:01.709Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-100ah-battery-in-chirhara/99",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Battery",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67de50f12d762c4c27178365",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Amaron Quanta 12v 42Ah Battery",
"description": "The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial.\n\nKey Features of Amaron Quanta 42Ah Battery:\nCapacity:\n\n42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load.\n\nTechnology:\n\nMaintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free.\n\nHigh Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter.\n\nDeep Cycle Battery:\n\nThis is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently.\n\nDurability:\n\nLong Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored.\n\nHigh-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions.\n\nDesign:\n\nCompact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern.\n\nVibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings.\n\nSafety Features:\n\nFlame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction.\n\nLeak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety.\n\nApplication Areas:\n\nUPS Systems: Provides backup power to computers, servers, and networking equipment.\n\nInverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages.\n\nSolar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night.\n\nWarranty:\n\nThe Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details.\n\nGeneral Specifications:\nVoltage: 12V (standard for most UPS and inverter batteries).\n\nCapacity: 42Ah.\n\nType: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat).\n\nCharging Voltage: Typically around 14.4 to 15.0V for 12V batteries.\n\nNominal Voltage: 12V.\n\nDimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model).\n\nWeight: Approximately 12-14 kg.\n\nMaintenance Tips for the Amaron Quanta 42Ah Battery:\nRegular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan.\n\nStorage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically.\n\nClean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed.\n\nAvoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it.\n\nCheck for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear.\n\nBattery Testing:\nTo check the health of the Amaron Quanta 42Ah battery, you can follow these steps:\n\nVoltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V.\n\nLoad Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation.\n\nCapacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold.\n\nConclusion:\nThe Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 249,
"imageuri": "https://bizimages.withfloats.com/actual/1d085d444be04b38886a66b6877f7848.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/6ffad887d34b4ebd8fcc808aeb3d9a29.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-22T05:56:01.145Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-42ah-battery/249",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Amaron Quanta 12v 42Ah Battery",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d5328fdb7fc0f04f83af80",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Battery Replacement In Faridabad",
"description": "Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each.\n\nTypes of Batteries and Their Replacement Process\n1. Lead-Acid Batteries\nCommon Types:\nFlooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells.\nSealed Lead-Acid (SLA): Maintenance-free and does not require water addition.\nAbsorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats.\nGel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications.\nReplacement Process:\nTurn off the system: Ensure the system is powered off, and disconnect it from the grid or load.\nSafety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases.\nDisconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal.\nRemove old batteries: Lift and remove the batteries carefully, especially if they're heavy.\nClean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water.\nInstall new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system and check the voltage and charging status.\nMaintenance Tips:\nRegularly check the electrolyte levels in flooded batteries.\nClean terminals and ensure the battery box or tray is secure.\n2. Lithium-Ion Batteries\nCommon Types:\nLithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan.\nLithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools.\nLithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications.\nLithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones.\nReplacement Process:\nTurn off the system: Disconnect the power source or system.\nSafety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage.\nDisconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal.\nRemove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries.\nInstall the new battery: Place the new battery in the same orientation and secure it.\nReconnect terminals: Attach the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly.\nMaintenance Tips:\nLithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range.\nBattery Management System (BMS) should be monitored to ensure proper functioning and safety.\n\nConclusion:\nBattery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation.\n\nLead-acid batteries need regular maintenance, especially flooded types.\nLithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance.\nAlways follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"system disconnect",
"common types",
"system ensure",
"replacement process",
"battery place",
"battery box",
"electrolyte levels",
"gel electrolyte",
"sla battery",
"battery replacement",
"system power",
"handling batteries",
"longer lifespan",
"batterys charging",
"typically lighter",
"handled carefully",
"generally safe",
"small devices",
"highpower applications",
"high efficiency",
"evs due",
"batteries place",
"baking soda",
"batteries carefully",
"batteries lift",
"sulfuric acid",
"ill provide",
"vary depending",
"batterypowered devices",
"faridabadbattery replacement",
"minimal maintenance",
"regular maintenance",
"power source",
"leadacid batteries",
"power systems",
"solar systems",
"positive terminal",
"water install",
"negative terminal",
"battery lithiumion batteries",
"leadacid batteries install",
"reconnect terminals attach",
"positive terminal remove",
"solar systems leadacid",
"evs power tools",
"negative terminal check",
"common maintenance task",
"installation leadacid batteries",
"ensure proper recycling",
"ensure proper functioning",
"drones power banks",
"adding distilled water",
"avoid environmental hazards",
"follow safety guidelines",
"requiring specific attention",
"avoid overheating shortcircuiting"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 231,
"imageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-15T07:55:59.544Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/battery-replacement-in-faridabad/231",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Battery Replacement In Faridabad",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d52a2079019484efe3a8ff",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Amaron Quanta 12V 130Ah Battery In Bhiwadi",
"description": "The Amaron Quanta 12V 130Ah batteries are lead-acid batteries typically used for solar power storage, backup power systems, and other applications that require reliable energy storage. Here's a detailed overview of this battery:\n\nKey Features of Amaron Quanta 12V 130Ah Battery:\nBattery Type:\n\nLead-Acid: This is a type of flooded or sealed (VRLA) lead-acid battery, suitable for deep cycle applications.\n12V System: Designed for systems that operate on a 12V DC supply, often used in small-scale solar energy systems, inverters, and backup power setups.\nCapacity:\n\n130Ah (Ampere-hour): This indicates the battery’s storage capacity. It means the battery can deliver 130 amps for 1 hour or 1 amp for 130 hours at a nominal voltage of 12V.\nFor example, if the system uses 1A of current, the battery will last for around 130 hours before needing a recharge.\nApplications:\n\nSolar Power Systems: To store energy generated by solar panels.\nUPS (Uninterruptible Power Supply): Provides backup during power outages.\nOff-Grid Systems: Stores energy for homes or businesses in remote areas.\nElectric Vehicles and RVs: Sometimes used for backup and auxiliary power.\nCharging and Discharging:\n\nCharging: The battery can be charged through solar panels, inverters, or a regular charger. It is recommended to avoid deep discharges to extend the battery life.\nDischarging: It should not be discharged fully for longevity. Typically, a depth of discharge (DoD) of 50% to 70% is ideal for long-term use.\nBattery Life:\n\nCycle Life: Typically, a lead-acid battery like the Amaron Quanta 12V 130Ah can last around 3-5 years, depending on usage and maintenance.\nProper charging and maintenance (like keeping the terminals clean and ensuring adequate ventilation) can improve the lifespan of the battery.\nAdvantages:\n\nReliable and Cost-Effective: Lead-acid batteries are typically less expensive than other types of batteries, like lithium-ion.\nWidely Available: Amaron is a well-known brand, and their batteries are widely available and easy to replace.\nMaintenance:\n\nFlooded Lead-Acid: If it’s a flooded type, you may need to periodically check the water levels and top up with distilled water.\nVRLA (Valve-Regulated Lead-Acid): If it's a sealed type, it requires less maintenance as it’s sealed and does not need water refills.\nSpecifications:\n\nVoltage: 12V\nCapacity: 130Ah\nWeight: Around 40-45 kg (approx.), depending on the specific model and construction type.\nDimensions: Varies by model, but typically it is about 410mm (L) x 175mm (W) x 240mm (H).\nConclusion:\nThe Amaron Quanta 12V 130Ah battery is a good choice for off-grid solar systems, backup power applications, or any system requiring long-lasting energy storage. It offers a solid balance of performance, cost-effectiveness, and reliability. Proper care and maintenance will ensure it provides reliable service for years to come.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"130 hours",
"1 amp",
"1 hour",
"sealed type",
"flooded type",
"specific model",
"lithiumion widely",
"35 years depending",
"longevity typically",
"performance costeffectiveness",
"solid balance",
"good choice",
"water levels",
"periodically check",
"wellknown brand",
"terminals clean",
"discharge dod",
"discharged fully",
"regular charger",
"nominal voltage",
"deliver 130 amps",
"detailed overview",
"reliable service",
"leadacid battery",
"discharging charging",
"leadacid batteries typically",
"maintenance proper charging",
"battery advantages reliable",
"battery life discharging",
"costeffective leadacid batteries",
"12v dc supply",
"battery key features",
"auxiliary power charging",
"reliability proper care",
"ensuring adequate ventilation",
"avoid deep discharges",
"solar panels inverters",
"store energy generated",
"batterys storage capacity"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 227,
"imageuri": "https://bizimages.withfloats.com/actual/ba8dda1eb6ab4cf2a1abfcc8de098663.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/ba8dda1eb6ab4cf2a1abfcc8de098663.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-15T07:20:00.489Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-130ah-battery-in-bhiwadi/227",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Amaron Quanta 12V 130Ah Battery In Bhiwadi",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d13de22912ddb97fcecda8",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Maintenance Tips for UPS Systems and Batteries",
"description": "Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips:\n\n1. Regular Inspection\nVisual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion.\nConnections: Ensure that all connections are secure and free from dust and corrosion.\n2. Battery Maintenance\nBattery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load.\nClean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting.\nCheck Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed.\n3. Environmental Considerations\nTemperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly.\nVentilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow.\n4. Regular Testing\nSelf-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature.\nLoad Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage.\n5. Firmware and Software Updates\nKeep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security.\nMonitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues.\n6. Battery Replacement\nFollow Manufacturer Guidelines: Replace batteries according to the manufacturer\\'s recommendations, typically every 3-5 years for lead-acid batteries.\nDispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety.\n7. Load Management\nAvoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life.\nBalanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded.\n8. Documentation\nKeep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance.\n9. Professional Maintenance\nSchedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems.\n10. User Training\nEducate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"35 years",
"maintenance tips",
"ups system",
"ups systems",
"rated capacity",
"distilled water",
"power outage",
"issues encountered",
"records maintain",
"overloaded 8 documentation",
"single outlet",
"receive alerts",
"functioning correctly",
"enclosed spaces",
"baking soda",
"check voltage",
"improve performance",
"ensure terminals",
"load evenly",
"required load",
"battery tester",
"software updates",
"corrosion connections ensure",
"ups monitoring software",
"leadacid batteries dispose",
"battery terminals clean",
"load clean terminals",
"track performance metrics",
"ensuring reliable performance",
"total load connected",
"install firmware updates",
"security monitoring software",
"manufacturers recommendations typically",
"electrolyte levels regularly",
"physical damage leaks"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 221,
"imageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-12T07:55:14.561Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/maintenance-tips-for-ups-systems-and-batteries-/221",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Maintenance Tips for UPS Systems and Batteries",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67ca9cb25716f22e86601481",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "All Types Of Ups & Batteries Repair And Maintenance Of Ups",
"description": "Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices.\n\nTypes of UPS Systems\nOffline/Standby UPS:\n\nDescription: Provides basic protection; switches to battery during a power outage.\nMaintenance: Regular battery checks and replacement every 3-5 years.\nLine-Interactive UPS:\n\nDescription: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations.\nMaintenance: Inspect and test the battery and inverter regularly; check for dust accumulation.\nOnline Double-Conversion UPS:\n\nDescription: Provides continuous power and isolates equipment from power issues.\nMaintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates.\nModular UPS:\n\nDescription: Scalable systems that allow for adding or removing modules based on power needs.\nMaintenance: Regular checks on each module, ensuring proper connections and functionality.\nTypes of Batteries Used in UPS\nLead-Acid Batteries:\n\nTypes: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel.\nMaintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity.\nLithium-Ion Batteries:\n\nDescription: Increasingly used due to longer life and lighter weight.\nMaintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates.\nNickel-Cadmium (NiCd) Batteries:\n\nDescription: Used in specific applications; known for durability.\nMaintenance: Regularly test for capacity and perform equalization charging.\nRepair and Maintenance Practices\n1. Routine Inspections\nVisual Checks: Inspect for physical damage, corrosion, or loose connections.\nEnvironmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity).\n2. Battery Maintenance\nTesting: Conduct regular load tests and capacity tests to assess battery health.\nCleaning: Clean terminals and connections to prevent corrosion.\nReplacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid).\n3. UPS Maintenance\nFirmware Updates: Keep the UPS firmware updated for optimal performance.\nComponent Checks: Inspect capacitors, fans, and other internal components for wear and tear.\nCooling System: Ensure that cooling fans are operational and that vents are not blocked.\n4. Emergency Procedures\nTesting: Regularly test the UPS under load conditions to ensure it functions correctly during an outage.\nDocumentation: Maintain records of all maintenance activities, repairs, and battery replacements.\n5. Professional Servicing\nScheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS.\nEmergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts.\nConclusion\nRegular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries.\n\nFor specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"35 years",
"capacity tests",
"functionality types",
"tailored solutions",
"significantly extend",
"timely repairs",
"rapid response",
"comprehensive inspections",
"functions correctly",
"load conditions",
"cooling fans",
"internal components",
"longer life",
"continuous power",
"comprehensive overview",
"ups failures",
"complex systems",
"ups systems",
"specific applications",
"performance check",
"isolates equipment",
"ups batteries repair",
"ups systems batteries",
"maintenance practices types",
"maintenance activities repairs",
"power issues maintenance",
"battery backup ideal",
"ups firmware updated",
"detailed maintenance plans",
"specific service providers",
"structured maintenance schedule",
"protecting sensitive equipment",
"maintenance regular checks",
"inverter regularly check",
"engaging professional services",
"manufacturer recommendations typically",
"physical damage corrosion",
"removing modules based",
"basic protection switches"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 202,
"imageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-07T07:13:54.328Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/all-types-of-ups-batteries-repair-and-maintenance-of-ups/202",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "All Types Of Ups & Batteries Repair And Maintenance Of Ups",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "672c53984c2d7366708cbc86",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 2kva Ups Repair In Milakpur Goojar Bhiwadi",
"description": "Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations.\n\nWhen a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair:\n\nCommon Problems in Vertiv 2kVA UPS\nUPS Not Turning On\n\nPossible Causes:\nFaulty battery or dead battery\nBlown fuse or circuit breaker\nPower supply input issue (fuse or switch)\nRepair Action:\nCheck and replace the battery if necessary.\nInspect the fuse or circuit breaker and replace if blown.\nVerify the input power connections.\nFrequent Switching to Battery Mode\n\nPossible Causes:\nInput power fluctuations or poor power quality\nBattery failure or degraded battery capacity\nUPS in bypass mode due to an internal fault\nRepair Action:\nTest the incoming voltage using a multimeter to ensure it’s within the UPS input range.\nCheck the battery voltage; if it\\'s low, consider replacing the battery.\nCheck if the UPS is in bypass mode and reset it if necessary.\nUPS Not Charging the Battery\n\nPossible Causes:\nFaulty charger circuit\nBad battery connections or corroded terminals\nDefective charging board\nRepair Action:\nInspect battery terminals for corrosion and clean them.\nTest the charging voltage and check for proper charging circuit operation.\nIf the charger board is defective, it may need to be replaced.\nOverheating and Shutdown\n\nPossible Causes:\nOverloaded UPS (too many devices connected)\nPoor ventilation or blocked air vents\nFaulty cooling fan\nRepair Action:\nDisconnect unnecessary devices and reduce the load.\nEnsure the UPS has proper ventilation and airflow around it.\nCheck the fan for functionality; replace if faulty.\nUPS Producing Beeping Sound\n\nPossible Causes:\nLow battery\nOverload condition\nInternal fault or failure of components\nRepair Action:\nReplace or recharge the battery if it’s low.\nDisconnect some load if the UPS is overloaded.\nIf the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.).\nOutput Voltage Issues (Distorted or Incorrect Voltage)\n\nPossible Causes:\nFaulty inverter or rectifier circuit\nProblem with the output transformer\nFaulty output relay or PCB\nRepair Action:\nMeasure the output voltage and compare it with the rated output.\nInspect the inverter and rectifier circuits for any faults or blown components.\nCheck the PCB for signs of damage or burnt components.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 168,
"imageuri": "https://bizimages.withfloats.com/actual/28e96b99b645455c873c3014961a11b6.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/28e96b99b645455c873c3014961a11b6.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-07T05:43:52.98Z",
"updatedon": "2024-11-07T05:43:52.98Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-2kva-ups-repair-in-milakpur-goojar-bhiwadi/168",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "2kva ups repair",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "6729bcad4e064873caebfb13",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Amaron Quanta 12V 9Ah battery In Khori 4 Bawal",
"description": "The Amaron Quanta 12V 9Ah battery is a type of lead-acid battery commonly used in various applications such as uninterruptible power supplies (UPS), electric vehicles, and other equipment requiring reliable power storage. Here are some key details about the Amaron Quanta 12V 9Ah battery:\nSpecifications:\nVoltage: 12 volts\nCapacity: 9 ampere-hours (Ah)\nType: Lead-acid battery (typically VRLA - Valve Regulated Lead Acid)\nDimensions: Varies by manufacturer, but generally around 151mm x 65mm x 94mm (L x W x H)\nWeight: Approximately 3.5 to 4 kg, depending on the specific model and manufacturer.\nTerminal Type: Usually comes with F1 or F2 terminals.\nOperating Temperature Range: Typically between -15°C to +50°C.\nCycle Life: Generally rated for about 300-500 cycles depending on depth of discharge and usage conditions.\nFeatures:\nMaintenance-Free: Designed to be maintenance-free, meaning no need for regular water topping.\nLeak-Proof Design: The VRLA design prevents leakage, making it safer for various applications.\nHigh Discharge Rate: Capable of delivering high currents for short periods, which is beneficial for applications requiring burst power.\nDeep Cycle Capability: Suitable for deep cycle applications, allowing for a deeper discharge without damaging the battery.\nDurability: Built to withstand harsh conditions and high temperatures, making it suitable for outdoor use.\nApplications:\nUninterruptible Power Supplies (UPS): Provides backup power during outages.\nElectric Vehicles (EVs): Used in scooters, bikes, and other electric vehicles.\nSolar Energy Storage: Can be used in solar energy systems for storing power.\nEmergency Lighting: Powers emergency lighting systems.\nTelecommunications: Used in communication equipment for backup power.\nMaintenance Tips:\nRegular Inspection: Check for any signs of corrosion on terminals and ensure connections are tight.\nProper Charging: Use a compatible charger and avoid overcharging to prolong battery life.\nStorage: Store in a cool, dry place and maintain a charge if not in use for extended periods.\nSafety Precautions:\nAvoid Short Circuits: Ensure terminals do not come into contact with conductive materials.\nHandle with Care: Batteries can be heavy; handle them carefully to avoid injury.\nDispose Properly: Follow local regulations for battery disposal or recycling.\nFor the most accurate and specific details, always refer to the manufacturer\\'s datasheet or user manual, as specifications may vary slightly between different production batches or models.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"9 ampere",
"Cycle Life",
"outdoor use",
"VRLA design",
"user manual",
"3.5 to 4 kg",
"key details",
"burst power",
"F2 terminals",
"backup power",
"battery life",
"Terminal Type",
"short periods",
"high currents",
"Short Circuits",
"300-500 cycles",
"specific model",
"Proper Charging",
"other equipment",
"cool, dry place",
"specific details",
"extended periods",
"Maintenance Tips",
"harsh conditions",
"deeper discharge",
"usage conditions",
"battery disposal",
"local regulations",
"Leak-Proof Design",
"12 volts Capacity",
"high temperatures",
"lead-acid battery",
"Safety Precautions",
"compatible charger",
"Regular Inspection",
"High Discharge Rate",
"various applications",
"conductive materials",
"Solar Energy Storage",
"solar energy systems",
"regular water topping",
"Deep Cycle Capability",
"reliable power storage",
"communication equipment",
"other electric vehicles",
"deep cycle applications",
"Valve Regulated Lead Acid",
"emergency lighting systems",
"Operating Temperature Range",
"different production batches",
"uninterruptible power supplies",
"The Amaron Quanta 12V 9Ah battery"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 141,
"imageuri": "https://bizimages.withfloats.com/actual/a26c708dc8a848668d748b2e1beec37a.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/a26c708dc8a848668d748b2e1beec37a.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-05T06:35:25.166Z",
"updatedon": "2024-11-05T06:35:25.166Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-9ah-battery-in-khori-4-bawal/141",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "battery",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}