Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "672b14146459a175e6d684a4",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "VERTIV 10 KVA UPS IN DELHI",
"description": "The Vertiv™ Liebert® GXE 6000-10000VA UPS is part of the Liebert GXE Series, which provides line-interactive power protection with advanced features, making it an ideal solution for small and medium-sized businesses, IT infrastructure, and critical equipment in need of reliable power backup. The Liebert GXE UPS offers features like Automatic Voltage Regulation (AVR), extended battery support, efficient performance, and compact design.\n\nHere are all the key details and specifications for the Vertiv™ Liebert® GXE 6000-10000VA UPS:\n\nVertiv Liebert GXE 10000VA UPS (10kVA)\nPower Rating: 10kVA / 10000VA\nOutput Power: 6000W to 8000W\nInput Voltage: 170V - 280V\nOutput Voltage: 230V ± 10%\nWaveform: Simulated Sinewave (or Pure Sinewave for specific models)\nBattery Type: Sealed Lead-Acid (SLA) / VRLA\nBattery Capacity: Typically 12V, 18Ah or 24Ah (with external battery options)\nCharging Time: 4-6 hours for a full recharge\nBackup Time: 10-40 minutes depending on load and battery configuration\nForm Factor: Tower or Rackmount\nInterfaces: USB/Serial, SNMP (optional)\nAdditional Features: AVR, Smart Battery Management, LCD Display, Overload Protection, Alarms, External Battery Support\n\nKey Features:\n\nTopology:\n\nLine-Interactive – This topology offers good protection and ensures that your equipment receives stable power during fluctuations, such as brownouts or overvoltages, without using battery power unnecessarily.\nPower Rating:\n\n6kVA to 10kVA (6000VA to 10000VA) – Suitable for medium to large-sized IT infrastructure, servers, networking equipment, and other critical applications that need consistent and reliable power.\nOutput Power:\n\n6kVA (6000VA) models typically provide 3600W - 4800W of output power.\n10kVA (10000VA) models provide 6000W - 8000W of output power, depending on the specific model and configuration.\nInput Voltage Range:\n\n170V - 280V (wide input voltage range) – Provides protection from both high and low voltage fluctuations.\nOutput Voltage:\n\n230V ± 10% – Standard output voltage suitable for most business and IT applications.\nWaveform Type:\n\nSimulated Sinewave – In line-interactive mode, the output waveform is simulated sinewave. However, the UPS is designed to handle sensitive loads well.\nAutomatic Voltage Regulation (AVR):\n\nThe Liebert GXE UPS comes with AVR that corrects voltage fluctuations without switching to battery power, reducing battery wear and extending the overall life of the system.\nBattery Type:\n\nSealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries – Commonly used for UPS systems due to their reliability and low maintenance.\nBattery Capacity:\n\n12V batteries, with 18Ah, 24Ah, or higher capacity depending on the model and configuration.\nExtended Battery Support: The UPS can be connected to additional battery packs for longer backup runtimes if needed.\nCharging Time:\n\nTypically, the battery recharge time is around 4-6 hours for a full charge from a discharged state.\nBackup Time (Runtime):\n\nBackup time varies depending on load. For example:\nAt 50% load, the runtime could range from 30 minutes to 1 hour.\nAt full load, the backup time may range from 10-20 minutes, depending on the model and load.\nExternal Battery Packs can extend runtime significantly for longer power outages.\n\nForm Factor:\n\nTower or Rackmount options are available, making the Liebert GXE adaptable for different environments, such as server rooms or small data centers.\nRackmount models are designed for 19-inch racks and are ideal for installations in IT environments.\n\nCooling:\n\nFan-assisted cooling for efficient thermal management.\n\nInterfaces & Monitoring:\n\nUSB/Serial Communication Ports for connection with monitoring and management software.\nSNMP Slot: Provides optional SNMP (Simple Network Management Protocol) support for remote monitoring and management.\nLCD Display: Many models include an LCD screen that shows real-time UPS status, load, battery condition, input/output voltage, and other important information.\n\nSmart Battery Management:\n\nEnsures that the batteries are efficiently charged and maintained, extending the life of the battery bank.\nAdvanced battery diagnostics can help predict failures and improve overall UPS reliability.\n\nOverload Protection:\n\nProvides protection against equipment overload and ensures that the system shuts down or enters bypass mode in the event of a fault condition.\n\nAudible Alarms:\n\nAlarms provide real-time alerts for conditions like battery low, overload, fault conditions, and input/output abnormalities.\n\nGreen Features:\n\nEnergy-Efficient: Offers high energy efficiency to reduce operational costs.\nECO Mode: In certain conditions, the system can operate in ECO mode to provide further energy savings, reducing electricity consumption.\n",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 162,
"imageuri": "https://bizimages.withfloats.com/actual/cb873af2e5c04e7a912c982fbfd74423.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/cb873af2e5c04e7a912c982fbfd74423.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-06T07:00:36.625Z",
"updatedon": "2024-11-06T07:00:36.625Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-10-kva-ups-in-delhi/162",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "10KVA UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67de4bd9042ffb8bd0390aa7",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Powerstack battery Testing ",
"description": "Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition:\n\nSteps to Test Powerstack Batteries:\n1. Visual Inspection\nCheck for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced.\n\nClean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water.\n\n2. Check Battery Voltage\nMeasure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts.\n\nFor a 24V battery, you should see a voltage of around 25.2 to 26.0 volts.\n\nUndercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty.\n\n3. Load Testing\nTest under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak.\n\nDC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff.\n\n4. Battery Charge Test\nCharge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size.\n\nMonitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger.\n\nEnd of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery.\n\n5. Conduct a Specific Gravity Test (for Lead-Acid Batteries)\nHydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty.\n\n6. Perform a Battery Health Check (Advanced)\nUse a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs.\n\nInternal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life.\n\n7. Monitor for Temperature\nBatteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system.\n\nSigns of a Failing Battery:\nRapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating.\n\nShort Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life.\n\nInconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery.\n\nPhysical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced.\n\nBattery Maintenance Tips:\nRegular Charging: Avoid deep discharges and always keep the battery charged.\n\nEnvironmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures.\n\nPeriodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly.\n\nUse the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging.\n\nConclusion:\nBattery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 248,
"imageuri": "https://bizimages.withfloats.com/actual/7f2c78a976e246efbe70882f742a421a.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/f8db1555dfa447dbb73d3446e6b45940.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-22T05:34:17.551Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//powerstack-battery-testing-/248",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Powerstack battery Testing ",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d905d2a368d6b4e8edd8af",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "VERTIV UPS",
"description": "The Liebert APM is a modular, scalable, and flexible Uninterruptible Power Supply (UPS) system from Vertiv (formerly Emerson Network Power). It's designed to provide reliable power protection for a wide range of applications, including IT, industrial, healthcare, and telecommunication environments. The Liebert APM series comes in various power ratings, with the range you mentioned being 30 kW - 300 kW, as well as the smaller 1 to 25 kVA units, offering high flexibility for different power requirements.\n\nKey Features of the Liebert APM Series:\nModular Design:\n\nOne of the standout features of the Liebert APM UPS system is its modular design. This allows users to scale the system based on their current needs and future expansion. The modular units can be added incrementally, making it highly adaptable.\nThis modular approach allows for easy maintenance and upgrades without having to replace the entire UPS unit.\nHigh Efficiency:\n\nThe Liebert APM delivers high efficiency, typically achieving up to 95% or more under normal operating conditions. This efficiency helps reduce operational costs and energy consumption.\nIt also features Eco-mode operation, which optimizes energy savings when operating in non-critical situations without compromising protection.\nCompact and Flexible:\n\nDespite its modular nature, the Liebert APM system has a compact design that fits easily into most data centers and industrial setups, where space can often be at a premium.\nIt can be configured for 1-phase or 3-phase power supply, offering flexibility for different types of loads and systems.\nScalable Power:\n\nThe Liebert APM is available in a range from 1 kVA to 300 kVA, which makes it suitable for small server rooms to large data centers.\nThe system allows for easy scalability by adding additional power modules as needed to meet growing demands.\nFlexible Battery Configurations:\n\nThe UPS system supports a variety of battery configurations, allowing for customization based on your runtime requirements. You can select from different battery types, including VRLA (Valve-Regulated Lead-Acid) and lithium-ion batteries.\nAdvanced Monitoring and Management:\n\nLiebert APM comes with Intelligent Monitoring that provides real-time data on the UPS’s performance, such as input/output voltage, battery status, and efficiency.\nIt supports both local and remote monitoring, ensuring that technicians can be alerted to issues before they become critical problems.\nThe system can be integrated with network management systems (NMS) for centralized control across multiple units.\nDual Input Capability:\n\nSome models of the Liebert APM offer dual input power sources, providing redundancy for critical applications. This feature ensures that the system remains operational even if one power input fails.\nFast Response Time:\n\nThe Liebert APM offers a fast transfer time (typically in the milliseconds), ensuring that sensitive equipment is protected even during brief power outages or voltage fluctuations.\nApplications:\nData Centers: Providing reliable, scalable power protection for server rooms and IT infrastructure.\nIndustrial: Protecting critical manufacturing equipment and automated systems from power interruptions.\nHealthcare: Ensuring medical equipment, including imaging devices, lab instruments, and patient monitoring systems, remain operational during power outages.\nTelecommunications: Keeping communication systems up and running to ensure continuous operation of vital network infrastructure.\nBenefits:\nScalability: The ability to scale up or down as required, which is a huge benefit for growing businesses or changing environments.\nReduced Total Cost of Ownership (TCO): With high efficiency and modularity, the Liebert APM reduces energy consumption and minimizes the cost of maintenance.\nReliability: Known for providing excellent protection against power issues, including surges, spikes, and outages.\nCustomization: Supports different configurations and battery options to meet specific needs, offering flexibility across various industries.\nModels & Power Ratings:\nSmall Power Ratings: For smaller environments or edge computing setups, Liebert APM models ranging from 1 kVA to 25 kVA offer robust protection without being overly complex.\nLarge Power Ratings: For larger industrial or data center applications, the 30 kW to 300 kW versions provide scalable power protection to ensure high availability for critical operations.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 239,
"imageuri": "https://bizimages.withfloats.com/actual/930d91046d2046bb95b2598748fed6f3.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/930d91046d2046bb95b2598748fed6f3.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-18T05:34:10.095Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-ups/239",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "VERTIV UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d90098033d2a4a9b171794",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 60 kVA UPS",
"description": "The Vertiv 60 kVA Online UPS is an uninterruptible power supply (UPS) designed to provide reliable and continuous power to critical equipment in case of power interruptions. Here are some key details and features typically associated with this kind of UPS:\n\nKey Features:\nOnline UPS Technology: The Vertiv 60 kVA UPS uses online double-conversion technology, meaning it provides constant, clean, and stable power to connected equipment by continuously converting incoming AC power to DC and then back to AC.\n\nHigh Capacity: With a capacity of 60 kVA (kilo volt-amperes), this UPS is ideal for medium to large-sized businesses or industrial applications that require a significant amount of power protection, such as data centers, manufacturing equipment, or IT infrastructure.\n\nEnergy Efficiency: These systems are typically designed to offer high efficiency, reducing operational costs while maintaining reliable performance. Some models offer \"eco-mode\" functionality to optimize efficiency during non-critical times.\n\nBattery Management: Vertiv UPS units generally feature advanced battery management technology that ensures longer battery life, more efficient charging, and optimal performance. The batteries are usually hot-swappable, allowing for maintenance without shutting down the system.\n\nCompact Design: Despite its high capacity, the Vertiv 60 kVA Online UPS is designed to have a relatively compact form factor, making it easier to integrate into limited spaces in data centers or industrial settings.\n\nCommunication and Monitoring: Many Vertiv UPS systems come equipped with intelligent monitoring systems that allow users to track performance, status, and any faults. This can often be done remotely through a web interface or software.\n\nBypass Capability: Some models offer an internal bypass, which allows the load to continue operating even during maintenance or if the UPS needs to be shut down for any reason.\n\nTypical Applications:\nData Centers: Ensuring that critical server equipment continues running during power interruptions.\nIndustrial Automation: Protecting machinery and control systems from voltage sags or outages.\nHealthcare: Protecting medical equipment that is sensitive to power fluctuations.\nTelecommunications: Ensuring consistent power supply to communication infrastructure.\nAdvantages:\nContinuous Power Protection: Ideal for environments where power outages can cause data loss, downtime, or even equipment damage.\nScalability: Can be paired with additional units or battery banks for higher power requirements.\nReliability: The Vertiv brand is well-regarded in the power protection industry for producing durable and dependable UPS systems.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"typically designed",
"producing durable",
"battery banks",
"additional units",
"voltage sags",
"continue operating",
"models offer",
"web interface",
"limited spaces",
"hotswappable allowing",
"efficient charging",
"significant amount",
"largesized businesses",
"constant clean",
"features typically",
"key details",
"power outages",
"stable power",
"power interruptions",
"continuous power",
"connected equipment",
"critical equipment",
"control systems",
"vertiv brand",
"internal bypass",
"data centers",
"high capacity",
"optimize efficiency",
"industrial applications",
"provide reliable",
"optimal performance",
"power protection",
"vertiv ups systems",
"dependable ups systems",
"intelligent monitoring systems",
"ac high capacity",
"power protection industry",
"maintaining reliable performance",
"equipment damage scalability",
"data loss downtime",
"software bypass capability",
"industrial settings communication",
"infrastructure energy efficiency",
"track performance status",
"system compact design"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 238,
"imageuri": "https://bizimages.withfloats.com/actual/8c2090e09b2a49db9e1f26dfd89e66ad.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/8c2090e09b2a49db9e1f26dfd89e66ad.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-18T05:11:52.413Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-60-kva-ups/238",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Vertiv 60 kVA UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d7f2ab186166ef64e40639",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 10kVA UPS",
"description": "A Vertiv 10kVA UPS (Uninterruptible Power Supply) is a reliable power backup system designed to provide uninterrupted power to critical equipment, such as servers, networking devices, and other sensitive electronic systems. The 10kVA rating indicates that the UPS can handle loads of up to 10,000 volt-amperes, which is typically suitable for medium-sized office setups or small data centers.\n\nVertiv (formerly Emerson Network Power) is known for offering high-quality, efficient, and reliable UPS solutions that help prevent downtime and protect equipment from power surges, outages, and other electrical disturbances.\n\nHere are some key features you might find in a Vertiv 10kVA UPS:\n\nPower Capacity:\n\n10 kVA (or approximately 8 kW for resistive loads), which can support multiple servers or network equipment.\nEfficiency:\n\nMany Vertiv UPS systems are designed with energy efficiency in mind, minimizing energy loss and operating costs.\nBattery Type:\n\nTypically uses either VRLA (Valve Regulated Lead Acid) or Lithium-Ion batteries, providing long-lasting backup time during power interruptions.\nForm Factor:\n\nThese systems may come in both rack-mounted or tower configurations, depending on space requirements.\nScalability:\n\nSome Vertiv UPS units allow for modular expansion, meaning you can add additional units or battery packs to increase power capacity.\nMonitoring and Control:\n\nAdvanced models often come with digital monitoring features, allowing remote monitoring of UPS status, battery health, and power consumption via web interfaces or software.\nSurge Protection and Isolation:\n\nProtects your sensitive equipment from power surges, voltage spikes, and electrical noise.\nMaintenance Bypass:\n\nMany UPS models, including 10kVA versions, have maintenance bypass switches that allow you to service the unit without interrupting power to connected devices.\nVertiv offers various UPS models in this range, so if you’re looking to purchase, it's important to check specifications for exact features, runtime, and compatibility with your equipment.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"10000 voltamperes",
"check specifications",
"10kva versions",
"isolation protects",
"web interfaces",
"battery packs",
"resistive loads",
"approximately 8 kw",
"electrical disturbances",
"protect equipment",
"prevent downtime",
"typically suitable",
"handle loads",
"10kva rating",
"critical equipment",
"sensitive equipment",
"energy efficiency",
"key features",
"interrupting power",
"power consumption",
"ups models",
"network equipment efficiency",
"vertiv ups systems",
"sensitive electronic systems",
"control advanced models",
"vertiv ups units",
"reliable ups solutions",
"exact features runtime",
"power surges outages",
"emerson network power",
"provide uninterrupted power",
"maintenance bypass switches",
"software surge protection",
"add additional units",
"modular expansion meaning",
"space requirements scalability",
"tower configurations depending",
"support multiple servers",
"offering highquality efficient",
"mediumsized office setups",
"servers networking devices"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 233,
"imageuri": "https://bizimages.withfloats.com/actual/6626a89452cd42bd9e741a13bf32b58b.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/6626a89452cd42bd9e741a13bf32b58b.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-17T10:00:11.465Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-10kva-ups/233",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Vertiv 10kVA UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d13de22912ddb97fcecda8",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Maintenance Tips for UPS Systems and Batteries",
"description": "Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips:\n\n1. Regular Inspection\nVisual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion.\nConnections: Ensure that all connections are secure and free from dust and corrosion.\n2. Battery Maintenance\nBattery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load.\nClean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting.\nCheck Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed.\n3. Environmental Considerations\nTemperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly.\nVentilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow.\n4. Regular Testing\nSelf-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature.\nLoad Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage.\n5. Firmware and Software Updates\nKeep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security.\nMonitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues.\n6. Battery Replacement\nFollow Manufacturer Guidelines: Replace batteries according to the manufacturer\\'s recommendations, typically every 3-5 years for lead-acid batteries.\nDispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety.\n7. Load Management\nAvoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life.\nBalanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded.\n8. Documentation\nKeep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance.\n9. Professional Maintenance\nSchedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems.\n10. User Training\nEducate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"35 years",
"maintenance tips",
"ups system",
"ups systems",
"rated capacity",
"distilled water",
"power outage",
"issues encountered",
"records maintain",
"overloaded 8 documentation",
"single outlet",
"receive alerts",
"functioning correctly",
"enclosed spaces",
"baking soda",
"check voltage",
"improve performance",
"ensure terminals",
"load evenly",
"required load",
"battery tester",
"software updates",
"corrosion connections ensure",
"ups monitoring software",
"leadacid batteries dispose",
"battery terminals clean",
"load clean terminals",
"track performance metrics",
"ensuring reliable performance",
"total load connected",
"install firmware updates",
"security monitoring software",
"manufacturers recommendations typically",
"electrolyte levels regularly",
"physical damage leaks"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 221,
"imageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-12T07:55:14.561Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/maintenance-tips-for-ups-systems-and-batteries-/221",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Maintenance Tips for UPS Systems and Batteries",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67ce87255d7710df0e818c94",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv Powerbank",
"description": "The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency.\n\nKey Specifications\nModel: Liebert Powerbank 600\nCapacity: 600 kVA\nInput Voltage: Typically supports 380/400/415 V three-phase systems\nOutput Voltage: Configurable based on system requirements\nForm Factor: Modular design for easy scalability\nEfficiency: High efficiency, often exceeding 95% in double conversion mode\nFeatures\nModular Design:\n\nAllows for easy expansion and maintenance, enabling users to add or replace modules as needed.\nHigh Availability:\n\nDesigned for redundancy and reliability, ensuring continuous power supply to critical loads.\nAdvanced Monitoring:\n\nEquipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking.\nFlexible Configuration:\n\nSupports various configurations to meet specific power requirements and environmental conditions.\nBattery Management:\n\nIntelligent battery management features to optimize battery life and performance.\nScalability:\n\nCan be configured for parallel operation to increase capacity and redundancy.\nCompact Footprint:\n\nDesigned to maximize power density in limited spaces, making it suitable for various installation environments.\nApplications\nData Centers: Provides robust power protection for critical IT infrastructure.\nTelecommunications: Ensures uptime for communication systems.\nIndustrial Applications: Safeguards sensitive equipment in manufacturing and processing environments.\nPerformance Metrics\nInput Frequency: Typically supports 50/60 Hz\nOutput Power Factor: Generally rated at 0.9, allowing for efficient power delivery.\nOperating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius.\nConclusion\nThe Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"09 allowing",
"exceeding 95",
"wide range",
"critical applications",
"local distributor",
"environments ensuring",
"scalability make",
"increase capacity",
"parallel operation",
"performance scalability",
"userfriendly interface",
"replace modules",
"easy expansion",
"data centers",
"power disturbances",
"reliable power protection",
"robust power protection",
"maximize power density",
"official vertiv documentation",
"specific model details",
"efficient ups solution",
"limited spaces making",
"optimize battery life",
"remote monitoring capabilities",
"maintenance enabling users"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 214,
"imageuri": "https://bizimages.withfloats.com/actual/8c7d2d250c934e2cb14a28c2d8c5117f.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/8c7d2d250c934e2cb14a28c2d8c5117f.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-10T06:31:01.833Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-powerbank/214",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Vertiv Powerbank",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "6729bcedeb4a7854cab11753",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Amaron Quanta 12V 12Ah battery In Sector 95 Bhiwadi",
"description": "The Amaron Quanta 12V 12Ah battery is part of Amaron's lineup of high-performance lead-acid batteries, designed for various applications including uninterruptible power supply (UPS) systems, solar energy storage, and other backup power requirements. Here are the key details and specifications of the Amaron Quanta 12V 12Ah battery:\n\n\n1. General Specifications:\nModel: Amaron Quanta 12V 12Ah\nVoltage: 12V (nominal)\nCapacity: 12Ah (Ampere-hours)\nChemistry: Lead-Acid (Flooded or VRLA - Valve Regulated Lead Acid, depending on the specific model variant)\nType: Sealed Lead Acid (SLA) or VRLA (Valve-Regulated Lead Acid)\n2. Dimensions:\nLength: Approximately 151 mm\nWidth: Approximately 65 mm\nHeight: Approximately 94 mm\nWeight: Approximately 3.8 kg (8.38 lbs)\n3. Applications:\nUPS Systems: Ideal for providing backup power to critical systems like computers, telecom equipment, and other sensitive electronics.\nSolar Energy Storage: Can be used in solar applications to store excess energy for later use.\nElectric Vehicles: Sometimes used in smaller electric vehicle or mobility scooter systems.\nAlarm and Security Systems: Provides backup power to alarm systems, CCTV, and other security devices.\nEmergency Lighting: Often used in emergency lighting setups for buildings, factories, and other premises.\n4. Performance Features:\nCycle Life: The Amaron Quanta 12V 12Ah battery generally offers around 300-500 charge/discharge cycles (varies based on usage, charge/discharge depth, and environmental conditions).\nDischarge Current: Able to provide a high discharge current (depending on load), making it suitable for short-term high-power loads.\nRecharge Time: Typically around 6-8 hours for a full recharge from full discharge, but this can vary depending on the charger and charging conditions.\nSelf-Discharge Rate: Low self-discharge rate, meaning it holds charge for a long period when not in use.\n5. Key Features:\nHigh Reliability: Designed for reliable performance, making it a trusted option for various backup power systems.\nSafety: Valve-Regulated Lead-Acid (VRLA) design, meaning it is sealed and maintenance-free under normal operating conditions.\nDurability: Offers robust construction for longer-lasting performance even under challenging environmental conditions.\nLeak-Proof Design: The VRLA design ensures that the battery is leak-resistant, which is particularly important for use in enclosed spaces.\nLow Maintenance: Does not require regular water refilling like traditional flooded lead-acid batteries.\n6. Charging Voltage and Current:\nFloat Voltage: Around 13.5V to 13.8V.\nCharge Voltage (Bulk): Typically around 14.4V to 14.7V (depending on the charger and temperature).\nCharge Current: Around 0.1C to 0.3C (for a 12Ah battery, this translates to a charge current of about 1.2A to 3.6A).\n7. Temperature Range:\nOperating Temperature: Generally from -15°C to 50°C, but the optimal temperature range for performance is usually between 20°C to 25°C.\nStorage Temperature: For best longevity, store the battery at temperatures between 15°C to 25°C.\n8. Warranty:\nWarranty Period: Amaron Quanta batteries typically come with a warranty period of 1-2 years, depending on the region and specific seller's terms.\n9. Advantages:\nCost-Effective: Amaron Quanta batteries are considered affordable yet reliable for various low to medium capacity backup systems.\nWide Availability: These batteries are widely available in many regions and are popular due to their reputation for consistent performance.\nMaintenance-Free: VRLA technology means no need for regular maintenance, unlike flooded batteries.\n10. Safety Considerations:\nVentilation: While sealed, it's important to ensure that the battery is placed in a well-ventilated area to prevent the buildup of gases.\nAvoid Deep Discharge: Like most lead-acid batteries, it is not recommended to discharge the battery below 50% of its total capacity frequently, as this can shorten its lifespan.\nProper Charging: Always use a proper charger designed for lead-acid batteries, as improper charging can lead to overcharging or undercharging, which will reduce battery life.\n11. Comparison with Other Batteries:\nCompared to other 12V 12Ah batteries, the Amaron Quanta typically offers good cycle life, consistent performance, and a strong reputation for reliability. It is one of the more affordable options in its class, which makes it a good choice for cost-conscious consumers looking for backup power.\nConclusion:\nThe Amaron Quanta 12V 12Ah is a reliable and efficient lead-acid battery suitable for a variety of applications, from backup power systems to solar storage. It offers robust performance, minimal maintenance, and a reasonable lifespan with proper care. It's an excellent choice if you're looking for a cost-effective power solution for home or small business applications.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 142,
"imageuri": "https://bizimages.withfloats.com/actual/4c19ae88e25940edb05cece0c6041280.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/4c19ae88e25940edb05cece0c6041280.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-05T06:36:29.122Z",
"updatedon": "2024-11-05T06:36:29.122Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-12ah-battery-in-sector-95-bhiwadi/142",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Battery",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67120454d449d74b99f70970",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Apc Ups Repairing And Maintenance In \tAurangabad Sonipat",
"description": "Repairing and testing an APC UPS (Uninterruptible Power Supply) involves several steps to diagnose issues and ensure the unit functions properly. Here’s a detailed guide on how to approach this:\n\nCommon Issues with APC UPS\nBattery Failure: Most common issue; symptoms include frequent beeping and inability to hold a charge.\nOverload: The UPS may beep continuously if connected devices exceed its capacity.\nFaulty Output: No power output despite being plugged in.\nFirmware Issues: May require updates or resets.\nTools Needed\nMultimeter\nScrewdriver set\nReplacement batteries (if needed)\nLaptop or PC for firmware updates\nDiagnostic software (if applicable)\nTesting Procedure\nVisual Inspection:\n\nCheck for physical damage, burnt components, or loose connections.\nInspect the battery for any signs of swelling or leakage.\nBattery Testing:\n\nDisconnect the UPS from the wall outlet.\nUse a multimeter to measure the battery voltage. Compare it to the rated voltage (e.g., 12V for most lead-acid batteries).\nIf the voltage is significantly lower, consider replacing the battery.\nLoad Testing:\n\nConnect a load tester to the UPS and apply a known load (within the UPS capacity).\nMonitor the output voltage and see if it remains stable under load.\nOutput Testing:\n\nPlug the UPS into the wall and turn it on.\nMeasure the output voltage with a multimeter to ensure it’s delivering the correct voltage (typically around 120V or 230V depending on your region).\nCheck if the UPS switches to battery mode when you disconnect it from the wall.\nOverload Testing:\n\nGradually increase the load on the UPS until it beeps or shuts down.\nVerify that it returns to normal operation once the overload is removed.\nRepair Procedures\nBattery Replacement:\n\nFollow the manufacturer’s guidelines for replacing batteries.\nDispose of old batteries responsibly.\nFirmware Updates:\n\nConnect the UPS to a computer.\nUse APC’s software (like PowerChute) to check for and install firmware updates.\nComponent Repair:\n\nIf internal components (like capacitors or fans) are damaged, soldering skills may be required for repairs or replacements.\nReassembly:\n\nCarefully reassemble the UPS, ensuring all screws are tightened and no wires are pinched.\nFinal Testing\nAfter repairs, conduct a full load test to ensure the UPS operates correctly under stress.\nMonitor for any unusual noises or overheating during operation.\nSafety Precautions\nAlways ensure the UPS is unplugged before performing internal inspections or repairs.\nHandle batteries with care, as they can be hazardous.\nConclusion\nRegular testing and maintenance of your APC UPS can extend its lifespan and ensure reliable performance. If issues persist after self-repair attempts, consider consulting a professional technician or contacting APC support for assistance.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"The UPS",
"wall outlet",
"load tester",
"APC support",
"UPS capacity",
"Load Testing",
"battery mode",
"common issue",
"power output",
"old batteries",
"rated voltage",
"Final Testing",
"Faulty Output",
"several steps",
"output voltage",
"unusual noises",
"Output Testing",
"detailed guide",
"full load test",
"Firmware Issues",
"battery voltage",
"Battery Testing",
"Battery Failure",
"correct voltage",
"Regular testing",
"physical damage",
"Screwdriver set",
"normal operation",
"firmware updates",
"soldering skills",
"Component Repair",
"burnt components",
"frequent beeping",
"Repair Procedures",
"loose connections",
"Visual Inspection",
"Testing Procedure",
"connected devices",
"Apc Ups Repairing",
"Safety Precautions",
"Aurangabad Sonipat",
"Diagnostic software",
"lead-acid batteries",
"Battery Replacement",
"internal components",
"self-repair attempts",
"reliable performance",
"internal inspections",
"Replacement batteries",
"professional technician",
"Uninterruptible Power Supply"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 73,
"imageuri": "https://bizimages.withfloats.com/actual/fe5e65ee545a4e2b8d06898bed2aa8fe.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/fe5e65ee545a4e2b8d06898bed2aa8fe.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-18T06:46:44.811Z",
"updatedon": "2024-10-18T06:46:44.811Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/apc-ups-repairing-and-maintenance-in-aurangabad-sonipat/73",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "Apc Ups Repairing And Maintenance In \tAurangabad Sonipat",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}