Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "6718970e453b0f6645adf709",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 1kva Ups Repair In Alwar Bhiwadi",
"description": "Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems:\n\nRepair Process\nInitial Assessment\n\nGather Information: Document symptoms such as alarms, performance issues, or failure to start.\nVisual Inspection: Look for signs of physical damage, burnt components, or loose connections.\nDiagnosis\n\nSelf-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes.\nMultimeter Testing: Use a multimeter to check voltage levels, current, and resistance.\nBattery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity.\nInspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault.\nCommon Issues\n\nBattery Failure: The most common issue; batteries may need replacement due to age or improper charging.\nCapacitor Issues: Capacitors can degrade over time, leading to performance problems.\nOverheating: Caused by dust accumulation, blocked ventilation, or fan failure.\nControl Board Failures: Issues with the control board can affect functionality.\nInput/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues.\nRepair and Replacement\n\nBattery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity.\nComponent Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics.\nSoldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board.\nFirmware Updates: If applicable, update the firmware for optimal performance.\nTesting After Repair\n\nFunctional Testing: Run the UPS to ensure it operates correctly.\nLoad Testing: Test under load conditions to verify performance and capacity.\nBattery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected.\nFinal Inspection\n\nSafety Checks: Verify that all repairs meet safety standards.\nDocumentation: Record all repairs, parts replaced, and any other relevant information for future reference.\nMaintenance Tips\nRegular Testing: Conduct periodic self-tests and inspections to identify potential issues early.\nBattery Maintenance: Keep battery terminals clean and ensure connections are tight.\nCooling: Ensure proper ventilation around the UPS to prevent overheating.\nEnvironment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures.\nWhen to Seek Professional Help\nIf issues are complex or beyond basic troubleshooting, consult a professional service.\nUse authorized Vertiv service centers for repairs to ensure quality and warranty compliance.\nConclusion\nRepairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 98,
"imageuri": "https://bizimages.withfloats.com/actual/76237a5ae75049919100d38e7c2a2aad.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/76237a5ae75049919100d38e7c2a2aad.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-23T06:26:22.4Z",
"updatedon": "2024-10-23T06:26:22.4Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-1kva-ups-repair-in-alwar-bhiwadi/98",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "UPS Rental & UPS Repairing Service",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "671894f87b19ca400cddba58",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv Ups Repairing In Ardee City Gurgaon",
"description": "Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations:\n\n\nUPS Repair Process\nInitial Assessment\n\nIdentify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms.\nVisual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections.\nDiagnosis\n\nSelf-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues.\nMultimeter Testing: Measure voltage, current, and resistance to identify electrical issues.\nBattery Testing: Check the health of the batteries using a battery tester or multimeter.\nCheck Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning.\nCommon Issues\n\nBattery Failure: Batteries may need replacement due to age or over-discharge.\nCapacitor Issues: Capacitors can fail due to heat or age, leading to performance issues.\nCooling Problems: Blocked fans or insufficient ventilation can cause overheating.\nControl Board Malfunctions: Issues with the control board can affect the UPS's operation.\nInput/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry.\nRepair and Replacement\n\nBattery Replacement: Remove and replace old batteries with new ones of the same specifications.\nComponent Replacement: Replace faulty capacitors, fuses, or other components as diagnosed.\nResoldering Connections: Fix any broken or loose solder joints on the circuit board.\nSoftware/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance.\nTesting After Repair\n\nFunctional Testing: After repairs, perform a complete functional test of the UPS.\nLoad Testing: Test the UPS under load to ensure it can handle the required capacity.\nBattery Cycle Testing: Run the UPS on battery power to check for proper operation.\nFinal Inspection\n\nSafety Check: Ensure all repairs meet safety standards.\nDocumentation: Document the repairs, parts replaced, and any other relevant information for future reference.\nMaintenance Tips\nRegular Testing: Conduct regular self-tests and inspections to catch issues early.\nBattery Maintenance: Check battery connections and terminals periodically; keep them clean and tight.\nEnvironment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan.\nFirmware Updates: Keep the UPS firmware updated for improved performance and security.\nProfessional Repair Services\nWhen to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional.\nAuthorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs.\nConclusion\nRepairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 97,
"imageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-23T06:17:28.889Z",
"updatedon": "2024-10-23T06:17:28.889Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-ups-repairing-in-ardee-city-gurgaon/97",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "UPS Repair",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67de4a9d6f5ecfd85ef84935",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Luminous Ups",
"description": "The Luminous LD30KH-PRO is a high-performance Inverter designed to provide reliable backup power for homes, offices, and small commercial setups. It is a part of Luminous' Pure Sine Wave Inverter series, offering high efficiency and stable power supply to sensitive equipment like computers, refrigerators, air conditioners, and other appliances.\n\nHere are the key features and specifications of the Luminous LD30KH-PRO:\n\nKey Features:\nPower Capacity:\n\n30 kVA (Kilovolt-Ampere) – It is designed to support large power loads, making it suitable for medium to large residential, commercial, or industrial applications.\n\nPure Sine Wave Output:\n\nProvides clean and stable output voltage, ensuring that sensitive equipment (like computers, air conditioners, and medical equipment) operates without issues, such as noise or voltage fluctuations.\n\nHigh Efficiency:\n\nThe inverter operates with high efficiency, which reduces power loss and ensures that more of the battery's energy is used to power connected appliances.\n\nAdvanced Microprocessor Technology:\n\nThe inverter uses a microprocessor-based design to ensure high performance, protection, and reliability. It optimizes charging and discharging cycles, as well as load management.\n\nUser-Friendly LCD Display:\n\nIt comes with an intuitive LCD display that shows important information such as battery status, power usage, input and output voltage, and fault conditions. This helps users easily monitor and manage the system.\n\nWide Input Voltage Range:\n\nThe inverter operates with a wide input voltage range, which helps it perform well under varying input conditions. This feature helps protect connected equipment from power surges and fluctuations.\n\nMultiple Protection Mechanisms:\n\nBuilt-in protection features include overload protection, short-circuit protection, deep discharge protection, and battery reverse polarity protection, which ensures the safety of the connected equipment.\n\nBattery Compatibility:\n\nThe Luminous LD30KH-PRO is compatible with both lead-acid and lithium-ion batteries, giving users flexibility depending on their preferences for battery technology.\n\nSmart Battery Management:\n\nThe inverter comes with intelligent battery management to optimize battery performance, extending their lifespan and ensuring safe charging and discharging cycles.\n\nCompact and Reliable Design:\n\nDesigned with a compact form factor and a durable build, the inverter is ideal for both indoor and outdoor installations and can be used for both backup power and off-grid applications.\n\nApplications:\nResidential Homes – For providing backup power for large appliances like air conditioners, refrigerators, lighting, and electronics.\n\nSmall and Medium Businesses – For ensuring uninterrupted power supply to computers, servers, and other essential equipment.\n\nCommercial Use – Ideal for large offices, small industries, and workshops.\n\nRural/Off-Grid Areas – Can be used in places with frequent power outages or no access to the grid, providing a reliable power solution.\n\nSpecifications Summary:\nRated Capacity: 30 kVA\n\nOutput Type: Pure Sine Wave\n\nInput Voltage: 120V – 300V (depending on model)\n\nCharging Current: Adjustable (depends on load)\n\nDisplay: LCD with detailed status updates\n\nBattery Compatibility: Compatible with lead-acid and lithium-ion batteries",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"medium businesses",
"lithiumion batteries",
"large appliances",
"outdoor installations",
"durable build",
"luminous ld30khpro",
"output voltage",
"batterys energy",
"high efficiency",
"inverter operates",
"key features",
"homes offices",
"grid providing",
"computers servers",
"electronics small",
"fault conditions",
"optimizes charging",
"microprocessorbased design",
"sensitive equipment",
"power surges",
"discharging cycles",
"backup power",
"highperformance inverter designed",
"providing backup power",
"reliable design designed",
"medical equipment operates",
"discharging cycles compact",
"essential equipment commercial",
"ensuring safe charging",
"varying input conditions",
"computers air conditioners",
"large residential commercial",
"small commercial setups",
"frequent power outages",
"reduces power loss",
"stable power supply",
"load display lcd",
"workshops ruraloffgrid areas",
"compact form factor",
"intelligent battery management",
"shows important information",
"intuitive lcd display"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 247,
"imageuri": "https://bizimages.withfloats.com/actual/adfcf6a1a7214424b3baeaee446d5f26.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/4b5ca6e9e3154e0992e899bf9f0a3730.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-22T05:29:01.515Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/luminous-ups/247",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Luminous Ups",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67de48f5884d97a2c7d83fde",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "APC 6000VA UPS",
"description": "The APC Smart-UPS RT 6000VA is a high-performance uninterruptible power supply (UPS) designed to provide reliable power protection for critical equipment in various settings such as data centers, server rooms, and industrial environments. Here are some key features and specifications:\n\nKey Features:\nPower Capacity:\n\n6000VA / 4800W – Suitable for medium-to-large systems that need substantial power backup.\n\nRack-Mountable Design:\n\nThe UPS can be mounted in a 19-inch rack, making it ideal for environments that require a space-efficient solution.\n\nExtended Runtime:\n\nIt provides sufficient runtime to safely shut down connected equipment or continue operations during short power outages, depending on the load.\n\nPure Sine Wave Output:\n\nEnsures high-quality power to sensitive equipment, avoiding power disturbances such as harmonic distortion or voltage spikes.\n\nHot-Swappable Batteries:\n\nAllows for maintenance without powering down the UPS, increasing uptime and operational efficiency.\n\nLCD Display:\n\nA user-friendly LCD display provides detailed information about the UPS status, including input/output voltage, battery charge, and runtime.\n\nExtended Battery Options:\n\nCan be connected to external battery packs for increased runtime in case of prolonged power outages.\n\nAdvanced Communication Features:\n\nOffers a variety of communication options such as USB, RS-232, or SNMP for monitoring and management. It’s compatible with APC’s PowerChute management software.\n\nEnvironmental Monitoring:\n\nSome models include environmental sensors to monitor conditions like temperature and humidity, ensuring the UPS operates in optimal conditions.\n\nSafety Features:\n\nIt includes features such as overload protection, short-circuit protection, and battery optimization to ensure safe and efficient operation.\n\nIdeal Use Cases:\nData Centers\n\nServer Rooms\n\nNetwork Equipment\n\nIndustrial and Medical Equipment",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"connected equipment",
"industrial environments",
"medical equipment",
"ensure safe",
"includes features",
"ups operates",
"humidity ensuring",
"monitor conditions",
"environmental sensors",
"usb rs232",
"communication options",
"increased runtime",
"ups status",
"detailed information",
"harmonic distortion",
"continue operations",
"safely shut",
"sufficient runtime",
"mediumtolarge systems",
"key features",
"critical equipment",
"battery optimization",
"efficient operation ideal",
"ups increasing uptime",
"external battery packs",
"userfriendly lcd display",
"19inch rack making"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 246,
"imageuri": "https://bizimages.withfloats.com/actual/d3995dfe98b248638324f64ea6764951.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/e51da57572c347c2a60cd3afc5989bcd.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-22T05:21:57.201Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/apc-6000va-ups/246",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "APC 6000VA UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d5328fdb7fc0f04f83af80",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Battery Replacement In Faridabad",
"description": "Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each.\n\nTypes of Batteries and Their Replacement Process\n1. Lead-Acid Batteries\nCommon Types:\nFlooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells.\nSealed Lead-Acid (SLA): Maintenance-free and does not require water addition.\nAbsorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats.\nGel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications.\nReplacement Process:\nTurn off the system: Ensure the system is powered off, and disconnect it from the grid or load.\nSafety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases.\nDisconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal.\nRemove old batteries: Lift and remove the batteries carefully, especially if they're heavy.\nClean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water.\nInstall new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system and check the voltage and charging status.\nMaintenance Tips:\nRegularly check the electrolyte levels in flooded batteries.\nClean terminals and ensure the battery box or tray is secure.\n2. Lithium-Ion Batteries\nCommon Types:\nLithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan.\nLithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools.\nLithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications.\nLithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones.\nReplacement Process:\nTurn off the system: Disconnect the power source or system.\nSafety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage.\nDisconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal.\nRemove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries.\nInstall the new battery: Place the new battery in the same orientation and secure it.\nReconnect terminals: Attach the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly.\nMaintenance Tips:\nLithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range.\nBattery Management System (BMS) should be monitored to ensure proper functioning and safety.\n\nConclusion:\nBattery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation.\n\nLead-acid batteries need regular maintenance, especially flooded types.\nLithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance.\nAlways follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"system disconnect",
"common types",
"system ensure",
"replacement process",
"battery place",
"battery box",
"electrolyte levels",
"gel electrolyte",
"sla battery",
"battery replacement",
"system power",
"handling batteries",
"longer lifespan",
"batterys charging",
"typically lighter",
"handled carefully",
"generally safe",
"small devices",
"highpower applications",
"high efficiency",
"evs due",
"batteries place",
"baking soda",
"batteries carefully",
"batteries lift",
"sulfuric acid",
"ill provide",
"vary depending",
"batterypowered devices",
"faridabadbattery replacement",
"minimal maintenance",
"regular maintenance",
"power source",
"leadacid batteries",
"power systems",
"solar systems",
"positive terminal",
"water install",
"negative terminal",
"battery lithiumion batteries",
"leadacid batteries install",
"reconnect terminals attach",
"positive terminal remove",
"solar systems leadacid",
"evs power tools",
"negative terminal check",
"common maintenance task",
"installation leadacid batteries",
"ensure proper recycling",
"ensure proper functioning",
"drones power banks",
"adding distilled water",
"avoid environmental hazards",
"follow safety guidelines",
"requiring specific attention",
"avoid overheating shortcircuiting"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 231,
"imageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-15T07:55:59.544Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/battery-replacement-in-faridabad/231",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Battery Replacement In Faridabad",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "672c53984c2d7366708cbc86",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 2kva Ups Repair In Milakpur Goojar Bhiwadi",
"description": "Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations.\n\nWhen a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair:\n\nCommon Problems in Vertiv 2kVA UPS\nUPS Not Turning On\n\nPossible Causes:\nFaulty battery or dead battery\nBlown fuse or circuit breaker\nPower supply input issue (fuse or switch)\nRepair Action:\nCheck and replace the battery if necessary.\nInspect the fuse or circuit breaker and replace if blown.\nVerify the input power connections.\nFrequent Switching to Battery Mode\n\nPossible Causes:\nInput power fluctuations or poor power quality\nBattery failure or degraded battery capacity\nUPS in bypass mode due to an internal fault\nRepair Action:\nTest the incoming voltage using a multimeter to ensure it’s within the UPS input range.\nCheck the battery voltage; if it\\'s low, consider replacing the battery.\nCheck if the UPS is in bypass mode and reset it if necessary.\nUPS Not Charging the Battery\n\nPossible Causes:\nFaulty charger circuit\nBad battery connections or corroded terminals\nDefective charging board\nRepair Action:\nInspect battery terminals for corrosion and clean them.\nTest the charging voltage and check for proper charging circuit operation.\nIf the charger board is defective, it may need to be replaced.\nOverheating and Shutdown\n\nPossible Causes:\nOverloaded UPS (too many devices connected)\nPoor ventilation or blocked air vents\nFaulty cooling fan\nRepair Action:\nDisconnect unnecessary devices and reduce the load.\nEnsure the UPS has proper ventilation and airflow around it.\nCheck the fan for functionality; replace if faulty.\nUPS Producing Beeping Sound\n\nPossible Causes:\nLow battery\nOverload condition\nInternal fault or failure of components\nRepair Action:\nReplace or recharge the battery if it’s low.\nDisconnect some load if the UPS is overloaded.\nIf the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.).\nOutput Voltage Issues (Distorted or Incorrect Voltage)\n\nPossible Causes:\nFaulty inverter or rectifier circuit\nProblem with the output transformer\nFaulty output relay or PCB\nRepair Action:\nMeasure the output voltage and compare it with the rated output.\nInspect the inverter and rectifier circuits for any faults or blown components.\nCheck the PCB for signs of damage or burnt components.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 168,
"imageuri": "https://bizimages.withfloats.com/actual/28e96b99b645455c873c3014961a11b6.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/28e96b99b645455c873c3014961a11b6.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-07T05:43:52.98Z",
"updatedon": "2024-11-07T05:43:52.98Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-2kva-ups-repair-in-milakpur-goojar-bhiwadi/168",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "2kva ups repair",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "672c50fa042b75a9a76220f5",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Luminous 4Kva Ups In Aram Nagar Bawal",
"description": "The Luminous Cruze+ 4kVA is a high-performance online UPS that provides uninterrupted power for residential, commercial, and IT applications. Being an online UPS, it offers continuous, stable power with zero transfer time, making it ideal for sensitive equipment such as computers, servers, medical devices, and industrial systems.\nKey Features of Luminous Cruze+ 4kVA UPS\nOnline Double-Conversion Technology:\n\nThe Cruze+ 4kVA uses true online double-conversion technology, which ensures that your devices get clean, continuous, and regulated power without interruptions. In case of any fluctuations in the input voltage, the UPS immediately corrects it and ensures stable output voltage.\nPure Sine Wave Output:\n\nThe UPS provides pure sine wave output, which is ideal for sensitive devices, as it ensures minimal distortion and avoids any damage to electronic equipment, unlike square wave UPS systems that can harm certain types of equipment.\nHigh Efficiency:\n\nWith a high conversion efficiency, the Cruze+ 4kVA reduces energy consumption and operational costs. This makes it not only a reliable backup solution but also energy-efficient.\nWide Input Voltage Range:\n\nThe Cruze+ UPS is designed to handle a wide input voltage range, which ensures that the system performs well even in areas with frequent voltage fluctuations, thereby reducing wear and tear on both the UPS and connected devices.\nLong Battery Life:\n\nEquipped with advanced battery management features, this UPS helps in optimizing the battery life, offering extended service periods even with frequent use.\nLCD/LED Display:\n\nThe LCD display shows real-time status of the UPS, including input/output voltage, battery charge status, load percentage, and any faults. The LED indicators make it easier to monitor and understand the operational status at a glance.\nBattery Charging:\n\nThe Cruze+ 4kVA UPS can handle multiple battery types, including lead-acid and VRLA batteries. It is equipped with an intelligent charging system that ensures batteries are charged efficiently without overcharging.\nOverload and Short Circuit Protection:\n\nProvides overload protection and short-circuit protection, ensuring that the system is safe from potential damage during power surges or faults.\nBattery Bank Options:\n\nThe Cruze+ 4kVA is typically paired with a separate battery bank that provides the backup power. This can include Exide tubular batteries or Luminous batteries for optimal performance.\nApplications\nResidential: For powering sensitive equipment like computers, medical devices, and other electronics.\nCommercial: Protects servers, networking equipment, and office devices.\nIndustrial: Suitable for critical industrial machines, automation systems, and control panels.\nTechnical Specifications\nCapacity: 4kVA (4000 VA)\nInput Voltage: 140V - 300V (Wide input voltage range)\nOutput Voltage: 220V / 230V (Pure sine wave)\nOutput Frequency: 50 Hz ± 0.2 Hz\nBattery Charging Current: Adjustable (Typically 5-10A)\nBattery Type: Compatible with VRLA, Lead-Acid, and Tubular Batteries\nBackup Time: Depends on the battery capacity (typically, it can provide backup for 2-4 hours depending on the load and battery bank size).\nDimensions (LxWxH): 465mm x 310mm x 115mm\nWeight: Around 15-18 kg (excluding battery)\nWarranty: 2 years on the UPS (can vary based on the model or region)",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 167,
"imageuri": "https://bizimages.withfloats.com/actual/40af0b586b86480e81ad3bcdb1e059e3.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/40af0b586b86480e81ad3bcdb1e059e3.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-07T05:32:42.172Z",
"updatedon": "2024-11-07T05:32:42.172Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/luminous-4kva-ups-in-aram-nagar-bawal/167",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "4 kva ups",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "672b169c155daa1d35aaea95",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "VERTIV 20KVA UPS IN GURGAON",
"description": "The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount).\nHere\\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS:\n\nKey Features of the Vertiv Liebert GXT5-20KMVRT11UXLN:\n\n1. Power Rating and Capacity:\nPower Rating: 20kVA / 20000VA\nOutput Power: 16000W (16kW) at 208V (depending on load conditions)\nThis provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure.\n\n2. Voltage Configuration:\nInput Voltage: 208V (for 3-phase input)\nThe GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements.\n\n3. Topology:\nOn-Line Double-Conversion:\nThe GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection.\nThis topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances.\nZero transfer time from utility power to battery power ensures no downtime for connected equipment.\n\n4. Waveform Type:\nPure Sinewave Output:\nThe UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference.\n\n5. Battery Type and Runtime:\nBattery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems.\nExternal Battery Support:\nThe Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications.\nCharging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity.\n\n6. Runtime (Backup Time):\nThe battery backup time will vary depending on the load. Here are some estimates:\nAt 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes.\nAt full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity.\nExtended runtime can be achieved with additional external battery cabinets.\n\n7. Cooling:\nFan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures.\n\n8. Form Factor:\nRackmount and Tower:\nThe Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS.\nRackmount form factor: 3U (for the rack version), designed for 19-inch rack installations.\nThe rackmount option allows easy integration into standard server racks or data center environments.\n\n9. Energy Efficiency and Certifications:\nEnergy Star Certification:\nThe Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation.\nIt also has low total cost of ownership (TCO), thanks to its energy-efficient operation.\nHigh Efficiency Mode (Eco Mode):\nThe UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit.\n\n10. Interfaces and Monitoring:\nLCD Display:\nThe UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status.\n\nConnectivity:\nUSB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring.\nSNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network.\nDry Contact Interface: Available for integration with building management or alert systems.\n\n11. Advanced Features:\nAutomatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity.\n\nOverload and Short-Circuit Protection:\n\nProtects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms.\nSmart Battery Management:\n\nThe system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures.\nAudible Alarms:\n\nProvides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"120V AC",
"The UPS",
"50% load",
"Eco Mode",
"full load",
"4-6 hours",
"SNMP Slot",
"load levels",
"LCD Display",
"input power",
"90% capacity",
"optional ATS",
"alarm status",
"5-10 minutes",
"Key Features",
"Power Rating",
"rack version",
"server rooms",
"data centers",
"battery bank",
"Battery Type",
"power failure",
"rackmount UPS",
"short circuit",
"Waveform Type",
"highest level",
"3-phase input",
"Input Voltage",
"UPS condition",
"Network Ports",
"alert systems",
"Charging Time",
"utility power",
"battery power",
"Line) topology",
"Audible Alarms",
"key parameters",
"longer periods",
"battery charge",
"low total cost",
"load conditions",
"charging cycles",
"flexible design",
"different types",
"telecom systems",
"sensitive loads",
"IT environments",
"The GXT5 series",
"Extended runtime",
"easy integration",
"network switches",
"rackmount option",
"battery capacity",
"15 to 25 minutes",
"Sealed Lead-Acid",
"local management",
"VERTIV 20KVA UPS",
"remote monitoring",
"normal conditions",
"Advanced Features",
"robust protection",
"high availability",
"Energy Efficiency",
"potential failures",
"little maintenance",
"detailed breakdown",
"critical equipment",
"battery monitoring",
"energy consumption",
"power disturbances",
"power requirements",
"optional SNMP card",
"Zero transfer time",
"connected equipment",
"automatic switching",
"building management",
"battery backup time",
"other system faults",
"Liebert GXT5 series",
"Fan-assisted cooling",
"input/output voltage",
"High Efficiency Mode",
"20000VA Output Power",
"Voltage Configuration",
"real-time information",
"Rackmount form factor",
"low battery, overload",
"high-density IT loads",
"standard server racks",
"Dry Contact Interface",
"Line Double-Conversion",
"The GXT5-20KMVRT11UXLN",
"sensitive IT equipment",
"external battery packs",
"critical infrastructure",
"flexible configurations",
"Short-Circuit Protection",
"data center environments",
"Smart Battery Management",
"External Battery Support",
"high-efficiency operation",
"high-efficiency standards",
"Energy Star Certification",
"seamless power continuity",
"Automatic Transfer Switch",
"energy-efficient operation",
"serial communication ports",
"19-inch rack installations",
"Battery health diagnostics",
"efficient energy management",
"higher ambient temperatures",
"clean, pure sinewave output",
"high-performance UPS systems",
"mission-critical applications",
"optimal temperature management",
"20kVA (20000VA) rack/tower UPS",
"Valve-Regulated Lead-Acid) batteries",
"The Liebert GXT5-20KMVRT11UXLN model",
"additional external battery cabinets",
"Vertiv Liebert GXT5-20KMVRT11UXLN UPS",
"The Vertiv Liebert GXT5-20KMVRT11UXLN",
"high-performance, reliable power protection"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 163,
"imageuri": "https://bizimages.withfloats.com/actual/86255b3534174e95852f2e98910612d7.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/86255b3534174e95852f2e98910612d7.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-06T07:11:24.367Z",
"updatedon": "2024-11-06T07:11:24.367Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-20kva-ups-in-gurgaon/163",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "20 KVA UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "6720980b2b5881cbadcda4e8",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Repairing And Maintaining UPS In Delhi",
"description": "Repairing And Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring the reliability and longevity of the power backup system. Here’s a detailed overview of UPS battery maintenance and repair practices.\n\nUPS Battery Types\nLead-Acid Batteries:\n\nValve-Regulated Lead Acid (VRLA): Maintenance-free and sealed, suitable for most UPS systems.\nFlooded Lead Acid: Requires periodic maintenance and water topping.\nLithium-Ion Batteries:\n\nIncreasingly used due to longer life and higher efficiency but may require specific handling protocols.\nMaintenance Practices\nRegular Inspections:\n\nVisual Check: Inspect batteries for physical damage, corrosion, or leaks. Look for swelling or bulging in case of lead-acid batteries.\nConnections: Ensure all terminals and connections are tight and free of corrosion.\nCleaning:\n\nClean battery terminals with a mixture of baking soda and water to remove corrosion. Rinse with clean water and dry thoroughly.\nBattery Testing:\n\nVoltage Checks: Regularly measure the voltage of each battery to identify weak cells.\nLoad Testing: Perform load tests to ensure the battery can deliver the expected capacity under load conditions.\nTemperature Monitoring:\n\nMonitor battery temperature, especially in environments with high heat, as excessive temperatures can affect battery performance and lifespan.\nElectrolyte Level (for Flooded Batteries):\n\nCheck and maintain the electrolyte levels in flooded lead-acid batteries. Top up with distilled water as necessary.\nBattery Health Monitoring:\n\nUse battery management systems (BMS) for advanced monitoring of battery health, state of charge, and state of health.\nRepair Practices\nIdentifying Faults:\n\nCommon issues include short-circuited cells, sulfation, and capacity loss. Use diagnostic tools to identify problems.\nReplacing Individual Batteries:\n\nIf a battery within a pack fails, replace only the faulty battery if it’s compatible. However, it's often recommended to replace all batteries in a series to ensure uniform performance.\nEqualization Charging (for Flooded Batteries):\n\nPeriodically perform equalization charging to balance the charge across all cells and prevent sulfation.\nReconditioning:\n\nSome lead-acid batteries can be reconditioned through a process of controlled charging and discharging to restore capacity. This is not always successful and should be done by professionals.\nBattery Replacement:\n\nWhen batteries reach the end of their lifespan (typically 3-5 years for lead-acid), replace them with new ones. Ensure that replacements meet the manufacturer's specifications.\nBest Practices for Maintenance\nDocumentation:\n\nKeep records of inspections, tests, and replacements to track battery performance over time.\nEnvironmental Conditions:\n\nMaintain an optimal environment for batteries—ideally, a cool, dry place free from excessive humidity and temperature fluctuations.\nProfessional Servicing:\n\nConsider engaging professionals for complex repairs or maintenance tasks, especially for large or critical UPS systems.\nTraining:\n\nTrain personnel on proper handling, maintenance, and safety procedures related to UPS batteries.\nConclusion\nRegular maintenance and timely repairs of UPS batteries are essential for ensuring the reliability of power backup systems. By implementing best practices, monitoring battery health, and addressing issues promptly, you can prolong the life of your UPS batteries and enhance overall system performance. If you have specific questions or need further details on any aspect, feel free to ask!",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"3-5 years",
"high heat",
"load tests",
"weak cells",
"longer life",
"baking soda",
"clean water",
"Load Testing",
"Visual Check",
"Common issues",
"capacity loss",
"water topping",
"UPS batteries",
"Voltage Checks",
"timely repairs",
"Best Practices",
"faulty battery",
"Delhi Repairing",
"distilled water",
"complex repairs",
"load conditions",
"physical damage",
"Battery Testing",
"Maintaining UPS",
"cool, dry place",
"diagnostic tools",
"repair practices",
"most UPS systems",
"expected capacity",
"safety procedures",
"maintenance tasks",
"Electrolyte Level",
"higher efficiency",
"detailed overview",
"Flooded Batteries",
"UPS Battery Types",
"Flooded Lead Acid",
"excessive humidity",
"specific questions",
"Lead-Acid Batteries",
"Regular Inspections",
"Regular maintenance",
"optimal environment",
"Battery Replacement",
"battery temperature",
"uniform performance",
"advanced monitoring",
"battery performance",
"power backup system",
"Individual Batteries",
"periodic maintenance",
"critical UPS systems",
"Equalization Charging",
"short-circuited cells",
"Lithium-Ion Batteries",
"Maintenance Practices",
"Professional Servicing",
"excessive temperatures",
"Temperature Monitoring",
"UPS battery maintenance",
"Clean battery terminals",
"temperature fluctuations",
"Environmental Conditions",
"Maintenance Documentation",
"Battery Health Monitoring",
"Valve-Regulated Lead Acid",
"battery management systems",
"overall system performance",
"specific handling protocols",
"Uninterruptible Power Supply"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 131,
"imageuri": "https://bizimages.withfloats.com/actual/1c0f13c6e9d34936ad199dbe084446a5.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/1c0f13c6e9d34936ad199dbe084446a5.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-29T08:08:43.949Z",
"updatedon": "2024-10-29T08:08:43.949Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/repairing-and-maintaining-ups-in-delhi/131",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Repairing And Maintaining UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}