Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "672c53984c2d7366708cbc86",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 2kva Ups Repair In Milakpur Goojar Bhiwadi",
"description": "Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations.\n\nWhen a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair:\n\nCommon Problems in Vertiv 2kVA UPS\nUPS Not Turning On\n\nPossible Causes:\nFaulty battery or dead battery\nBlown fuse or circuit breaker\nPower supply input issue (fuse or switch)\nRepair Action:\nCheck and replace the battery if necessary.\nInspect the fuse or circuit breaker and replace if blown.\nVerify the input power connections.\nFrequent Switching to Battery Mode\n\nPossible Causes:\nInput power fluctuations or poor power quality\nBattery failure or degraded battery capacity\nUPS in bypass mode due to an internal fault\nRepair Action:\nTest the incoming voltage using a multimeter to ensure it’s within the UPS input range.\nCheck the battery voltage; if it\\'s low, consider replacing the battery.\nCheck if the UPS is in bypass mode and reset it if necessary.\nUPS Not Charging the Battery\n\nPossible Causes:\nFaulty charger circuit\nBad battery connections or corroded terminals\nDefective charging board\nRepair Action:\nInspect battery terminals for corrosion and clean them.\nTest the charging voltage and check for proper charging circuit operation.\nIf the charger board is defective, it may need to be replaced.\nOverheating and Shutdown\n\nPossible Causes:\nOverloaded UPS (too many devices connected)\nPoor ventilation or blocked air vents\nFaulty cooling fan\nRepair Action:\nDisconnect unnecessary devices and reduce the load.\nEnsure the UPS has proper ventilation and airflow around it.\nCheck the fan for functionality; replace if faulty.\nUPS Producing Beeping Sound\n\nPossible Causes:\nLow battery\nOverload condition\nInternal fault or failure of components\nRepair Action:\nReplace or recharge the battery if it’s low.\nDisconnect some load if the UPS is overloaded.\nIf the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.).\nOutput Voltage Issues (Distorted or Incorrect Voltage)\n\nPossible Causes:\nFaulty inverter or rectifier circuit\nProblem with the output transformer\nFaulty output relay or PCB\nRepair Action:\nMeasure the output voltage and compare it with the rated output.\nInspect the inverter and rectifier circuits for any faults or blown components.\nCheck the PCB for signs of damage or burnt components.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 168,
"imageuri": "https://bizimages.withfloats.com/actual/28e96b99b645455c873c3014961a11b6.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/28e96b99b645455c873c3014961a11b6.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-07T05:43:52.98Z",
"updatedon": "2024-11-07T05:43:52.98Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-2kva-ups-repair-in-milakpur-goojar-bhiwadi/168",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "2kva ups repair",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "6718970e453b0f6645adf709",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 1kva Ups Repair In Alwar Bhiwadi",
"description": "Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems:\n\nRepair Process\nInitial Assessment\n\nGather Information: Document symptoms such as alarms, performance issues, or failure to start.\nVisual Inspection: Look for signs of physical damage, burnt components, or loose connections.\nDiagnosis\n\nSelf-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes.\nMultimeter Testing: Use a multimeter to check voltage levels, current, and resistance.\nBattery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity.\nInspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault.\nCommon Issues\n\nBattery Failure: The most common issue; batteries may need replacement due to age or improper charging.\nCapacitor Issues: Capacitors can degrade over time, leading to performance problems.\nOverheating: Caused by dust accumulation, blocked ventilation, or fan failure.\nControl Board Failures: Issues with the control board can affect functionality.\nInput/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues.\nRepair and Replacement\n\nBattery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity.\nComponent Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics.\nSoldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board.\nFirmware Updates: If applicable, update the firmware for optimal performance.\nTesting After Repair\n\nFunctional Testing: Run the UPS to ensure it operates correctly.\nLoad Testing: Test under load conditions to verify performance and capacity.\nBattery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected.\nFinal Inspection\n\nSafety Checks: Verify that all repairs meet safety standards.\nDocumentation: Record all repairs, parts replaced, and any other relevant information for future reference.\nMaintenance Tips\nRegular Testing: Conduct periodic self-tests and inspections to identify potential issues early.\nBattery Maintenance: Keep battery terminals clean and ensure connections are tight.\nCooling: Ensure proper ventilation around the UPS to prevent overheating.\nEnvironment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures.\nWhen to Seek Professional Help\nIf issues are complex or beyond basic troubleshooting, consult a professional service.\nUse authorized Vertiv service centers for repairs to ensure quality and warranty compliance.\nConclusion\nRepairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 98,
"imageuri": "https://bizimages.withfloats.com/actual/76237a5ae75049919100d38e7c2a2aad.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/76237a5ae75049919100d38e7c2a2aad.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-23T06:26:22.4Z",
"updatedon": "2024-10-23T06:26:22.4Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//vertiv-1kva-ups-repair-in-alwar-bhiwadi/98",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "UPS Rental & UPS Repairing Service",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "671894f87b19ca400cddba58",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv Ups Repairing In Ardee City Gurgaon",
"description": "Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations:\n\n\nUPS Repair Process\nInitial Assessment\n\nIdentify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms.\nVisual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections.\nDiagnosis\n\nSelf-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues.\nMultimeter Testing: Measure voltage, current, and resistance to identify electrical issues.\nBattery Testing: Check the health of the batteries using a battery tester or multimeter.\nCheck Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning.\nCommon Issues\n\nBattery Failure: Batteries may need replacement due to age or over-discharge.\nCapacitor Issues: Capacitors can fail due to heat or age, leading to performance issues.\nCooling Problems: Blocked fans or insufficient ventilation can cause overheating.\nControl Board Malfunctions: Issues with the control board can affect the UPS's operation.\nInput/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry.\nRepair and Replacement\n\nBattery Replacement: Remove and replace old batteries with new ones of the same specifications.\nComponent Replacement: Replace faulty capacitors, fuses, or other components as diagnosed.\nResoldering Connections: Fix any broken or loose solder joints on the circuit board.\nSoftware/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance.\nTesting After Repair\n\nFunctional Testing: After repairs, perform a complete functional test of the UPS.\nLoad Testing: Test the UPS under load to ensure it can handle the required capacity.\nBattery Cycle Testing: Run the UPS on battery power to check for proper operation.\nFinal Inspection\n\nSafety Check: Ensure all repairs meet safety standards.\nDocumentation: Document the repairs, parts replaced, and any other relevant information for future reference.\nMaintenance Tips\nRegular Testing: Conduct regular self-tests and inspections to catch issues early.\nBattery Maintenance: Check battery connections and terminals periodically; keep them clean and tight.\nEnvironment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan.\nFirmware Updates: Keep the UPS firmware updated for improved performance and security.\nProfessional Repair Services\nWhen to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional.\nAuthorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs.\nConclusion\nRepairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 97,
"imageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-23T06:17:28.889Z",
"updatedon": "2024-10-23T06:17:28.889Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-ups-repairing-in-ardee-city-gurgaon/97",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "UPS Repair",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "670e1e0f2d20d47c6f775e23",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "ONLINE UPS REPAIRING SERVICE IN ANANDPUR BAWAL",
"description": "Here\\\\'s a comprehensive guide to repairing Vertiv and Liebert online UPS systems:\n\nPreparation\n\nBefore starting the repair process, ensure you have the necessary tools, documentation, and safety precautions in place. Familiarize yourself with the UPS system\\\\'s electrical and mechanical components.\n\nTools and Equipment\n\nMultimeter\nScrewdrivers (flathead and Phillips)\nTorx driver (for some models)\nWire strippers\nPliers and wrenches\nSafety glasses and gloves\nAnti-static wrist strap or mat\nSafety Precautions\n\nEnsure the UPS system is turned off and unplugged from the power source.\nVerify the system is properly grounded.\nWear protective gear, including safety glasses and gloves.\nAvoid touching electrical components or wires.\nCommon Faults and Repairs\n\nFaulty Battery\nSymptoms: UPS not holding charge, frequent shutdowns, or battery failure.\nRepair: Replace the faulty battery with a new one of the same type and rating.\nPower Module Failure\nSymptoms: UPS not functioning, error messages, or overheating.\nRepair: Replace the faulty power module with a new one of the same type and rating.\nControl Board Failure\nSymptoms: UPS not functioning, error messages, or erratic behavior.\nRepair: Replace the faulty control board with a new one of the same type and rating.\nFan Failure\nSymptoms: Overheating, noise, or reduced airflow.\nRepair: Replace the faulty fan with a new one of the same type and rating.\nCapacitor Failure\nSymptoms: UPS not functioning, error messages, or overheating.\nRepair: Replace the faulty capacitor with a new one of the same type and rating.\nRepair Procedures\n\nDisassembly\nRemove the UPS system\\\\'s outer casing and any internal components to access the faulty part.\nDocument the wiring and connections before disconnecting them.\nComponent Replacement\nRemove the faulty component and replace it with a new one of the same type and rating.\nEnsure proper connections and wiring.\nReassembly\nReassemble the UPS system in the reverse order of disassembly.\nEnsure all connections and wiring are secure.\nTesting and Verification\n\nVisual Inspection\nVerify all components are properly installed and connected.\nCheck for any signs of physical damage or wear.\nFunctional Testing\nTurn on the UPS system and verify it\\\\'s functioning correctly.\nTest the system under various load conditions.\nPerformance Verification\nVerify the UPS system\\\\'s performance meets the manufacturer\\\\'s specifications.\nCheck for any error messages or alarms.\nDocumentation and Record-Keeping\n\nRepair Log\nDocument the repair process, including the faulty component, replacement part, and any challenges encountered.\nInclude before-and-after photos or videos.\nSystem Configuration\nUpdate the UPS system\\\\'s configuration and settings, if necessary.\nVerify the system is properly configured and functioning correctly.\nAdditional Tips and Recommendations\n\nManufacturer\\\\'s Documentation\nConsult the manufacturer\\\\'s documentation and repair guides for specific instructions and recommendations.\nTraining and Certification\nConsider obtaining training and certification from the manufacturer or a reputable third-party organization.\nPreventive Maintenance\nRegularly perform preventive maintenance tasks to minimize the risk of future repairs.\nBy following this guide, you\\\\'ll be able to repair your Vertiv or Liebert online UPS system efficiently and effectively. Remember to always follow safety precautions and manufacturer\\\\'s recommendations to ensure a successful repair.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"new one",
"same type",
"faulty fan",
"Torx driver",
"faulty part",
"outer casing",
"power source",
"repair guides",
"reverse order",
"Common Faults",
"future repairs",
"repair process",
"error messages",
"Wire strippers",
"ANANDPUR BAWAL",
"Safety glasses",
"necessary tools",
"Additional Tips",
"physical damage",
"protective gear",
"battery failure",
"replacement part",
"erratic behavior",
"faulty component",
"faulty capacitor",
"successful repair",
"Repair Procedures",
"Visual Inspection",
"proper connections",
"Functional Testing",
"frequent shutdowns",
"comprehensive guide",
"internal components",
"faulty power module",
"System Configuration",
"Equipment Multimeter",
"Fan Failure Symptoms",
"faulty control board",
"electrical components",
"mechanical components",
"specific instructions",
"Component Replacement",
"mat Safety Precautions",
"Faulty Battery Symptoms",
"various load conditions",
"Anti-static wrist strap",
"Performance Verification",
"Record-Keeping Repair Log",
"Capacitor Failure Symptoms",
"Liebert online UPS systems",
"preventive maintenance tasks",
"ONLINE UPS REPAIRING SERVICE",
"Power Module Failure Symptoms",
"Control Board Failure Symptoms",
"reputable third-party organization"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 51,
"imageuri": "https://bizimages.withfloats.com/actual/6742f41b30604bca89ac983da9cd975e.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/6742f41b30604bca89ac983da9cd975e.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-15T07:47:27.701Z",
"updatedon": "2024-10-15T07:47:27.701Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/online-ups-repairing-service-in-anandpur-bawal/51",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "ONLINE UPS REPAIRING SERVICE IN ANANDPUR BAWAL",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67de4bd9042ffb8bd0390aa7",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Powerstack battery Testing ",
"description": "Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition:\n\nSteps to Test Powerstack Batteries:\n1. Visual Inspection\nCheck for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced.\n\nClean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water.\n\n2. Check Battery Voltage\nMeasure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts.\n\nFor a 24V battery, you should see a voltage of around 25.2 to 26.0 volts.\n\nUndercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty.\n\n3. Load Testing\nTest under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak.\n\nDC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff.\n\n4. Battery Charge Test\nCharge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size.\n\nMonitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger.\n\nEnd of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery.\n\n5. Conduct a Specific Gravity Test (for Lead-Acid Batteries)\nHydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty.\n\n6. Perform a Battery Health Check (Advanced)\nUse a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs.\n\nInternal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life.\n\n7. Monitor for Temperature\nBatteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system.\n\nSigns of a Failing Battery:\nRapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating.\n\nShort Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life.\n\nInconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery.\n\nPhysical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced.\n\nBattery Maintenance Tips:\nRegular Charging: Avoid deep discharges and always keep the battery charged.\n\nEnvironmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures.\n\nPeriodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly.\n\nUse the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging.\n\nConclusion:\nBattery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 248,
"imageuri": "https://bizimages.withfloats.com/actual/7f2c78a976e246efbe70882f742a421a.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/f8db1555dfa447dbb73d3446e6b45940.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-22T05:34:17.551Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/powerstack-battery-testing-/248",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Powerstack battery Testing ",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67da5d3df76648ad70e6ba3a",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "ALL TYPES OF UPS REPAIR",
"description": "UPS (Uninterruptible Power Supply) repair typically involves diagnosing and fixing issues related to power failures, battery problems, or malfunctioning components. Here are some common repair tasks:\n\nBattery Replacement: Batteries in UPS units degrade over time and may need replacing. This is one of the most common repairs.\n\nPower Supply Issues: Problems with the internal power supply circuit or malfunctioning capacitors can cause a UPS to fail to charge or provide backup power.\n\nOverheating Issues: Dust buildup or fan failure can cause the unit to overheat, requiring cleaning or fan replacement.\n\nInverter and Charger Problems: If the UPS isn't converting DC to AC power properly, it could be an inverter problem. Similarly, charger failures could stop the battery from charging.\n\nInternal Component Replacement: This may involve replacing transformers, fuses, or circuit boards that have failed.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"circuit boards",
"charger problems",
"malfunctioning capacitors",
"malfunctioning components",
"fan failure",
"ups units degrade",
"fan replacement inverter",
"ac power properly",
"overheat requiring cleaning",
"fixing issues related"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 241,
"imageuri": "https://bizimages.withfloats.com/actual/fe43ecd841304e5ba3810dfc414a3e94.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/a3c0b54bac9e4d5bb50f465d5334b3f3.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-19T05:59:25.313Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/all-types-of-ups-repair/241",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "ALL TYPES OF UPS REPAIR",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67ca9cb25716f22e86601481",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "All Types Of Ups & Batteries Repair And Maintenance Of Ups",
"description": "Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices.\n\nTypes of UPS Systems\nOffline/Standby UPS:\n\nDescription: Provides basic protection; switches to battery during a power outage.\nMaintenance: Regular battery checks and replacement every 3-5 years.\nLine-Interactive UPS:\n\nDescription: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations.\nMaintenance: Inspect and test the battery and inverter regularly; check for dust accumulation.\nOnline Double-Conversion UPS:\n\nDescription: Provides continuous power and isolates equipment from power issues.\nMaintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates.\nModular UPS:\n\nDescription: Scalable systems that allow for adding or removing modules based on power needs.\nMaintenance: Regular checks on each module, ensuring proper connections and functionality.\nTypes of Batteries Used in UPS\nLead-Acid Batteries:\n\nTypes: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel.\nMaintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity.\nLithium-Ion Batteries:\n\nDescription: Increasingly used due to longer life and lighter weight.\nMaintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates.\nNickel-Cadmium (NiCd) Batteries:\n\nDescription: Used in specific applications; known for durability.\nMaintenance: Regularly test for capacity and perform equalization charging.\nRepair and Maintenance Practices\n1. Routine Inspections\nVisual Checks: Inspect for physical damage, corrosion, or loose connections.\nEnvironmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity).\n2. Battery Maintenance\nTesting: Conduct regular load tests and capacity tests to assess battery health.\nCleaning: Clean terminals and connections to prevent corrosion.\nReplacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid).\n3. UPS Maintenance\nFirmware Updates: Keep the UPS firmware updated for optimal performance.\nComponent Checks: Inspect capacitors, fans, and other internal components for wear and tear.\nCooling System: Ensure that cooling fans are operational and that vents are not blocked.\n4. Emergency Procedures\nTesting: Regularly test the UPS under load conditions to ensure it functions correctly during an outage.\nDocumentation: Maintain records of all maintenance activities, repairs, and battery replacements.\n5. Professional Servicing\nScheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS.\nEmergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts.\nConclusion\nRegular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries.\n\nFor specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"35 years",
"capacity tests",
"functionality types",
"tailored solutions",
"significantly extend",
"timely repairs",
"rapid response",
"comprehensive inspections",
"functions correctly",
"load conditions",
"cooling fans",
"internal components",
"longer life",
"continuous power",
"comprehensive overview",
"ups failures",
"complex systems",
"ups systems",
"specific applications",
"performance check",
"isolates equipment",
"ups batteries repair",
"ups systems batteries",
"maintenance practices types",
"maintenance activities repairs",
"power issues maintenance",
"battery backup ideal",
"ups firmware updated",
"detailed maintenance plans",
"specific service providers",
"structured maintenance schedule",
"protecting sensitive equipment",
"maintenance regular checks",
"inverter regularly check",
"engaging professional services",
"manufacturer recommendations typically",
"physical damage corrosion",
"removing modules based",
"basic protection switches"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 202,
"imageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-07T07:13:54.328Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/all-types-of-ups-batteries-repair-and-maintenance-of-ups/202",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "All Types Of Ups & Batteries Repair And Maintenance Of Ups",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67ca92ad2a6ce6045a586b19",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Eaton 5SC UPS",
"description": "The Eaton 5SC UPS is designed for high-end residential, retail, and small business applications, offering reliable power protection. It features power ratings from 500 VA to 1500 VA, pure sine wave output, advanced LCD monitoring, and various connectivity options including USB and serial ports.\n\nKey Specifications:\n\nPower Ratings: 500 VA to 1500 VA\nOutput: Pure sine wave\nConnectivity: USB, serial, and relay\nBattery Type: Sealed lead-acid, maintenance-free\nDimensions: Varies by model\nWeight: Approximately 34 lbs to 50 lbs depending on the model\nFor more detailed specifications and features, you can refer to the Eaton website or the technical datasheets available in the search results. The Eaton 5SC UPS is a reliable uninterruptible power supply designed to protect sensitive electronic equipment in various environments, including small businesses and home offices.\n\n\nKey Features:\n\nPower Ratings: Available in multiple configurations, including 500 VA, 750 VA, 1000 VA, 1500 VA\nOutput Type: Pure sine wave output, ensuring compatibility with high-end workstations and storage systems\nBattery Technology: Utilizes sealed lead-acid batteries with Advanced Battery Management (ABM) technology, extending battery life by up to 50%\nConnectivity Options: Equipped with USB and serial ports for easy integration with various operating systems (Windows, Mac, Linux)\nDisplay: Features an advanced LCD screen that provides real-time information on battery status, load, and operating mode\nDesign: Compact tower style with multiple battery-protected outlets (5-15R) and Automatic Voltage Regulation (AVR)\nPerformance and Reliability:\n\nRun Time: Estimated run time varies based on load; for example, a 1500 VA unit can provide over an hour of backup for moderate loads\nWarranty: Comes with a 3-year warranty on the UPS system and internal batteries, along with a $150,000 load protection guarantee for connected equipment\nNoise Level: Generally quiet operation due to the absence of a fan, although some users report a low-level buzz from the unit\nUser Experience:\n\nSetup: Users find the setup process straightforward, aided by clear instructions and a user-friendly interface\nSoftware: Companion software is available for configuration, though some users report it can be glitchy and recommend using built-in OS features instead\nCustomer Feedback: Many customers appreciate the value for money, noting the unit's reliability and performance, while some have raised concerns about battery life and occasional noise during operation",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"500 va",
"1500 va unit",
"occasional noise",
"raised concerns",
"units reliability",
"money noting",
"customer feedback",
"clear instructions",
"lowlevel buzz",
"users report",
"internal batteries",
"realtime information",
"easy integration",
"serial ports",
"multiple configurations",
"small businesses",
"search results",
"technical datasheets",
"detailed specifications",
"50 lbs depending",
"connectivity options",
"battery life",
"ups system",
"3year warranty",
"highend workstations",
"battery status load",
"eaton 5sc ups",
"builtin os features",
"features power ratings",
"moderate loads warranty",
"highend residential retail",
"advanced lcd screen"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 197,
"imageuri": "https://bizimages.withfloats.com/actual/7349aabef11b494b897d7a2145b7b8a0.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/7349aabef11b494b897d7a2145b7b8a0.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-07T06:31:09.742Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/eaton-5sc-ups/197",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "5SC UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "672b119afa30a93a44b20cf3",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 6kVA PowerBank UPS IN FARIDABAD",
"description": "The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers.\n\nAlthough \"PowerBank\" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings.\n\nKey Features and Specifications:\n\n1. Topology:\nDouble Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power.\nThe On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter.\n\n2. Power Rating:\n6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment).\n\n3. Output Power:\nOutput Power: 4.8 kW to 5.4 kW (depending on load and configuration)\n\n4. Input and Output Specifications:\nInput Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode.\nOutput Voltage: 230V ± 2% (standard in most countries)\n\n5. Waveform Type:\nPure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems.\n\n6. Battery Configuration:\nBattery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries.\nBattery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities.\nThe system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times.\nExternal Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period.\n\n7. Charging Time:\nTypically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions.\n\n8. Backup Time (Runtime):\nThe backup time can range from 20 minutes to several hours, depending on the load.\nFor example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime.\nA full load of 6kVA will typically provide 10-15 minutes of backup time.\nIf the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages.\n\n9. Cooling System:\nThe UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use.\n\n10. Display and Monitoring:\nLCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters.\nAudible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults.\nSmart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS.\n\n11. Connectivity and Interfaces:\nUSB/Serial Ports: For communication with a connected computer or server for monitoring and management.\nSNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices.\nDry Contact Interface: Allows integration with building management or alert systems.\nOptional Software: Available for automated shutdown in the event of prolonged power outages, and event logging.\n\n12. Form Factor:\nTower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup.\n\n13. Additional Features:\nOverload Protection: Safeguards against exceeding the UPS's rated capacity.\nShort-Circuit Protection: Provides defense against electrical faults.\nAutomatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.\n",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"3 kVA",
"5.4 kW",
"4.8 kW",
"The UPS",
"50% load",
"full load",
"4-6 hours",
"medium to",
"20 minutes",
"SNMP Slots",
"brand name",
"UPS status",
"tower setup",
"LCD Display",
"exact model",
"low battery",
"Key Features",
"data centers",
"extended use",
"battery size",
"Battery Type",
"battery mode",
"Output Power",
"load capacity",
"event logging",
"10-15 minutes",
"system faults",
"several hours",
"Waveform Type",
"highest level",
"Charging Time",
"alert systems",
"Input Voltage",
"12V batteries",
"power failure",
"Battery Banks",
"specific model",
"Audible Alarms",
"most countries",
"marketing term",
"longer runtime",
"longer periods",
"Output Voltage",
"12. Form Factor",
"series features",
"extended period",
"VRLA) batteries",
"2. Power Rating",
"network systems",
"On-Line topology",
"extended runtime",
"user preferences",
"USB/Serial Ports",
"Sealed Lead-Acid",
"general overview",
"large businesses",
"Battery Capacity",
"critical systems",
"extended outages",
"wide input range",
"remote monitoring",
"9. Cooling System",
"electrical faults",
"Optional Software",
"networked devices",
"Double Conversion",
"IT infrastructure",
"higher capacities",
"continuous supply",
"automated shutdown",
"connected computer",
"critical equipment",
"high-quality power",
"zero transfer time",
"Overload Protection",
"connected equipment",
"sensitive equipment",
"building management",
"extended protection",
"Additional Features",
"medium server rooms",
"longer backup times",
"voltage fluctuations",
"fan-assisted cooling",
"medium-sized systems",
"pure sinewave output",
"larger power demands",
"real-time information",
"Battery Configuration",
"Output Specifications",
"Dry Contact Interface",
"battery backup systems",
"optimal battery health",
"incoming utility power",
"External Battery Packs",
"continuous power supply",
"prolonged power outages",
"rackmount configurations",
"environmental conditions",
"high-demand environments",
"Short-Circuit Protection",
"Smart Battery Management",
"consistent power quality",
"external battery modules",
"Valve-Regulated Lead-Acid",
"higher power applications",
"lower-quality UPS systems",
"extended battery runtimes",
"other important parameters",
"efficient heat dissipation",
"Automatic Voltage Regulation",
"integrated external batteries",
"The Vertiv 6kVA PowerBank UPS",
"detailed product specifications",
"Simple Network Management Protocol",
"additional external battery cabinets",
"Line-Interactive power protection solutions"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 161,
"imageuri": "https://bizimages.withfloats.com/actual/76ce7c6b4c744ba9b94ab60a79c3031e.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/76ce7c6b4c744ba9b94ab60a79c3031e.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-06T06:50:02.976Z",
"updatedon": "2024-11-06T06:50:02.976Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-6kva-powerbank-ups-in-faridabad/161",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "6 KVA POWERBANK",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}