"name": "Maintenance Tips for UPS Systems and Batteries",
"description": "Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips:\n\n1. Regular Inspection\nVisual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion.\nConnections: Ensure that all connections are secure and free from dust and corrosion.\n2. Battery Maintenance\nBattery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load.\nClean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting.\nCheck Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed.\n3. Environmental Considerations\nTemperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly.\nVentilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow.\n4. Regular Testing\nSelf-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature.\nLoad Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage.\n5. Firmware and Software Updates\nKeep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security.\nMonitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues.\n6. Battery Replacement\nFollow Manufacturer Guidelines: Replace batteries according to the manufacturer\\'s recommendations, typically every 3-5 years for lead-acid batteries.\nDispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety.\n7. Load Management\nAvoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life.\nBalanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded.\n8. Documentation\nKeep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance.\n9. Professional Maintenance\nSchedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems.\n10. User Training\nEducate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"35 years",
"maintenance tips",
"ups system",
"ups systems",
"rated capacity",
"distilled water",
"power outage",
"issues encountered",
"records maintain",
"overloaded 8 documentation",
"single outlet",
"receive alerts",
"functioning correctly",
"enclosed spaces",
"baking soda",
"check voltage",
"improve performance",
"ensure terminals",
"load evenly",
"required load",
"battery tester",
"software updates",
"corrosion connections ensure",
"ups monitoring software",
"leadacid batteries dispose",
"battery terminals clean",
"load clean terminals",
"track performance metrics",
"ensuring reliable performance",
"total load connected",
"install firmware updates",
"security monitoring software",
"manufacturers recommendations typically",
"electrolyte levels regularly",
"physical damage leaks"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 221,
"imageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-12T07:55:14.561Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/maintenance-tips-for-ups-systems-and-batteries-/221",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Maintenance Tips for UPS Systems and Batteries",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "6717480bed6bc27bad47e161",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 10kVA UPS Repair In Bilaspur Kalan Manesar",
"description": "\n\nWhen it comes to Vertiv 10kVA UPS repair and testing, it involves several key processes to ensure that the UPS functions correctly and reliably. Below are the details regarding Vertiv 10kVA UPS repair and testing:\n\nVertiv 10kVA UPS Repair\nCommon Issues:\n\nBattery Failure: Batteries may degrade over time and need replacement.\nInverter Problems: The inverter may fail to convert DC to AC power.\nOverheating: Excessive heat can damage internal components.\nFaulty Charging Circuit: Issues with the charging system can prevent batteries from charging properly.\nSoftware Failures: Problems with firmware can affect UPS functionality.\nRepair Process:\n\nDiagnosis:\n\nUse diagnostic tools to identify issues.\nCheck for error codes or alerts on the UPS display.\nComponent Testing:\n\nTest batteries for capacity and voltage.\nInspect the inverter and charging circuits for faults.\nReplacement of Parts:\n\nReplace faulty batteries with new ones.\nRepair or replace damaged circuit boards, inverters, or other components.\nCalibration:\n\nCalibrate the UPS settings to ensure optimal performance.\nFinal Testing:\n\nConduct a load test to verify that the UPS can handle its rated capacity.\nVertiv 10kVA UPS Testing\nTesting Procedures:\n\nVisual Inspection:\n\nCheck for physical damage, loose connections, or corrosion.\nBattery Testing:\n\nMeasure the voltage and capacity of the batteries.\nConduct a discharge test to ensure batteries can hold a charge.\nLoad Testing:\n\nConnect a load to the UPS and monitor its performance.\nEnsure that the UPS can supply power for the specified duration under load.\nTransfer Time Testing:\n\nMeasure the time it takes for the UPS to switch from mains to battery power and back.\nEfficiency Testing:\n\nAssess the efficiency of the UPS under various loads to ensure it meets manufacturer specifications.\nMaintenance Recommendations\nRegular Maintenance: Schedule regular checks (at least annually) to ensure all components are functioning correctly.\nBattery Replacement: Replace batteries every 3-5 years, depending on usage and manufacturer recommendations.\nFirmware Updates: Keep the UPS firmware updated to benefit from the latest features and fixes.\nConclusion\nProper repair and testing of Vertiv 10kVA UPS systems are crucial for ensuring reliable power backup. Regular maintenance can prevent unexpected failures and extend the lifespan of the unit. If you require further details on specific models or repair services, feel free to ask!",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 91,
"imageuri": "https://bizimages.withfloats.com/actual/a121bc19edb142a6bd12b9e5e5b202cf.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/a121bc19edb142a6bd12b9e5e5b202cf.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-22T06:36:59.265Z",
"updatedon": "2024-10-22T06:36:59.265Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-10kva-ups-repair-in-bilaspur-kalan-manesar/91",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "UPS Repair",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "670e1e0f2d20d47c6f775e23",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "ONLINE UPS REPAIRING SERVICE IN ANANDPUR BAWAL",
"description": "Here\\\\'s a comprehensive guide to repairing Vertiv and Liebert online UPS systems:\n\nPreparation\n\nBefore starting the repair process, ensure you have the necessary tools, documentation, and safety precautions in place. Familiarize yourself with the UPS system\\\\'s electrical and mechanical components.\n\nTools and Equipment\n\nMultimeter\nScrewdrivers (flathead and Phillips)\nTorx driver (for some models)\nWire strippers\nPliers and wrenches\nSafety glasses and gloves\nAnti-static wrist strap or mat\nSafety Precautions\n\nEnsure the UPS system is turned off and unplugged from the power source.\nVerify the system is properly grounded.\nWear protective gear, including safety glasses and gloves.\nAvoid touching electrical components or wires.\nCommon Faults and Repairs\n\nFaulty Battery\nSymptoms: UPS not holding charge, frequent shutdowns, or battery failure.\nRepair: Replace the faulty battery with a new one of the same type and rating.\nPower Module Failure\nSymptoms: UPS not functioning, error messages, or overheating.\nRepair: Replace the faulty power module with a new one of the same type and rating.\nControl Board Failure\nSymptoms: UPS not functioning, error messages, or erratic behavior.\nRepair: Replace the faulty control board with a new one of the same type and rating.\nFan Failure\nSymptoms: Overheating, noise, or reduced airflow.\nRepair: Replace the faulty fan with a new one of the same type and rating.\nCapacitor Failure\nSymptoms: UPS not functioning, error messages, or overheating.\nRepair: Replace the faulty capacitor with a new one of the same type and rating.\nRepair Procedures\n\nDisassembly\nRemove the UPS system\\\\'s outer casing and any internal components to access the faulty part.\nDocument the wiring and connections before disconnecting them.\nComponent Replacement\nRemove the faulty component and replace it with a new one of the same type and rating.\nEnsure proper connections and wiring.\nReassembly\nReassemble the UPS system in the reverse order of disassembly.\nEnsure all connections and wiring are secure.\nTesting and Verification\n\nVisual Inspection\nVerify all components are properly installed and connected.\nCheck for any signs of physical damage or wear.\nFunctional Testing\nTurn on the UPS system and verify it\\\\'s functioning correctly.\nTest the system under various load conditions.\nPerformance Verification\nVerify the UPS system\\\\'s performance meets the manufacturer\\\\'s specifications.\nCheck for any error messages or alarms.\nDocumentation and Record-Keeping\n\nRepair Log\nDocument the repair process, including the faulty component, replacement part, and any challenges encountered.\nInclude before-and-after photos or videos.\nSystem Configuration\nUpdate the UPS system\\\\'s configuration and settings, if necessary.\nVerify the system is properly configured and functioning correctly.\nAdditional Tips and Recommendations\n\nManufacturer\\\\'s Documentation\nConsult the manufacturer\\\\'s documentation and repair guides for specific instructions and recommendations.\nTraining and Certification\nConsider obtaining training and certification from the manufacturer or a reputable third-party organization.\nPreventive Maintenance\nRegularly perform preventive maintenance tasks to minimize the risk of future repairs.\nBy following this guide, you\\\\'ll be able to repair your Vertiv or Liebert online UPS system efficiently and effectively. Remember to always follow safety precautions and manufacturer\\\\'s recommendations to ensure a successful repair.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"new one",
"same type",
"faulty fan",
"Torx driver",
"faulty part",
"outer casing",
"power source",
"repair guides",
"reverse order",
"Common Faults",
"future repairs",
"repair process",
"error messages",
"Wire strippers",
"ANANDPUR BAWAL",
"Safety glasses",
"necessary tools",
"Additional Tips",
"physical damage",
"protective gear",
"battery failure",
"replacement part",
"erratic behavior",
"faulty component",
"faulty capacitor",
"successful repair",
"Repair Procedures",
"Visual Inspection",
"proper connections",
"Functional Testing",
"frequent shutdowns",
"comprehensive guide",
"internal components",
"faulty power module",
"System Configuration",
"Equipment Multimeter",
"Fan Failure Symptoms",
"faulty control board",
"electrical components",
"mechanical components",
"specific instructions",
"Component Replacement",
"mat Safety Precautions",
"Faulty Battery Symptoms",
"various load conditions",
"Anti-static wrist strap",
"Performance Verification",
"Record-Keeping Repair Log",
"Capacitor Failure Symptoms",
"Liebert online UPS systems",
"preventive maintenance tasks",
"ONLINE UPS REPAIRING SERVICE",
"Power Module Failure Symptoms",
"Control Board Failure Symptoms",
"reputable third-party organization"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 51,
"imageuri": "https://bizimages.withfloats.com/actual/6742f41b30604bca89ac983da9cd975e.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/6742f41b30604bca89ac983da9cd975e.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-15T07:47:27.701Z",
"updatedon": "2024-10-15T07:47:27.701Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/online-ups-repairing-service-in-anandpur-bawal/51",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "ONLINE UPS REPAIRING SERVICE IN ANANDPUR BAWAL",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67de4bd9042ffb8bd0390aa7",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Powerstack battery Testing ",
"description": "Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition:\n\nSteps to Test Powerstack Batteries:\n1. Visual Inspection\nCheck for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced.\n\nClean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water.\n\n2. Check Battery Voltage\nMeasure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts.\n\nFor a 24V battery, you should see a voltage of around 25.2 to 26.0 volts.\n\nUndercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty.\n\n3. Load Testing\nTest under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak.\n\nDC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff.\n\n4. Battery Charge Test\nCharge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size.\n\nMonitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger.\n\nEnd of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery.\n\n5. Conduct a Specific Gravity Test (for Lead-Acid Batteries)\nHydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty.\n\n6. Perform a Battery Health Check (Advanced)\nUse a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs.\n\nInternal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life.\n\n7. Monitor for Temperature\nBatteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system.\n\nSigns of a Failing Battery:\nRapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating.\n\nShort Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life.\n\nInconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery.\n\nPhysical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced.\n\nBattery Maintenance Tips:\nRegular Charging: Avoid deep discharges and always keep the battery charged.\n\nEnvironmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures.\n\nPeriodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly.\n\nUse the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging.\n\nConclusion:\nBattery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 248,
"imageuri": "https://bizimages.withfloats.com/actual/7f2c78a976e246efbe70882f742a421a.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/f8db1555dfa447dbb73d3446e6b45940.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-22T05:34:17.551Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/powerstack-battery-testing-/248",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Powerstack battery Testing ",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67da5d3df76648ad70e6ba3a",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "ALL TYPES OF UPS REPAIR",
"description": "UPS (Uninterruptible Power Supply) repair typically involves diagnosing and fixing issues related to power failures, battery problems, or malfunctioning components. Here are some common repair tasks:\n\nBattery Replacement: Batteries in UPS units degrade over time and may need replacing. This is one of the most common repairs.\n\nPower Supply Issues: Problems with the internal power supply circuit or malfunctioning capacitors can cause a UPS to fail to charge or provide backup power.\n\nOverheating Issues: Dust buildup or fan failure can cause the unit to overheat, requiring cleaning or fan replacement.\n\nInverter and Charger Problems: If the UPS isn't converting DC to AC power properly, it could be an inverter problem. Similarly, charger failures could stop the battery from charging.\n\nInternal Component Replacement: This may involve replacing transformers, fuses, or circuit boards that have failed.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"circuit boards",
"charger problems",
"malfunctioning capacitors",
"malfunctioning components",
"fan failure",
"ups units degrade",
"fan replacement inverter",
"ac power properly",
"overheat requiring cleaning",
"fixing issues related"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 241,
"imageuri": "https://bizimages.withfloats.com/actual/fe43ecd841304e5ba3810dfc414a3e94.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/a3c0b54bac9e4d5bb50f465d5334b3f3.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-19T05:59:25.313Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/all-types-of-ups-repair/241",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "ALL TYPES OF UPS REPAIR",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d5328fdb7fc0f04f83af80",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Battery Replacement In Faridabad",
"description": "Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each.\n\nTypes of Batteries and Their Replacement Process\n1. Lead-Acid Batteries\nCommon Types:\nFlooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells.\nSealed Lead-Acid (SLA): Maintenance-free and does not require water addition.\nAbsorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats.\nGel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications.\nReplacement Process:\nTurn off the system: Ensure the system is powered off, and disconnect it from the grid or load.\nSafety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases.\nDisconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal.\nRemove old batteries: Lift and remove the batteries carefully, especially if they're heavy.\nClean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water.\nInstall new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system and check the voltage and charging status.\nMaintenance Tips:\nRegularly check the electrolyte levels in flooded batteries.\nClean terminals and ensure the battery box or tray is secure.\n2. Lithium-Ion Batteries\nCommon Types:\nLithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan.\nLithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools.\nLithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications.\nLithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones.\nReplacement Process:\nTurn off the system: Disconnect the power source or system.\nSafety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage.\nDisconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal.\nRemove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries.\nInstall the new battery: Place the new battery in the same orientation and secure it.\nReconnect terminals: Attach the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly.\nMaintenance Tips:\nLithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range.\nBattery Management System (BMS) should be monitored to ensure proper functioning and safety.\n\nConclusion:\nBattery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation.\n\nLead-acid batteries need regular maintenance, especially flooded types.\nLithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance.\nAlways follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"system disconnect",
"common types",
"system ensure",
"replacement process",
"battery place",
"battery box",
"electrolyte levels",
"gel electrolyte",
"sla battery",
"battery replacement",
"system power",
"handling batteries",
"longer lifespan",
"batterys charging",
"typically lighter",
"handled carefully",
"generally safe",
"small devices",
"highpower applications",
"high efficiency",
"evs due",
"batteries place",
"baking soda",
"batteries carefully",
"batteries lift",
"sulfuric acid",
"ill provide",
"vary depending",
"batterypowered devices",
"faridabadbattery replacement",
"minimal maintenance",
"regular maintenance",
"power source",
"leadacid batteries",
"power systems",
"solar systems",
"positive terminal",
"water install",
"negative terminal",
"battery lithiumion batteries",
"leadacid batteries install",
"reconnect terminals attach",
"positive terminal remove",
"solar systems leadacid",
"evs power tools",
"negative terminal check",
"common maintenance task",
"installation leadacid batteries",
"ensure proper recycling",
"ensure proper functioning",
"drones power banks",
"adding distilled water",
"avoid environmental hazards",
"follow safety guidelines",
"requiring specific attention",
"avoid overheating shortcircuiting"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 231,
"imageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-15T07:55:59.544Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/battery-replacement-in-faridabad/231",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Battery Replacement In Faridabad",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d52d8a4507f670f3d4fa58",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Emerson 3-Phase Ups In Manesar",
"description": "Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues.\n\nKey Features of Emerson 3-Phase UPS:\nPower Capacity:\n\n3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model.\nSuitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings.\nTechnology:\n\nDouble Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging.\nEfficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs.\nBattery Management: Integrated advanced battery management for monitoring health, charge, and backup times.\nHigh Availability:\n\nDesigned to provide reliable power for mission-critical applications.\nHot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply.\nScalability: Many models allow for modular expansion, meaning you can add additional capacity as needed.\nInput/Output Voltage:\n\nInput Voltage: Common input voltages are 380V, 400V, and 415V (3-phase).\nOutput Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards.\nPower Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency.\nAdvanced Features:\n\nLCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring.\nRemote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics.\nBypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime.\nDesign and Durability:\n\nCompact Design: Many models are designed to be space-efficient without compromising on power or cooling needs.\nRack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs.\nThermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating.\nApplications:\n\nData Centers: Ensures uptime for servers and networking equipment.\nIndustrial Equipment: Protects critical machinery and automated systems from power failures.\nTelecommunications: Keeps communication systems running without interruption.\nHospitals: Supports life-saving equipment and systems that require constant power.\nCommercial Buildings: Ensures backup power for office systems and equipment.\nMaintenance and Service:\n\nSmart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required.\nServiceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition.\nProactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations.\nPopular Models:\nEmerson (now part of Vertiv) offers various UPS models under different series, such as:\n\nVertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications.\nVertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability.\nVertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications.\nAdvantages of Emerson 3-Phase UPS:\nHigh Reliability: Ensures critical equipment remains powered during power failures or fluctuations.\nAdvanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility.\nEnergy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact.\nScalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand.\n\nConclusion:\nEmerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"800 kva",
"10 kva",
"models batteries",
"equipment maintenance",
"small office",
"380v 400v",
"largescale facilities",
"ups models",
"excellent solutions",
"easily expand",
"data centers",
"remote monitoring",
"service contracts",
"comprehensive support",
"alert users",
"realtime alerts",
"remote access",
"realtime data",
"model suitable",
"wide range",
"ups remains",
"office systems",
"automated systems",
"offers scalability",
"vertiv offers",
"bypass mode",
"industrial commercial",
"robust design",
"higher depending",
"critical infrastructure",
"power failures",
"monitoring health charge",
"modular ups system",
"advanced cooling systems",
"emerson ups systems",
"ups systems typically",
"ensure uninterrupted operation",
"3phase systems depending",
"critical infrastructure applications",
"power failures telecommunications",
"emerson 3phase ups",
"communication systems running",
"environmental impact scalability",
"industrial applications advantages",
"vertiv liebert ita2",
"diagnostics bypass capability",
"high power factor",
"provide reliable power",
"power capacities generally",
"provide uninterrupted power",
"tower formats depending",
"durability compact design",
"avoid downtime design",
"require high uptime",
"flexibility energy efficiency",
"diagnostic tools faults",
"maintain efficient operation",
"add additional capacity",
"modular expansion meaning",
"reduce energy consumption"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 229,
"imageuri": "https://bizimages.withfloats.com/actual/187708a304fa44f1b41acc0e625a7a30.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/187708a304fa44f1b41acc0e625a7a30.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-15T07:34:34.549Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/emerson-3-phase-ups-in-manesar/229",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Emerson 3-Phase Ups In Manesar",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67ca9cb25716f22e86601481",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "All Types Of Ups & Batteries Repair And Maintenance Of Ups",
"description": "Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices.\n\nTypes of UPS Systems\nOffline/Standby UPS:\n\nDescription: Provides basic protection; switches to battery during a power outage.\nMaintenance: Regular battery checks and replacement every 3-5 years.\nLine-Interactive UPS:\n\nDescription: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations.\nMaintenance: Inspect and test the battery and inverter regularly; check for dust accumulation.\nOnline Double-Conversion UPS:\n\nDescription: Provides continuous power and isolates equipment from power issues.\nMaintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates.\nModular UPS:\n\nDescription: Scalable systems that allow for adding or removing modules based on power needs.\nMaintenance: Regular checks on each module, ensuring proper connections and functionality.\nTypes of Batteries Used in UPS\nLead-Acid Batteries:\n\nTypes: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel.\nMaintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity.\nLithium-Ion Batteries:\n\nDescription: Increasingly used due to longer life and lighter weight.\nMaintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates.\nNickel-Cadmium (NiCd) Batteries:\n\nDescription: Used in specific applications; known for durability.\nMaintenance: Regularly test for capacity and perform equalization charging.\nRepair and Maintenance Practices\n1. Routine Inspections\nVisual Checks: Inspect for physical damage, corrosion, or loose connections.\nEnvironmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity).\n2. Battery Maintenance\nTesting: Conduct regular load tests and capacity tests to assess battery health.\nCleaning: Clean terminals and connections to prevent corrosion.\nReplacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid).\n3. UPS Maintenance\nFirmware Updates: Keep the UPS firmware updated for optimal performance.\nComponent Checks: Inspect capacitors, fans, and other internal components for wear and tear.\nCooling System: Ensure that cooling fans are operational and that vents are not blocked.\n4. Emergency Procedures\nTesting: Regularly test the UPS under load conditions to ensure it functions correctly during an outage.\nDocumentation: Maintain records of all maintenance activities, repairs, and battery replacements.\n5. Professional Servicing\nScheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS.\nEmergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts.\nConclusion\nRegular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries.\n\nFor specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"35 years",
"capacity tests",
"functionality types",
"tailored solutions",
"significantly extend",
"timely repairs",
"rapid response",
"comprehensive inspections",
"functions correctly",
"load conditions",
"cooling fans",
"internal components",
"longer life",
"continuous power",
"comprehensive overview",
"ups failures",
"complex systems",
"ups systems",
"specific applications",
"performance check",
"isolates equipment",
"ups batteries repair",
"ups systems batteries",
"maintenance practices types",
"maintenance activities repairs",
"power issues maintenance",
"battery backup ideal",
"ups firmware updated",
"detailed maintenance plans",
"specific service providers",
"structured maintenance schedule",
"protecting sensitive equipment",
"maintenance regular checks",
"inverter regularly check",
"engaging professional services",
"manufacturer recommendations typically",
"physical damage corrosion",
"removing modules based",
"basic protection switches"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 202,
"imageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-07T07:13:54.328Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/all-types-of-ups-batteries-repair-and-maintenance-of-ups/202",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "All Types Of Ups & Batteries Repair And Maintenance Of Ups",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "672c53984c2d7366708cbc86",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 2kva Ups Repair In Milakpur Goojar Bhiwadi",
"description": "Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations.\n\nWhen a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair:\n\nCommon Problems in Vertiv 2kVA UPS\nUPS Not Turning On\n\nPossible Causes:\nFaulty battery or dead battery\nBlown fuse or circuit breaker\nPower supply input issue (fuse or switch)\nRepair Action:\nCheck and replace the battery if necessary.\nInspect the fuse or circuit breaker and replace if blown.\nVerify the input power connections.\nFrequent Switching to Battery Mode\n\nPossible Causes:\nInput power fluctuations or poor power quality\nBattery failure or degraded battery capacity\nUPS in bypass mode due to an internal fault\nRepair Action:\nTest the incoming voltage using a multimeter to ensure it’s within the UPS input range.\nCheck the battery voltage; if it\\'s low, consider replacing the battery.\nCheck if the UPS is in bypass mode and reset it if necessary.\nUPS Not Charging the Battery\n\nPossible Causes:\nFaulty charger circuit\nBad battery connections or corroded terminals\nDefective charging board\nRepair Action:\nInspect battery terminals for corrosion and clean them.\nTest the charging voltage and check for proper charging circuit operation.\nIf the charger board is defective, it may need to be replaced.\nOverheating and Shutdown\n\nPossible Causes:\nOverloaded UPS (too many devices connected)\nPoor ventilation or blocked air vents\nFaulty cooling fan\nRepair Action:\nDisconnect unnecessary devices and reduce the load.\nEnsure the UPS has proper ventilation and airflow around it.\nCheck the fan for functionality; replace if faulty.\nUPS Producing Beeping Sound\n\nPossible Causes:\nLow battery\nOverload condition\nInternal fault or failure of components\nRepair Action:\nReplace or recharge the battery if it’s low.\nDisconnect some load if the UPS is overloaded.\nIf the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.).\nOutput Voltage Issues (Distorted or Incorrect Voltage)\n\nPossible Causes:\nFaulty inverter or rectifier circuit\nProblem with the output transformer\nFaulty output relay or PCB\nRepair Action:\nMeasure the output voltage and compare it with the rated output.\nInspect the inverter and rectifier circuits for any faults or blown components.\nCheck the PCB for signs of damage or burnt components.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 168,
"imageuri": "https://bizimages.withfloats.com/actual/28e96b99b645455c873c3014961a11b6.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/28e96b99b645455c873c3014961a11b6.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-11-07T05:43:52.98Z",
"updatedon": "2024-11-07T05:43:52.98Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-2kva-ups-repair-in-milakpur-goojar-bhiwadi/168",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "2kva ups repair",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}