"products": [
{
"_id": "67de50f12d762c4c27178365",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Amaron Quanta 12v 42Ah Battery",
"description": "The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial.\n\nKey Features of Amaron Quanta 42Ah Battery:\nCapacity:\n\n42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load.\n\nTechnology:\n\nMaintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free.\n\nHigh Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter.\n\nDeep Cycle Battery:\n\nThis is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently.\n\nDurability:\n\nLong Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored.\n\nHigh-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions.\n\nDesign:\n\nCompact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern.\n\nVibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings.\n\nSafety Features:\n\nFlame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction.\n\nLeak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety.\n\nApplication Areas:\n\nUPS Systems: Provides backup power to computers, servers, and networking equipment.\n\nInverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages.\n\nSolar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night.\n\nWarranty:\n\nThe Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details.\n\nGeneral Specifications:\nVoltage: 12V (standard for most UPS and inverter batteries).\n\nCapacity: 42Ah.\n\nType: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat).\n\nCharging Voltage: Typically around 14.4 to 15.0V for 12V batteries.\n\nNominal Voltage: 12V.\n\nDimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model).\n\nWeight: Approximately 12-14 kg.\n\nMaintenance Tips for the Amaron Quanta 42Ah Battery:\nRegular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan.\n\nStorage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically.\n\nClean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed.\n\nAvoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it.\n\nCheck for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear.\n\nBattery Testing:\nTo check the health of the Amaron Quanta 42Ah battery, you can follow these steps:\n\nVoltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V.\n\nLoad Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation.\n\nCapacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold.\n\nConclusion:\nThe Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 249,
"imageuri": "https://bizimages.withfloats.com/actual/1d085d444be04b38886a66b6877f7848.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/6ffad887d34b4ebd8fcc808aeb3d9a29.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-22T05:56:01.145Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-42ah-battery/249",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Amaron Quanta 12v 42Ah Battery",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67de4bd9042ffb8bd0390aa7",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Powerstack battery Testing ",
"description": "Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition:\n\nSteps to Test Powerstack Batteries:\n1. Visual Inspection\nCheck for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced.\n\nClean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water.\n\n2. Check Battery Voltage\nMeasure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts.\n\nFor a 24V battery, you should see a voltage of around 25.2 to 26.0 volts.\n\nUndercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty.\n\n3. Load Testing\nTest under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak.\n\nDC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff.\n\n4. Battery Charge Test\nCharge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size.\n\nMonitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger.\n\nEnd of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery.\n\n5. Conduct a Specific Gravity Test (for Lead-Acid Batteries)\nHydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty.\n\n6. Perform a Battery Health Check (Advanced)\nUse a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs.\n\nInternal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life.\n\n7. Monitor for Temperature\nBatteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system.\n\nSigns of a Failing Battery:\nRapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating.\n\nShort Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life.\n\nInconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery.\n\nPhysical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced.\n\nBattery Maintenance Tips:\nRegular Charging: Avoid deep discharges and always keep the battery charged.\n\nEnvironmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures.\n\nPeriodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly.\n\nUse the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging.\n\nConclusion:\nBattery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 248,
"imageuri": "https://bizimages.withfloats.com/actual/7f2c78a976e246efbe70882f742a421a.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/f8db1555dfa447dbb73d3446e6b45940.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-22T05:34:17.551Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//powerstack-battery-testing-/248",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Powerstack battery Testing ",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d13de22912ddb97fcecda8",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Maintenance Tips for UPS Systems and Batteries",
"description": "Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips:\n\n1. Regular Inspection\nVisual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion.\nConnections: Ensure that all connections are secure and free from dust and corrosion.\n2. Battery Maintenance\nBattery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load.\nClean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting.\nCheck Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed.\n3. Environmental Considerations\nTemperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly.\nVentilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow.\n4. Regular Testing\nSelf-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature.\nLoad Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage.\n5. Firmware and Software Updates\nKeep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security.\nMonitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues.\n6. Battery Replacement\nFollow Manufacturer Guidelines: Replace batteries according to the manufacturer\\'s recommendations, typically every 3-5 years for lead-acid batteries.\nDispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety.\n7. Load Management\nAvoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life.\nBalanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded.\n8. Documentation\nKeep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance.\n9. Professional Maintenance\nSchedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems.\n10. User Training\nEducate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"35 years",
"maintenance tips",
"ups system",
"ups systems",
"rated capacity",
"distilled water",
"power outage",
"issues encountered",
"records maintain",
"overloaded 8 documentation",
"single outlet",
"receive alerts",
"functioning correctly",
"enclosed spaces",
"baking soda",
"check voltage",
"improve performance",
"ensure terminals",
"load evenly",
"required load",
"battery tester",
"software updates",
"corrosion connections ensure",
"ups monitoring software",
"leadacid batteries dispose",
"battery terminals clean",
"load clean terminals",
"track performance metrics",
"ensuring reliable performance",
"total load connected",
"install firmware updates",
"security monitoring software",
"manufacturers recommendations typically",
"electrolyte levels regularly",
"physical damage leaks"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 221,
"imageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-12T07:55:14.561Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/maintenance-tips-for-ups-systems-and-batteries-/221",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Maintenance Tips for UPS Systems and Batteries",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "6720980b2b5881cbadcda4e8",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Repairing And Maintaining UPS In Delhi",
"description": "Repairing And Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring the reliability and longevity of the power backup system. Here’s a detailed overview of UPS battery maintenance and repair practices.\n\nUPS Battery Types\nLead-Acid Batteries:\n\nValve-Regulated Lead Acid (VRLA): Maintenance-free and sealed, suitable for most UPS systems.\nFlooded Lead Acid: Requires periodic maintenance and water topping.\nLithium-Ion Batteries:\n\nIncreasingly used due to longer life and higher efficiency but may require specific handling protocols.\nMaintenance Practices\nRegular Inspections:\n\nVisual Check: Inspect batteries for physical damage, corrosion, or leaks. Look for swelling or bulging in case of lead-acid batteries.\nConnections: Ensure all terminals and connections are tight and free of corrosion.\nCleaning:\n\nClean battery terminals with a mixture of baking soda and water to remove corrosion. Rinse with clean water and dry thoroughly.\nBattery Testing:\n\nVoltage Checks: Regularly measure the voltage of each battery to identify weak cells.\nLoad Testing: Perform load tests to ensure the battery can deliver the expected capacity under load conditions.\nTemperature Monitoring:\n\nMonitor battery temperature, especially in environments with high heat, as excessive temperatures can affect battery performance and lifespan.\nElectrolyte Level (for Flooded Batteries):\n\nCheck and maintain the electrolyte levels in flooded lead-acid batteries. Top up with distilled water as necessary.\nBattery Health Monitoring:\n\nUse battery management systems (BMS) for advanced monitoring of battery health, state of charge, and state of health.\nRepair Practices\nIdentifying Faults:\n\nCommon issues include short-circuited cells, sulfation, and capacity loss. Use diagnostic tools to identify problems.\nReplacing Individual Batteries:\n\nIf a battery within a pack fails, replace only the faulty battery if it’s compatible. However, it's often recommended to replace all batteries in a series to ensure uniform performance.\nEqualization Charging (for Flooded Batteries):\n\nPeriodically perform equalization charging to balance the charge across all cells and prevent sulfation.\nReconditioning:\n\nSome lead-acid batteries can be reconditioned through a process of controlled charging and discharging to restore capacity. This is not always successful and should be done by professionals.\nBattery Replacement:\n\nWhen batteries reach the end of their lifespan (typically 3-5 years for lead-acid), replace them with new ones. Ensure that replacements meet the manufacturer's specifications.\nBest Practices for Maintenance\nDocumentation:\n\nKeep records of inspections, tests, and replacements to track battery performance over time.\nEnvironmental Conditions:\n\nMaintain an optimal environment for batteries—ideally, a cool, dry place free from excessive humidity and temperature fluctuations.\nProfessional Servicing:\n\nConsider engaging professionals for complex repairs or maintenance tasks, especially for large or critical UPS systems.\nTraining:\n\nTrain personnel on proper handling, maintenance, and safety procedures related to UPS batteries.\nConclusion\nRegular maintenance and timely repairs of UPS batteries are essential for ensuring the reliability of power backup systems. By implementing best practices, monitoring battery health, and addressing issues promptly, you can prolong the life of your UPS batteries and enhance overall system performance. If you have specific questions or need further details on any aspect, feel free to ask!",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"3-5 years",
"high heat",
"load tests",
"weak cells",
"longer life",
"baking soda",
"clean water",
"Load Testing",
"Visual Check",
"Common issues",
"capacity loss",
"water topping",
"UPS batteries",
"Voltage Checks",
"timely repairs",
"Best Practices",
"faulty battery",
"Delhi Repairing",
"distilled water",
"complex repairs",
"load conditions",
"physical damage",
"Battery Testing",
"Maintaining UPS",
"cool, dry place",
"diagnostic tools",
"repair practices",
"most UPS systems",
"expected capacity",
"safety procedures",
"maintenance tasks",
"Electrolyte Level",
"higher efficiency",
"detailed overview",
"Flooded Batteries",
"UPS Battery Types",
"Flooded Lead Acid",
"excessive humidity",
"specific questions",
"Lead-Acid Batteries",
"Regular Inspections",
"Regular maintenance",
"optimal environment",
"Battery Replacement",
"battery temperature",
"uniform performance",
"advanced monitoring",
"battery performance",
"power backup system",
"Individual Batteries",
"periodic maintenance",
"critical UPS systems",
"Equalization Charging",
"short-circuited cells",
"Lithium-Ion Batteries",
"Maintenance Practices",
"Professional Servicing",
"excessive temperatures",
"Temperature Monitoring",
"UPS battery maintenance",
"Clean battery terminals",
"temperature fluctuations",
"Environmental Conditions",
"Maintenance Documentation",
"Battery Health Monitoring",
"Valve-Regulated Lead Acid",
"battery management systems",
"overall system performance",
"specific handling protocols",
"Uninterruptible Power Supply"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 131,
"imageuri": "https://bizimages.withfloats.com/actual/1c0f13c6e9d34936ad199dbe084446a5.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/1c0f13c6e9d34936ad199dbe084446a5.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-29T08:08:43.949Z",
"updatedon": "2024-10-29T08:08:43.949Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/repairing-and-maintaining-ups-in-delhi/131",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Repairing And Maintaining UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "670e1c06d01c6d0a629edb17",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "UPS & BATTERIES MAINTENANCE IN SECTOR 55 NOIDA",
"description": "Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring reliable performance and extending their lifespan. Here’s a comprehensive guide on UPS battery maintenance:\n\n1. Regular Inspection\nVisual Checks: Inspect batteries for physical damage, leaks, or corrosion.\nConnections: Ensure that terminals and connections are tight and free from corrosion.\n\n2. Battery Testing\nLoad Testing: Conduct regular load tests to ensure batteries can handle the expected load.\nVoltage Checks: Measure the voltage of each battery regularly to identify weak cells.\n\n3. Cleaning\nDust and Debris: Keep the battery area clean and free from dust. Use a soft brush or cloth.\nCorrosion Removal: Clean any corrosion from terminals with a solution of baking soda and water.\n\n4. Temperature Monitoring\nOperating Temperature: Keep batteries within the manufacturer’s recommended temperature range (typically 20-25°C).\nVentilation: Ensure proper airflow around the batteries to prevent overheating.\n\n5. Charging Practices\nRegular Charging: Ensure batteries are charged regularly, even if the UPS is not in use.\nAvoid Deep Discharge: Do not allow batteries to discharge below the recommended level.\n\n6. Battery Replacement\nAge and Cycle Life: Be aware of the expected lifespan (usually 3-5 years for lead-acid batteries) and replace batteries as needed.\nUse OEM Batteries: Always replace with original equipment manufacturer (OEM) batteries to ensure compatibility.\n\n7. Documentation and Logs\nMaintenance Log: Keep records of inspections, tests, and replacements.\nBattery Specifications: Document battery type, installation date, and capacity for reference.\n\n8. Environmental Considerations\nDisposal: Follow local regulations for disposing of old batteries.\nStorage: Store spare batteries in a cool, dry place.\n\n9. Professional Servicing\nAnnual Maintenance: Consider scheduling annual inspections by a professional to assess battery health.\n\n10. Safety Precautions\nPersonal Protective Equipment (PPE): Always wear gloves and safety goggles when handling batteries.\nEmergency Procedures: Be familiar with emergency procedures in case of battery leaks or failures.\n\nBy following these maintenance tips, you can ensure your UPS batteries operate efficiently and last longer. Regular upkeep is key to preventing unexpected failures and ensuring reliable power during outages.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"3-5 years",
"soft brush",
"weak cells",
"baking soda",
"battery area",
"UPS batteries",
"old batteries",
"OEM Batteries",
"battery leaks",
"Visual Checks",
"expected load",
"Voltage Checks",
"OEM) batteries",
"safety goggles",
"Deep Discharge",
"proper airflow",
"Regular upkeep",
"battery health",
"reliable power",
"spare batteries",
"Maintaining UPS",
"physical damage",
"SECTOR 55 NOIDA",
"Maintenance Log",
"cool, dry place",
"maintenance tips",
"Regular Charging",
"Corrosion Removal",
"local regulations",
"installation date",
"temperature range",
"annual inspections",
"Safety Precautions",
"Charging Practices",
"Annual Maintenance",
"Regular Inspection",
"regular load tests",
"unexpected failures",
"lead-acid batteries",
"comprehensive guide",
"Battery Replacement",
"Emergency Procedures",
"reliable performance",
"BATTERIES MAINTENANCE",
"Operating Temperature",
"Document battery type",
"Professional Servicing",
"Battery Specifications",
"UPS battery maintenance",
"4. Temperature Monitoring",
"Environmental Considerations",
"Battery Testing Load Testing",
"Personal Protective Equipment",
"original equipment manufacturer",
"Uninterruptible Power Supply) batteries"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 50,
"imageuri": "https://bizimages.withfloats.com/actual/7cbb16886dd0413a91f7ee36ebc95325.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/7cbb16886dd0413a91f7ee36ebc95325.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-15T07:38:46.507Z",
"updatedon": "2024-10-15T07:38:46.507Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/ups-batteries-maintenance-in-sector-55-noida/50",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "UPS & BATTERIES MAINTENANCE IN SECTOR 55 NOIDA",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67f4bc962133e85be6b62113",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Exide Bike Battery In Bhiwadi",
"description": "Exide bike batteries are designed for high performance and durability in two-wheelers. Here are key details:\n\nType: VRLA (Valve Regulated Lead Acid) and conventional flooded batteries, suitable for different bike models.\n\nFeatures: Maintenance-free, spill-proof, vibration-resistant, and designed for quick starting power.\n\nApplications: Used in motorcycles, scooters, and other two-wheelers for reliable starting and backup power.\n\nDurability: High resistance to extreme temperatures and rough road conditions.\n\nMaintenance: Low maintenance with easy water level checks (for conventional types).\n\nExide is a trusted brand for two-wheeler batteries, known for its long-lasting performance and reliability.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"longlasting performance",
"trusted brand",
"extreme temperatures",
"reliable starting",
"motorcycles scooters",
"high performance",
"twowheeler batteries",
"bhiwadiexide bike batteries",
"conventional types exide",
"exide bike battery"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 253,
"imageuri": "https://bizimages.withfloats.com/actual/89e0b80ae8d2492f87f33e99000c28e0.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/89e0b80ae8d2492f87f33e99000c28e0.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-04-08T06:05:10.684Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/exide-bike-battery-in-bhiwadi/253",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Exide Bike Battery In Bhiwadi",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67f4bba3414e7cbef64febbb",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Battery Testing In Sonipat",
"description": "Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details:\n\nTypes of Tests:\n\nVoltage Test: Measures the battery's output voltage to check if it meets the specified range.\n\nCapacity Test: Assesses how much charge the battery can hold and deliver over time.\n\nLoad Test: Simulates real-world usage to check how the battery performs under load.\n\nInternal Resistance Test: Evaluates the battery's internal resistance, indicating its health.\n\nTools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers.\n\nFrequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures.\n\nIndicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage.\n\nProper battery testing helps in proactive maintenance, ensuring reliability and safety.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"battery performs",
"battery testing",
"physical damage",
"multimeter hydrometer",
"health tools",
"sonipatbattery testing",
"backup power systems",
"batterys output voltage",
"key details types"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 252,
"imageuri": "https://bizimages.withfloats.com/actual/c913575dfda84449995beac189bf35a3.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/c913575dfda84449995beac189bf35a3.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-04-08T06:01:07.782Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//battery-testing-in-sonipat/252",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Battery Testing In Sonipat",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67f4b9c72b2286bfb10ba03f",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Microtek inverter In Bawal",
"description": "Microtek inverters are popular for their reliability and efficiency in providing backup power solutions. Here are some key points:\n\nTypes: Available in pure sine wave, square wave, and modified sine wave models to suit different needs.\n\nApplications: Used for home, office, and industrial backup power systems.\n\nFeatures: Energy-efficient, low maintenance, with features like digital display, smart charging, and battery management systems.\n\nCompatibility: Works well with various battery types, including lead-acid and lithium-ion.\n\nDurability: Built to withstand power fluctuations and extreme conditions.\n\nMicrotek is known for its durable and cost-effective inverters, widely used across India and other regions.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"home office",
"battery types",
"bawalmicrotek inverters",
"microtek inverter",
"costeffective inverters widely",
"extreme conditions microtek",
"key points types",
"withstand power fluctuations",
"lithiumion durability built"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 251,
"imageuri": "https://bizimages.withfloats.com/actual/5478edc79e144833b7b4e2137a59f6fd.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/5478edc79e144833b7b4e2137a59f6fd.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-04-08T05:53:11.21Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/microtek-inverter-in-bawal/251",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Microtek inverter In Bawal",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67f4b7bce2788eeab48da076",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Amaron Tubular Battery In Faridabad",
"description": "Amaron tubular batteries are a type of rechargeable battery known for their durability and long service life, making them ideal for deep-cycle applications. Here are some key points:\n\nDesign: They use tubular plates, which provide a longer lifespan compared to flat plates, especially in deep discharge conditions.\n\nApplications: Commonly used in inverters, solar power systems, and other backup power solutions.\n\nDurability: Known for high resistance to corrosion and low maintenance requirements.\n\nPerformance: Excellent charge retention and high power output, even in harsh conditions.\n\nMaintenance: Requires periodic checking of water levels and occasional equalization charging.\n\nAmaron is a well-known brand in the Indian market, popular for its robust and reliable battery solutions.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"wellknown brand",
"water levels",
"flat plates",
"deepcycle applications",
"high resistance",
"tubular plates",
"rechargeable battery",
"amaron tubular battery",
"high power output",
"reliable battery solutions",
"faridabadamaron tubular batteries",
"indian market popular",
"longer lifespan compared",
"key points design"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 250,
"imageuri": "https://bizimages.withfloats.com/actual/d756756cc4c74fc4a826d83278282b23.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/d756756cc4c74fc4a826d83278282b23.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-04-08T05:44:28.225Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-tubular-battery-in-faridabad/250",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Amaron Tubular Battery In Faridabad",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}