Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "6718970e453b0f6645adf709",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv 1kva Ups Repair In Alwar Bhiwadi",
"description": "Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems:\n\nRepair Process\nInitial Assessment\n\nGather Information: Document symptoms such as alarms, performance issues, or failure to start.\nVisual Inspection: Look for signs of physical damage, burnt components, or loose connections.\nDiagnosis\n\nSelf-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes.\nMultimeter Testing: Use a multimeter to check voltage levels, current, and resistance.\nBattery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity.\nInspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault.\nCommon Issues\n\nBattery Failure: The most common issue; batteries may need replacement due to age or improper charging.\nCapacitor Issues: Capacitors can degrade over time, leading to performance problems.\nOverheating: Caused by dust accumulation, blocked ventilation, or fan failure.\nControl Board Failures: Issues with the control board can affect functionality.\nInput/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues.\nRepair and Replacement\n\nBattery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity.\nComponent Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics.\nSoldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board.\nFirmware Updates: If applicable, update the firmware for optimal performance.\nTesting After Repair\n\nFunctional Testing: Run the UPS to ensure it operates correctly.\nLoad Testing: Test under load conditions to verify performance and capacity.\nBattery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected.\nFinal Inspection\n\nSafety Checks: Verify that all repairs meet safety standards.\nDocumentation: Record all repairs, parts replaced, and any other relevant information for future reference.\nMaintenance Tips\nRegular Testing: Conduct periodic self-tests and inspections to identify potential issues early.\nBattery Maintenance: Keep battery terminals clean and ensure connections are tight.\nCooling: Ensure proper ventilation around the UPS to prevent overheating.\nEnvironment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures.\nWhen to Seek Professional Help\nIf issues are complex or beyond basic troubleshooting, consult a professional service.\nUse authorized Vertiv service centers for repairs to ensure quality and warranty compliance.\nConclusion\nRepairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 98,
"imageuri": "https://bizimages.withfloats.com/actual/76237a5ae75049919100d38e7c2a2aad.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/76237a5ae75049919100d38e7c2a2aad.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-23T06:26:22.4Z",
"updatedon": "2024-10-23T06:26:22.4Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//vertiv-1kva-ups-repair-in-alwar-bhiwadi/98",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "UPS Rental & UPS Repairing Service",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "671894f87b19ca400cddba58",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv Ups Repairing In Ardee City Gurgaon",
"description": "Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations:\n\n\nUPS Repair Process\nInitial Assessment\n\nIdentify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms.\nVisual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections.\nDiagnosis\n\nSelf-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues.\nMultimeter Testing: Measure voltage, current, and resistance to identify electrical issues.\nBattery Testing: Check the health of the batteries using a battery tester or multimeter.\nCheck Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning.\nCommon Issues\n\nBattery Failure: Batteries may need replacement due to age or over-discharge.\nCapacitor Issues: Capacitors can fail due to heat or age, leading to performance issues.\nCooling Problems: Blocked fans or insufficient ventilation can cause overheating.\nControl Board Malfunctions: Issues with the control board can affect the UPS's operation.\nInput/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry.\nRepair and Replacement\n\nBattery Replacement: Remove and replace old batteries with new ones of the same specifications.\nComponent Replacement: Replace faulty capacitors, fuses, or other components as diagnosed.\nResoldering Connections: Fix any broken or loose solder joints on the circuit board.\nSoftware/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance.\nTesting After Repair\n\nFunctional Testing: After repairs, perform a complete functional test of the UPS.\nLoad Testing: Test the UPS under load to ensure it can handle the required capacity.\nBattery Cycle Testing: Run the UPS on battery power to check for proper operation.\nFinal Inspection\n\nSafety Check: Ensure all repairs meet safety standards.\nDocumentation: Document the repairs, parts replaced, and any other relevant information for future reference.\nMaintenance Tips\nRegular Testing: Conduct regular self-tests and inspections to catch issues early.\nBattery Maintenance: Check battery connections and terminals periodically; keep them clean and tight.\nEnvironment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan.\nFirmware Updates: Keep the UPS firmware updated for improved performance and security.\nProfessional Repair Services\nWhen to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional.\nAuthorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs.\nConclusion\nRepairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 97,
"imageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-23T06:17:28.889Z",
"updatedon": "2024-10-23T06:17:28.889Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-ups-repairing-in-ardee-city-gurgaon/97",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "UPS Repair",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67120454d449d74b99f70970",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Apc Ups Repairing And Maintenance In \tAurangabad Sonipat",
"description": "Repairing and testing an APC UPS (Uninterruptible Power Supply) involves several steps to diagnose issues and ensure the unit functions properly. Here’s a detailed guide on how to approach this:\n\nCommon Issues with APC UPS\nBattery Failure: Most common issue; symptoms include frequent beeping and inability to hold a charge.\nOverload: The UPS may beep continuously if connected devices exceed its capacity.\nFaulty Output: No power output despite being plugged in.\nFirmware Issues: May require updates or resets.\nTools Needed\nMultimeter\nScrewdriver set\nReplacement batteries (if needed)\nLaptop or PC for firmware updates\nDiagnostic software (if applicable)\nTesting Procedure\nVisual Inspection:\n\nCheck for physical damage, burnt components, or loose connections.\nInspect the battery for any signs of swelling or leakage.\nBattery Testing:\n\nDisconnect the UPS from the wall outlet.\nUse a multimeter to measure the battery voltage. Compare it to the rated voltage (e.g., 12V for most lead-acid batteries).\nIf the voltage is significantly lower, consider replacing the battery.\nLoad Testing:\n\nConnect a load tester to the UPS and apply a known load (within the UPS capacity).\nMonitor the output voltage and see if it remains stable under load.\nOutput Testing:\n\nPlug the UPS into the wall and turn it on.\nMeasure the output voltage with a multimeter to ensure it’s delivering the correct voltage (typically around 120V or 230V depending on your region).\nCheck if the UPS switches to battery mode when you disconnect it from the wall.\nOverload Testing:\n\nGradually increase the load on the UPS until it beeps or shuts down.\nVerify that it returns to normal operation once the overload is removed.\nRepair Procedures\nBattery Replacement:\n\nFollow the manufacturer’s guidelines for replacing batteries.\nDispose of old batteries responsibly.\nFirmware Updates:\n\nConnect the UPS to a computer.\nUse APC’s software (like PowerChute) to check for and install firmware updates.\nComponent Repair:\n\nIf internal components (like capacitors or fans) are damaged, soldering skills may be required for repairs or replacements.\nReassembly:\n\nCarefully reassemble the UPS, ensuring all screws are tightened and no wires are pinched.\nFinal Testing\nAfter repairs, conduct a full load test to ensure the UPS operates correctly under stress.\nMonitor for any unusual noises or overheating during operation.\nSafety Precautions\nAlways ensure the UPS is unplugged before performing internal inspections or repairs.\nHandle batteries with care, as they can be hazardous.\nConclusion\nRegular testing and maintenance of your APC UPS can extend its lifespan and ensure reliable performance. If issues persist after self-repair attempts, consider consulting a professional technician or contacting APC support for assistance.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"The UPS",
"wall outlet",
"load tester",
"APC support",
"UPS capacity",
"Load Testing",
"battery mode",
"common issue",
"power output",
"old batteries",
"rated voltage",
"Final Testing",
"Faulty Output",
"several steps",
"output voltage",
"unusual noises",
"Output Testing",
"detailed guide",
"full load test",
"Firmware Issues",
"battery voltage",
"Battery Testing",
"Battery Failure",
"correct voltage",
"Regular testing",
"physical damage",
"Screwdriver set",
"normal operation",
"firmware updates",
"soldering skills",
"Component Repair",
"burnt components",
"frequent beeping",
"Repair Procedures",
"loose connections",
"Visual Inspection",
"Testing Procedure",
"connected devices",
"Apc Ups Repairing",
"Safety Precautions",
"Aurangabad Sonipat",
"Diagnostic software",
"lead-acid batteries",
"Battery Replacement",
"internal components",
"self-repair attempts",
"reliable performance",
"internal inspections",
"Replacement batteries",
"professional technician",
"Uninterruptible Power Supply"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 73,
"imageuri": "https://bizimages.withfloats.com/actual/fe5e65ee545a4e2b8d06898bed2aa8fe.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/fe5e65ee545a4e2b8d06898bed2aa8fe.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-18T06:46:44.811Z",
"updatedon": "2024-10-18T06:46:44.811Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/apc-ups-repairing-and-maintenance-in-aurangabad-sonipat/73",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "Apc Ups Repairing And Maintenance In \tAurangabad Sonipat",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67f4bba3414e7cbef64febbb",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Battery Testing In Sonipat",
"description": "Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details:\n\nTypes of Tests:\n\nVoltage Test: Measures the battery's output voltage to check if it meets the specified range.\n\nCapacity Test: Assesses how much charge the battery can hold and deliver over time.\n\nLoad Test: Simulates real-world usage to check how the battery performs under load.\n\nInternal Resistance Test: Evaluates the battery's internal resistance, indicating its health.\n\nTools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers.\n\nFrequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures.\n\nIndicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage.\n\nProper battery testing helps in proactive maintenance, ensuring reliability and safety.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"battery performs",
"battery testing",
"physical damage",
"multimeter hydrometer",
"health tools",
"sonipatbattery testing",
"backup power systems",
"batterys output voltage",
"key details types"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 252,
"imageuri": "https://bizimages.withfloats.com/actual/c913575dfda84449995beac189bf35a3.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/c913575dfda84449995beac189bf35a3.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-04-08T06:01:07.782Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/battery-testing-in-sonipat/252",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Battery Testing In Sonipat",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d5300cc75e6ecb0a24be44",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "10 kW solar system installed at M3M",
"description": "Universal Power team has installed a 10 kW solar system 18 panel at M3M\nKey Details of the Installation:\nSolar System Size:\n\n10 kW refers to the capacity of the solar system. This means the system is designed to generate up to 10 kilowatts (kW) of power under optimal sunlight conditions.\nNumber of Panels:\n\n18 solar panels have been installed. To estimate the power output of each panel, we can divide the system\\'s total capacity by the number of panels.\n10 kW / 18 panels = approximately 555 watts per panel.\nThis indicates that each panel is likely rated around 555W, which is a common wattage for high-efficiency solar panels used in residential and commercial systems.\nLocation – M3M:\n\nM3M could be a residential complex, office building, or another commercial facility. Without more specific information, M3M could refer to the area or project where the installation took place. If it’s a large-scale installation, such as for an office or commercial building, the solar panels are likely being used to reduce energy costs and carbon footprint.\nEnergy Production:\n\nThe energy output of the system will depend on several factors, including the amount of sunlight received, panel orientation, and local weather conditions.\nIn an area with good sunlight, a 10 kW system could produce roughly 40-50 kWh per day on average, depending on the solar irradiance and hours of sunlight in that region. Over a year, this could amount to around 14, 600 to 18, 250 kWh of electricity.\nPurpose:\n\nThe solar power system could be installed for various reasons:\nTo reduce energy bills by using clean solar energy.\nTo support sustainability goals, reduce carbon emissions, and make the building or facility more energy-efficient.\nTo provide backup power or support the grid, especially in commercial or industrial settings.\nBenefits of a 10 kW Solar System:\nReduced Electricity Costs: By producing energy from the sun, the system reduces reliance on grid power, thus lowering electricity bills over time.\nEnvironmental Impact: The system helps reduce carbon footprints by utilizing renewable energy instead of fossil fuels.\nIncreased Property Value: Properties with solar installations are often valued higher due to the long-term savings on energy costs.\nGovernment Incentives: Depending on the region, there may be tax credits, subsidies, or incentives available for installing solar energy systems.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"14 600",
"18 250 kwh",
"commercial building",
"commercial facility",
"good sunlight",
"largescale installation",
"grid power",
"longterm savings",
"average depending",
"10 kw system",
"common wattage",
"10 kilowatts kw",
"power output",
"solar installations",
"solar irradiance",
"solar system",
"electricity purpose",
"producing energy",
"energy output",
"solar panels",
"solar power system",
"highefficiency solar panels",
"system reduces reliance",
"systems total capacity",
"clean solar energy",
"provide backup power",
"m3muniversal power team",
"lowering electricity bills",
"utilizing renewable energy",
"reduce energy bills",
"reduce energy costs",
"tax credits subsidies",
"valued higher due",
"time environmental impact",
"industrial settings benefits",
"local weather conditions",
"specific information m3m",
"m3m key details"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 230,
"imageuri": "https://bizimages.withfloats.com/actual/1313f8f1b9074854b81e45cc2e194064.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/1313f8f1b9074854b81e45cc2e194064.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-15T07:45:16.544Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/10-kw-solar-system-installed-at-m3m/230",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "10 kW solar system installed at M3M",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67d50f00b061379720e92a7c",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Vertiv Liebert PS15 UPS",
"description": "The Vertiv Liebert PS15 UPS is a model of Uninterruptible Power Supply (UPS) designed to provide reliable power protection for various types of critical equipment, such as servers, networking devices, and other essential electronics. Here's a general overview of its key features:\n\nKey Features:\nPower Capacity: The Liebert PS15 typically offers a 15kVA (kilovolt-ampere) power capacity, making it suitable for medium to large-sized IT and data center applications.\n\nForm Factor: It's available in both tower and rack-mounted configurations, providing flexibility in installation based on the user's space requirements.\n\nTrue Online Double-Conversion Technology: The UPS employs a double-conversion topology, which provides continuous, clean power to connected devices by isolating them from input power fluctuations, ensuring consistent voltage output.\n\nHigh Efficiency: The Liebert PS15 often features advanced efficiency modes to reduce energy consumption, particularly in non-critical load conditions.\n\nScalability: Some models in this series can be expanded with external battery cabinets, providing longer backup runtimes when needed.\n\nMonitoring & Management: Equipped with advanced monitoring options, the UPS can be connected to networked management systems, offering remote monitoring, control, and alerting for efficient power management.\n\nBattery Technology: The unit uses valve-regulated lead-acid (VRLA) or lithium-ion batteries, depending on the configuration. VRLA batteries are the most common, though lithium-ion options may offer longer lifespan and better energy density.\n\nInput and Output Voltage: The UPS typically supports a wide input voltage range and provides stable 208V/400V output, depending on the model configuration.\n\nSafety Features: Includes built-in surge protection, overload protection, and short-circuit protection for both the unit and connected equipment.\n\nApplications:\nIT Infrastructure: Ideal for protecting servers, storage devices, and networking equipment in small and medium-sized data centers.\nTelecommunication: Provides power protection for critical telecommunications equipment.\nHealthcare: Ensures that sensitive medical equipment continues to operate without interruption.\nManufacturing and Industrial: Often used in industries where downtime due to power failure is not an option.\nMaintenance and Support:\nVertiv offers various support options for its UPS systems, including extended warranties, remote diagnostics, and on-site service.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"onsite service",
"ups systems",
"option maintenance",
"downtime due",
"interruption manufacturing",
"infrastructure ideal",
"shortcircuit protection",
"output voltage",
"liebert ps15",
"doubleconversion topology",
"ups employs",
"installation based",
"general overview",
"power failure",
"power protection",
"critical equipment",
"connected devices",
"support options",
"networking equipment",
"lithiumion options",
"connected equipment applications",
"ups typically supports",
"servers networking devices",
"advanced monitoring options",
"continuous clean power",
"support vertiv offers",
"lithiumion batteries depending",
"energy density input",
"offer longer lifespan",
"configuration vrla batteries",
"valveregulated leadacid vrla",
"reduce energy consumption",
"essential electronics heres"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 223,
"imageuri": "https://bizimages.withfloats.com/actual/a7fed41ecb6c45a2ad8953b185ca21a7.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/a7fed41ecb6c45a2ad8953b185ca21a7.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-15T05:24:16.298Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-liebert-ps15-ups/223",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Vertiv Liebert PS15 UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67cc1c587f3394e301d56525",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "VERTIV 2KVA UPS",
"description": "The Vertiv 2KVA UPS models, such as the GXT-2000RTPLUSG230 and GXT5-2000LVRT2UXL, offer robust specifications for reliable power protection. Key features include a capacity of 2000 VA/1800 W, input voltage ranges of 120V or 230V, and advanced double-conversion technology for consistent output.\n\nFor detailed specifications, you can refer to the following models:\n\nGXT-2000RTPLUSG230:\n\nCapacity: 2000 VA\nInput Voltage: 230V\nOutput Voltage: 230V\nPhase: Single phase with ground\nTechnical Specifications\nGXT5-2000LVRT2UXL:\n\nCapacity: 2000 VA / 1800 W\nInput Voltage: 120V (range: 60-150V)\nOutput Voltage: Configurable (110/115/120/125VAC)\nProduct Overview\nGXT5LI-2000LVRT2UXL:\n\nLithium-Ion technology for longer battery life\nStandard 5-year warranty\nProduct Details\nThese models are designed for critical applications, ensuring uninterrupted power supply and protection against outages.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"2000 va1800",
"detailed specifications",
"consistent output",
"advanced doubleconversion technology",
"input voltage ranges"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 208,
"imageuri": "https://bizimages.withfloats.com/actual/7a687f4a9c4f4a9683211e0e32addcae.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/7a687f4a9c4f4a9683211e0e32addcae.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-08T10:30:48.828Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-2kva-ups/208",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "VERTIV 2KVA UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67cbe2de3f4d3b4e411168be",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "AMARON QUANTA 12V 46Ah BATTERY",
"description": "The AMARON 12V 46Ah battery is a reliable sealed lead-acid battery designed for various applications, including automotive and renewable energy systems. It typically features a nominal voltage of 12V, a capacity of 46Ah, and is known for its durability, low maintenance, and ability to perform well in diverse environmental conditions.\n\n Product Overview\n\nType: Sealed Lead Acid (SLA) Battery\nNominal Voltage: 12V\nCapacity: 46Ah\nWeight: Approximately 12-13 kg (varies by model)\nDimensions: Typically around 9.1 x 5.4 x 8.5 inches (L x W x H)\nKey Features\n\nDurability:\n\nDesigned to withstand harsh conditions and vibrations.\nLong service life with proper maintenance.\nMaintenance:\n\nLow maintenance requirements; sealed design prevents electrolyte loss.\nRequires periodic checks for optimal performance.\nPerformance:\n\nExcellent deep cycle capabilities, suitable for applications requiring sustained power.\nGood discharge characteristics, providing reliable power output.\nApplications\n\nAutomotive:\n\nIdeal for use in cars, trucks, and other vehicles.\nSuitable for starting, lighting, and ignition (SLI) applications.\nRenewable Energy:\n\nCan be used in solar energy systems for energy storage.\nEffective in off-grid applications and backup power systems.\nWarranty and Standards\n\nWarranty:\n\nTypically comes with a warranty period of 12-18 months, depending on the retailer.\nCertifications:\n\nComplies with international safety and performance standards.\nCharging and Maintenance\n\nCharging Voltage:\n\nRecommended charging voltage is around 14.4V to 14.8V.\nCharging Method:\n\nCan be charged using standard lead-acid battery chargers.\nAvoid overcharging to extend battery life.\nEnvironmental Considerations\n\nOperating Temperature:\nPerforms well in a wide range of temperatures, typically from -20°C to +50°C.\nEnsure proper ventilation during charging to prevent gas buildup.\nThis battery is a versatile choice for users looking for a dependable power source across various applications.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"85 inches",
"offgrid applications",
"versatile choice",
"wide range",
"international safety",
"1218 months depending",
"starting lighting",
"vehicles suitable",
"cars trucks",
"nominal voltage",
"temperatures typically",
"warranty period",
"typically features",
"standards warranty typically",
"148v charging method",
"performance standards charging",
"model dimensions typically",
"dependable power source",
"prevent gas buildup",
"retailer certifications complies",
"energy storage effective",
"solar energy systems",
"withstand harsh conditions",
"durability low maintenance",
"renewable energy systems"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 204,
"imageuri": "https://bizimages.withfloats.com/actual/6f561e8096144491892a2f868270d0c7.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/6f561e8096144491892a2f868270d0c7.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-08T06:25:34.105Z",
"updatedon": "0001-01-01T00:00:00Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-46ah-battery/204",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "AMARON QUANTA 12V 46Ah BATTERY",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67ca8ebc824951898085414a",
"fptag": "UNIVERSALPOWERSYSTEMF82C",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "VERTIV 40kVA UPS",
"description": "The Vertiv 40kVA UPS models, such as the Liebert ITA and EXS series, offer robust power protection for critical applications. They feature a power capacity of 40 kVA, double conversion technology, and options for both three-phase and single-phase outputs, ensuring reliable performance and flexibility in installation.\n\nKey Specifications:\n\nPower Capacity: 40 kVA (40 kW).\nInput Voltage Range: Typically 176 V AC - 288 V AC.\nOutput Voltage: Configurable options, often 208V or 220V.\nForm Factor: Available in rack or tower configurations.\nEfficiency: High efficiency ratings, often exceeding 95%.\nCommunication: Equipped with Vertiv IntelliSlot for SNMP, Modbus, or Relay communication.\nBattery Type: Generally uses lead-acid batteries with options for extended runtime.\nApplications: Ideal for data centers, telecommunications, and other critical infrastructure requiring uninterrupted power supply.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"ac 288",
"leadacid batteries",
"snmp modbus",
"vertiv intellislot",
"power capacity",
"critical applications",
"liebert ita",
"data centers telecommunications",
"220v form factor"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 194,
"imageuri": "https://bizimages.withfloats.com/actual/b313d751accf49d091805528bd1aaf14.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/b313d751accf49d091805528bd1aaf14.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-03-07T06:14:20.233Z",
"updatedon": "2025-03-07T06:14:43.505Z",
"buyonlinelink": null,
"producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-40kva-ups/194",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "40kVA UPS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}