Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

UNIVERSALPOWERSYSTEMF82C 6543468cae4e1df6fbef3986 Products https://locations.universalpower.co.in/bhiwadi
{ "products": [ { "_id": "67d7f3c9475a519de5e6884b", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Quanta 12V 18Ah Battery", "description": "The Amaron Quanta 12V 18Ah is a type of sealed lead-acid (SLA) battery, commonly used for backup power applications, such as in UPS systems, inverters, and other critical power supply systems. Here's a detailed breakdown of its specifications and features:\n\n1. General Overview\nBrand: Amaron Quanta\nBattery Type: Sealed Lead-Acid (SLA) Battery\nVoltage: 12 Volts (V)\nCapacity: 18 Ampere-Hours (Ah)\n2. Key Features\nLonger Battery Life: Amaron Quanta batteries are designed for long-lasting performance and high reliability. They typically offer a good lifespan, especially in applications with a low depth of discharge (DOD).\nMaintenance-Free: The battery is sealed, so it doesn’t require regular maintenance (e.g., adding water).\nVibration Resistance: These batteries are designed to withstand vibrations, making them ideal for use in environments like telecoms, solar power, and UPS systems.\nWide Operating Temperature: They can operate in a wide range of temperatures, typically from 0°C to 40°C, making them versatile for use in different climates.\n3. Technical Specifications\nVoltage: 12V (Nominal)\nCapacity: 18Ah (Ampere-Hours)\nDimensions:\nLength: 181 mm\nWidth: 77 mm\nHeight: 167 mm\nWeight: Around 5.2 to 5.5 kg (varies slightly based on exact model)\nCharge Voltage: 14.4V to 15.0V (during charging)\nDischarge Voltage: Typically 10.5V to 11.0V for complete discharge\nSelf-discharge: Less than 3% per month at 25°C\n4. Applications\nUPS Systems: The 12V 18Ah battery is widely used in smaller uninterruptible power supplies (UPS) for providing backup power to sensitive electronics.\nInverters: It can also be used in small-scale inverters to provide backup power to homes or offices.\nTelecommunications: In telecom applications, these batteries can be used for backup power to critical network equipment.\nSolar Energy Storage: Sometimes used in small-scale solar energy systems for storing energy for use during off-sunlight hours.\n5. Battery Design Features\nValve Regulated Lead-Acid (VRLA): The Amaron Quanta battery uses VRLA technology, which means the battery is sealed and uses a valve to release gas in case of overpressure.\nDeep Cycle: Designed for regular deep discharge cycles, making it suitable for power backup applications where batteries frequently discharge.\nAbsorbent Glass Mat (AGM): Some models use AGM technology, where the electrolyte is absorbed in a fiberglass mat, allowing the battery to be spill-proof and leak-proof.\n6. Charge/Discharge Characteristics\nCharging: Amaron Quanta batteries typically use a constant voltage charge, with a float charge voltage of around 13.5V to 13.8V.\nDischarge: The battery can typically discharge down to around 10.5V under load, but frequent deep discharges can reduce the battery's overall lifespan.\n7. Advantages\nLonger Service Life: Typically offers a long life when maintained and used properly, making it a cost-effective option for long-term use.\nReliable Performance: Known for reliability in maintaining charge over time, especially in demanding environments.\nEnvironmentally Friendly: Sealed and maintenance-free design minimizes risks associated with acid leakage and spills.\n8. Maintenance\nMaintenance-Free Design: As mentioned, the battery is sealed, so it doesn't require regular maintenance like adding distilled water. However, regular inspection for corrosion on terminals and proper charge maintenance is recommended.\nCharging Recommendations: Always charge the battery in accordance with the manufacturer’s recommendations. Overcharging or undercharging can significantly reduce the battery’s lifespan.\n9. Warranty\nAmaron Quanta batteries often come with a warranty that covers defects in material or workmanship, which typically lasts for 1 to 2 years depending on the seller and country-specific terms.\n10. Compatibility\nCompatible Devices: The Amaron Quanta 12V 18Ah battery is commonly used in small UPS systems, solar power applications, and other critical systems where consistent backup power is required.\nCharging Systems: Can be used with most standard 12V chargers designed for SLA or AGM batteries.\nConclusion\nThe Amaron Quanta 12V 18Ah battery is an ideal solution for users looking for a reliable, low-maintenance, and efficient power backup option in smaller systems. It is widely used in UPS systems, inverters, and telecommunications applications where it can provide critical backup power when needed.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "ideal solution", "significantly reduce", "high reliability", "reliable lowmaintenance", "2 years depending", "typically lasts", "covers defects", "regular inspection", "acid leakage", "reliable performance", "costeffective option", "long life", "release gas", "vrla technology", "storing energy", "offices telecommunications", "temperatures typically", "wide range", "low depth", "good lifespan", "typically offer", "longlasting performance", "detailed breakdown", "telecommunications applications", "telecom applications", "properly making", "40c making", "maintaining charge", "typically discharge", "138v discharge", "agm technology", "smaller systems", "critical systems", "smallscale inverters", "backup power", "agm batteries conclusion", "amaron quanta battery", "12v 18ah battery", "power backup applications", "backup power applications", "withstand vibrations making", "ups systems inverters", "proper charge maintenance", "float charge voltage", "constant voltage charge", "complete discharge selfdischarge", "discharge dod maintenancefree", "required charging systems", "consistent backup power", "provide backup power", "providing backup power", "sensitive electronics inverters", "telecoms solar power", "manufacturers recommendations overcharging", "recommended charging recommendations", "adding distilled water", "frequent deep discharges", "fiberglass mat allowing" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 234, "imageuri": "https://bizimages.withfloats.com/actual/9059f3fdb01f46969d81870658739ec7.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/9059f3fdb01f46969d81870658739ec7.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-17T10:04:57.372Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-18ah-battery/234", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Amaron Quanta 12V 18Ah Battery", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67de50f12d762c4c27178365", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Quanta 12v 42Ah Battery", "description": "The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial.\n\nKey Features of Amaron Quanta 42Ah Battery:\nCapacity:\n\n42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load.\n\nTechnology:\n\nMaintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free.\n\nHigh Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter.\n\nDeep Cycle Battery:\n\nThis is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently.\n\nDurability:\n\nLong Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored.\n\nHigh-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions.\n\nDesign:\n\nCompact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern.\n\nVibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings.\n\nSafety Features:\n\nFlame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction.\n\nLeak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety.\n\nApplication Areas:\n\nUPS Systems: Provides backup power to computers, servers, and networking equipment.\n\nInverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages.\n\nSolar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night.\n\nWarranty:\n\nThe Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details.\n\nGeneral Specifications:\nVoltage: 12V (standard for most UPS and inverter batteries).\n\nCapacity: 42Ah.\n\nType: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat).\n\nCharging Voltage: Typically around 14.4 to 15.0V for 12V batteries.\n\nNominal Voltage: 12V.\n\nDimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model).\n\nWeight: Approximately 12-14 kg.\n\nMaintenance Tips for the Amaron Quanta 42Ah Battery:\nRegular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan.\n\nStorage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically.\n\nClean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed.\n\nAvoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it.\n\nCheck for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear.\n\nBattery Testing:\nTo check the health of the Amaron Quanta 42Ah battery, you can follow these steps:\n\nVoltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V.\n\nLoad Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation.\n\nCapacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold.\n\nConclusion:\nThe Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 249, "imageuri": "https://bizimages.withfloats.com/actual/1d085d444be04b38886a66b6877f7848.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/6ffad887d34b4ebd8fcc808aeb3d9a29.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-22T05:56:01.145Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-42ah-battery/249", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Amaron Quanta 12v 42Ah Battery", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67de4bd9042ffb8bd0390aa7", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Powerstack battery Testing ", "description": "Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition:\n\nSteps to Test Powerstack Batteries:\n1. Visual Inspection\nCheck for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced.\n\nClean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water.\n\n2. Check Battery Voltage\nMeasure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts.\n\nFor a 24V battery, you should see a voltage of around 25.2 to 26.0 volts.\n\nUndercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty.\n\n3. Load Testing\nTest under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak.\n\nDC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff.\n\n4. Battery Charge Test\nCharge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size.\n\nMonitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger.\n\nEnd of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery.\n\n5. Conduct a Specific Gravity Test (for Lead-Acid Batteries)\nHydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty.\n\n6. Perform a Battery Health Check (Advanced)\nUse a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs.\n\nInternal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life.\n\n7. Monitor for Temperature\nBatteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system.\n\nSigns of a Failing Battery:\nRapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating.\n\nShort Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life.\n\nInconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery.\n\nPhysical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced.\n\nBattery Maintenance Tips:\nRegular Charging: Avoid deep discharges and always keep the battery charged.\n\nEnvironmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures.\n\nPeriodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly.\n\nUse the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging.\n\nConclusion:\nBattery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 248, "imageuri": "https://bizimages.withfloats.com/actual/7f2c78a976e246efbe70882f742a421a.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/f8db1555dfa447dbb73d3446e6b45940.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-22T05:34:17.551Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/powerstack-battery-testing-/248", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Powerstack battery Testing ", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d5328fdb7fc0f04f83af80", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Battery Replacement In Faridabad", "description": "Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each.\n\nTypes of Batteries and Their Replacement Process\n1. Lead-Acid Batteries\nCommon Types:\nFlooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells.\nSealed Lead-Acid (SLA): Maintenance-free and does not require water addition.\nAbsorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats.\nGel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications.\nReplacement Process:\nTurn off the system: Ensure the system is powered off, and disconnect it from the grid or load.\nSafety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases.\nDisconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal.\nRemove old batteries: Lift and remove the batteries carefully, especially if they're heavy.\nClean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water.\nInstall new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system and check the voltage and charging status.\nMaintenance Tips:\nRegularly check the electrolyte levels in flooded batteries.\nClean terminals and ensure the battery box or tray is secure.\n2. Lithium-Ion Batteries\nCommon Types:\nLithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan.\nLithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools.\nLithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications.\nLithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones.\nReplacement Process:\nTurn off the system: Disconnect the power source or system.\nSafety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage.\nDisconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal.\nRemove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries.\nInstall the new battery: Place the new battery in the same orientation and secure it.\nReconnect terminals: Attach the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly.\nMaintenance Tips:\nLithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range.\nBattery Management System (BMS) should be monitored to ensure proper functioning and safety.\n\nConclusion:\nBattery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation.\n\nLead-acid batteries need regular maintenance, especially flooded types.\nLithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance.\nAlways follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "system disconnect", "common types", "system ensure", "replacement process", "battery place", "battery box", "electrolyte levels", "gel electrolyte", "sla battery", "battery replacement", "system power", "handling batteries", "longer lifespan", "batterys charging", "typically lighter", "handled carefully", "generally safe", "small devices", "highpower applications", "high efficiency", "evs due", "batteries place", "baking soda", "batteries carefully", "batteries lift", "sulfuric acid", "ill provide", "vary depending", "batterypowered devices", "faridabadbattery replacement", "minimal maintenance", "regular maintenance", "power source", "leadacid batteries", "power systems", "solar systems", "positive terminal", "water install", "negative terminal", "battery lithiumion batteries", "leadacid batteries install", "reconnect terminals attach", "positive terminal remove", "solar systems leadacid", "evs power tools", "negative terminal check", "common maintenance task", "installation leadacid batteries", "ensure proper recycling", "ensure proper functioning", "drones power banks", "adding distilled water", "avoid environmental hazards", "follow safety guidelines", "requiring specific attention", "avoid overheating shortcircuiting" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 231, "imageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-15T07:55:59.544Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/battery-replacement-in-faridabad/231", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Battery Replacement In Faridabad", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d52a2079019484efe3a8ff", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Quanta 12V 130Ah Battery In Bhiwadi", "description": "The Amaron Quanta 12V 130Ah batteries are lead-acid batteries typically used for solar power storage, backup power systems, and other applications that require reliable energy storage. Here's a detailed overview of this battery:\n\nKey Features of Amaron Quanta 12V 130Ah Battery:\nBattery Type:\n\nLead-Acid: This is a type of flooded or sealed (VRLA) lead-acid battery, suitable for deep cycle applications.\n12V System: Designed for systems that operate on a 12V DC supply, often used in small-scale solar energy systems, inverters, and backup power setups.\nCapacity:\n\n130Ah (Ampere-hour): This indicates the battery’s storage capacity. It means the battery can deliver 130 amps for 1 hour or 1 amp for 130 hours at a nominal voltage of 12V.\nFor example, if the system uses 1A of current, the battery will last for around 130 hours before needing a recharge.\nApplications:\n\nSolar Power Systems: To store energy generated by solar panels.\nUPS (Uninterruptible Power Supply): Provides backup during power outages.\nOff-Grid Systems: Stores energy for homes or businesses in remote areas.\nElectric Vehicles and RVs: Sometimes used for backup and auxiliary power.\nCharging and Discharging:\n\nCharging: The battery can be charged through solar panels, inverters, or a regular charger. It is recommended to avoid deep discharges to extend the battery life.\nDischarging: It should not be discharged fully for longevity. Typically, a depth of discharge (DoD) of 50% to 70% is ideal for long-term use.\nBattery Life:\n\nCycle Life: Typically, a lead-acid battery like the Amaron Quanta 12V 130Ah can last around 3-5 years, depending on usage and maintenance.\nProper charging and maintenance (like keeping the terminals clean and ensuring adequate ventilation) can improve the lifespan of the battery.\nAdvantages:\n\nReliable and Cost-Effective: Lead-acid batteries are typically less expensive than other types of batteries, like lithium-ion.\nWidely Available: Amaron is a well-known brand, and their batteries are widely available and easy to replace.\nMaintenance:\n\nFlooded Lead-Acid: If it’s a flooded type, you may need to periodically check the water levels and top up with distilled water.\nVRLA (Valve-Regulated Lead-Acid): If it's a sealed type, it requires less maintenance as it’s sealed and does not need water refills.\nSpecifications:\n\nVoltage: 12V\nCapacity: 130Ah\nWeight: Around 40-45 kg (approx.), depending on the specific model and construction type.\nDimensions: Varies by model, but typically it is about 410mm (L) x 175mm (W) x 240mm (H).\nConclusion:\nThe Amaron Quanta 12V 130Ah battery is a good choice for off-grid solar systems, backup power applications, or any system requiring long-lasting energy storage. It offers a solid balance of performance, cost-effectiveness, and reliability. Proper care and maintenance will ensure it provides reliable service for years to come.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "130 hours", "1 amp", "1 hour", "sealed type", "flooded type", "specific model", "lithiumion widely", "35 years depending", "longevity typically", "performance costeffectiveness", "solid balance", "good choice", "water levels", "periodically check", "wellknown brand", "terminals clean", "discharge dod", "discharged fully", "regular charger", "nominal voltage", "deliver 130 amps", "detailed overview", "reliable service", "leadacid battery", "discharging charging", "leadacid batteries typically", "maintenance proper charging", "battery advantages reliable", "battery life discharging", "costeffective leadacid batteries", "12v dc supply", "battery key features", "auxiliary power charging", "reliability proper care", "ensuring adequate ventilation", "avoid deep discharges", "solar panels inverters", "store energy generated", "batterys storage capacity" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 227, "imageuri": "https://bizimages.withfloats.com/actual/ba8dda1eb6ab4cf2a1abfcc8de098663.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/ba8dda1eb6ab4cf2a1abfcc8de098663.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-15T07:20:00.489Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-130ah-battery-in-bhiwadi/227", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Amaron Quanta 12V 130Ah Battery In Bhiwadi", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67ca9cb25716f22e86601481", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "All Types Of Ups & Batteries Repair And Maintenance Of Ups", "description": "Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices.\n\nTypes of UPS Systems\nOffline/Standby UPS:\n\nDescription: Provides basic protection; switches to battery during a power outage.\nMaintenance: Regular battery checks and replacement every 3-5 years.\nLine-Interactive UPS:\n\nDescription: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations.\nMaintenance: Inspect and test the battery and inverter regularly; check for dust accumulation.\nOnline Double-Conversion UPS:\n\nDescription: Provides continuous power and isolates equipment from power issues.\nMaintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates.\nModular UPS:\n\nDescription: Scalable systems that allow for adding or removing modules based on power needs.\nMaintenance: Regular checks on each module, ensuring proper connections and functionality.\nTypes of Batteries Used in UPS\nLead-Acid Batteries:\n\nTypes: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel.\nMaintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity.\nLithium-Ion Batteries:\n\nDescription: Increasingly used due to longer life and lighter weight.\nMaintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates.\nNickel-Cadmium (NiCd) Batteries:\n\nDescription: Used in specific applications; known for durability.\nMaintenance: Regularly test for capacity and perform equalization charging.\nRepair and Maintenance Practices\n1. Routine Inspections\nVisual Checks: Inspect for physical damage, corrosion, or loose connections.\nEnvironmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity).\n2. Battery Maintenance\nTesting: Conduct regular load tests and capacity tests to assess battery health.\nCleaning: Clean terminals and connections to prevent corrosion.\nReplacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid).\n3. UPS Maintenance\nFirmware Updates: Keep the UPS firmware updated for optimal performance.\nComponent Checks: Inspect capacitors, fans, and other internal components for wear and tear.\nCooling System: Ensure that cooling fans are operational and that vents are not blocked.\n4. Emergency Procedures\nTesting: Regularly test the UPS under load conditions to ensure it functions correctly during an outage.\nDocumentation: Maintain records of all maintenance activities, repairs, and battery replacements.\n5. Professional Servicing\nScheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS.\nEmergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts.\nConclusion\nRegular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries.\n\nFor specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "35 years", "capacity tests", "functionality types", "tailored solutions", "significantly extend", "timely repairs", "rapid response", "comprehensive inspections", "functions correctly", "load conditions", "cooling fans", "internal components", "longer life", "continuous power", "comprehensive overview", "ups failures", "complex systems", "ups systems", "specific applications", "performance check", "isolates equipment", "ups batteries repair", "ups systems batteries", "maintenance practices types", "maintenance activities repairs", "power issues maintenance", "battery backup ideal", "ups firmware updated", "detailed maintenance plans", "specific service providers", "structured maintenance schedule", "protecting sensitive equipment", "maintenance regular checks", "inverter regularly check", "engaging professional services", "manufacturer recommendations typically", "physical damage corrosion", "removing modules based", "basic protection switches" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 202, "imageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-07T07:13:54.328Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/all-types-of-ups-batteries-repair-and-maintenance-of-ups/202", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "All Types Of Ups & Batteries Repair And Maintenance Of Ups", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6729bcedeb4a7854cab11753", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Quanta 12V 12Ah battery In Sector 95 Bhiwadi", "description": "The Amaron Quanta 12V 12Ah battery is part of Amaron's lineup of high-performance lead-acid batteries, designed for various applications including uninterruptible power supply (UPS) systems, solar energy storage, and other backup power requirements. Here are the key details and specifications of the Amaron Quanta 12V 12Ah battery:\n\n\n1. General Specifications:\nModel: Amaron Quanta 12V 12Ah\nVoltage: 12V (nominal)\nCapacity: 12Ah (Ampere-hours)\nChemistry: Lead-Acid (Flooded or VRLA - Valve Regulated Lead Acid, depending on the specific model variant)\nType: Sealed Lead Acid (SLA) or VRLA (Valve-Regulated Lead Acid)\n2. Dimensions:\nLength: Approximately 151 mm\nWidth: Approximately 65 mm\nHeight: Approximately 94 mm\nWeight: Approximately 3.8 kg (8.38 lbs)\n3. Applications:\nUPS Systems: Ideal for providing backup power to critical systems like computers, telecom equipment, and other sensitive electronics.\nSolar Energy Storage: Can be used in solar applications to store excess energy for later use.\nElectric Vehicles: Sometimes used in smaller electric vehicle or mobility scooter systems.\nAlarm and Security Systems: Provides backup power to alarm systems, CCTV, and other security devices.\nEmergency Lighting: Often used in emergency lighting setups for buildings, factories, and other premises.\n4. Performance Features:\nCycle Life: The Amaron Quanta 12V 12Ah battery generally offers around 300-500 charge/discharge cycles (varies based on usage, charge/discharge depth, and environmental conditions).\nDischarge Current: Able to provide a high discharge current (depending on load), making it suitable for short-term high-power loads.\nRecharge Time: Typically around 6-8 hours for a full recharge from full discharge, but this can vary depending on the charger and charging conditions.\nSelf-Discharge Rate: Low self-discharge rate, meaning it holds charge for a long period when not in use.\n5. Key Features:\nHigh Reliability: Designed for reliable performance, making it a trusted option for various backup power systems.\nSafety: Valve-Regulated Lead-Acid (VRLA) design, meaning it is sealed and maintenance-free under normal operating conditions.\nDurability: Offers robust construction for longer-lasting performance even under challenging environmental conditions.\nLeak-Proof Design: The VRLA design ensures that the battery is leak-resistant, which is particularly important for use in enclosed spaces.\nLow Maintenance: Does not require regular water refilling like traditional flooded lead-acid batteries.\n6. Charging Voltage and Current:\nFloat Voltage: Around 13.5V to 13.8V.\nCharge Voltage (Bulk): Typically around 14.4V to 14.7V (depending on the charger and temperature).\nCharge Current: Around 0.1C to 0.3C (for a 12Ah battery, this translates to a charge current of about 1.2A to 3.6A).\n7. Temperature Range:\nOperating Temperature: Generally from -15°C to 50°C, but the optimal temperature range for performance is usually between 20°C to 25°C.\nStorage Temperature: For best longevity, store the battery at temperatures between 15°C to 25°C.\n8. Warranty:\nWarranty Period: Amaron Quanta batteries typically come with a warranty period of 1-2 years, depending on the region and specific seller's terms.\n9. Advantages:\nCost-Effective: Amaron Quanta batteries are considered affordable yet reliable for various low to medium capacity backup systems.\nWide Availability: These batteries are widely available in many regions and are popular due to their reputation for consistent performance.\nMaintenance-Free: VRLA technology means no need for regular maintenance, unlike flooded batteries.\n10. Safety Considerations:\nVentilation: While sealed, it's important to ensure that the battery is placed in a well-ventilated area to prevent the buildup of gases.\nAvoid Deep Discharge: Like most lead-acid batteries, it is not recommended to discharge the battery below 50% of its total capacity frequently, as this can shorten its lifespan.\nProper Charging: Always use a proper charger designed for lead-acid batteries, as improper charging can lead to overcharging or undercharging, which will reduce battery life.\n11. Comparison with Other Batteries:\nCompared to other 12V 12Ah batteries, the Amaron Quanta typically offers good cycle life, consistent performance, and a strong reputation for reliability. It is one of the more affordable options in its class, which makes it a good choice for cost-conscious consumers looking for backup power.\nConclusion:\nThe Amaron Quanta 12V 12Ah is a reliable and efficient lead-acid battery suitable for a variety of applications, from backup power systems to solar storage. It offers robust performance, minimal maintenance, and a reasonable lifespan with proper care. It's an excellent choice if you're looking for a cost-effective power solution for home or small business applications.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 142, "imageuri": "https://bizimages.withfloats.com/actual/4c19ae88e25940edb05cece0c6041280.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/4c19ae88e25940edb05cece0c6041280.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-11-05T06:36:29.122Z", "updatedon": "2024-11-05T06:36:29.122Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-12v-12ah-battery-in-sector-95-bhiwadi/142", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Battery", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6729aac1174715dbab62679f", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Quanta 12V 7Ah Battery In Bhogipur Sonipat", "description": "The Amaron Quanta 12V 7Ah is a sealed lead-acid (SLA) battery commonly used in applications such as backup power systems, uninterruptible power supplies (UPS), security systems, and various other low-power applications. Here\\'s a breakdown of its details:\nKey Specifications:\nNominal Voltage:\n\n12 Volts (V)\nCapacity:\n\n7 Ampere-hours (Ah) at a rate of 20 hours (i.e., the battery can provide 0.35A of current for 20 hours).\nThis is typical for deep-cycle applications, providing reliable performance over an extended period.\nBattery Type:\n\nSealed Lead-Acid (SLA):\nMaintenance-free design.\nCan be installed in any orientation, though upright is recommended for optimal performance.\nSuitable for both float and cyclic applications.\nDimensions:\n\nLength: 151 mm (5.94 inches)\nWidth: 65 mm (2.56 inches)\nHeight: 95 mm (3.74 inches)\nWeight: Approx. 2.3 kg (5.07 lbs)\nTerminal Type:\n\nF1 Faston connectors (0.187” wide), which are commonly used for quick connections.\nOperating Temperature:\n\nDischarge: -15°C to +50°C (5°F to 122°F)\nCharge: 0°C to +40°C (32°F to 104°F)\nFloat Life:\n\nTypically 3-5 years in float (backup power) applications.\nSelf-Discharge:\n\nSLA batteries typically have a low self-discharge rate of about 3-5% per month at 25°C, meaning they retain their charge relatively well when not in use for extended periods.\nCharge Voltage:\n\nStandard Charging Voltage: 13.5 to 13.8V (constant voltage charging)\nMaximum Charging Voltage: 14.4V\nRecommended Float Charging Voltage: 13.5V\nCycle Life:\n\nTypically offers about 200-300 cycles at 100% discharge.\nThe cycle life increases with lower depth of discharge (DoD).\nApplications:\nUPS Systems: To provide backup power for computers, networking equipment, and other devices.\nSolar Power Systems: As a small energy storage option in off-grid or backup solar systems.\nAlarm Systems: For providing power in case of a mains failure.\nElectric Vehicles & Mobility Scooters: In some cases for small EVs or battery-powered mobility solutions.\nPower Tools & Other Low Power Systems: To provide compact, reliable energy for tools and other devices.\nSafety & Maintenance:\nMaintenance-Free: No need to add water or maintain the electrolyte levels, as the battery is sealed.\nOvercharge Protection: Built-in mechanisms to prevent overcharging that could lead to damage or overheating.\nOvercurrent Protection: Built-in to prevent damage due to short circuits or excessive current.\nWarranty:\nTypically 1-2 years depending on the brand and country of purchase.\nStorage & Handling:\nStorage Temperature: Store in a cool, dry place, ideally between 15°C and 25°C.\nDo not store in a fully discharged state, as this can significantly reduce the lifespan of the battery.\nRegular Maintenance: If not in use for extended periods, check the battery voltage periodically and recharge it if necessary.\nThe Amaron Quanta 12V 7Ah battery is designed for reliability and versatility, suitable for a variety of applications that require backup power or a small energy storage solution.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "95 mm", "65 mm", "2.3 kg", "151 mm", "20 hours", "12 Volts", "1-2 years", "3-5 years", "small EVs", "Float Life", "lower depth", "Power Tools", "UPS Systems", "SLA) battery", "Battery Type", "SLA batteries", "mains failure", "Terminal Type", "Alarm Systems", "other devices", "5V Cycle Life", "100% discharge", "7 Ampere-hours", "Charge Voltage", "short circuits", "200-300 cycles", "extended period", "Nominal Voltage", "battery voltage", "cool, dry place", "sealed lead-acid", "Bhogipur Sonipat", "security systems", "excessive current", "Electric Vehicles", "quick connections", "Mobility Scooters", "electrolyte levels", "Key Specifications", "Regular Maintenance", "cyclic applications", "optimal performance", "Storage Temperature", "Solar Power Systems", "networking equipment", "reliable performance", "backup power systems", "backup solar systems", "F1 Faston connectors", "Overcharge Protection", "Operating Temperature", "Overcurrent Protection", "Float Charging Voltage", "Maintenance-free design", "deep-cycle applications", "low self-discharge rate", "Other Low Power Systems", "Maximum Charging Voltage", "compact, reliable energy", "constant voltage charging", "Standard Charging Voltage", "backup power) applications", "small energy storage option", "small energy storage solution", "uninterruptible power supplies", "The Amaron Quanta 12V 7Ah battery", "battery-powered mobility solutions", "various other low-power applications" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 140, "imageuri": "https://bizimages.withfloats.com/actual/6a737164a93f41b0ad1c485b77f6ef13.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/6a737164a93f41b0ad1c485b77f6ef13.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-11-05T05:18:57.888Z", "updatedon": "2024-11-05T05:18:57.888Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//amaron-quanta-12v-7ah-battery-in-bhogipur-sonipat/140", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Battery", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6720980b2b5881cbadcda4e8", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Repairing And Maintaining UPS In Delhi", "description": "Repairing And Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring the reliability and longevity of the power backup system. Here’s a detailed overview of UPS battery maintenance and repair practices.\n\nUPS Battery Types\nLead-Acid Batteries:\n\nValve-Regulated Lead Acid (VRLA): Maintenance-free and sealed, suitable for most UPS systems.\nFlooded Lead Acid: Requires periodic maintenance and water topping.\nLithium-Ion Batteries:\n\nIncreasingly used due to longer life and higher efficiency but may require specific handling protocols.\nMaintenance Practices\nRegular Inspections:\n\nVisual Check: Inspect batteries for physical damage, corrosion, or leaks. Look for swelling or bulging in case of lead-acid batteries.\nConnections: Ensure all terminals and connections are tight and free of corrosion.\nCleaning:\n\nClean battery terminals with a mixture of baking soda and water to remove corrosion. Rinse with clean water and dry thoroughly.\nBattery Testing:\n\nVoltage Checks: Regularly measure the voltage of each battery to identify weak cells.\nLoad Testing: Perform load tests to ensure the battery can deliver the expected capacity under load conditions.\nTemperature Monitoring:\n\nMonitor battery temperature, especially in environments with high heat, as excessive temperatures can affect battery performance and lifespan.\nElectrolyte Level (for Flooded Batteries):\n\nCheck and maintain the electrolyte levels in flooded lead-acid batteries. Top up with distilled water as necessary.\nBattery Health Monitoring:\n\nUse battery management systems (BMS) for advanced monitoring of battery health, state of charge, and state of health.\nRepair Practices\nIdentifying Faults:\n\nCommon issues include short-circuited cells, sulfation, and capacity loss. Use diagnostic tools to identify problems.\nReplacing Individual Batteries:\n\nIf a battery within a pack fails, replace only the faulty battery if it’s compatible. However, it's often recommended to replace all batteries in a series to ensure uniform performance.\nEqualization Charging (for Flooded Batteries):\n\nPeriodically perform equalization charging to balance the charge across all cells and prevent sulfation.\nReconditioning:\n\nSome lead-acid batteries can be reconditioned through a process of controlled charging and discharging to restore capacity. This is not always successful and should be done by professionals.\nBattery Replacement:\n\nWhen batteries reach the end of their lifespan (typically 3-5 years for lead-acid), replace them with new ones. Ensure that replacements meet the manufacturer's specifications.\nBest Practices for Maintenance\nDocumentation:\n\nKeep records of inspections, tests, and replacements to track battery performance over time.\nEnvironmental Conditions:\n\nMaintain an optimal environment for batteries—ideally, a cool, dry place free from excessive humidity and temperature fluctuations.\nProfessional Servicing:\n\nConsider engaging professionals for complex repairs or maintenance tasks, especially for large or critical UPS systems.\nTraining:\n\nTrain personnel on proper handling, maintenance, and safety procedures related to UPS batteries.\nConclusion\nRegular maintenance and timely repairs of UPS batteries are essential for ensuring the reliability of power backup systems. By implementing best practices, monitoring battery health, and addressing issues promptly, you can prolong the life of your UPS batteries and enhance overall system performance. If you have specific questions or need further details on any aspect, feel free to ask!", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "3-5 years", "high heat", "load tests", "weak cells", "longer life", "baking soda", "clean water", "Load Testing", "Visual Check", "Common issues", "capacity loss", "water topping", "UPS batteries", "Voltage Checks", "timely repairs", "Best Practices", "faulty battery", "Delhi Repairing", "distilled water", "complex repairs", "load conditions", "physical damage", "Battery Testing", "Maintaining UPS", "cool, dry place", "diagnostic tools", "repair practices", "most UPS systems", "expected capacity", "safety procedures", "maintenance tasks", "Electrolyte Level", "higher efficiency", "detailed overview", "Flooded Batteries", "UPS Battery Types", "Flooded Lead Acid", "excessive humidity", "specific questions", "Lead-Acid Batteries", "Regular Inspections", "Regular maintenance", "optimal environment", "Battery Replacement", "battery temperature", "uniform performance", "advanced monitoring", "battery performance", "power backup system", "Individual Batteries", "periodic maintenance", "critical UPS systems", "Equalization Charging", "short-circuited cells", "Lithium-Ion Batteries", "Maintenance Practices", "Professional Servicing", "excessive temperatures", "Temperature Monitoring", "UPS battery maintenance", "Clean battery terminals", "temperature fluctuations", "Environmental Conditions", "Maintenance Documentation", "Battery Health Monitoring", "Valve-Regulated Lead Acid", "battery management systems", "overall system performance", "specific handling protocols", "Uninterruptible Power Supply" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 131, "imageuri": "https://bizimages.withfloats.com/actual/1c0f13c6e9d34936ad199dbe084446a5.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/1c0f13c6e9d34936ad199dbe084446a5.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-29T08:08:43.949Z", "updatedon": "2024-10-29T08:08:43.949Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/repairing-and-maintaining-ups-in-delhi/131", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Repairing And Maintaining UPS", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
recommended charging recommendations?

Still searching for
recommended charging recommendations?

Chat with us