Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

UNIVERSALPOWERSYSTEMF82C 6543468cae4e1df6fbef3986 Products https://locations.universalpower.co.in/bhiwadi
{ "products": [ { "_id": "6718970e453b0f6645adf709", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Vertiv 1kva Ups Repair In Alwar Bhiwadi", "description": "Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems:\n\nRepair Process\nInitial Assessment\n\nGather Information: Document symptoms such as alarms, performance issues, or failure to start.\nVisual Inspection: Look for signs of physical damage, burnt components, or loose connections.\nDiagnosis\n\nSelf-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes.\nMultimeter Testing: Use a multimeter to check voltage levels, current, and resistance.\nBattery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity.\nInspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault.\nCommon Issues\n\nBattery Failure: The most common issue; batteries may need replacement due to age or improper charging.\nCapacitor Issues: Capacitors can degrade over time, leading to performance problems.\nOverheating: Caused by dust accumulation, blocked ventilation, or fan failure.\nControl Board Failures: Issues with the control board can affect functionality.\nInput/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues.\nRepair and Replacement\n\nBattery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity.\nComponent Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics.\nSoldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board.\nFirmware Updates: If applicable, update the firmware for optimal performance.\nTesting After Repair\n\nFunctional Testing: Run the UPS to ensure it operates correctly.\nLoad Testing: Test under load conditions to verify performance and capacity.\nBattery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected.\nFinal Inspection\n\nSafety Checks: Verify that all repairs meet safety standards.\nDocumentation: Record all repairs, parts replaced, and any other relevant information for future reference.\nMaintenance Tips\nRegular Testing: Conduct periodic self-tests and inspections to identify potential issues early.\nBattery Maintenance: Keep battery terminals clean and ensure connections are tight.\nCooling: Ensure proper ventilation around the UPS to prevent overheating.\nEnvironment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures.\nWhen to Seek Professional Help\nIf issues are complex or beyond basic troubleshooting, consult a professional service.\nUse authorized Vertiv service centers for repairs to ensure quality and warranty compliance.\nConclusion\nRepairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 98, "imageuri": "https://bizimages.withfloats.com/actual/76237a5ae75049919100d38e7c2a2aad.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/76237a5ae75049919100d38e7c2a2aad.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-23T06:26:22.4Z", "updatedon": "2024-10-23T06:26:22.4Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-1kva-ups-repair-in-alwar-bhiwadi/98", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "UPS Rental & UPS Repairing Service", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "671894f87b19ca400cddba58", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Vertiv Ups Repairing In Ardee City Gurgaon", "description": "Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations:\n\n\nUPS Repair Process\nInitial Assessment\n\nIdentify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms.\nVisual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections.\nDiagnosis\n\nSelf-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues.\nMultimeter Testing: Measure voltage, current, and resistance to identify electrical issues.\nBattery Testing: Check the health of the batteries using a battery tester or multimeter.\nCheck Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning.\nCommon Issues\n\nBattery Failure: Batteries may need replacement due to age or over-discharge.\nCapacitor Issues: Capacitors can fail due to heat or age, leading to performance issues.\nCooling Problems: Blocked fans or insufficient ventilation can cause overheating.\nControl Board Malfunctions: Issues with the control board can affect the UPS's operation.\nInput/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry.\nRepair and Replacement\n\nBattery Replacement: Remove and replace old batteries with new ones of the same specifications.\nComponent Replacement: Replace faulty capacitors, fuses, or other components as diagnosed.\nResoldering Connections: Fix any broken or loose solder joints on the circuit board.\nSoftware/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance.\nTesting After Repair\n\nFunctional Testing: After repairs, perform a complete functional test of the UPS.\nLoad Testing: Test the UPS under load to ensure it can handle the required capacity.\nBattery Cycle Testing: Run the UPS on battery power to check for proper operation.\nFinal Inspection\n\nSafety Check: Ensure all repairs meet safety standards.\nDocumentation: Document the repairs, parts replaced, and any other relevant information for future reference.\nMaintenance Tips\nRegular Testing: Conduct regular self-tests and inspections to catch issues early.\nBattery Maintenance: Check battery connections and terminals periodically; keep them clean and tight.\nEnvironment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan.\nFirmware Updates: Keep the UPS firmware updated for improved performance and security.\nProfessional Repair Services\nWhen to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional.\nAuthorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs.\nConclusion\nRepairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 97, "imageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-23T06:17:28.889Z", "updatedon": "2024-10-23T06:17:28.889Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-ups-repairing-in-ardee-city-gurgaon/97", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "UPS Repair", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67da5d3df76648ad70e6ba3a", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "ALL TYPES OF UPS REPAIR", "description": "UPS (Uninterruptible Power Supply) repair typically involves diagnosing and fixing issues related to power failures, battery problems, or malfunctioning components. Here are some common repair tasks:\n\nBattery Replacement: Batteries in UPS units degrade over time and may need replacing. This is one of the most common repairs.\n\nPower Supply Issues: Problems with the internal power supply circuit or malfunctioning capacitors can cause a UPS to fail to charge or provide backup power.\n\nOverheating Issues: Dust buildup or fan failure can cause the unit to overheat, requiring cleaning or fan replacement.\n\nInverter and Charger Problems: If the UPS isn't converting DC to AC power properly, it could be an inverter problem. Similarly, charger failures could stop the battery from charging.\n\nInternal Component Replacement: This may involve replacing transformers, fuses, or circuit boards that have failed.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "circuit boards", "charger problems", "malfunctioning capacitors", "malfunctioning components", "fan failure", "ups units degrade", "fan replacement inverter", "ac power properly", "overheat requiring cleaning", "fixing issues related" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 241, "imageuri": "https://bizimages.withfloats.com/actual/fe43ecd841304e5ba3810dfc414a3e94.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/a3c0b54bac9e4d5bb50f465d5334b3f3.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-19T05:59:25.313Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/all-types-of-ups-repair/241", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "ALL TYPES OF UPS REPAIR", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67ca9cb25716f22e86601481", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "All Types Of Ups & Batteries Repair And Maintenance Of Ups", "description": "Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices.\n\nTypes of UPS Systems\nOffline/Standby UPS:\n\nDescription: Provides basic protection; switches to battery during a power outage.\nMaintenance: Regular battery checks and replacement every 3-5 years.\nLine-Interactive UPS:\n\nDescription: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations.\nMaintenance: Inspect and test the battery and inverter regularly; check for dust accumulation.\nOnline Double-Conversion UPS:\n\nDescription: Provides continuous power and isolates equipment from power issues.\nMaintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates.\nModular UPS:\n\nDescription: Scalable systems that allow for adding or removing modules based on power needs.\nMaintenance: Regular checks on each module, ensuring proper connections and functionality.\nTypes of Batteries Used in UPS\nLead-Acid Batteries:\n\nTypes: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel.\nMaintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity.\nLithium-Ion Batteries:\n\nDescription: Increasingly used due to longer life and lighter weight.\nMaintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates.\nNickel-Cadmium (NiCd) Batteries:\n\nDescription: Used in specific applications; known for durability.\nMaintenance: Regularly test for capacity and perform equalization charging.\nRepair and Maintenance Practices\n1. Routine Inspections\nVisual Checks: Inspect for physical damage, corrosion, or loose connections.\nEnvironmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity).\n2. Battery Maintenance\nTesting: Conduct regular load tests and capacity tests to assess battery health.\nCleaning: Clean terminals and connections to prevent corrosion.\nReplacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid).\n3. UPS Maintenance\nFirmware Updates: Keep the UPS firmware updated for optimal performance.\nComponent Checks: Inspect capacitors, fans, and other internal components for wear and tear.\nCooling System: Ensure that cooling fans are operational and that vents are not blocked.\n4. Emergency Procedures\nTesting: Regularly test the UPS under load conditions to ensure it functions correctly during an outage.\nDocumentation: Maintain records of all maintenance activities, repairs, and battery replacements.\n5. Professional Servicing\nScheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS.\nEmergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts.\nConclusion\nRegular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries.\n\nFor specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "35 years", "capacity tests", "functionality types", "tailored solutions", "significantly extend", "timely repairs", "rapid response", "comprehensive inspections", "functions correctly", "load conditions", "cooling fans", "internal components", "longer life", "continuous power", "comprehensive overview", "ups failures", "complex systems", "ups systems", "specific applications", "performance check", "isolates equipment", "ups batteries repair", "ups systems batteries", "maintenance practices types", "maintenance activities repairs", "power issues maintenance", "battery backup ideal", "ups firmware updated", "detailed maintenance plans", "specific service providers", "structured maintenance schedule", "protecting sensitive equipment", "maintenance regular checks", "inverter regularly check", "engaging professional services", "manufacturer recommendations typically", "physical damage corrosion", "removing modules based", "basic protection switches" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 202, "imageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/0df11052da9246ec8521d0ce0744e86f.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-07T07:13:54.328Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/all-types-of-ups-batteries-repair-and-maintenance-of-ups/202", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "All Types Of Ups & Batteries Repair And Maintenance Of Ups", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6720980b2b5881cbadcda4e8", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Repairing And Maintaining UPS In Delhi", "description": "Repairing And Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring the reliability and longevity of the power backup system. Here’s a detailed overview of UPS battery maintenance and repair practices.\n\nUPS Battery Types\nLead-Acid Batteries:\n\nValve-Regulated Lead Acid (VRLA): Maintenance-free and sealed, suitable for most UPS systems.\nFlooded Lead Acid: Requires periodic maintenance and water topping.\nLithium-Ion Batteries:\n\nIncreasingly used due to longer life and higher efficiency but may require specific handling protocols.\nMaintenance Practices\nRegular Inspections:\n\nVisual Check: Inspect batteries for physical damage, corrosion, or leaks. Look for swelling or bulging in case of lead-acid batteries.\nConnections: Ensure all terminals and connections are tight and free of corrosion.\nCleaning:\n\nClean battery terminals with a mixture of baking soda and water to remove corrosion. Rinse with clean water and dry thoroughly.\nBattery Testing:\n\nVoltage Checks: Regularly measure the voltage of each battery to identify weak cells.\nLoad Testing: Perform load tests to ensure the battery can deliver the expected capacity under load conditions.\nTemperature Monitoring:\n\nMonitor battery temperature, especially in environments with high heat, as excessive temperatures can affect battery performance and lifespan.\nElectrolyte Level (for Flooded Batteries):\n\nCheck and maintain the electrolyte levels in flooded lead-acid batteries. Top up with distilled water as necessary.\nBattery Health Monitoring:\n\nUse battery management systems (BMS) for advanced monitoring of battery health, state of charge, and state of health.\nRepair Practices\nIdentifying Faults:\n\nCommon issues include short-circuited cells, sulfation, and capacity loss. Use diagnostic tools to identify problems.\nReplacing Individual Batteries:\n\nIf a battery within a pack fails, replace only the faulty battery if it’s compatible. However, it's often recommended to replace all batteries in a series to ensure uniform performance.\nEqualization Charging (for Flooded Batteries):\n\nPeriodically perform equalization charging to balance the charge across all cells and prevent sulfation.\nReconditioning:\n\nSome lead-acid batteries can be reconditioned through a process of controlled charging and discharging to restore capacity. This is not always successful and should be done by professionals.\nBattery Replacement:\n\nWhen batteries reach the end of their lifespan (typically 3-5 years for lead-acid), replace them with new ones. Ensure that replacements meet the manufacturer's specifications.\nBest Practices for Maintenance\nDocumentation:\n\nKeep records of inspections, tests, and replacements to track battery performance over time.\nEnvironmental Conditions:\n\nMaintain an optimal environment for batteries—ideally, a cool, dry place free from excessive humidity and temperature fluctuations.\nProfessional Servicing:\n\nConsider engaging professionals for complex repairs or maintenance tasks, especially for large or critical UPS systems.\nTraining:\n\nTrain personnel on proper handling, maintenance, and safety procedures related to UPS batteries.\nConclusion\nRegular maintenance and timely repairs of UPS batteries are essential for ensuring the reliability of power backup systems. By implementing best practices, monitoring battery health, and addressing issues promptly, you can prolong the life of your UPS batteries and enhance overall system performance. If you have specific questions or need further details on any aspect, feel free to ask!", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "3-5 years", "high heat", "load tests", "weak cells", "longer life", "baking soda", "clean water", "Load Testing", "Visual Check", "Common issues", "capacity loss", "water topping", "UPS batteries", "Voltage Checks", "timely repairs", "Best Practices", "faulty battery", "Delhi Repairing", "distilled water", "complex repairs", "load conditions", "physical damage", "Battery Testing", "Maintaining UPS", "cool, dry place", "diagnostic tools", "repair practices", "most UPS systems", "expected capacity", "safety procedures", "maintenance tasks", "Electrolyte Level", "higher efficiency", "detailed overview", "Flooded Batteries", "UPS Battery Types", "Flooded Lead Acid", "excessive humidity", "specific questions", "Lead-Acid Batteries", "Regular Inspections", "Regular maintenance", "optimal environment", "Battery Replacement", "battery temperature", "uniform performance", "advanced monitoring", "battery performance", "power backup system", "Individual Batteries", "periodic maintenance", "critical UPS systems", "Equalization Charging", "short-circuited cells", "Lithium-Ion Batteries", "Maintenance Practices", "Professional Servicing", "excessive temperatures", "Temperature Monitoring", "UPS battery maintenance", "Clean battery terminals", "temperature fluctuations", "Environmental Conditions", "Maintenance Documentation", "Battery Health Monitoring", "Valve-Regulated Lead Acid", "battery management systems", "overall system performance", "specific handling protocols", "Uninterruptible Power Supply" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 131, "imageuri": "https://bizimages.withfloats.com/actual/1c0f13c6e9d34936ad199dbe084446a5.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/1c0f13c6e9d34936ad199dbe084446a5.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-29T08:08:43.949Z", "updatedon": "2024-10-29T08:08:43.949Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/repairing-and-maintaining-ups-in-delhi/131", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Repairing And Maintaining UPS", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "671b5d321b61480021549fc2", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Online Ups Amc Repair & Services In Manesar", "description": "As a leading provider of UPS services, we understand the criticality of uninterrupted power supply for your business. Our team of highly skilled technicians is dedicated to delivering efficient and reliable online UPS services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad .\n\nWith our expertise and experience, we offer comprehensive solutions for online UPS installation, maintenance, and repair. Whether you are looking for a new installation or need assistance with troubleshooting and repairs, we have got you covered.\n\nUPS Repair & Services In Manesar\n\nWe specialize in UPS Repair & Services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . offering professional troubleshooting and repair. Our team is equipped to handle issues of any scale, ensuring your UPS systems are always in top working condition.\n\nMaintenance Contract\n\nAfter entering into AMC, the contract will do the 1st preventive maintenance to check UPS condition, Healthy and working UPS only will be considered under AMC and also Faulty will be repaired on chargeable basis before considering it under AMC.\nIf the batteries are found faulty at the time of inspection it will have to be replaced before taking it under AMC.\nAny make, any capacity (expect Vertiv & Emerson) Unlimited Break Down calls (Except Wire wound components, batteries, transformers).\nIncludes 100% labor and travel coverage 6 days/week, 8 hours/day.\nPerformed by ACCESS factory trained Customer Engineers.\nBreak down calls – UNLIMITED.\nSubject to all Terms & Conditions as noted in the ACCESS Maintenance Agreement.\n8 Hours Turnaround Time.\n\nPreventive Service\n\nPreventive Measurement : 4 PM per year Cleaning up of Unit, Visual Inspection tocheck any deformation.\nChecking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current.\nChecking and Adjustment (If needed) of Control parameters on different PCBs.\nTightness of all connections, if shut down possible.\nFunctional Checking up of Rectifier section.\nFunctional Checking up of Inverter section.\nFunctional Checking up of Static Switch Section.\nWith customer approval, perform operational tests of the system including unit transfer and battery discharge.\nMaintaining the posted checklist at the client place.\nBattery Health checks with Multi Meter.\n\nBattery AMC\n\nIntroducing for the very first time in the Industry “Battery AMC”, wherein you get your additional 3rd year warranty only @15% of your previous pay for the batteries.\n\nQuanta Amaron Make of battery is only included in AMC.\nBattery should be within the warranty period.\nCurrently AMC will be carried forward only for Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . Region.\n\nUPS Renting\n\nCost Effective: Rental UPS is very cost effective, you can save on huge project costs.\nPower Stability: Provides stable power continuously and saves all your expensive equipment from Power Surges.\nNo Minimum Requirements: Online UPS available from 1KVA to 600 KVA on rent for short & long term.\nNo Maintenance Cost: UPS Rental helps you save on maintenance & Servicing cost.\nCustomisable: Special customization facility available for your specific needs.\nNo Power Cuts: Battery life is always ON, due to immediate replacement facility.\n\nMaintenance Contracts\n\nOn line ups in each kVA rating and battery backup system are very sensitive issues and so it should be taken care utmost to enhance the life of UPS system and battery life for almost 99% up time during performance. Access Power Link is a leader in this market for 25 years having expertise and experience in the field to ensure hassle-free UPS AMC services on PAN INDIA level.\n\n\nUPS Servicing To Suit You\n\nOur response time is the time to get to site, not the time for a callback Travel and labour is included in all contract prices unless not required\nOur technical support is offered by actual UPS experts, not a call centre.\nOur inclusive parts contracts include ALL parts not just “consumables”.\nOur preventative maintenance includes multipoint checks not just visuals.\nWe offer different plans to pass on savings during normal working hours.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "4 PM", "600 KVA", "25 years", "long term", "ALL parts", "100% labor", "Amc Repair", "kVA rating", "first time", "UPS Repair", "DC voltage", "UPS Rental", "Rental UPS", "Battery AMC", "call centre", "Multi Meter", "Cleaning up", "UPS Renting", "UPS systems", "Battery life", "previous pay", "client place", "Power Surges", "stable power", "unit transfer", "response time", "UPS Servicing", "UPS condition", "No Power Cuts", "specific needs", "Servicing cost", "different PCBs", "ACCESS factory", "contract prices", "different plans", "callback Travel", "travel coverage", "Power Stability", "warranty period", "PAN INDIA level", "sensitive issues", "Maintenance Cost", "chargeable basis", "leading provider", "Inverter section", "Power parameters", "new installation", "Visual Inspection", "technical support", "battery discharge", "operational tests", "customer approval", "Rectifier section", "multipoint checks", "Access Power Link", "Control parameters", "Customer Engineers", "Preventive Service", "Quanta Amaron Make", "actual UPS experts", "huge project costs", "Functional Checking", "expensive equipment", "skilled technicians", "Minimum Requirements", "normal working hours", "Maintenance Contracts", "battery backup system", "Battery Health checks", "Static Switch Section", "top working condition", "Wire wound components", "Preventive Measurement", "comprehensive solutions", "online UPS installation", "8 Hours Turnaround Time", "preventative maintenance", "inclusive parts contracts", "1st preventive maintenance", "uninterrupted power supply", "Unlimited Break Down calls", "professional troubleshooting", "ACCESS Maintenance Agreement", "hassle-free UPS AMC services", "reliable online UPS services", "additional 3rd year warranty", "immediate replacement facility", "Special customization facility" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 116, "imageuri": "https://bizimages.withfloats.com/actual/84f8b6b04e1b48d49747ad9567450757.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/84f8b6b04e1b48d49747ad9567450757.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-25T08:56:18.006Z", "updatedon": "2024-10-25T08:56:18.006Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/online-ups-amc-repair-services-in-manesar/116", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Online Ups Amc Repair & Services", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "671a06eada1877a6e73a07a0", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Rental And Maintenance Ups And Batteries In Central Delhi", "description": "Here are the key details about UPS and batteries rental and maintenance:\n\nWhat is UPS and Batteries Rental?\n\nUPS and batteries rental is a service that provides temporary or long-term rental of UPS systems and batteries to meet your power backup needs. This service is ideal for organizations that require a reliable power backup solution for a short period or for those who do not want to invest in purchasing a UPS system.\n\nBenefits of UPS and Batteries Rental\n\nCost-Effective: Rental options are often more cost-effective than purchasing a UPS system, especially for short-term needs.\nFlexibility: Rental options provide flexibility to upgrade or downgrade your power backup solution as needed.\nQuick Deployment: Rental UPS systems and batteries can be quickly deployed to meet your power backup needs.\nTypes of UPS and Batteries Rental\n\nShort-Term Rental: Rental options for a short period, typically for events or temporary power backup needs.\nLong-Term Rental: Rental options for an extended period, typically for organizations that require a reliable power backup solution for an extended period.\nCustomized Rental: A tailored rental solution that meets the specific needs of your organization.\nWhat is UPS and Batteries Maintenance?\n\nUPS and batteries maintenance is a service that ensures the smooth functioning of your UPS system and batteries. This service includes regular maintenance, repairs, and replacement of parts to prevent downtime and data loss.\n\nBenefits of UPS and Batteries Maintenance\n\nReduced Downtime: Regular maintenance ensures that your UPS system and batteries are functioning properly, reducing the risk of downtime and data loss.\nExtended Equipment Life: Maintenance helps to extend the life of your UPS system and batteries by identifying and replacing worn-out parts.\nPriority Support: With a maintenance contract, you get priority support and response times, ensuring that your issues are resolved quickly.\nServices Covered Under UPS and Batteries Maintenance\n\nRegular Maintenance: Scheduled maintenance visits to ensure the UPS system and batteries are functioning properly.\nRepair and Replacement: Repair or replacement of faulty parts to ensure the UPS system and batteries are functioning at optimal levels.\nBattery Testing and Replacement: Testing and replacement of batteries to ensure they are functioning within specified parameters.\nUPS System Testing: Testing of the UPS system to ensure it is functioning properly and providing clean power to your equipment.\nTypes of UPS and Batteries Maintenance\n\nComprehensive Maintenance: Covers all maintenance, repairs, and replacement of parts.\nNon-Comprehensive Maintenance: Covers only maintenance and repairs, with replacement of parts at an additional cost.\nCustomized Maintenance: A tailored maintenance solution that meets the specific needs of your organization.\nWhy is UPS and Batteries Rental and Maintenance Important?\n\nBusiness Continuity: UPS and batteries rental and maintenance ensure that your business remains operational even during power outages, reducing the risk of data loss and downtime.\nData Protection: Rental and maintenance services help to protect your critical data by ensuring that your UPS system and batteries are functioning properly.\nEquipment Protection: Rental and maintenance services help to protect your equipment from power surges and spikes, reducing the risk of damage and downtime.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 107, "imageuri": "https://bizimages.withfloats.com/actual/16477f9ab5634ab4a5c4aa5f68365953.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/16477f9ab5634ab4a5c4aa5f68365953.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-24T08:35:54.235Z", "updatedon": "2024-10-24T08:35:54.235Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/rental-and-maintenance-ups-and-batteries-in-central-delhi/107", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Rental And Maintenance", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "671a03fc173707771118858a", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amc For Ups And Batteries In Yamuna Expressway Noida", "description": "UPS (Uninterruptible Power Supply) and batteries AMC (Annual Maintenance Contract) is a service agreement that ensures the smooth functioning of your UPS system and batteries. Here are the key details:\n\nWhat is UPS and Batteries AMC?\n\nUPS and Batteries AMC is a comprehensive maintenance program designed to ensure the reliability and performance of your UPS system and batteries. The AMC provides regular maintenance, repairs, and replacement of parts to prevent downtime and data loss.\n\nBenefits of UPS and Batteries AMC\n\nReduced Downtime: Regular maintenance ensures that your UPS system and batteries are functioning properly, reducing the risk of downtime and data loss.\nExtended Equipment Life: The AMC helps to extend the life of your UPS system and batteries by identifying and replacing worn-out parts.\nPriority Support: With an AMC, you get priority support and response times, ensuring that your issues are resolved quickly.\nCost Savings: The AMC helps to reduce costs by identifying and fixing potential issues before they become major problems.\nServices Covered Under UPS and Batteries AMC\n\nRegular Maintenance: Scheduled maintenance visits to ensure the UPS system and batteries are functioning properly.\nRepair and Replacement: Repair or replacement of faulty parts to ensure the UPS system and batteries are functioning at optimal levels.\nBattery Testing and Replacement: Testing and replacement of batteries to ensure they are functioning within specified parameters.\nUPS System Testing: Testing of the UPS system to ensure it is functioning properly and providing clean power to your equipment.\nTypes of UPS and Batteries AMC\n\nComprehensive AMC: Covers all maintenance, repairs, and replacement of parts.\nNon-Comprehensive AMC: Covers only maintenance and repairs, with replacement of parts at an additional cost.\nCustomized AMC: A tailored AMC that meets the specific needs of your organization.\nWhy is UPS and Batteries AMC Important?\n\nBusiness Continuity: UPS and Batteries AMC ensures that your business remains operational even during power outages, reducing the risk of data loss and downtime.\nData Protection: The AMC helps to protect your critical data by ensuring that your UPS system and batteries are functioning properly.\nEquipment Protection: The AMC helps to protect your equipment from power surges and spikes, reducing the risk of damage and downtime.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 106, "imageuri": "https://bizimages.withfloats.com/actual/c5ea99769c494308b7a8cedc0630ee01.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/c5ea99769c494308b7a8cedc0630ee01.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-24T08:23:24.727Z", "updatedon": "2024-10-24T08:23:24.727Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amc-for-ups-and-batteries-in-yamuna-expressway-noida/106", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Ups Battery ", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6717480bed6bc27bad47e161", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Vertiv 10kVA UPS Repair In Bilaspur Kalan Manesar", "description": "\n\nWhen it comes to Vertiv 10kVA UPS repair and testing, it involves several key processes to ensure that the UPS functions correctly and reliably. Below are the details regarding Vertiv 10kVA UPS repair and testing:\n\nVertiv 10kVA UPS Repair\nCommon Issues:\n\nBattery Failure: Batteries may degrade over time and need replacement.\nInverter Problems: The inverter may fail to convert DC to AC power.\nOverheating: Excessive heat can damage internal components.\nFaulty Charging Circuit: Issues with the charging system can prevent batteries from charging properly.\nSoftware Failures: Problems with firmware can affect UPS functionality.\nRepair Process:\n\nDiagnosis:\n\nUse diagnostic tools to identify issues.\nCheck for error codes or alerts on the UPS display.\nComponent Testing:\n\nTest batteries for capacity and voltage.\nInspect the inverter and charging circuits for faults.\nReplacement of Parts:\n\nReplace faulty batteries with new ones.\nRepair or replace damaged circuit boards, inverters, or other components.\nCalibration:\n\nCalibrate the UPS settings to ensure optimal performance.\nFinal Testing:\n\nConduct a load test to verify that the UPS can handle its rated capacity.\nVertiv 10kVA UPS Testing\nTesting Procedures:\n\nVisual Inspection:\n\nCheck for physical damage, loose connections, or corrosion.\nBattery Testing:\n\nMeasure the voltage and capacity of the batteries.\nConduct a discharge test to ensure batteries can hold a charge.\nLoad Testing:\n\nConnect a load to the UPS and monitor its performance.\nEnsure that the UPS can supply power for the specified duration under load.\nTransfer Time Testing:\n\nMeasure the time it takes for the UPS to switch from mains to battery power and back.\nEfficiency Testing:\n\nAssess the efficiency of the UPS under various loads to ensure it meets manufacturer specifications.\nMaintenance Recommendations\nRegular Maintenance: Schedule regular checks (at least annually) to ensure all components are functioning correctly.\nBattery Replacement: Replace batteries every 3-5 years, depending on usage and manufacturer recommendations.\nFirmware Updates: Keep the UPS firmware updated to benefit from the latest features and fixes.\nConclusion\nProper repair and testing of Vertiv 10kVA UPS systems are crucial for ensuring reliable power backup. Regular maintenance can prevent unexpected failures and extend the lifespan of the unit. If you require further details on specific models or repair services, feel free to ask!", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 91, "imageuri": "https://bizimages.withfloats.com/actual/a121bc19edb142a6bd12b9e5e5b202cf.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/a121bc19edb142a6bd12b9e5e5b202cf.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-22T06:36:59.265Z", "updatedon": "2024-10-22T06:36:59.265Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-10kva-ups-repair-in-bilaspur-kalan-manesar/91", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "UPS Repair", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
replacement repair considerations?

Still searching for
replacement repair considerations?

Chat with us