Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

UNIVERSALPOWERSYSTEMF82C 6543468cae4e1df6fbef3986 Products https://locations.universalpower.co.in/bhiwadi
{ "products": [ { "_id": "67d52d8a4507f670f3d4fa58", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Emerson 3-Phase Ups In Manesar", "description": "Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues.\n\nKey Features of Emerson 3-Phase UPS:\nPower Capacity:\n\n3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model.\nSuitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings.\nTechnology:\n\nDouble Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging.\nEfficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs.\nBattery Management: Integrated advanced battery management for monitoring health, charge, and backup times.\nHigh Availability:\n\nDesigned to provide reliable power for mission-critical applications.\nHot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply.\nScalability: Many models allow for modular expansion, meaning you can add additional capacity as needed.\nInput/Output Voltage:\n\nInput Voltage: Common input voltages are 380V, 400V, and 415V (3-phase).\nOutput Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards.\nPower Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency.\nAdvanced Features:\n\nLCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring.\nRemote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics.\nBypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime.\nDesign and Durability:\n\nCompact Design: Many models are designed to be space-efficient without compromising on power or cooling needs.\nRack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs.\nThermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating.\nApplications:\n\nData Centers: Ensures uptime for servers and networking equipment.\nIndustrial Equipment: Protects critical machinery and automated systems from power failures.\nTelecommunications: Keeps communication systems running without interruption.\nHospitals: Supports life-saving equipment and systems that require constant power.\nCommercial Buildings: Ensures backup power for office systems and equipment.\nMaintenance and Service:\n\nSmart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required.\nServiceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition.\nProactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations.\nPopular Models:\nEmerson (now part of Vertiv) offers various UPS models under different series, such as:\n\nVertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications.\nVertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability.\nVertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications.\nAdvantages of Emerson 3-Phase UPS:\nHigh Reliability: Ensures critical equipment remains powered during power failures or fluctuations.\nAdvanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility.\nEnergy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact.\nScalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand.\n\nConclusion:\nEmerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "800 kva", "10 kva", "models batteries", "equipment maintenance", "small office", "380v 400v", "largescale facilities", "ups models", "excellent solutions", "easily expand", "data centers", "remote monitoring", "service contracts", "comprehensive support", "alert users", "realtime alerts", "remote access", "realtime data", "model suitable", "wide range", "ups remains", "office systems", "automated systems", "offers scalability", "vertiv offers", "bypass mode", "industrial commercial", "robust design", "higher depending", "critical infrastructure", "power failures", "monitoring health charge", "modular ups system", "advanced cooling systems", "emerson ups systems", "ups systems typically", "ensure uninterrupted operation", "3phase systems depending", "critical infrastructure applications", "power failures telecommunications", "emerson 3phase ups", "communication systems running", "environmental impact scalability", "industrial applications advantages", "vertiv liebert ita2", "diagnostics bypass capability", "high power factor", "provide reliable power", "power capacities generally", "provide uninterrupted power", "tower formats depending", "durability compact design", "avoid downtime design", "require high uptime", "flexibility energy efficiency", "diagnostic tools faults", "maintain efficient operation", "add additional capacity", "modular expansion meaning", "reduce energy consumption" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 229, "imageuri": "https://bizimages.withfloats.com/actual/187708a304fa44f1b41acc0e625a7a30.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/187708a304fa44f1b41acc0e625a7a30.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-15T07:34:34.549Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/emerson-3-phase-ups-in-manesar/229", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Emerson 3-Phase Ups In Manesar", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d13de22912ddb97fcecda8", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Maintenance Tips for UPS Systems and Batteries​", "description": "Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips:\n\n1. Regular Inspection\nVisual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion.\nConnections: Ensure that all connections are secure and free from dust and corrosion.\n2. Battery Maintenance\nBattery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load.\nClean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting.\nCheck Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed.\n3. Environmental Considerations\nTemperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly.\nVentilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow.\n4. Regular Testing\nSelf-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature.\nLoad Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage.\n5. Firmware and Software Updates\nKeep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security.\nMonitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues.\n6. Battery Replacement\nFollow Manufacturer Guidelines: Replace batteries according to the manufacturer\\'s recommendations, typically every 3-5 years for lead-acid batteries.\nDispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety.\n7. Load Management\nAvoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life.\nBalanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded.\n8. Documentation\nKeep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance.\n9. Professional Maintenance\nSchedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems.\n10. User Training\nEducate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "35 years", "maintenance tips", "ups system", "ups systems", "rated capacity", "distilled water", "power outage", "issues encountered", "records maintain", "overloaded 8 documentation", "single outlet", "receive alerts", "functioning correctly", "enclosed spaces", "baking soda", "check voltage", "improve performance", "ensure terminals", "load evenly", "required load", "battery tester", "software updates", "corrosion connections ensure", "ups monitoring software", "leadacid batteries dispose", "battery terminals clean", "load clean terminals", "track performance metrics", "ensuring reliable performance", "total load connected", "install firmware updates", "security monitoring software", "manufacturers recommendations typically", "electrolyte levels regularly", "physical damage leaks" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 221, "imageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-12T07:55:14.561Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/maintenance-tips-for-ups-systems-and-batteries-/221", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Maintenance Tips for UPS Systems and Batteries​", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "672b00f2df47611de70efcbe", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Vertiv 2kVA UPS IN MANESAR", "description": "Vertiv 2kVA UPS \n\nSB MODEL & LB MODEL\n\nThe Vertiv 2kVA UPS models in the SB (Standby) and LB (Line-Interactive) series offer similar features to their 1kVA counterparts, but with higher power ratings to cater to larger or more demanding devices. Here are the general details for each series in the 2kVA range:\n\n1. Vertiv 2kVA SB (Standby) Series UPS\nThe SB Series for 2kVA is a basic UPS solution designed for small office and home office environments where power backup and protection from power surges are required for a range of devices.\n\nKey Features:\nTopology: Standby (Off-line)\nPower Rating: 2kVA / 2000VA\nOutput Power: 1200W - 1600W (depending on model)\nInput Voltage: 160V - 280V (wide voltage range)\nOutput Voltage: 230V ± 10%\nWaveform Type: Simulated Sinewave (approximate sinewave output)\nBattery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid)\nBattery Capacity: Typically 12V, 9Ah or 12Ah (varies by model)\nCharging Time: Approximately 4-8 hours for a full charge\nBackup Time (Runtime): Provides backup for 5-15 minutes depending on the load (e.g., for 60-80% load)\nCooling: Fan-assisted cooling for heat dissipation\nInterfaces: USB or serial ports for monitoring (depending on model)\nForm Factor: Typically Tower\n\nAdditional Features:\nSurge protection\nOverload and short-circuit protection\nLow battery, overload, and fault indicators\nAutomatic shutdown feature with optional software\nAudible alarms for power events (e.g., overload, low battery, fault)\nCompact design for easier placement in home office or small business environments\n\nIdeal Use Case:\nHome offices and small businesses\nWorkstations, point-of-sale (POS) systems, and network equipment\nConsumer electronics that need surge protection and limited backup time\n\n2. Vertiv 2kVA LB (Line-Interactive) Series UPS\nThe LB Series for 2kVA is a more robust and efficient option than the Standby series, suitable for more demanding applications. It provides better voltage regulation and a higher level of protection due to the line-interactive topology.\n\nKey Features:\nTopology: Line-Interactive\nPower Rating: 2kVA / 2000VA\nOutput Power: 1400W - 1800W (varies by model)\nInput Voltage: 140V - 300V (wider input range than SB series)\nOutput Voltage: 230V ± 10%\nWaveform Type: Simulated Sinewave (typically) or Pure Sinewave (depending on model)\nBattery Type: Sealed Lead-Acid (SLA) or VRLA\nBattery Capacity: Typically 12V, 9Ah or 12Ah (varies by model)\nCharging Time: Around 4-6 hours to fully charge the battery\nBackup Time (Runtime): Can provide backup for 10-20 minutes depending on load (typically for a 50-70% load)\nForm Factor: Tower or Rackmount (depending on model)\nInterfaces: USB and/or Serial port for monitoring and management (some models support software for auto-shutdown)\n\nAdditional Features:\nAutomatic Voltage Regulation (AVR) to correct voltage fluctuations\nCold Start: Can be turned on without mains power (useful in power failure situations)\nOverload, short-circuit, and low battery protection\nLCD or LED display (on some models) for real-time monitoring of UPS status, battery level, load capacity, etc.\nEnhanced battery management and energy-saving features to extend battery lifespan\nAudio and visual alerts for power failures, overloads, and battery issues\nSmart monitoring and management with optional software for power event logging and automatic shutdown\n\nIdeal Use Case:\nSmall to medium-sized servers, workstations, and network equipment\nSensitive equipment needing more precise power regulation\nIT infrastructures that require more consistent and reliable power protection\nCritical devices where frequent voltage fluctuations or outages could damage equipment\n\nConclusion:\nSB Series (2kVA): The SB Series is a more cost-effective option for users who need basic backup power and surge protection for small office or home use. It is ideal for lower-power devices and non-critical applications where voltage regulation isn't a priority.\n\nLB Series (2kVA): The LB Series provides more robust features, such as Automatic Voltage Regulation (AVR), better battery management, and longer runtime. This makes it a better option for users who need more reliable and consistent power, especially in small to medium business environments, servers, or critical systems where power fluctuations are more common.\n", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 158, "imageuri": "https://bizimages.withfloats.com/actual/5d0ae2cd674f4d4db5501d7481d0e7de.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/5d0ae2cd674f4d4db5501d7481d0e7de.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-11-06T05:38:58.462Z", "updatedon": "2024-11-06T05:38:58.462Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-2kva-ups-in-manesar/158", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "2 KVA UPS", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "671f6329426803ca328c58b4", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "UPS Rental Services In Gujar Majri Bawal", "description": "\nUPS rental services provide temporary power backup solutions for various applications. Here’s an overview of what these services typically include:\n\n\nKey Features of UPS Rental Services\nFlexible Rental Terms: Options for short-term or long-term rentals, accommodating project-based or seasonal needs.\n\nRange of Capacities: Availability of different UPS systems, typically ranging from small (kVA) to large (up to several hundred kVA), catering to diverse requirements.\n\nVarious Topologies: Access to different UPS technologies (online, offline, line-interactive) based on the specific power protection needs.\n\nInstallation and Setup: Many services include professional installation, ensuring the system is configured correctly for optimal performance.\n\nMaintenance and Support: Regular maintenance, technical support, and emergency services may be included, ensuring reliability throughout the rental period.\n\nTransportation and Logistics: The rental company often handles delivery, setup, and pick-up of the UPS units.\n\nBattery Options: Availability of different battery configurations and types to suit the application, including maintenance-free options.\n\nCustom Solutions: Ability to provide tailored solutions based on specific site requirements and load assessments.\n\nCommon Applications\nEvents and Temporary Installations: Trade shows, conferences, and exhibitions requiring backup power.\nConstruction Sites: Providing power to equipment and tools on temporary job sites.\nData Centers: Emergency power during upgrades, maintenance, or outages.\nTesting and Development: Ensuring power stability during product testing or development phases.\nNatural Disasters: Providing emergency power in the aftermath of outages.\nAdvantages of UPS Rental Services\nCost-Effective: No capital expenditure is required, making it financially advantageous for short-term needs.\nNo Long-Term Commitment: Flexibility to scale power needs up or down based on project requirements.\nAccess to Latest Technology: Ability to utilize the latest UPS systems without the need for long-term investment.\nReduced Maintenance Responsibility: The rental company typically manages maintenance, reducing operational burdens.\nConsiderations\nLoad Assessment: It's crucial to assess power needs accurately to select the appropriate UPS size and capacity.\nService Agreements: Review terms and conditions, including support and maintenance provisions.\nDelivery and Setup Time: Ensure timely delivery and installation to meet project timelines.\nLocal Regulations: Check compliance with local electrical and safety regulations.\nHow to Choose a UPS Rental Service\nReputation: Look for established companies with positive reviews and a track record in UPS rentals.\nRange of Equipment: Ensure the provider has a diverse inventory to meet various power needs.\nCustomer Support: Consider the level of support offered, including technical assistance and emergency services.\nPricing: Compare quotes from different providers to ensure competitive pricing.\nIf you have specific requirements or questions about UPS rental services, feel free to ask!", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 126, "imageuri": "https://bizimages.withfloats.com/actual/c4495bddcc134d6d95964b2262f02450.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/c4495bddcc134d6d95964b2262f02450.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-28T10:10:49.921Z", "updatedon": "2024-10-28T10:10:49.921Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/ups-rental-services-in-gujar-majri-bawal/126", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Ups Rental", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "671b5d321b61480021549fc2", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Online Ups Amc Repair & Services In Manesar", "description": "As a leading provider of UPS services, we understand the criticality of uninterrupted power supply for your business. Our team of highly skilled technicians is dedicated to delivering efficient and reliable online UPS services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad .\n\nWith our expertise and experience, we offer comprehensive solutions for online UPS installation, maintenance, and repair. Whether you are looking for a new installation or need assistance with troubleshooting and repairs, we have got you covered.\n\nUPS Repair & Services In Manesar\n\nWe specialize in UPS Repair & Services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . offering professional troubleshooting and repair. Our team is equipped to handle issues of any scale, ensuring your UPS systems are always in top working condition.\n\nMaintenance Contract\n\nAfter entering into AMC, the contract will do the 1st preventive maintenance to check UPS condition, Healthy and working UPS only will be considered under AMC and also Faulty will be repaired on chargeable basis before considering it under AMC.\nIf the batteries are found faulty at the time of inspection it will have to be replaced before taking it under AMC.\nAny make, any capacity (expect Vertiv & Emerson) Unlimited Break Down calls (Except Wire wound components, batteries, transformers).\nIncludes 100% labor and travel coverage 6 days/week, 8 hours/day.\nPerformed by ACCESS factory trained Customer Engineers.\nBreak down calls – UNLIMITED.\nSubject to all Terms & Conditions as noted in the ACCESS Maintenance Agreement.\n8 Hours Turnaround Time.\n\nPreventive Service\n\nPreventive Measurement : 4 PM per year Cleaning up of Unit, Visual Inspection tocheck any deformation.\nChecking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current.\nChecking and Adjustment (If needed) of Control parameters on different PCBs.\nTightness of all connections, if shut down possible.\nFunctional Checking up of Rectifier section.\nFunctional Checking up of Inverter section.\nFunctional Checking up of Static Switch Section.\nWith customer approval, perform operational tests of the system including unit transfer and battery discharge.\nMaintaining the posted checklist at the client place.\nBattery Health checks with Multi Meter.\n\nBattery AMC\n\nIntroducing for the very first time in the Industry “Battery AMC”, wherein you get your additional 3rd year warranty only @15% of your previous pay for the batteries.\n\nQuanta Amaron Make of battery is only included in AMC.\nBattery should be within the warranty period.\nCurrently AMC will be carried forward only for Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . Region.\n\nUPS Renting\n\nCost Effective: Rental UPS is very cost effective, you can save on huge project costs.\nPower Stability: Provides stable power continuously and saves all your expensive equipment from Power Surges.\nNo Minimum Requirements: Online UPS available from 1KVA to 600 KVA on rent for short & long term.\nNo Maintenance Cost: UPS Rental helps you save on maintenance & Servicing cost.\nCustomisable: Special customization facility available for your specific needs.\nNo Power Cuts: Battery life is always ON, due to immediate replacement facility.\n\nMaintenance Contracts\n\nOn line ups in each kVA rating and battery backup system are very sensitive issues and so it should be taken care utmost to enhance the life of UPS system and battery life for almost 99% up time during performance. Access Power Link is a leader in this market for 25 years having expertise and experience in the field to ensure hassle-free UPS AMC services on PAN INDIA level.\n\n\nUPS Servicing To Suit You\n\nOur response time is the time to get to site, not the time for a callback Travel and labour is included in all contract prices unless not required\nOur technical support is offered by actual UPS experts, not a call centre.\nOur inclusive parts contracts include ALL parts not just “consumables”.\nOur preventative maintenance includes multipoint checks not just visuals.\nWe offer different plans to pass on savings during normal working hours.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "4 PM", "600 KVA", "25 years", "long term", "ALL parts", "100% labor", "Amc Repair", "kVA rating", "first time", "UPS Repair", "DC voltage", "UPS Rental", "Rental UPS", "Battery AMC", "call centre", "Multi Meter", "Cleaning up", "UPS Renting", "UPS systems", "Battery life", "previous pay", "client place", "Power Surges", "stable power", "unit transfer", "response time", "UPS Servicing", "UPS condition", "No Power Cuts", "specific needs", "Servicing cost", "different PCBs", "ACCESS factory", "contract prices", "different plans", "callback Travel", "travel coverage", "Power Stability", "warranty period", "PAN INDIA level", "sensitive issues", "Maintenance Cost", "chargeable basis", "leading provider", "Inverter section", "Power parameters", "new installation", "Visual Inspection", "technical support", "battery discharge", "operational tests", "customer approval", "Rectifier section", "multipoint checks", "Access Power Link", "Control parameters", "Customer Engineers", "Preventive Service", "Quanta Amaron Make", "actual UPS experts", "huge project costs", "Functional Checking", "expensive equipment", "skilled technicians", "Minimum Requirements", "normal working hours", "Maintenance Contracts", "battery backup system", "Battery Health checks", "Static Switch Section", "top working condition", "Wire wound components", "Preventive Measurement", "comprehensive solutions", "online UPS installation", "8 Hours Turnaround Time", "preventative maintenance", "inclusive parts contracts", "1st preventive maintenance", "uninterrupted power supply", "Unlimited Break Down calls", "professional troubleshooting", "ACCESS Maintenance Agreement", "hassle-free UPS AMC services", "reliable online UPS services", "additional 3rd year warranty", "immediate replacement facility", "Special customization facility" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 116, "imageuri": "https://bizimages.withfloats.com/actual/84f8b6b04e1b48d49747ad9567450757.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/84f8b6b04e1b48d49747ad9567450757.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-25T08:56:18.006Z", "updatedon": "2024-10-25T08:56:18.006Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/online-ups-amc-repair-services-in-manesar/116", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Online Ups Amc Repair & Services", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "671894f87b19ca400cddba58", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Vertiv Ups Repairing In Ardee City Gurgaon", "description": "Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations:\n\n\nUPS Repair Process\nInitial Assessment\n\nIdentify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms.\nVisual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections.\nDiagnosis\n\nSelf-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues.\nMultimeter Testing: Measure voltage, current, and resistance to identify electrical issues.\nBattery Testing: Check the health of the batteries using a battery tester or multimeter.\nCheck Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning.\nCommon Issues\n\nBattery Failure: Batteries may need replacement due to age or over-discharge.\nCapacitor Issues: Capacitors can fail due to heat or age, leading to performance issues.\nCooling Problems: Blocked fans or insufficient ventilation can cause overheating.\nControl Board Malfunctions: Issues with the control board can affect the UPS's operation.\nInput/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry.\nRepair and Replacement\n\nBattery Replacement: Remove and replace old batteries with new ones of the same specifications.\nComponent Replacement: Replace faulty capacitors, fuses, or other components as diagnosed.\nResoldering Connections: Fix any broken or loose solder joints on the circuit board.\nSoftware/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance.\nTesting After Repair\n\nFunctional Testing: After repairs, perform a complete functional test of the UPS.\nLoad Testing: Test the UPS under load to ensure it can handle the required capacity.\nBattery Cycle Testing: Run the UPS on battery power to check for proper operation.\nFinal Inspection\n\nSafety Check: Ensure all repairs meet safety standards.\nDocumentation: Document the repairs, parts replaced, and any other relevant information for future reference.\nMaintenance Tips\nRegular Testing: Conduct regular self-tests and inspections to catch issues early.\nBattery Maintenance: Check battery connections and terminals periodically; keep them clean and tight.\nEnvironment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan.\nFirmware Updates: Keep the UPS firmware updated for improved performance and security.\nProfessional Repair Services\nWhen to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional.\nAuthorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs.\nConclusion\nRepairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 97, "imageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/3901da54f81648feacc10699c194cbeb.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-23T06:17:28.889Z", "updatedon": "2024-10-23T06:17:28.889Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-ups-repairing-in-ardee-city-gurgaon/97", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "UPS Repair", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67120454d449d74b99f70970", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Apc Ups Repairing And Maintenance In \tAurangabad Sonipat", "description": "Repairing and testing an APC UPS (Uninterruptible Power Supply) involves several steps to diagnose issues and ensure the unit functions properly. Here’s a detailed guide on how to approach this:\n\nCommon Issues with APC UPS\nBattery Failure: Most common issue; symptoms include frequent beeping and inability to hold a charge.\nOverload: The UPS may beep continuously if connected devices exceed its capacity.\nFaulty Output: No power output despite being plugged in.\nFirmware Issues: May require updates or resets.\nTools Needed\nMultimeter\nScrewdriver set\nReplacement batteries (if needed)\nLaptop or PC for firmware updates\nDiagnostic software (if applicable)\nTesting Procedure\nVisual Inspection:\n\nCheck for physical damage, burnt components, or loose connections.\nInspect the battery for any signs of swelling or leakage.\nBattery Testing:\n\nDisconnect the UPS from the wall outlet.\nUse a multimeter to measure the battery voltage. Compare it to the rated voltage (e.g., 12V for most lead-acid batteries).\nIf the voltage is significantly lower, consider replacing the battery.\nLoad Testing:\n\nConnect a load tester to the UPS and apply a known load (within the UPS capacity).\nMonitor the output voltage and see if it remains stable under load.\nOutput Testing:\n\nPlug the UPS into the wall and turn it on.\nMeasure the output voltage with a multimeter to ensure it’s delivering the correct voltage (typically around 120V or 230V depending on your region).\nCheck if the UPS switches to battery mode when you disconnect it from the wall.\nOverload Testing:\n\nGradually increase the load on the UPS until it beeps or shuts down.\nVerify that it returns to normal operation once the overload is removed.\nRepair Procedures\nBattery Replacement:\n\nFollow the manufacturer’s guidelines for replacing batteries.\nDispose of old batteries responsibly.\nFirmware Updates:\n\nConnect the UPS to a computer.\nUse APC’s software (like PowerChute) to check for and install firmware updates.\nComponent Repair:\n\nIf internal components (like capacitors or fans) are damaged, soldering skills may be required for repairs or replacements.\nReassembly:\n\nCarefully reassemble the UPS, ensuring all screws are tightened and no wires are pinched.\nFinal Testing\nAfter repairs, conduct a full load test to ensure the UPS operates correctly under stress.\nMonitor for any unusual noises or overheating during operation.\nSafety Precautions\nAlways ensure the UPS is unplugged before performing internal inspections or repairs.\nHandle batteries with care, as they can be hazardous.\nConclusion\nRegular testing and maintenance of your APC UPS can extend its lifespan and ensure reliable performance. If issues persist after self-repair attempts, consider consulting a professional technician or contacting APC support for assistance.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "The UPS", "wall outlet", "load tester", "APC support", "UPS capacity", "Load Testing", "battery mode", "common issue", "power output", "old batteries", "rated voltage", "Final Testing", "Faulty Output", "several steps", "output voltage", "unusual noises", "Output Testing", "detailed guide", "full load test", "Firmware Issues", "battery voltage", "Battery Testing", "Battery Failure", "correct voltage", "Regular testing", "physical damage", "Screwdriver set", "normal operation", "firmware updates", "soldering skills", "Component Repair", "burnt components", "frequent beeping", "Repair Procedures", "loose connections", "Visual Inspection", "Testing Procedure", "connected devices", "Apc Ups Repairing", "Safety Precautions", "Aurangabad Sonipat", "Diagnostic software", "lead-acid batteries", "Battery Replacement", "internal components", "self-repair attempts", "reliable performance", "internal inspections", "Replacement batteries", "professional technician", "Uninterruptible Power Supply" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 73, "imageuri": "https://bizimages.withfloats.com/actual/fe5e65ee545a4e2b8d06898bed2aa8fe.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/fe5e65ee545a4e2b8d06898bed2aa8fe.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-18T06:46:44.811Z", "updatedon": "2024-10-18T06:46:44.811Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/apc-ups-repairing-and-maintenance-in-aurangabad-sonipat/73", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "Apc Ups Repairing And Maintenance In \tAurangabad Sonipat", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6711f54bc041059cec31479e", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Batteries Apc Ups In Sector 53 Noida", "description": "Using Amaron batteries with APC (American Power Conversion) UPS (Uninterruptible Power Supply) systems can provide reliable backup power. Here’s a comprehensive overview of how to pair them effectively:\n\nAPC UPS Overview\nPurpose: Provides emergency power during outages and stabilizes voltage fluctuations.\nTypes: Ranges from consumer models to enterprise-level systems.\n\nKey Features:\nAutomatic Voltage Regulation (AVR): Stabilizes voltage.\nSurge Protection: Protects connected devices from surges.\nLCD Display: Displays battery status, load level, and other metrics.\n\nAmaron Batteries Overview\nType: Typically lead-acid (both conventional and maintenance-free) or possibly lithium-ion for some applications.\nVoltage Options: Commonly available in 12V configurations, suitable for UPS systems.\nCapacity: Various capacities (e.g., 46Ah, 100Ah, 150Ah), depending on the UPS model and required backup time.\n\nCompatibility\nSizing: Ensure the Amaron battery’s voltage matches the UPS system (e.g., a 12V battery for a 12V UPS).\nCapacity Matching: Choose a battery capacity that meets or exceeds the UPS\\\\'s requirements for runtime during power outages. Calculate based on the load you wish to support.\n\nInstallation\nConnection: Connect the Amaron battery to the UPS according to the manufacturer\\\\'s instructions. Typically, you\\\\'ll connect the positive (+) terminal to the UPS\\\\'s positive input and the negative (-) terminal to the negative input.\nSecuring: Ensure that all connections are tight and secure to prevent arcing or disconnections.\n\nPerformance and Benefits\nExtended Runtime: Using higher-capacity Amaron batteries can extend the runtime of the UPS during power outages.\nReliability: Amaron batteries are known for their durability and ability to handle deep discharges, making them suitable for UPS applications.\n\nMaintenance-Free Options: Many Amaron batteries are designed to be maintenance-free, reducing the need for regular upkeep.\n\nMaintenance\nRegular Checks: Periodically inspect the UPS and battery connections for corrosion and tightness.\nBattery Health: Monitor the battery’s voltage and overall health using a multimeter or UPS diagnostics.\nReplacement: Replace the battery as needed based on performance degradation or if the battery shows signs of failure.\n\nSafety Precautions\nVentilation: Ensure proper ventilation during operation to prevent gas buildup, especially with lead-acid batteries.\nOvercharging: Monitor charging cycles to prevent overcharging, which can lead to battery damage.\n\nConclusion\nCombining Amaron batteries with APC UPS systems can enhance your power reliability and provide an effective backup solution. Always refer to the specific user manuals for both the UPS and batteries to ensure compatibility and proper installation procedures.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "12V UPS", "UPS model", "load level", "12V battery", "gas buildup", "LCD Display", "backup time", "Key Features", "other metrics", "power outages", "battery damage", "Battery Health", "battery status", "overall health", "Regular Checks", "regular upkeep", "Amaron battery", "negative input", "positive input", "UPS diagnostics", "Voltage Options", "charging cycles", "deep discharges", "consumer models", "Sector 53 Noida", "emergency power", "APC UPS systems", "UPS applications", "Extended Runtime", "battery capacity", "Surge Protection", "APC UPS Overview", "Capacity Matching", "power reliability", "Various capacities", "12V configurations", "proper ventilation", "battery connections", "lead-acid batteries", "Compatibility Sizing", "voltage fluctuations", "Many Amaron batteries", "reliable backup power", "negative (-) terminal", "positive (+) terminal", "specific user manuals", "comprehensive overview", "performance degradation", "Installation Connection", "Maintenance-Free Options", "enterprise-level systems", "American Power Conversion", "effective backup solution", "Automatic Voltage Regulation", "Uninterruptible Power Supply", "proper installation procedures", "Safety Precautions Ventilation", "Amaron Batteries Overview Type", "higher-capacity Amaron batteries" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 68, "imageuri": "https://bizimages.withfloats.com/actual/a9793d91187943e496eb18f2e2e735b7.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/a9793d91187943e496eb18f2e2e735b7.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-18T05:42:35.656Z", "updatedon": "2024-10-18T05:42:35.656Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//amaron-batteries-apc-ups-in-sector-53-noida/68", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "Amaron Batteries Apc Ups In Sector 53 Noida", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67f4bba3414e7cbef64febbb", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Battery Testing In Sonipat", "description": "Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details:\n\nTypes of Tests:\n\nVoltage Test: Measures the battery's output voltage to check if it meets the specified range.\n\nCapacity Test: Assesses how much charge the battery can hold and deliver over time.\n\nLoad Test: Simulates real-world usage to check how the battery performs under load.\n\nInternal Resistance Test: Evaluates the battery's internal resistance, indicating its health.\n\nTools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers.\n\nFrequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures.\n\nIndicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage.\n\nProper battery testing helps in proactive maintenance, ensuring reliability and safety.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "battery performs", "battery testing", "physical damage", "multimeter hydrometer", "health tools", "sonipatbattery testing", "backup power systems", "batterys output voltage", "key details types" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 252, "imageuri": "https://bizimages.withfloats.com/actual/c913575dfda84449995beac189bf35a3.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/c913575dfda84449995beac189bf35a3.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-04-08T06:01:07.782Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//battery-testing-in-sonipat/252", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Battery Testing In Sonipat", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
required capacity?

Still searching for
required capacity?

Chat with us