Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

UNIVERSALPOWERSYSTEMF82C 6543468cae4e1df6fbef3986 Products https://locations.universalpower.co.in/bhiwadi
{ "products": [ { "_id": "670e1e0f2d20d47c6f775e23", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "ONLINE UPS REPAIRING SERVICE IN ANANDPUR BAWAL", "description": "Here\\\\'s a comprehensive guide to repairing Vertiv and Liebert online UPS systems:\n\nPreparation\n\nBefore starting the repair process, ensure you have the necessary tools, documentation, and safety precautions in place. Familiarize yourself with the UPS system\\\\'s electrical and mechanical components.\n\nTools and Equipment\n\nMultimeter\nScrewdrivers (flathead and Phillips)\nTorx driver (for some models)\nWire strippers\nPliers and wrenches\nSafety glasses and gloves\nAnti-static wrist strap or mat\nSafety Precautions\n\nEnsure the UPS system is turned off and unplugged from the power source.\nVerify the system is properly grounded.\nWear protective gear, including safety glasses and gloves.\nAvoid touching electrical components or wires.\nCommon Faults and Repairs\n\nFaulty Battery\nSymptoms: UPS not holding charge, frequent shutdowns, or battery failure.\nRepair: Replace the faulty battery with a new one of the same type and rating.\nPower Module Failure\nSymptoms: UPS not functioning, error messages, or overheating.\nRepair: Replace the faulty power module with a new one of the same type and rating.\nControl Board Failure\nSymptoms: UPS not functioning, error messages, or erratic behavior.\nRepair: Replace the faulty control board with a new one of the same type and rating.\nFan Failure\nSymptoms: Overheating, noise, or reduced airflow.\nRepair: Replace the faulty fan with a new one of the same type and rating.\nCapacitor Failure\nSymptoms: UPS not functioning, error messages, or overheating.\nRepair: Replace the faulty capacitor with a new one of the same type and rating.\nRepair Procedures\n\nDisassembly\nRemove the UPS system\\\\'s outer casing and any internal components to access the faulty part.\nDocument the wiring and connections before disconnecting them.\nComponent Replacement\nRemove the faulty component and replace it with a new one of the same type and rating.\nEnsure proper connections and wiring.\nReassembly\nReassemble the UPS system in the reverse order of disassembly.\nEnsure all connections and wiring are secure.\nTesting and Verification\n\nVisual Inspection\nVerify all components are properly installed and connected.\nCheck for any signs of physical damage or wear.\nFunctional Testing\nTurn on the UPS system and verify it\\\\'s functioning correctly.\nTest the system under various load conditions.\nPerformance Verification\nVerify the UPS system\\\\'s performance meets the manufacturer\\\\'s specifications.\nCheck for any error messages or alarms.\nDocumentation and Record-Keeping\n\nRepair Log\nDocument the repair process, including the faulty component, replacement part, and any challenges encountered.\nInclude before-and-after photos or videos.\nSystem Configuration\nUpdate the UPS system\\\\'s configuration and settings, if necessary.\nVerify the system is properly configured and functioning correctly.\nAdditional Tips and Recommendations\n\nManufacturer\\\\'s Documentation\nConsult the manufacturer\\\\'s documentation and repair guides for specific instructions and recommendations.\nTraining and Certification\nConsider obtaining training and certification from the manufacturer or a reputable third-party organization.\nPreventive Maintenance\nRegularly perform preventive maintenance tasks to minimize the risk of future repairs.\nBy following this guide, you\\\\'ll be able to repair your Vertiv or Liebert online UPS system efficiently and effectively. Remember to always follow safety precautions and manufacturer\\\\'s recommendations to ensure a successful repair.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "new one", "same type", "faulty fan", "Torx driver", "faulty part", "outer casing", "power source", "repair guides", "reverse order", "Common Faults", "future repairs", "repair process", "error messages", "Wire strippers", "ANANDPUR BAWAL", "Safety glasses", "necessary tools", "Additional Tips", "physical damage", "protective gear", "battery failure", "replacement part", "erratic behavior", "faulty component", "faulty capacitor", "successful repair", "Repair Procedures", "Visual Inspection", "proper connections", "Functional Testing", "frequent shutdowns", "comprehensive guide", "internal components", "faulty power module", "System Configuration", "Equipment Multimeter", "Fan Failure Symptoms", "faulty control board", "electrical components", "mechanical components", "specific instructions", "Component Replacement", "mat Safety Precautions", "Faulty Battery Symptoms", "various load conditions", "Anti-static wrist strap", "Performance Verification", "Record-Keeping Repair Log", "Capacitor Failure Symptoms", "Liebert online UPS systems", "preventive maintenance tasks", "ONLINE UPS REPAIRING SERVICE", "Power Module Failure Symptoms", "Control Board Failure Symptoms", "reputable third-party organization" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 51, "imageuri": "https://bizimages.withfloats.com/actual/6742f41b30604bca89ac983da9cd975e.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/6742f41b30604bca89ac983da9cd975e.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-15T07:47:27.701Z", "updatedon": "2024-10-15T07:47:27.701Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/online-ups-repairing-service-in-anandpur-bawal/51", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "ONLINE UPS REPAIRING SERVICE IN ANANDPUR BAWAL", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67de4bd9042ffb8bd0390aa7", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Powerstack battery Testing ", "description": "Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition:\n\nSteps to Test Powerstack Batteries:\n1. Visual Inspection\nCheck for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced.\n\nClean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water.\n\n2. Check Battery Voltage\nMeasure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts.\n\nFor a 24V battery, you should see a voltage of around 25.2 to 26.0 volts.\n\nUndercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty.\n\n3. Load Testing\nTest under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak.\n\nDC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff.\n\n4. Battery Charge Test\nCharge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size.\n\nMonitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger.\n\nEnd of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery.\n\n5. Conduct a Specific Gravity Test (for Lead-Acid Batteries)\nHydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty.\n\n6. Perform a Battery Health Check (Advanced)\nUse a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs.\n\nInternal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life.\n\n7. Monitor for Temperature\nBatteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system.\n\nSigns of a Failing Battery:\nRapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating.\n\nShort Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life.\n\nInconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery.\n\nPhysical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced.\n\nBattery Maintenance Tips:\nRegular Charging: Avoid deep discharges and always keep the battery charged.\n\nEnvironmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures.\n\nPeriodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly.\n\nUse the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging.\n\nConclusion:\nBattery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 248, "imageuri": "https://bizimages.withfloats.com/actual/7f2c78a976e246efbe70882f742a421a.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/f8db1555dfa447dbb73d3446e6b45940.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-22T05:34:17.551Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/powerstack-battery-testing-/248", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Powerstack battery Testing ", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d8fef0033d2a4a9b17171a", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "HPL Lithium-Ion Battery Energy Storage System", "description": "The HPL Lithium-Ion Battery Energy Storage System is a type of energy storage technology that uses lithium-ion batteries to store and manage electrical energy. These systems are typically used to store excess energy generated from renewable sources like solar and wind or from the grid, and release it when needed to help stabilize energy supply and demand.\n\nHere’s a breakdown of the key components and features that are generally associated with Lithium-Ion Battery Energy Storage Systems (BESS), including those from HPL or similar manufacturers:\n\nKey Features:\nLithium-Ion Technology:\n\nLithium-ion batteries are favored for their high energy density, long cycle life, and efficient performance. They are commonly used in applications like electric vehicles, grid storage, and consumer electronics.\nEnergy Storage:\n\nThese systems store electrical energy in lithium-ion battery packs and release it during periods of high demand, or when renewable energy production is low (e.g., on cloudy days for solar energy systems).\nEfficiency:\n\nLithium-ion batteries typically offer high efficiency in terms of energy conversion, with round-trip efficiencies often exceeding 90%. This means that most of the stored energy is usable when discharged.\nModular Design:\n\nHPL and other manufacturers often design their battery systems with modularity in mind. This means that the system can be scaled to fit a variety of needs, from residential to commercial and industrial applications.\nGrid Integration:\n\nThese energy storage systems are commonly integrated with the electrical grid. They can help balance grid frequency and voltage, provide backup power during outages, and support the integration of renewable energy sources by smoothing fluctuations in supply.\nBattery Management System (BMS):\n\nThe BMS ensures the safety, performance, and longevity of the battery by monitoring the state of charge (SOC), temperature, and other critical parameters. It can also prevent overcharging, over-discharging, and overheating.\nApplications:\n\nResidential Use: Homeowners can use these systems to store solar energy for use during the night or power outages.\nCommercial & Industrial Use: Businesses can use these systems to reduce demand charges or to provide backup power.\nGrid-Scale: Large energy storage systems can be used to stabilize the grid and facilitate the integration of renewable energy at a larger scale.\nAdvantages:\nSustainability: By storing renewable energy, these systems contribute to reducing carbon footprints and dependence on fossil fuels.\nFlexibility: They can be used in a wide range of applications, including residential, commercial, and large-scale energy storage.\nCost Savings: Especially in commercial applications, they can help reduce energy costs by managing peak demand and reducing reliance on expensive grid power during peak periods.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "exceeding 90", "commercial applications", "commonly integrated", "residential commercial", "systems contribute", "battery systems", "peak periods", "wide range", "critical parameters", "safety performance", "bms ensures", "smoothing fluctuations", "roundtrip efficiencies", "cloudy days", "efficient performance", "key components", "reducing reliance", "electrical grid", "high demand", "demand heres", "lithiumion batteries", "stored energy", "energy conversion", "renewable sources", "renewable energy", "store solar energy", "overheating applications residential", "energy storage systems", "lithiumion battery packs", "stabilize energy supply", "renewable energy sources", "expensive grid power", "managing peak demand", "balance grid frequency", "manage electrical energy", "storing renewable energy", "renewable energy production", "reducing carbon footprints", "reduce demand charges", "reduce energy costs", "energy storage technology", "fossil fuels flexibility", "prevent overcharging overdischarging", "charge soc temperature" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 237, "imageuri": "https://bizimages.withfloats.com/actual/808d1c9b815a4502bb250db25f1fb1a1.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/808d1c9b815a4502bb250db25f1fb1a1.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-18T05:04:48.76Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/hpl-lithium-ion-battery-energy-storage-system/237", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "HPL Lithium-Ion Battery Energy Storage System", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d5328fdb7fc0f04f83af80", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Battery Replacement In Faridabad", "description": "Battery replacement is a common maintenance task for various types of power systems, including solar systems, electric vehicles (EVs), UPS (uninterruptible power supplies), and other battery-powered devices. The process and requirements can vary depending on the type of battery used. Below, I'll provide an overview of common types of batteries and the replacement process for each.\n\nTypes of Batteries and Their Replacement Process\n1. Lead-Acid Batteries\nCommon Types:\nFlooded Lead-Acid (FLA): Requires regular maintenance, such as adding distilled water to the cells.\nSealed Lead-Acid (SLA): Maintenance-free and does not require water addition.\nAbsorbent Glass Mat (AGM): A type of SLA battery where the electrolyte is absorbed in glass mats.\nGel Lead-Acid Batteries: These use a gel electrolyte instead of liquid and are often used in deep-cycle applications.\nReplacement Process:\nTurn off the system: Ensure the system is powered off, and disconnect it from the grid or load.\nSafety precautions: Wear protective gear, including gloves and goggles, since lead-acid batteries contain sulfuric acid and produce flammable gases.\nDisconnect terminals: Always disconnect the negative terminal first, followed by the positive terminal.\nRemove old batteries: Lift and remove the batteries carefully, especially if they're heavy.\nClean battery terminals: Inspect and clean the terminals, and remove any corrosion using a mixture of baking soda and water.\nInstall new batteries: Place the new battery in the same configuration as the old one, then reconnect the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system and check the voltage and charging status.\nMaintenance Tips:\nRegularly check the electrolyte levels in flooded batteries.\nClean terminals and ensure the battery box or tray is secure.\n2. Lithium-Ion Batteries\nCommon Types:\nLithium Iron Phosphate (LiFePO4): Common in solar systems and EVs due to its high efficiency and long lifespan.\nLithium Nickel Manganese Cobalt (NMC): Found in high-power applications such as EVs and power tools.\nLithium Manganese (LiMn2O4): Often used in EVs, power tools, and other high-power applications.\nLithium Polymer (LiPo): Typically used in small devices like drones, power banks, and mobile phones.\nReplacement Process:\nTurn off the system: Disconnect the power source or system.\nSafety precautions: Lithium-ion batteries are generally safe but should be handled carefully to avoid overheating, short-circuiting, or damage.\nDisconnect terminals: Start by disconnecting the negative terminal followed by the positive terminal.\nRemove the old battery: Lithium-ion batteries are typically lighter and easier to replace than lead-acid batteries.\nInstall the new battery: Place the new battery in the same orientation and secure it.\nReconnect terminals: Attach the positive terminal first, followed by the negative terminal.\nCheck the system: Power on the system, and monitor the battery's charging and discharging to ensure it's working properly.\nMaintenance Tips:\nLithium-ion batteries require minimal maintenance, but always ensure they are charged within the recommended voltage range.\nBattery Management System (BMS) should be monitored to ensure proper functioning and safety.\n\nConclusion:\nBattery replacement depends on the type of battery and the application. For solar systems, lead-acid, and lithium-ion are the most common, each requiring specific attention during installation.\n\nLead-acid batteries need regular maintenance, especially flooded types.\nLithium-ion batteries are easier to replace and have a longer lifespan with minimal maintenance.\nAlways follow safety guidelines when handling batteries, especially lead-acid or lithium-ion, and ensure proper recycling and disposal of old batteries to avoid environmental hazards.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "system disconnect", "common types", "system ensure", "replacement process", "battery place", "battery box", "electrolyte levels", "gel electrolyte", "sla battery", "battery replacement", "system power", "handling batteries", "longer lifespan", "batterys charging", "typically lighter", "handled carefully", "generally safe", "small devices", "highpower applications", "high efficiency", "evs due", "batteries place", "baking soda", "batteries carefully", "batteries lift", "sulfuric acid", "ill provide", "vary depending", "batterypowered devices", "faridabadbattery replacement", "minimal maintenance", "regular maintenance", "power source", "leadacid batteries", "power systems", "solar systems", "positive terminal", "water install", "negative terminal", "battery lithiumion batteries", "leadacid batteries install", "reconnect terminals attach", "positive terminal remove", "solar systems leadacid", "evs power tools", "negative terminal check", "common maintenance task", "installation leadacid batteries", "ensure proper recycling", "ensure proper functioning", "drones power banks", "adding distilled water", "avoid environmental hazards", "follow safety guidelines", "requiring specific attention", "avoid overheating shortcircuiting" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 231, "imageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/756776d6ee8c4f8582dbba63d6dc5e49.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-15T07:55:59.544Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/battery-replacement-in-faridabad/231", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Battery Replacement In Faridabad", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d52d8a4507f670f3d4fa58", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Emerson 3-Phase Ups In Manesar", "description": "Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues.\n\nKey Features of Emerson 3-Phase UPS:\nPower Capacity:\n\n3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model.\nSuitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings.\nTechnology:\n\nDouble Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging.\nEfficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs.\nBattery Management: Integrated advanced battery management for monitoring health, charge, and backup times.\nHigh Availability:\n\nDesigned to provide reliable power for mission-critical applications.\nHot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply.\nScalability: Many models allow for modular expansion, meaning you can add additional capacity as needed.\nInput/Output Voltage:\n\nInput Voltage: Common input voltages are 380V, 400V, and 415V (3-phase).\nOutput Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards.\nPower Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency.\nAdvanced Features:\n\nLCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring.\nRemote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics.\nBypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime.\nDesign and Durability:\n\nCompact Design: Many models are designed to be space-efficient without compromising on power or cooling needs.\nRack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs.\nThermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating.\nApplications:\n\nData Centers: Ensures uptime for servers and networking equipment.\nIndustrial Equipment: Protects critical machinery and automated systems from power failures.\nTelecommunications: Keeps communication systems running without interruption.\nHospitals: Supports life-saving equipment and systems that require constant power.\nCommercial Buildings: Ensures backup power for office systems and equipment.\nMaintenance and Service:\n\nSmart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required.\nServiceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition.\nProactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations.\nPopular Models:\nEmerson (now part of Vertiv) offers various UPS models under different series, such as:\n\nVertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications.\nVertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability.\nVertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications.\nAdvantages of Emerson 3-Phase UPS:\nHigh Reliability: Ensures critical equipment remains powered during power failures or fluctuations.\nAdvanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility.\nEnergy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact.\nScalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand.\n\nConclusion:\nEmerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "800 kva", "10 kva", "models batteries", "equipment maintenance", "small office", "380v 400v", "largescale facilities", "ups models", "excellent solutions", "easily expand", "data centers", "remote monitoring", "service contracts", "comprehensive support", "alert users", "realtime alerts", "remote access", "realtime data", "model suitable", "wide range", "ups remains", "office systems", "automated systems", "offers scalability", "vertiv offers", "bypass mode", "industrial commercial", "robust design", "higher depending", "critical infrastructure", "power failures", "monitoring health charge", "modular ups system", "advanced cooling systems", "emerson ups systems", "ups systems typically", "ensure uninterrupted operation", "3phase systems depending", "critical infrastructure applications", "power failures telecommunications", "emerson 3phase ups", "communication systems running", "environmental impact scalability", "industrial applications advantages", "vertiv liebert ita2", "diagnostics bypass capability", "high power factor", "provide reliable power", "power capacities generally", "provide uninterrupted power", "tower formats depending", "durability compact design", "avoid downtime design", "require high uptime", "flexibility energy efficiency", "diagnostic tools faults", "maintain efficient operation", "add additional capacity", "modular expansion meaning", "reduce energy consumption" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 229, "imageuri": "https://bizimages.withfloats.com/actual/187708a304fa44f1b41acc0e625a7a30.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/187708a304fa44f1b41acc0e625a7a30.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-15T07:34:34.549Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/emerson-3-phase-ups-in-manesar/229", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Emerson 3-Phase Ups In Manesar", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67d13de22912ddb97fcecda8", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Maintenance Tips for UPS Systems and Batteries​", "description": "Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips:\n\n1. Regular Inspection\nVisual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion.\nConnections: Ensure that all connections are secure and free from dust and corrosion.\n2. Battery Maintenance\nBattery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load.\nClean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting.\nCheck Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed.\n3. Environmental Considerations\nTemperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly.\nVentilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow.\n4. Regular Testing\nSelf-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature.\nLoad Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage.\n5. Firmware and Software Updates\nKeep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security.\nMonitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues.\n6. Battery Replacement\nFollow Manufacturer Guidelines: Replace batteries according to the manufacturer\\'s recommendations, typically every 3-5 years for lead-acid batteries.\nDispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety.\n7. Load Management\nAvoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life.\nBalanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded.\n8. Documentation\nKeep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance.\n9. Professional Maintenance\nSchedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems.\n10. User Training\nEducate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "35 years", "maintenance tips", "ups system", "ups systems", "rated capacity", "distilled water", "power outage", "issues encountered", "records maintain", "overloaded 8 documentation", "single outlet", "receive alerts", "functioning correctly", "enclosed spaces", "baking soda", "check voltage", "improve performance", "ensure terminals", "load evenly", "required load", "battery tester", "software updates", "corrosion connections ensure", "ups monitoring software", "leadacid batteries dispose", "battery terminals clean", "load clean terminals", "track performance metrics", "ensuring reliable performance", "total load connected", "install firmware updates", "security monitoring software", "manufacturers recommendations typically", "electrolyte levels regularly", "physical damage leaks" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 221, "imageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/f2806dc2e20e4e888003d867a3c3ab17.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-03-12T07:55:14.561Z", "updatedon": "0001-01-01T00:00:00Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/maintenance-tips-for-ups-systems-and-batteries-/221", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Maintenance Tips for UPS Systems and Batteries​", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "672b119afa30a93a44b20cf3", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Vertiv 6kVA PowerBank UPS IN FARIDABAD", "description": "The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers.\n\nAlthough \"PowerBank\" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings.\n\nKey Features and Specifications:\n\n1. Topology:\nDouble Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power.\nThe On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter.\n\n2. Power Rating:\n6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment).\n\n3. Output Power:\nOutput Power: 4.8 kW to 5.4 kW (depending on load and configuration)\n\n4. Input and Output Specifications:\nInput Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode.\nOutput Voltage: 230V ± 2% (standard in most countries)\n\n5. Waveform Type:\nPure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems.\n\n6. Battery Configuration:\nBattery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries.\nBattery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities.\nThe system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times.\nExternal Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period.\n\n7. Charging Time:\nTypically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions.\n\n8. Backup Time (Runtime):\nThe backup time can range from 20 minutes to several hours, depending on the load.\nFor example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime.\nA full load of 6kVA will typically provide 10-15 minutes of backup time.\nIf the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages.\n\n9. Cooling System:\nThe UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use.\n\n10. Display and Monitoring:\nLCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters.\nAudible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults.\nSmart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS.\n\n11. Connectivity and Interfaces:\nUSB/Serial Ports: For communication with a connected computer or server for monitoring and management.\nSNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices.\nDry Contact Interface: Allows integration with building management or alert systems.\nOptional Software: Available for automated shutdown in the event of prolonged power outages, and event logging.\n\n12. Form Factor:\nTower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup.\n\n13. Additional Features:\nOverload Protection: Safeguards against exceeding the UPS's rated capacity.\nShort-Circuit Protection: Provides defense against electrical faults.\nAutomatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.\n", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "3 kVA", "5.4 kW", "4.8 kW", "The UPS", "50% load", "full load", "4-6 hours", "medium to", "20 minutes", "SNMP Slots", "brand name", "UPS status", "tower setup", "LCD Display", "exact model", "low battery", "Key Features", "data centers", "extended use", "battery size", "Battery Type", "battery mode", "Output Power", "load capacity", "event logging", "10-15 minutes", "system faults", "several hours", "Waveform Type", "highest level", "Charging Time", "alert systems", "Input Voltage", "12V batteries", "power failure", "Battery Banks", "specific model", "Audible Alarms", "most countries", "marketing term", "longer runtime", "longer periods", "Output Voltage", "12. Form Factor", "series features", "extended period", "VRLA) batteries", "2. Power Rating", "network systems", "On-Line topology", "extended runtime", "user preferences", "USB/Serial Ports", "Sealed Lead-Acid", "general overview", "large businesses", "Battery Capacity", "critical systems", "extended outages", "wide input range", "remote monitoring", "9. Cooling System", "electrical faults", "Optional Software", "networked devices", "Double Conversion", "IT infrastructure", "higher capacities", "continuous supply", "automated shutdown", "connected computer", "critical equipment", "high-quality power", "zero transfer time", "Overload Protection", "connected equipment", "sensitive equipment", "building management", "extended protection", "Additional Features", "medium server rooms", "longer backup times", "voltage fluctuations", "fan-assisted cooling", "medium-sized systems", "pure sinewave output", "larger power demands", "real-time information", "Battery Configuration", "Output Specifications", "Dry Contact Interface", "battery backup systems", "optimal battery health", "incoming utility power", "External Battery Packs", "continuous power supply", "prolonged power outages", "rackmount configurations", "environmental conditions", "high-demand environments", "Short-Circuit Protection", "Smart Battery Management", "consistent power quality", "external battery modules", "Valve-Regulated Lead-Acid", "higher power applications", "lower-quality UPS systems", "extended battery runtimes", "other important parameters", "efficient heat dissipation", "Automatic Voltage Regulation", "integrated external batteries", "The Vertiv 6kVA PowerBank UPS", "detailed product specifications", "Simple Network Management Protocol", "additional external battery cabinets", "Line-Interactive power protection solutions" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 161, "imageuri": "https://bizimages.withfloats.com/actual/76ce7c6b4c744ba9b94ab60a79c3031e.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/76ce7c6b4c744ba9b94ab60a79c3031e.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-11-06T06:50:02.976Z", "updatedon": "2024-11-06T06:50:02.976Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/vertiv-6kva-powerbank-ups-in-faridabad/161", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "6 KVA POWERBANK", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6729aac1174715dbab62679f", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Quanta 12V 7Ah Battery In Bhogipur Sonipat", "description": "The Amaron Quanta 12V 7Ah is a sealed lead-acid (SLA) battery commonly used in applications such as backup power systems, uninterruptible power supplies (UPS), security systems, and various other low-power applications. Here\\'s a breakdown of its details:\nKey Specifications:\nNominal Voltage:\n\n12 Volts (V)\nCapacity:\n\n7 Ampere-hours (Ah) at a rate of 20 hours (i.e., the battery can provide 0.35A of current for 20 hours).\nThis is typical for deep-cycle applications, providing reliable performance over an extended period.\nBattery Type:\n\nSealed Lead-Acid (SLA):\nMaintenance-free design.\nCan be installed in any orientation, though upright is recommended for optimal performance.\nSuitable for both float and cyclic applications.\nDimensions:\n\nLength: 151 mm (5.94 inches)\nWidth: 65 mm (2.56 inches)\nHeight: 95 mm (3.74 inches)\nWeight: Approx. 2.3 kg (5.07 lbs)\nTerminal Type:\n\nF1 Faston connectors (0.187” wide), which are commonly used for quick connections.\nOperating Temperature:\n\nDischarge: -15°C to +50°C (5°F to 122°F)\nCharge: 0°C to +40°C (32°F to 104°F)\nFloat Life:\n\nTypically 3-5 years in float (backup power) applications.\nSelf-Discharge:\n\nSLA batteries typically have a low self-discharge rate of about 3-5% per month at 25°C, meaning they retain their charge relatively well when not in use for extended periods.\nCharge Voltage:\n\nStandard Charging Voltage: 13.5 to 13.8V (constant voltage charging)\nMaximum Charging Voltage: 14.4V\nRecommended Float Charging Voltage: 13.5V\nCycle Life:\n\nTypically offers about 200-300 cycles at 100% discharge.\nThe cycle life increases with lower depth of discharge (DoD).\nApplications:\nUPS Systems: To provide backup power for computers, networking equipment, and other devices.\nSolar Power Systems: As a small energy storage option in off-grid or backup solar systems.\nAlarm Systems: For providing power in case of a mains failure.\nElectric Vehicles & Mobility Scooters: In some cases for small EVs or battery-powered mobility solutions.\nPower Tools & Other Low Power Systems: To provide compact, reliable energy for tools and other devices.\nSafety & Maintenance:\nMaintenance-Free: No need to add water or maintain the electrolyte levels, as the battery is sealed.\nOvercharge Protection: Built-in mechanisms to prevent overcharging that could lead to damage or overheating.\nOvercurrent Protection: Built-in to prevent damage due to short circuits or excessive current.\nWarranty:\nTypically 1-2 years depending on the brand and country of purchase.\nStorage & Handling:\nStorage Temperature: Store in a cool, dry place, ideally between 15°C and 25°C.\nDo not store in a fully discharged state, as this can significantly reduce the lifespan of the battery.\nRegular Maintenance: If not in use for extended periods, check the battery voltage periodically and recharge it if necessary.\nThe Amaron Quanta 12V 7Ah battery is designed for reliability and versatility, suitable for a variety of applications that require backup power or a small energy storage solution.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "95 mm", "65 mm", "2.3 kg", "151 mm", "20 hours", "12 Volts", "1-2 years", "3-5 years", "small EVs", "Float Life", "lower depth", "Power Tools", "UPS Systems", "SLA) battery", "Battery Type", "SLA batteries", "mains failure", "Terminal Type", "Alarm Systems", "other devices", "5V Cycle Life", "100% discharge", "7 Ampere-hours", "Charge Voltage", "short circuits", "200-300 cycles", "extended period", "Nominal Voltage", "battery voltage", "cool, dry place", "sealed lead-acid", "Bhogipur Sonipat", "security systems", "excessive current", "Electric Vehicles", "quick connections", "Mobility Scooters", "electrolyte levels", "Key Specifications", "Regular Maintenance", "cyclic applications", "optimal performance", "Storage Temperature", "Solar Power Systems", "networking equipment", "reliable performance", "backup power systems", "backup solar systems", "F1 Faston connectors", "Overcharge Protection", "Operating Temperature", "Overcurrent Protection", "Float Charging Voltage", "Maintenance-free design", "deep-cycle applications", "low self-discharge rate", "Other Low Power Systems", "Maximum Charging Voltage", "compact, reliable energy", "constant voltage charging", "Standard Charging Voltage", "backup power) applications", "small energy storage option", "small energy storage solution", "uninterruptible power supplies", "The Amaron Quanta 12V 7Ah battery", "battery-powered mobility solutions", "various other low-power applications" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 140, "imageuri": "https://bizimages.withfloats.com/actual/6a737164a93f41b0ad1c485b77f6ef13.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/6a737164a93f41b0ad1c485b77f6ef13.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-11-05T05:18:57.888Z", "updatedon": "2024-11-05T05:18:57.888Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI//amaron-quanta-12v-7ah-battery-in-bhogipur-sonipat/140", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Battery", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "67189ab9762edbb288f82b42", "fptag": "UNIVERSALPOWERSYSTEMF82C", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Amaron Quanta 100Ah battery In Chirhara", "description": "The Amaron Quanta 100Ah battery is designed for reliable power backup, particularly in applications like telecom, UPS systems, and industrial use. Here are the key details:\n\nSpecifications\nVoltage: 12V\nCapacity: 100Ah\nType: Sealed Maintenance Free (SMF) Lead-Acid Battery\nTechnology: Advanced lead-calcium technology for enhanced performance.\n\nKey Features\nMaintenance-Free: No need for regular electrolyte topping, making it user-friendly.\nLong Life: Designed for extended service life with minimal degradation over time.\nHigh Durability: Built to withstand harsh operating conditions, including temperature fluctuations.\nDeep Discharge Capability: Suitable for applications that require deep cycling.\nVibration Resistance: Can endure vibrations, making it ideal for industrial environments.\n\nApplications\nTelecommunications: Provides backup power for telecom equipment and infrastructure.\nUPS Systems: Used in uninterruptible power supplies for critical loads.\nSolar Energy: Suitable for solar applications where energy storage is necessary.\nIndustrial Use: Powers machinery and equipment requiring reliable energy.\nPhysical Characteristics\nDimensions: Approximately 330 mm x 170 mm x 220 mm (length x width x height).\nWeight: Around 30-35 kg (exact weight may vary slightly).\n\nSafety Features\nValve-Regulated: Prevents leakage and spillage of electrolytes.\nThermal Management: Built to operate safely within specified temperature ranges.\nShort Circuit Protection: Designed to disconnect safely in the event of a short circuit.\n\nWarranty\nTypically comes with a warranty of 18 months to 2 years, depending on usage and application.\n\nMaintenance Tips\nAlthough maintenance-free, check terminals for cleanliness and tightness periodically.\nEnsure the battery is kept in a well-ventilated area to avoid overheating.\n\nConclusion\nThe Amaron Quanta 100Ah battery is a reliable solution for a variety of applications, offering excellent performance with minimal maintenance. ", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "220 mm", "170 mm", "330 mm", "2 years", "30-35 kg", "18 months", "Long Life", "100Ah Type", "key details", "UPS systems", "exact weight", "Solar Energy", "12V Capacity", "deep cycling", "Key Features", "backup power", "energy storage", "critical loads", "industrial use", "ventilated area", "High Durability", "reliable energy", "Powers machinery", "Maintenance Tips", "telecom equipment", "reliable solution", "solar applications", "temperature ranges", "Thermal Management", "minimal degradation", "minimal maintenance", "Vibration Resistance", "enhanced performance", "excellent performance", "reliable power backup", "Safety Features Valve", "extended service life", "Specifications Voltage", "industrial environments", "Sealed Maintenance Free", "temperature fluctuations", "Short Circuit Protection", "Deep Discharge Capability", "harsh operating conditions", "regular electrolyte topping", "uninterruptible power supplies", "The Amaron Quanta 100Ah battery", "Advanced lead-calcium technology", "SMF) Lead-Acid Battery Technology", "Physical Characteristics Dimensions" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 99, "imageuri": "https://bizimages.withfloats.com/actual/bb3d5a7a66184e7385bf973ffe966e42.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/bb3d5a7a66184e7385bf973ffe966e42.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-23T06:42:01.709Z", "updatedon": "2024-10-23T06:42:01.709Z", "buyonlinelink": null, "producturl": "https://LOCATIONS.UNIVERSALPOWER.CO.IN/BHIWADI/products/amaron-quanta-100ah-battery-in-chirhara/99", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Battery", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
shutdowns overheating?

Still searching for
shutdowns overheating?

Chat with us