3 KVA
SB MODEL & LB MODEL
The Vertiv 3kVA UPS models in the SB (Standby) and LB (Line-Interactive) series are designed to provide power protection and backup for medium-sized equipment or small-to-medium office environments, server rooms, and critical infrastructure. Below are the detailed specifications and features for each of these series in the 3kVA range.
1. Vertiv 3kVA SB (Standby) Series UPS
The SB Series for 3kVA is a basic uninterruptible power supply solution. The Standby topology is typically the most cost-effective option, ideal for environments that require minimal backup time and surge protection without sophisticated power regulation.
Key Features:
Topology: Standby (Off-line) UPS
Power Rating: 3kVA / 3000VA
Output Power: 1800W - 2400W (varies by model)
Input Voltage: 160V - 280V (wide voltage range)
Output Voltage: 230V ± 10% (standard for most regions)
Waveform Type: Simulated Sinewave (approximate sinewave output)
Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid)
Battery Capacity: 12V, 9Ah, 12Ah, or higher (depending on model)
Charging Time: Typically 4-8 hours for a full charge
Backup Time (Runtime): Provides backup for 5-20 minutes depending on load (e.g., 60-70% load)
Cooling: Fan-assisted cooling for heat dissipation
Interfaces: USB/Serial ports (some models include monitoring software)
Form Factor: Typically Tower form factor
Additional Features:
Surge protection (for protection against power spikes)
Overload protection and short-circuit protection
Battery and overload indicators (LED and audible alarms)
Optional software for remote monitoring and automatic shutdown
Compact design for easier deployment in small-to-medium businesses, home offices, or workstations
Ideal Use Case:
Home offices and small businesses needing reliable backup power and surge protection
Low power devices like workstations, point-of-sale (POS) systems, small networking equipment
Environments where minimal power conditioning and voltage regulation are required
2. Vertiv 3kVA LB (Line-Interactive) Series UPS
The LB Series for 3kVA uses a Line-Interactive topology, providing more advanced protection and efficiency, making it ideal for environments where power quality and stability are essential. The line-interactive design offers better Automatic Voltage Regulation (AVR), correcting voltage fluctuations without switching to battery power.
Key Features:
Topology: Line-Interactive
Power Rating: 3kVA / 3000VA
Output Power: 2100W - 2700W (varies by model)
Input Voltage: 140V - 300V (wider input range compared to the SB series)
Output Voltage: 230V ± 10% (standard for most regions)
Waveform Type: Simulated Sinewave (or Pure Sinewave on some models)
Battery Type: Sealed Lead-Acid (SLA) or VRLA
Battery Capacity: Typically 12V, 9Ah, 12Ah, or higher (depending on model)
Charging Time: 4-6 hours to fully charge the battery
Backup Time (Runtime): 10-30 minutes depending on the load (e.g., for 50-60% load)
Cooling: Fan-assisted cooling
Interfaces: USB/Serial ports (for monitoring and management software)
Form Factor: Tower or Rackmount (depending on the specific model)
Additional Features:
Automatic Voltage Regulation (AVR): Corrects minor voltage fluctuations without using battery power
Cold Start Capability: Can start without mains power (useful during power failures)
LCD Display (on some models) to show real-time UPS status, battery level, and load information
Overload, short-circuit, and low-battery protection
Smart battery management for enhanced performance and extended battery life
Audible alarms for power events (e.g., low battery, overload, fault)
Smart monitoring and remote management with optional software for logging events and automatic shutdown during extended power outages
Ideal Use Case:
Small-to-medium-sized servers, network equipment, and critical infrastructure requiring more advanced power protection
Environments needing consistent power quality, such as server rooms, medical equipment, and point-of-sale systems
Small businesses with sensitive equipment that requires more stable voltage levels and longer backup time
Send