Delhi
+918076792323

'repair work'

Items tagged with 'repair work'

product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message
product image
Online Ups Amc Repair & Services

As a leading provider of UPS services, we understand the criticality of uninterrupted power supply for your business. Our team of highly skilled technicians is dedicated to delivering efficient and reliable online UPS services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . With our expertise and experience, we offer comprehensive solutions for online UPS installation, maintenance, and repair. Whether you are looking for a new installation or need assistance with troubleshooting and repairs, we have got you covered. UPS Repair & Services In Manesar We specialize in UPS Repair & Services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . offering professional troubleshooting and repair. Our team is equipped to handle issues of any scale, ensuring your UPS systems are always in top working condition. Maintenance Contract After entering into AMC, the contract will do the 1st preventive maintenance to check UPS condition, Healthy and working UPS only will be considered under AMC and also Faulty will be repaired on chargeable basis before considering it under AMC. If the batteries are found faulty at the time of inspection it will have to be replaced before taking it under AMC. Any make, any capacity (expect Vertiv & Emerson) Unlimited Break Down calls (Except Wire wound components, batteries, transformers). Includes 100% labor and travel coverage 6 days/week, 8 hours/day. Performed by ACCESS factory trained Customer Engineers. Break down calls – UNLIMITED. Subject to all Terms & Conditions as noted in the ACCESS Maintenance Agreement. 8 Hours Turnaround Time. Preventive Service Preventive Measurement : 4 PM per year Cleaning up of Unit, Visual Inspection tocheck any deformation. Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current. Checking and Adjustment (If needed) of Control parameters on different PCBs. Tightness of all connections, if shut down possible. Functional Checking up of Rectifier section. Functional Checking up of Inverter section. Functional Checking up of Static Switch Section. With customer approval, perform operational tests of the system including unit transfer and battery discharge. Maintaining the posted checklist at the client place. Battery Health checks with Multi Meter. Battery AMC Introducing for the very first time in the Industry “Battery AMC”, wherein you get your additional 3rd year warranty only @15% of your previous pay for the batteries. Quanta Amaron Make of battery is only included in AMC. Battery should be within the warranty period. Currently AMC will be carried forward only for Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . Region. UPS Renting Cost Effective: Rental UPS is very cost effective, you can save on huge project costs. Power Stability: Provides stable power continuously and saves all your expensive equipment from Power Surges. No Minimum Requirements: Online UPS available from 1KVA to 600 KVA on rent for short & long term. No Maintenance Cost: UPS Rental helps you save on maintenance & Servicing cost. Customisable: Special customization facility available for your specific needs. No Power Cuts: Battery life is always ON, due to immediate replacement facility. Maintenance Contracts On line ups in each kVA rating and battery backup system are very sensitive issues and so it should be taken care utmost to enhance the life of UPS system and battery life for almost 99% up time during performance. Access Power Link is a leader in this market for 25 years having expertise and experience in the field to ensure hassle-free UPS AMC services on PAN INDIA level. UPS Servicing To Suit You Our response time is the time to get to site, not the time for a callback Travel and labour is included in all contract prices unless not required Our technical support is offered by actual UPS experts, not a call centre. Our inclusive parts contracts include ALL parts not just “consumables”. Our preventative maintenance includes multipoint checks not just visuals. We offer different plans to pass on savings during normal working hours.

Send Message
product image
Apc Ups Repairing In Jawahar Colony Faridabad

Repairing an APC UPS (Uninterruptible Power Supply) involves troubleshooting and addressing common issues that can arise over time. Here’s a comprehensive guide to help you diagnose and repair your APC UPS: Safety Precautions Disconnect Power: Always unplug the UPS before performing any repairs or inspections. Use PPE: Wear safety goggles and gloves to protect against electric shock. Work in a Ventilated Area: Ensure good airflow to prevent overheating. Common Issues and Solutions 1. UPS Won\\'t Turn On Check Power Source: Ensure the UPS is plugged in and the outlet is functional. Test the power cord for damage. Battery Issues: Inspect the battery for swelling, leaks, or corrosion. Use a multimeter to check battery voltage; if it\\'s significantly low, it may need replacement. 2. Battery Replacement Identify Battery Type: Refer to the user manual for the specific battery model. Remove the Old Battery: Open the UPS case (usually requires a screwdriver). Disconnect the old battery, noting the connections. Install the New Battery: Connect the new battery securely. Close the UPS case and ensure all screws are tightened. 3. Overheating Check Ventilation: Ensure that the UPS is in a well-ventilated area. Clear any obstructions around vents. Inspect Fans: Check if the internal fans are operational. Clean any dust accumulation. 4. Frequent Alarms or Beeping Load Issues: Ensure that the connected load does not exceed the UPS capacity. Disconnect non-essential devices and see if the alarm stops. Battery Health: Run a self-test (if your model supports it) to check battery status. 5. Self-Test Failure Check Battery Voltage: Use a multimeter to check the voltage of the battery. Replace if below the recommended level. Internal Issues: If the self-test consistently fails, the internal circuitry might need inspection by a professional. Tools and Equipment Needed Multimeter (for voltage checks) Screwdriver set Replacement batteries (as needed) Cleaning cloth or compressed air (for dust removal) Safety equipment (gloves, goggles) General Repair Steps Visual Inspection: Check for any visible signs of damage, such as burnt components or damaged connectors. Inspect for loose wires and connections. Testing Components: Batteries: Measure the voltage and ensure it\\'s within specifications. Fuses: Check fuses for continuity. Replace blown fuses as needed. Fans and Circuits: Ensure fans are operational and listen for unusual noises. Reassembly: After repairs, carefully reassemble the UPS. Ensure all screws and connections are secure before powering on. Testing the UPS: Once reassembled, plug in the UPS and perform a test by connecting a load. Monitor the UPS for any abnormal behavior. Conclusion Repairing an APC UPS can often be straightforward, particularly when it comes to replacing batteries or troubleshooting common issues. However, if the problem persists or if you are unsure about the repair process, it’s advisable to contact a professional technician or the manufacturer for support. Always refer to the specific user manual for detailed instructions related to your UPS model.

Send Message
product image
Amaron Batteries Repairing And Charging In sohna sector 36 Gurgaon

Repairing and charging Amaron batteries (or any lead-acid battery) requires caution and adherence to safety procedures. Here’s a comprehensive guide on how to repair and charge Amaron batteries: Safety Precautions Personal Protective Equipment (PPE): Always wear safety goggles and gloves. Ventilation: Work in a well-ventilated area to avoid inhaling harmful gases. Avoid Short Circuits: Be careful with tools and connections to prevent sparks or short circuits. Tools and Equipment Needed Multimeter (for checking voltage and condition) Battery charger compatible with lead-acid batteries Battery terminal cleaner or wire brush Distilled water (if applicable, for batteries that can be serviced) Insulation tape Safety equipment (gloves, goggles) Steps to Repair and Charge Amaron Batteries 1. Inspect the Battery Check for physical damage, such as cracks or leaks. Inspect terminals for corrosion. Clean terminals with a wire brush if necessary. 2. Test the Battery Use a multimeter to check the voltage. A fully charged 12V battery should read around 12.6 to 12.8 volts. If the voltage is significantly lower (e.g., below 12 volts), the battery may need charging or could be damaged. 3. Charging the Battery Select the Right Charger: Use a smart charger or a lead-acid battery charger that matches the battery’s specifications. Connect the Charger: Connect the positive (+) terminal of the charger to the positive terminal of the battery. Connect the negative (-) terminal of the charger to the negative terminal of the battery. Set the Charger: Choose the appropriate charging mode (usually a slow charge is best for lead-acid batteries). Monitor Charging: Charging time will vary; typically, it can take several hours to overnight. Monitor the charging process. 4. Check Battery Condition After Charging Once fully charged, use the multimeter to measure the voltage again. Perform a load test (if available) to ensure the battery can hold a charge under load. 5. Repairing Cells (if applicable) For Serviceable Batteries: If the battery has removable caps: Check the electrolyte level; add distilled water if needed. Ensure the specific gravity of the electrolyte is within the acceptable range (use a hydrometer). Re-seal the Caps: Make sure all caps are securely in place after checking. 6. Final Inspection and Reinstallation Ensure all connections are clean and secure. Reinstall the battery in the vehicle, connecting the positive terminal first, followed by the negative terminal. Use insulation tape to secure any exposed connections. Additional Tips Avoid Overcharging: Overcharging can damage the battery and reduce its lifespan. Always use a charger with an automatic shut-off feature. Regular Maintenance: Periodically check battery health, clean terminals, and keep the battery charged to prolong its life. Replacement: If the battery fails to hold a charge after multiple attempts, consider replacing it. Conclusion Repairing and charging Amaron batteries can extend their life if done correctly. Always prioritize safety and follow proper procedures to ensure efficient operation. If you\\'re uncertain about any step, consult a professional or refer to the manufacturer\\'s guidelines.

Send Message
product image
ALL TYPES OF UPS REPAIR

UPS (Uninterruptible Power Supply) repair typically involves diagnosing and fixing issues related to power failures, battery problems, or malfunctioning components. Here are some common repair tasks: Battery Replacement: Batteries in UPS units degrade over time and may need replacing. This is one of the most common repairs. Power Supply Issues: Problems with the internal power supply circuit or malfunctioning capacitors can cause a UPS to fail to charge or provide backup power. Overheating Issues: Dust buildup or fan failure can cause the unit to overheat, requiring cleaning or fan replacement. Inverter and Charger Problems: If the UPS isn't converting DC to AC power properly, it could be an inverter problem. Similarly, charger failures could stop the battery from charging. Internal Component Replacement: This may involve replacing transformers, fuses, or circuit boards that have failed.

Send Message
product image
Vertiv 60 kVA to 200 kVA Ups

The Liebert SX series from Vertiv offers UPS systems ranging from 60 kVA to 200 kVA, utilizing full IGBT double conversion technology. This design enhances efficiency, reduces installation and operational costs, and provides reliable power backup solutions for critical applications. Key Features of Liebert SX 60kVA to 200kVA Modular Design: The Liebert SX series features a modular architecture that allows for easy scalability and maintenance. Front Access Design: This design minimizes repair time and optimizes installation and serviceability, making it user-friendly. Environmental Standards: The Liebert SX series is designed to meet high environmental standards, promoting energy efficiency and sustainability. ID Card for Each UPS: Each unit comes with an ID card that includes all working parameters, which helps in reducing downtime during maintenance. Applications Power Backup: Ideal for critical applications requiring uninterrupted power supply. Data Centers: Suitable for use in data centers where reliability and efficiency are paramount. Industrial Use: Can be utilized in various industrial settings to ensure consistent power availability. Contact Information for Further Inquiries Company: Universal Power System Location: Plot No.-70, Udyog Vihar-VI, Sector-37 Gurugram, Haryana, India -122001 Mobile - 8744823336 Email: info@universalpower.co.in

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
Vertiv Online Ups

Vertiv offers a range of online UPS (Uninterruptible Power Supply) systems designed to provide reliable power protection for critical applications, including data centers, telecommunications, and industrial environments. Here’s a detailed overview of Vertiv's online UPS solutions, including key features, specifications, benefits, and maintenance practices. Vertiv Online UPS Overview Purpose: Online UPS systems are designed to ensure continuous and clean power supply by converting incoming AC power to DC and then back to AC. This process provides maximum protection against power disturbances such as surges, sags, and outages. Key Features Continuous Power Supply: Provides uninterrupted power during outages, ensuring that sensitive equipment remains operational. Double-Conversion Technology: Converts incoming AC to DC and back to AC, delivering stable and high-quality power output. High Efficiency: Many models boast efficiencies of 95% or higher, particularly in eco-mode, reducing energy costs. Scalability: Options for parallel operation allow for easy scaling of capacity by adding additional units. Advanced Battery Management: Features for monitoring battery health, optimizing performance, and extending battery life, including temperature and state of charge monitoring. User-Friendly Interface: LCD or LED displays provide real-time data on power status, battery health, and load levels. Network Management Capabilities: Integration with remote monitoring systems through SNMP, allowing for proactive management and alerts. Vibration and Shock Resistance: Designed to withstand harsh operating conditions, making them suitable for industrial environments. Flexible Input/Output Options: Supports various voltages and phases, accommodating different application requirements. Specifications (Typical) Input Voltage: 380/400/415 V (three-phase), with some models supporting single-phase. Output Voltage: 380/400/415 V (three-phase). Output Frequency: 50/60 Hz (auto-sensing). Capacity Range: Varies widely, from small systems (1 kVA) to large systems (up to 500 kVA or more). Efficiency: Typically 95% to 98%, depending on model and operating conditions. Form Factor: Available in tower or rack-mounted configurations. Benefits Reliability: Provides a stable power supply, protecting sensitive equipment from power disturbances. Improved Power Quality: Filters out electrical noise and provides clean power, which is crucial for IT and telecommunications equipment. Cost Savings: High efficiency reduces operational costs, and predictive maintenance can prevent costly downtime. Robust Performance: Designed for heavy loads and capable of maintaining performance under varying conditions. Remote Monitoring: Enables proactive management and quick response to potential issues, enhancing system reliability. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Includes cleaning, tightening connections, and replacing worn-out components as necessary. Battery Management: Monitor battery health, conduct load tests, and replace batteries according to manufacturer guidelines. Documentation: Maintain records of inspections, tests, and repairs to track system performance over time. Professional Support: Engage professional services for emergency repairs, technical support, and routine maintenance. Conclusion Vertiv's online UPS systems provide critical power protection for a variety of applications. With their advanced features, high efficiency, and robust design, they are ideal for ensuring reliable power in environments where uptime is essential. Proper maintenance and proactive management are key to maximizing performance and longevity. If you need more specific information about particular models, configurations, or any other aspect, feel free to ask!

Send Message
product image
Vertiv 500 kva Ups

The Vertiv 500 kVA UPS (Uninterruptible Power Supply) is a high-capacity power protection solution designed for industrial applications, data centers, and critical infrastructure. Here’s a detailed overview of its features, specifications, benefits, and maintenance practices. Vertiv 500 kVA UPS Overview Key Features High Power Capacity: Provides 500 kVA of power, suitable for large-scale applications requiring substantial backup power. Topologies: Online Double-Conversion: This design ensures continuous, clean, and stable power by converting incoming AC to DC and then back to AC, offering maximum protection against power disturbances. High Efficiency: Typically achieves efficiencies of 95% or higher, reducing energy consumption and operational costs. Scalability: Supports parallel operation with multiple units for increased redundancy and power capacity as your needs grow. Advanced Battery Management: Features for optimizing battery performance, including temperature monitoring, state of charge, and predictive diagnostics. User-Friendly Interface: LCD or LED displays provide real-time monitoring of power status, battery health, and load levels. Network Management Capabilities: Integration with network management systems for remote monitoring and control, often through SNMP or web interfaces. Vibration and Shock Resistance: Designed to withstand industrial environments, making it reliable for mission-critical applications. Multiple Input/Output Options: Flexible configurations to match various voltage and phase requirements. Specifications (Typical) Input Voltage: 380/400/415 V (Three-phase) Output Voltage: 380/400/415 V (Three-phase) Output Frequency: 50/60 Hz (auto-sensing) Efficiency: Up to 98% in eco mode. Dimensions: Varies by model; typically designed for rack or floor mounting. Weight: Can exceed 1000 kg, depending on configuration and battery type. Battery Types: Can support various battery technologies, including lead-acid and lithium-ion. Benefits Reliability: Ensures uninterrupted power supply and protects critical loads from power disturbances. Cost Savings: High efficiency leads to lower energy costs, while predictive maintenance helps avoid expensive downtimes. Enhanced Performance: Maintains stable output voltage and frequency, protecting sensitive equipment. Proactive Monitoring: Remote monitoring capabilities allow for early detection of potential issues, improving uptime and reliability. Robust Design: Built to withstand harsh industrial conditions, ensuring longevity and performance. Maintenance and Support Regular Inspections: Schedule periodic checks to assess the condition of the UPS and batteries. Preventive Maintenance: Cleaning, tightening connections, and replacing worn-out parts as needed. Battery Management: Monitor battery health, perform load tests, and replace batteries according to manufacturer guidelines. Documentation: Keep detailed records of maintenance, inspections, and performance metrics. Emergency Support: Engage professional services for emergency repairs and technical support when needed. Conclusion The Vertiv 500 kVA UPS is a robust solution designed for high-demand environments, ensuring reliable power protection for critical applications. With its advanced features and capabilities, it is ideal for data centers, industrial applications, and other mission-critical settings. Proper maintenance and proactive management can further enhance its performance and longevity. If you have specific questions or need additional details, feel free to ask!

Send Message

Still searching for
repair work?