Amaron Quanta 12v 42Ah Battery

The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial. Key Features of Amaron Quanta 42Ah Battery: Capacity: 42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load. Technology: Maintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free. High Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter. Deep Cycle Battery: This is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently. Durability: Long Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored. High-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions. Design: Compact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern. Vibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings. Safety Features: Flame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction. Leak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety. Application Areas: UPS Systems: Provides backup power to computers, servers, and networking equipment. Inverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages. Solar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night. Warranty: The Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details. General Specifications: Voltage: 12V (standard for most UPS and inverter batteries). Capacity: 42Ah. Type: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat). Charging Voltage: Typically around 14.4 to 15.0V for 12V batteries. Nominal Voltage: 12V. Dimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model). Weight: Approximately 12-14 kg. Maintenance Tips for the Amaron Quanta 42Ah Battery: Regular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan. Storage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically. Clean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed. Avoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it. Check for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear. Battery Testing: To check the health of the Amaron Quanta 42Ah battery, you can follow these steps: Voltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V. Load Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation. Capacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold. Conclusion: The Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
AMARON QUANTA 12V 46Ah BATTERY

The AMARON 12V 46Ah battery is a reliable sealed lead-acid battery designed for various applications, including automotive and renewable energy systems. It typically features a nominal voltage of 12V, a capacity of 46Ah, and is known for its durability, low maintenance, and ability to perform well in diverse environmental conditions. Product Overview Type: Sealed Lead Acid (SLA) Battery Nominal Voltage: 12V Capacity: 46Ah Weight: Approximately 12-13 kg (varies by model) Dimensions: Typically around 9.1 x 5.4 x 8.5 inches (L x W x H) Key Features Durability: Designed to withstand harsh conditions and vibrations. Long service life with proper maintenance. Maintenance: Low maintenance requirements; sealed design prevents electrolyte loss. Requires periodic checks for optimal performance. Performance: Excellent deep cycle capabilities, suitable for applications requiring sustained power. Good discharge characteristics, providing reliable power output. Applications Automotive: Ideal for use in cars, trucks, and other vehicles. Suitable for starting, lighting, and ignition (SLI) applications. Renewable Energy: Can be used in solar energy systems for energy storage. Effective in off-grid applications and backup power systems. Warranty and Standards Warranty: Typically comes with a warranty period of 12-18 months, depending on the retailer. Certifications: Complies with international safety and performance standards. Charging and Maintenance Charging Voltage: Recommended charging voltage is around 14.4V to 14.8V. Charging Method: Can be charged using standard lead-acid battery chargers. Avoid overcharging to extend battery life. Environmental Considerations Operating Temperature: Performs well in a wide range of temperatures, typically from -20°C to +50°C. Ensure proper ventilation during charging to prevent gas buildup. This battery is a versatile choice for users looking for a dependable power source across various applications.

Send Message
product image
Battery

The Amaron Quanta SMF Battery 12V 84Ah, also referred to as the 12AL084, is a sealed maintenance-free (SMF) valve-regulated lead-acid (VRLA) battery designed for high performance and reliability. It is suitable for various applications, particularly in uninterruptible power supply (UPS) systems and inverters. Below are the detailed specifications and features of this battery: Product Overview Type: Lead Acid Battery Model: Amaron Quanta 12V/84Ah (12AL084) Voltage: 12 Volts Capacity: 84 Amp-hours (Ah) Weight: Approximately 26 kg Dimensions: Typically around 33 cm x 17.5 cm x 21.5 cm (exact dimensions may vary slightly by manufacturer) Key Features Sealed Maintenance-Free (SMF): The battery is designed to be maintenance-free, eliminating the need for regular checks and maintenance. Valve-Regulated: The VRLA technology prevents spillage and allows for safe operation in various positions. Long Life: Engineered for durability and longevity, making it suitable for backup power applications. High Performance: Provides reliable power during outages, making it ideal for UPS systems and inverters. Quick Recharge: Capable of fast charging, reducing downtime. Low Self-Discharge Rate: Retains charge for longer periods when not in use. Robust Construction: Designed to withstand harsh conditions and provide consistent performance. Applications Uninterruptible Power Supply (UPS): Suitable for both home and commercial UPS systems. Inverters: Works well with various inverter systems for backup power. Data Centers: Ideal for critical applications requiring uninterrupted power. Telecommunication Systems: Used in telecom applications needing reliable power. Industrial Equipment: Supports various industrial applications needing stable power. Security Systems: Ideal for fire alarm systems and other security devices. Warranty & Support Warranty: Typically comes with a warranty period of 24 months. Customer Support: Available through authorized service centers and online platforms. Shipping & Delivery Shipping: Usually calculated at checkout; check with the vendor for shipping options. Delivery Time: Generally within 3-10 working days, depending on location. Same Day Delivery: Available in select areas. Additional Information The Amaron Quanta 12V 84Ah battery is known for its reliability and efficiency, making it a preferred choice for consumers looking for a robust power backup solution. It is designed to provide consistent performance over its lifespan, making it suitable for various demanding applications.

Send Message
product image
Battery

The Amaron Quanta 12V 42Ah battery, also known as the 12AL042, is a sealed maintenance-free (SMF) valve-regulated lead-acid (VRLA) battery designed for reliable performance in various applications, particularly in UPS systems and other power backup solutions. Here are the Product Details: Product Overview Type: Lead Acid Battery Model: Amaron Quanta 12V/42Ah (12AL042) Vendor: Amaron Quanta Key Features Reliable Functionality: Designed for efficient backup and uninterrupted power supply. Sealed Maintenance-Free: No need for regular maintenance, ensuring hassle-free operation. Fast Charging Capability: Suitable for quick recharging. Eco-Friendly: Low carbon footprint due to advanced AGM technology. Product Specifications Battery Capacity: 42 Ah Battery Type: SMF-VRLA (Sealed Maintenance Free - Valve Regulated Lead Acid) Battery Voltage: 12 V Weight: 14 kg Dimensions: 19.9 x 16.7 x 17.5 cm Warranty & Support Warranty: 12 months (some vendors may offer up to 24 months). In Box Accessories: Warranty card included. Applications Suitable for use in: Online UPS systems Telecommunication equipment Fire alarm and security systems Office automation equipment Laboratory equipment Shipping & Delivery Shipping: Usually calculated at checkout. Delivery Time: Generally within 3-10 working days, depending on location. Same Day Delivery: Available in select areas. Additional Information The Amaron Quanta 12V 42Ah battery is engineered for high performance and reliability, making it suitable for various applications that require a stable power supply.

Send Message
product image
battery

The Amaron Quanta 12V 9Ah battery is a type of lead-acid battery commonly used in various applications such as uninterruptible power supplies (UPS), electric vehicles, and other equipment requiring reliable power storage. Here are some key details about the Amaron Quanta 12V 9Ah battery: Specifications: Voltage: 12 volts Capacity: 9 ampere-hours (Ah) Type: Lead-acid battery (typically VRLA - Valve Regulated Lead Acid) Dimensions: Varies by manufacturer, but generally around 151mm x 65mm x 94mm (L x W x H) Weight: Approximately 3.5 to 4 kg, depending on the specific model and manufacturer. Terminal Type: Usually comes with F1 or F2 terminals. Operating Temperature Range: Typically between -15°C to +50°C. Cycle Life: Generally rated for about 300-500 cycles depending on depth of discharge and usage conditions. Features: Maintenance-Free: Designed to be maintenance-free, meaning no need for regular water topping. Leak-Proof Design: The VRLA design prevents leakage, making it safer for various applications. High Discharge Rate: Capable of delivering high currents for short periods, which is beneficial for applications requiring burst power. Deep Cycle Capability: Suitable for deep cycle applications, allowing for a deeper discharge without damaging the battery. Durability: Built to withstand harsh conditions and high temperatures, making it suitable for outdoor use. Applications: Uninterruptible Power Supplies (UPS): Provides backup power during outages. Electric Vehicles (EVs): Used in scooters, bikes, and other electric vehicles. Solar Energy Storage: Can be used in solar energy systems for storing power. Emergency Lighting: Powers emergency lighting systems. Telecommunications: Used in communication equipment for backup power. Maintenance Tips: Regular Inspection: Check for any signs of corrosion on terminals and ensure connections are tight. Proper Charging: Use a compatible charger and avoid overcharging to prolong battery life. Storage: Store in a cool, dry place and maintain a charge if not in use for extended periods. Safety Precautions: Avoid Short Circuits: Ensure terminals do not come into contact with conductive materials. Handle with Care: Batteries can be heavy; handle them carefully to avoid injury. Dispose Properly: Follow local regulations for battery disposal or recycling. For the most accurate and specific details, always refer to the manufacturer\'s datasheet or user manual, as specifications may vary slightly between different production batches or models.

Send Message
product image
Amaron Quanta 12V 46Ah battery In Garhi Harsaru Gurgaon

The Amaron Quanta 12V 46Ah battery is designed primarily for use in a variety of applications, including inverters and backup power systems. Here are the key details: Specifications: Voltage: 12V Capacity: 46Ah (Ampere-hours) Type: Lead-acid battery, generally maintenance-free Technology: Often uses a combination of advanced lead-calcium technology to enhance performance and lifespan. Features: Longer Life: Designed for deep cycle applications, with a longer life expectancy compared to traditional batteries. Durability: Built to withstand deep discharges and heavy loads. Low Maintenance: Sealed design reduces the need for regular maintenance. Vibration Resistant: Suitable for a range of environmental conditions. Applications: Inverter Systems: Commonly used in home inverter systems for backup power. Solar Applications: Compatible with solar power setups for energy storage. Uninterruptible Power Supplies (UPS): Can be used in UPS systems for critical equipment. Performance: Cycle Life: Typically offers a good cycle life with proper charging and discharging practices. Self-Discharge Rate: Relatively low self-discharge rate, allowing for longer storage periods without significant loss of charge. Installation and Maintenance: Installation: Generally straightforward, but should be done according to manufacturer guidelines. Maintenance: Minimal; periodic checks on connections and cleanliness are recommended. Safety: Ventilation: Ensure proper ventilation during charging to avoid gas accumulation. Protection Features: Many models come with built-in protection against overcharging and short circuits. For precise specifications, including dimensions and weight, it’s best to consult the manufacturer's datasheet or product manual.

Send Message
product image
Apc Ups Repairing In Jawahar Colony Faridabad

Repairing an APC UPS (Uninterruptible Power Supply) involves troubleshooting and addressing common issues that can arise over time. Here’s a comprehensive guide to help you diagnose and repair your APC UPS: Safety Precautions Disconnect Power: Always unplug the UPS before performing any repairs or inspections. Use PPE: Wear safety goggles and gloves to protect against electric shock. Work in a Ventilated Area: Ensure good airflow to prevent overheating. Common Issues and Solutions 1. UPS Won\\'t Turn On Check Power Source: Ensure the UPS is plugged in and the outlet is functional. Test the power cord for damage. Battery Issues: Inspect the battery for swelling, leaks, or corrosion. Use a multimeter to check battery voltage; if it\\'s significantly low, it may need replacement. 2. Battery Replacement Identify Battery Type: Refer to the user manual for the specific battery model. Remove the Old Battery: Open the UPS case (usually requires a screwdriver). Disconnect the old battery, noting the connections. Install the New Battery: Connect the new battery securely. Close the UPS case and ensure all screws are tightened. 3. Overheating Check Ventilation: Ensure that the UPS is in a well-ventilated area. Clear any obstructions around vents. Inspect Fans: Check if the internal fans are operational. Clean any dust accumulation. 4. Frequent Alarms or Beeping Load Issues: Ensure that the connected load does not exceed the UPS capacity. Disconnect non-essential devices and see if the alarm stops. Battery Health: Run a self-test (if your model supports it) to check battery status. 5. Self-Test Failure Check Battery Voltage: Use a multimeter to check the voltage of the battery. Replace if below the recommended level. Internal Issues: If the self-test consistently fails, the internal circuitry might need inspection by a professional. Tools and Equipment Needed Multimeter (for voltage checks) Screwdriver set Replacement batteries (as needed) Cleaning cloth or compressed air (for dust removal) Safety equipment (gloves, goggles) General Repair Steps Visual Inspection: Check for any visible signs of damage, such as burnt components or damaged connectors. Inspect for loose wires and connections. Testing Components: Batteries: Measure the voltage and ensure it\\'s within specifications. Fuses: Check fuses for continuity. Replace blown fuses as needed. Fans and Circuits: Ensure fans are operational and listen for unusual noises. Reassembly: After repairs, carefully reassemble the UPS. Ensure all screws and connections are secure before powering on. Testing the UPS: Once reassembled, plug in the UPS and perform a test by connecting a load. Monitor the UPS for any abnormal behavior. Conclusion Repairing an APC UPS can often be straightforward, particularly when it comes to replacing batteries or troubleshooting common issues. However, if the problem persists or if you are unsure about the repair process, it’s advisable to contact a professional technician or the manufacturer for support. Always refer to the specific user manual for detailed instructions related to your UPS model.

Send Message
product image
Amaron Batteries Repairing And Charging In sohna sector 36 Gurgaon

Repairing and charging Amaron batteries (or any lead-acid battery) requires caution and adherence to safety procedures. Here’s a comprehensive guide on how to repair and charge Amaron batteries: Safety Precautions Personal Protective Equipment (PPE): Always wear safety goggles and gloves. Ventilation: Work in a well-ventilated area to avoid inhaling harmful gases. Avoid Short Circuits: Be careful with tools and connections to prevent sparks or short circuits. Tools and Equipment Needed Multimeter (for checking voltage and condition) Battery charger compatible with lead-acid batteries Battery terminal cleaner or wire brush Distilled water (if applicable, for batteries that can be serviced) Insulation tape Safety equipment (gloves, goggles) Steps to Repair and Charge Amaron Batteries 1. Inspect the Battery Check for physical damage, such as cracks or leaks. Inspect terminals for corrosion. Clean terminals with a wire brush if necessary. 2. Test the Battery Use a multimeter to check the voltage. A fully charged 12V battery should read around 12.6 to 12.8 volts. If the voltage is significantly lower (e.g., below 12 volts), the battery may need charging or could be damaged. 3. Charging the Battery Select the Right Charger: Use a smart charger or a lead-acid battery charger that matches the battery’s specifications. Connect the Charger: Connect the positive (+) terminal of the charger to the positive terminal of the battery. Connect the negative (-) terminal of the charger to the negative terminal of the battery. Set the Charger: Choose the appropriate charging mode (usually a slow charge is best for lead-acid batteries). Monitor Charging: Charging time will vary; typically, it can take several hours to overnight. Monitor the charging process. 4. Check Battery Condition After Charging Once fully charged, use the multimeter to measure the voltage again. Perform a load test (if available) to ensure the battery can hold a charge under load. 5. Repairing Cells (if applicable) For Serviceable Batteries: If the battery has removable caps: Check the electrolyte level; add distilled water if needed. Ensure the specific gravity of the electrolyte is within the acceptable range (use a hydrometer). Re-seal the Caps: Make sure all caps are securely in place after checking. 6. Final Inspection and Reinstallation Ensure all connections are clean and secure. Reinstall the battery in the vehicle, connecting the positive terminal first, followed by the negative terminal. Use insulation tape to secure any exposed connections. Additional Tips Avoid Overcharging: Overcharging can damage the battery and reduce its lifespan. Always use a charger with an automatic shut-off feature. Regular Maintenance: Periodically check battery health, clean terminals, and keep the battery charged to prolong its life. Replacement: If the battery fails to hold a charge after multiple attempts, consider replacing it. Conclusion Repairing and charging Amaron batteries can extend their life if done correctly. Always prioritize safety and follow proper procedures to ensure efficient operation. If you\\'re uncertain about any step, consult a professional or refer to the manufacturer\\'s guidelines.