Vertiv Three Phase Ups In Faridabad

Vertiv three phase UPS systems are designed to provide reliable and efficient power protection for critical applications. They are available in a range of capacities and configurations to suit different needs. Key Features: Three phase power protection High efficiency and reliability Scalable and flexible design Advanced monitoring and control capabilities Types of Vertiv Three Phase UPS: Liebert ITA2: A three phase UPS system designed for small to medium-sized data centers and other critical applications. Liebert EXS: A three phase UPS system designed for medium to large-sized data centers and other critical applications. Liebert EXM: A three phase UPS system designed for large data centers and other critical applications. Liebert EXL S1: A three phase UPS system designed for large data centers and other critical applications. Applications: Data centers Critical infrastructure Industrial applications Healthcare applications Technical Specifications: Capacity: 10-500 kVA Voltage: 208-480V Frequency: 50-60Hz Efficiency: Up to 96% Power factor: 0.9-1.0 Warranty: 2-5 year warranty depending on the model

Send Message
product image
3kva ups

The Vertiv Liebert GXT MT+ 3KVA UPS is an online double-conversion uninterruptible power supply designed for reliable power protection. It features a compact tower design, a wide input voltage range, and an intuitive LCD display for easy monitoring. The UPS offers high efficiency, with double conversion efficiency up to 90%, ensuring optimal performance in various conditions. Here are the key details: Key Features Double Conversion Technology: Provides continuous power conditioning and protection against power disturbances. Input Voltage Range: Wide input voltage range allows for operation in diverse environments. LCD Display: New graphical LCD display provides real-time UPS data, alarms, and aids in fault diagnostics. Efficiency: High efficiency of up to 90% at full load, contributing to lower energy costs. Compact Design: Space-saving tower design suitable for various installations. Extended Runtime Options: Available models with extended runtime capabilities for critical applications. Automatic Frequency Detection: Automatically detects and adjusts to the input frequency. Input Circuit Breaker: Protects the UPS and connected equipment from overloads. Active Power Factor Correction: Enhances the input power factor, reducing energy consumption. Specifications Power Rating: 3KVA / 3000W Output Voltage: 230V or 208V options available Form Factor: Tower Weight: Varies by model, typically around 20-30 kg Dimensions: Compact dimensions for easy placement in IT environments Applications Ideal for IT infrastructure, data centers, and critical equipment requiring uninterrupted power supply. Suitable for environments with stringent power quality requirements. Conclusion The Vertiv Liebert GXT MT+ 3KVA UPS is a robust solution for ensuring the health and availability of critical systems, providing reliable power protection and efficient operation in various settings.

Send Message
product image
Vertiv 6 Kva Ups

The Vertiv Liebert GXT5-6000RT120 is a popular 6 kVA online uninterruptible power supply (UPS) designed for critical applications in data centers and IT environments. Below are the key specifications and features of the Vertiv 6 kVA UPS: Key Features Form Factor: Rack-mountable (typically 3U) or tower configuration, depending on the model. Power Rating: Capacity: 6 kVA (6000 VA) / 5.4 kW output. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 120 VAC (or 220/230/240 VAC depending on configuration). Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with a hardwired connection or NEMA L6-30P plug. Output Specifications: Output Voltage: Configurable 120/208/230/240 VAC. Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple NEMA outlets or terminal block connections for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries providing backup power during outages. Battery Runtime: Varies based on load; typically offers several minutes to hours of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often exceeding 95% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB, RS-232, and optional SNMP card for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 5.2 inches (3U) in height, with width and depth depending on the specific model. Weight: Typically around 100 lbs (45 kg), depending on the battery configuration. Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT5-6000RT120 is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
Liebert Series 610 On-line UPS In Patparganj Delhi

The Liebert Series 610 On-line UPS is a true double-conversion online UPS designed for large facilities, offering a high level of reliability and flexibility. Here are its key specifications and features: Specifications: Power Rating: 225k VA to 600kVA Input Voltage: 380V to 480V AC Output Voltage: 380V to 480V AC Frequency: 50/60 Hz Efficiency: Up to 94% Battery Type: Valve-Regulated Lead-Acid (VRLA) Battery Capacity: Up to 40 minutes at full load Dimensions: Varies by model Weight: Varies by model Features: High Efficiency: Up to 94% efficiency, reducing heat output and energy costs Flexibility: Modular design allows for easy expansion and customization Reliability: True double-conversion online UPS design provides high reliability and fault tolerance Scalability: Supports large facilities with high power requirements Low Heat Output: Reduces the need for complex cooling arrangements Higher DC Bus Utilization: Provides higher AC/AC and DC/AC efficiency and allows for a relatively smaller battery Applications: Enterprise Data Centers: Provides reliable power protection for large data centers Colocation/Hosting: Supports high-density colocation and hosting facilities Services: Engineering: Customized engineering services for UPS system design and implementation Installation: Professional installation services for UPS systems Preventative Maintenance: Regular maintenance services to ensure UPS system reliability Monitoring: Real-time monitoring services for UPS system performance Recycling: Environmentally responsible recycling services for UPS batteries and equipment Certifications: ISO 9001: Quality management system certification ISO 14001: Environmental management system certification ISO 45001: Occupational health and safety management system certification

Send Message
product image
UPS

overview of the Vertiv 1000 kVA UPS, focusing on its features, specifications, and applications. General Overview Type: Online UPS (Double-Conversion) Capacity: 1000 kVA (1 MVA) Form Factor: Typically floor-mounted, designed for large facilities. Electrical Specifications Input Voltage: Usually 380V to 480V AC, three-phase Output Voltage: Configurable output, typically 380V to 480V AC Frequency: 50/60 Hz (auto-sensing) Output Power Factor: Typically around 0.9 to 1.0 Performance Efficiency: High efficiency, often exceeding 95%, with options for eco-mode to enhance energy savings. Transfer Time: Zero milliseconds due to the online architecture, ensuring uninterrupted power supply. Battery and Runtime Battery Type: Commonly uses sealed lead-acid (SLA) or lithium-ion batteries. Battery Backup Time: Varies based on load; external battery cabinets can extend runtime. Recharge Time: Typically 4-8 hours to recharge from complete discharge. Features User Interface: LCD display with real-time monitoring of operational status, battery health, load levels, and alarms. Communication Ports: SNMP, USB, and RS-232 for monitoring and remote management. Surge Protection: Built-in surge protection to safeguard connected equipment. Overload Protection: Automatic shutdown in case of overload conditions. Physical Specifications Dimensions: Size varies by model; requires substantial floor space and proper ventilation. Weight: Generally heavy; ensure appropriate installation support. Installation and Management Mounting Options: Designed for floor mounting; requires sufficient space and infrastructure. Management Software: Advanced software options for monitoring and managing UPS status remotely. Applications Ideal for: Data centers Large IT infrastructures Industrial applications Telecommunications Healthcare facilities Additional Features Modularity: Some models may offer modular designs for scalability and redundancy. Hot-Swap Capability: Allows battery replacement and maintenance without downtime. Parallel Operation: Supports parallel configurations for redundancy and capacity scaling. Warranty and Support Warranty: Generally includes a limited warranty covering parts and labor, with options for extended service agreements. Support: Vertiv offers various support services, including installation, maintenance, and monitoring solutions. Conclusion The Vertiv 1000 kVA UPS is designed for mission-critical applications requiring high reliability and performance. It is well-suited for environments where power continuity is essential.

Send Message
product image
VERTIV 175 TO 200 KVA ONLINE UPS IN SECTOR 82 NOIDA

overview of the Vertiv UPS models in the 175 kVA to 200 kVA range, focusing on features, specifications, and applications. General Overview Type: Online UPS (Double-Conversion) Capacity: 175 kVA to 200 kVA Form Factor: Typically available in a floor-standing configuration Electrical Specifications Input Voltage: Typically 380V to 480V AC three-phase Output Voltage: 380V to 480V AC (configurable based on application) Frequency: 50/60 Hz (auto-sensing) Output Power Factor: Usually around 0.9 to 1.0 Performance Efficiency: High efficiency, often exceeding 95% in normal operating mode, with some models offering an eco-mode for even greater energy savings. Transfer Time: Zero milliseconds due to the online architecture. Battery and Runtime Battery Type: Typically uses sealed lead-acid (SLA) or lithium-ion batteries. Battery Backup Time: Varies based on load; options for extended runtime through external battery cabinets. Recharge Time: Generally 4-8 hours to recharge from complete discharge, depending on configuration. Features LCD Display: Advanced display panel providing real-time information on operational status, battery health, load percentage, and alarms. Communication Ports: Options typically include USB, RS-232, and SNMP for monitoring and management. Surge Protection: Built-in surge protection to safeguard equipment. Overload Protection: Automatic shutdown in case of overload situations. Physical Specifications Dimensions: Varies by model; typically requires dedicated floor space. Weight: Generally heavy; ensure proper installation and support infrastructure. Installation and Management Mounting Options: Floor-mounted; requires adequate space and ventilation. Management Software: Advanced management and monitoring software available, allowing for remote control and status checks. Applications Ideal for: Data centers Critical IT infrastructure Telecommunications Industrial applications Healthcare facilities Additional Features Modularity: Some models offer modular design for scalability. Hot-Swap Capability: Allows for battery maintenance without downtime. Redundancy Options: Parallel operation capability for enhanced reliability. Warranty and Support Warranty: Typically includes a limited period covering parts and labor, with options for extended service agreements. Support: Vertiv provides various support services, including installation, maintenance, and remote monitoring. Conclusion The Vertiv UPS in the 175 kVA to 200 kVA range is designed for robust applications that require high reliability and performance. These systems are ideal for environments where uptime is critical.

Send Message
product image
Vertiv 30kVA Online Ups

The Vertiv 30kVA UPS is a high-performance uninterruptible power supply system designed for data centers, server farms, telecom, medical, and industrial applications. It offers efficient and economical operation with a flexible power system, scalable and redundant features , and a compact footprint. Key Features: High Power Density: The Vertiv 30kVA UPS provides a high power density of up to 30kVA in a compact footprint, making it ideal for data centers and other applications where space is limited. High Efficiency: The UPS operates at a high efficiency of up to 95%, reducing energy losses and operating costs. Scalable and Redundant: The system is designed to be scalable and redundant, allowing users to add or remove power modules as needed, and providing N+1 redundancy for high availability. Flexible Power System: The Vertiv 30kVA UPS offers a flexible power system that can be configured to meet specific application requirements. Compact Footprint: The system has a compact footprint, making it ideal for applications where space is limited. Technical Specifications: Input Voltage: 208-240V AC, 3-phase, 4-wire Output Voltage: 208-240V AC, 3-phase, 4-wire Frequency: 50/60 Hz Power Factor: 0.9 leading to 0.9 lagging Efficiency: Up to 95% Dimensions: 800 x 600 x 1200 mm (H x W x D) Weight: Approximately 600 kg Benefits: High Availability: The Vertiv 30kVA UPS provides high availability and reliability, ensuring that critical applications remain operational during power outages. Energy Efficiency: The system operates at a high efficiency, reducing energy losses and operating costs. Flexibility: The UPS offers a flexible power system that can be configured to meet specific application requirements. Scalability: The system is designed to be scalable, allowing users to add or remove power modules as needed. Compact Design: The system has a compact footprint, making it ideal for applications where space is limited.

Send Message
product image
Emerson 40kVA Online UPS

The Emerson 40kVA Online UPS is a high-capacity uninterruptible power supply designed for critical applications where power reliability is essential. Here are the detailed specifications and features typically associated with this UPS model: Specifications Capacity: 40 kVA (kilovolt-amps) Input Voltage: Typically operates within a range of 380V to 480V AC. Output Voltage: Provides stable output, usually around 400V or 415V AC. Output Waveform: Pure sine wave output to ensure compatibility with sensitive electronic equipment. Input Frequency: Generally supports 50/60 Hz auto-sensing. Features Online Double-Conversion Technology: Ensures continuous power supply by converting incoming AC to DC and then back to AC, effectively isolating the load from power disturbances. LCD Display: Provides real-time information on operational status, including input/output voltage, battery status, and load percentage. Battery Type: Usually uses sealed lead-acid or lithium-ion batteries, depending on the specific model configuration. Charging Time: Full charge time can range from 4 to 8 hours, depending on battery type and condition. Runtime: Varies based on load; configurations can provide backup for several minutes to hours. Protection Features Overload Protection: Automatically shuts down the UPS to prevent damage if the load exceeds the rated capacity. Short-Circuit Protection: Protects against potential damage due to short circuits. Surge Protection: Guards connected equipment from voltage spikes and transients. Thermal Management: Equipped with fans and temperature sensors to prevent overheating. Connectivity Output Sockets: Multiple outlets for connecting various devices, often including hardwired connections. Communication Ports: USB, RS232, and SNMP options for remote monitoring and management. Parallel Operation: Supports multiple UPS units to work together for enhanced capacity and redundancy. Applications Suitable for: Data centers Telecommunications Industrial applications Medical equipment Critical IT infrastructure Installation & Maintenance Installation: Typically requires professional installation due to its size and complexity. Maintenance: Regular maintenance checks are essential for battery health and overall system performance. Warranty Often includes a manufacturer’s warranty, typically ranging from 1 to 3 years, depending on the model and specific terms.

Send Message
product image
Battery Testing In Sonipat

Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details: Types of Tests: Voltage Test: Measures the battery's output voltage to check if it meets the specified range. Capacity Test: Assesses how much charge the battery can hold and deliver over time. Load Test: Simulates real-world usage to check how the battery performs under load. Internal Resistance Test: Evaluates the battery's internal resistance, indicating its health. Tools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers. Frequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures. Indicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage. Proper battery testing helps in proactive maintenance, ensuring reliability and safety.