Faridabad
+918076792323

'environmental control'

Items tagged with 'environmental control'

product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
Repairing And Maintaining UPS

Repairing And Maintaining UPS (Uninterruptible Power Supply) batteries is crucial for ensuring the reliability and longevity of the power backup system. Here’s a detailed overview of UPS battery maintenance and repair practices. UPS Battery Types Lead-Acid Batteries: Valve-Regulated Lead Acid (VRLA): Maintenance-free and sealed, suitable for most UPS systems. Flooded Lead Acid: Requires periodic maintenance and water topping. Lithium-Ion Batteries: Increasingly used due to longer life and higher efficiency but may require specific handling protocols. Maintenance Practices Regular Inspections: Visual Check: Inspect batteries for physical damage, corrosion, or leaks. Look for swelling or bulging in case of lead-acid batteries. Connections: Ensure all terminals and connections are tight and free of corrosion. Cleaning: Clean battery terminals with a mixture of baking soda and water to remove corrosion. Rinse with clean water and dry thoroughly. Battery Testing: Voltage Checks: Regularly measure the voltage of each battery to identify weak cells. Load Testing: Perform load tests to ensure the battery can deliver the expected capacity under load conditions. Temperature Monitoring: Monitor battery temperature, especially in environments with high heat, as excessive temperatures can affect battery performance and lifespan. Electrolyte Level (for Flooded Batteries): Check and maintain the electrolyte levels in flooded lead-acid batteries. Top up with distilled water as necessary. Battery Health Monitoring: Use battery management systems (BMS) for advanced monitoring of battery health, state of charge, and state of health. Repair Practices Identifying Faults: Common issues include short-circuited cells, sulfation, and capacity loss. Use diagnostic tools to identify problems. Replacing Individual Batteries: If a battery within a pack fails, replace only the faulty battery if it’s compatible. However, it's often recommended to replace all batteries in a series to ensure uniform performance. Equalization Charging (for Flooded Batteries): Periodically perform equalization charging to balance the charge across all cells and prevent sulfation. Reconditioning: Some lead-acid batteries can be reconditioned through a process of controlled charging and discharging to restore capacity. This is not always successful and should be done by professionals. Battery Replacement: When batteries reach the end of their lifespan (typically 3-5 years for lead-acid), replace them with new ones. Ensure that replacements meet the manufacturer's specifications. Best Practices for Maintenance Documentation: Keep records of inspections, tests, and replacements to track battery performance over time. Environmental Conditions: Maintain an optimal environment for batteries—ideally, a cool, dry place free from excessive humidity and temperature fluctuations. Professional Servicing: Consider engaging professionals for complex repairs or maintenance tasks, especially for large or critical UPS systems. Training: Train personnel on proper handling, maintenance, and safety procedures related to UPS batteries. Conclusion Regular maintenance and timely repairs of UPS batteries are essential for ensuring the reliability of power backup systems. By implementing best practices, monitoring battery health, and addressing issues promptly, you can prolong the life of your UPS batteries and enhance overall system performance. If you have specific questions or need further details on any aspect, feel free to ask!

Send Message
product image
UPS

Emerson offers a range of three-phase industrial UPS systems designed to provide reliable power protection for critical applications. Here are some key details typically associated with Emerson's three-phase UPS solutions: Key Features Power Capacity: Models often range from 10 kVA to several hundred kVA, catering to different industrial requirements. Topology: Many models utilize an online double-conversion topology, which ensures continuous power supply and zero transfer time during outages. Efficiency: High-efficiency ratings (up to 96% or more) help reduce energy costs and heat generation. Modular Design: Many systems allow for modular configurations, enabling easy scalability and redundancy. Smart Battery Management: Advanced battery management systems extend battery life and enhance performance. User Interface: LCD screens or touchscreen interfaces for real-time monitoring, diagnostics, and control. Communication Protocols: Various options for remote monitoring and integration, including SNMP, Modbus, and other industry-standard protocols. Input/Output Configuration: Flexible I/O options for different electrical environments, often with customizable settings. Applications Data centers Industrial automation systems Telecommunications Manufacturing facilities Critical power applications in healthcare Considerations Installation: Requires professional installation to ensure compliance with local electrical codes and optimal performance. Maintenance: Regular maintenance checks are necessary for reliability; consider a service contract for ongoing support. Load Assessment: Properly assess total load requirements to select the appropriate UPS capacity. Environmental Conditions: Ensure the UPS is suitable for the operating environment (temperature, humidity, etc.). Popular Models Emerson has various models within its UPS lineup, including: Liebert APM: Modular UPS systems known for scalability and high efficiency. Liebert EXL S1: High-density UPS for critical loads, offering excellent performance and efficiency. Conclusion When considering an Emerson three-phase industrial UPS, it's essential to evaluate specific needs, including power requirements, space constraints, and operational conditions. For the most accurate and detailed information, including specifications and installation requirements, consult Emerson's official documentation or contact a local representative. If you have specific models or features in mind, let me know!

Send Message
product image
Vertiv 6 Kva Ups

The Vertiv Liebert GXT5-6000RT120 is a popular 6 kVA online uninterruptible power supply (UPS) designed for critical applications in data centers and IT environments. Below are the key specifications and features of the Vertiv 6 kVA UPS: Key Features Form Factor: Rack-mountable (typically 3U) or tower configuration, depending on the model. Power Rating: Capacity: 6 kVA (6000 VA) / 5.4 kW output. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 120 VAC (or 220/230/240 VAC depending on configuration). Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with a hardwired connection or NEMA L6-30P plug. Output Specifications: Output Voltage: Configurable 120/208/230/240 VAC. Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple NEMA outlets or terminal block connections for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries providing backup power during outages. Battery Runtime: Varies based on load; typically offers several minutes to hours of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often exceeding 95% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB, RS-232, and optional SNMP card for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 5.2 inches (3U) in height, with width and depth depending on the specific model. Weight: Typically around 100 lbs (45 kg), depending on the battery configuration. Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT5-6000RT120 is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
Vertiv 1 kva Ups

The Vertiv Liebert GXT RT+ 1 kVA is a highly regarded rack-mountable uninterruptible power supply (UPS) designed for critical applications, including data centers and IT environments. Below are the key details and specifications for the Liebert GXT RT+ 1 kVA model: Key Features Form Factor: Rack-mountable design, typically in a 2U form factor, allowing for easy integration into standard server racks. Power Rating: Capacity: 1 kVA (1000 VA) / 800 W output. Topology: On-Line Double-Conversion: Provides continuous power and zero transfer time to battery during power disturbances, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 100-240 VAC, auto-sensing. Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with IEC C14 inlet. Output Specifications: Output Voltage: 220/230/240 VAC (configurable). Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple IEC outlets for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries that provide backup power during outages. Battery Runtime: Varies based on load; typically provides several minutes of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often above 90% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 ports for management and monitoring. SNMP card options may be available for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 3.5 inches (2U) in height, with width and depth depending on the specific model. Weight: Varies based on battery configuration but generally around 20-30 lbs (9-14 kg). Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards, such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and small servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT RT+ 1 kVA UPS is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
UPS

The Vertiv Liebert EXM is a modular uninterruptible power supply (UPS) designed for critical applications requiring high availability and reliability. It is particularly suitable for data centers, telecommunications, and other environments where power continuity is essential. Below are the key details and specifications of the Vertiv Liebert EXM UPS: General Features: Modular Design: The Liebert EXM features a modular architecture, allowing for easy scalability. Users can add or remove power modules as needed to meet changing power requirements. High Efficiency: The UPS is designed for high efficiency, often exceeding 95% in double conversion mode, which helps reduce energy costs and heat generation. Flexible Configuration: Available in various configurations, including single-phase and three-phase outputs, to accommodate different applications and environments. Advanced Monitoring: Equipped with advanced monitoring and management features, including a user-friendly LCD display and network management capabilities, allowing for remote monitoring and control. Redundancy: Supports N+1 redundancy, ensuring that if one module fails, the remaining modules can continue to provide power without interruption. Hot-Swap Capability: Modules can be replaced or serviced without shutting down the UPS, ensuring continuous operation. Smart Battery Management: Features intelligent battery management systems that optimize battery performance and lifespan. Specifications: While specific specifications can vary based on the model and configuration, here are common specifications for the Liebert EXM UPS: Power Ratings: Typically available in configurations ranging from 10 kVA to 40 kVA per module, with the ability to scale up to higher capacities by adding modules. Input Voltage: 380/400/415V three-phase (configurable). Output Voltage: 380/400/415V three-phase (configurable). Frequency: 50/60 Hz (auto-sensing). Efficiency: Up to 95% in double conversion mode and even higher in eco-mode operation. Battery Type: Typically uses valve-regulated lead-acid (VRLA) batteries, with options for lithium-ion batteries in some configurations. Operating Temperature: Generally operates in the range of 0°C to 40°C (32°F to 104°F). Dimensions: Varies based on the configuration and number of modules; typically, a standard 10 kVA module might have dimensions around 600 mm (W) x 800 mm (D) x 2000 mm (H). Weight: Weight varies by configuration but can range from 50 kg to over 200 kg for larger systems. Applications: Data Centers: Ideal for protecting critical IT infrastructure from power disruptions. Telecommunications: Ensures reliable power for telecom equipment and networks. Industrial Applications: Suitable for manufacturing and process control systems requiring uninterrupted power. Healthcare: Provides backup power for critical medical equipment and systems. Warranty and Support: Vertiv typically offers a standard warranty period for its UPS systems, which may vary by region and model. Extended warranty and service plans are often available. Maintenance Tips: Regular Testing: Conduct regular testing of the UPS and batteries to ensure proper operation. Firmware Updates: Keep the UPS firmware updated to benefit from the latest features and improvements. Environmental Monitoring: Ensure the UPS is installed in a suitable environment, with adequate cooling and ventilation. Conclusion: The Vertiv Liebert EXM UPS is a robust and flexible solution for critical power applications, offering high efficiency, modularity, and advanced monitoring capabilities. For specific models, configurations, and detailed specifications, it is advisable to consult the manufacturer\'s documentation or contact a Vertiv representative.

Send Message
product image
12v 150ah

The Amaron Quanta 12V 150Ah battery is a Sealed Maintenance Free (SMF) VRLA (Valve Regulated Lead Acid) battery designed for UPS applications. It has a capacity of 150Ah and operates at 12 volts. The battery comes with a warranty of 24 months. Key Features: PPCP Containers with low permeability ensures that there is no water loss Lead Acid Storage Type @ C20 Rating Proven AGM technology ensures maintenance-free characteristics Reinforced end walls improve impact resistance Thicker grids and higher separator compression prolong life expectancy Inter cell weld between cells provide a high reliable, low resistance current path A unique heavy duty corrosion-resistant alloy for positive grids, to increase cyclic life in tropical environments Radgrid profile provides lower internal resistance and superior high discharge performance Instacharge a patented paste recipe for excellent charge acceptance Low self-discharge rates for extended storage periods Conforms to International standards – JIS8702C Design float life of 10 years Clean and Sleek looks Specifications: Capacity: 150Ah Type: SMF, VRLA (Sealed Maintenance Free, Valve Regulated Lead Acid) Volts: 12V Warranty: 24 months Weight: 46 kgs (approx.) Dimensions: 406168283 in mm (approx.) Applications: Data Centers Online UPS Inverter Systems Banks & Financial Markets Network Operation Centers Semiconductor Manufacturing Power Generation Plants Hospital & Testing Laboratories Portable Testing & Measuring Instruments Vending machines & Weighing Scales Office Automation Equipment Fire Alarm & Security Systems Electronic PABX Systems Telecommunication Systems Process Instrumentation & Control Railway Signalling Power Plants & Substations Benefits: High performance and reliability Low maintenance cost Long lifespan Environmentally friendly Warranty and Support: Warranty period: 24 months Customer support: Available from the manufacturer and authorized dealers

Send Message
product image
12v160ah

The Amaron Quanta 12V 160Ah battery is a Sealed Maintenance Free (SMF) VRLA (Valve Regulated Lead Acid) battery designed for UPS applications. It has a capacity of 160Ah and operates at 12 volts. The battery comes with a warranty of 24 months. Key Features: PPCP Containers with low permeability ensures that there is no water loss Lead Acid Storage Type @ C20 Rating Proven AGM technology ensures maintenance-free characteristics Reinforced end walls improve impact resistance Thicker grids and higher separator compression prolong life expectancy Inter cell weld between cells provide a high reliable, low resistance current path A unique heavy duty corrosion-resistant alloy for positive grids, to increase cyclic life in tropical environments Radgrid profile provides lower internal resistance and superior high discharge performance Instacharge a patented paste recipe for excellent charge acceptance Low self-discharge rates for extended storage periods Conforms to International standards – JIS8702C Design float life of 10 years Clean and Sleek looks Specifications: Capacity: 160Ah Type: SMF, VRLA (Sealed Maintenance Free, Valve Regulated Lead Acid) Volts: 12V Warranty: 24 months Weight: 52 kgs (approx.) Dimensions: 445168283 in mm (approx.) Applications: Data Centers Online UPS Inverter Systems Banks & Financial Markets Network Operation Centers Semiconductor Manufacturing Power Generation Plants Hospital & Testing Laboratories Portable Testing & Measuring Instruments Vending machines & Weighing Scales Office Automation Equipment Fire Alarm & Security Systems Electronic PABX Systems Telecommunication Systems Process Instrumentation & Control Railway Signalling Power Plants & Substations Benefits: High performance and reliability Low maintenance cost Long lifespan Environmentally friendly Warranty and Support: Warranty period: 24 months Customer support: Available from the manufacturer and authorized dealers

Send Message
product image
Vertiv 10kVA Ups In Omaxe City Sonipat

The Vertiv 10kVA UPS is a true online double-conversion UPS designed to provide high-quality power protection for critical applications. Here are its key specifications and features: Specifications: Power Rating: 10kVA / 8kW Input Voltage: 230V AC Output Voltage: 230V AC Input Frequency: 50/60 Hz Output Frequency: 50/60 Hz Efficiency: Up to 94% (depending on load) Battery Type: Valve-Regulated Lead-Acid (VRLA) Battery Capacity: Typically provides backup for 10-15 minutes at full load (depending on battery configuration) Dimensions: Varies by model, typically around 700 x 500 x 1000 mm Weight: Approximately 80-100 kg (depending on configuration) Features: True Online Operation: Provides continuous power supply without any transfer time, ensuring zero downtime. Double-Conversion Technology: Ensures high-quality power output, independent of input voltage and frequency. High Efficiency: Reduces energy costs and heat generation, contributing to a more sustainable operation. Advanced Battery Management: Prolongs battery life and ensures optimal performance through intelligent charging and discharging. LCD Display: Provides real-time monitoring of UPS status, including input/output voltage, load percentage, and battery status. Modular Design: Allows for easy maintenance and upgrades. Multiple Communication Ports: Includes RS-232, USB, and optional SNMP for remote monitoring and management. Hot-Swappable Batteries: Enables battery replacement without interrupting power to the load. Parallel Capability: Allows for scalability and redundancy in high-availability applications. Applications: Data Centers: Ensures reliable power for critical IT infrastructure. Telecommunications: Protects sensitive telecom equipment from power disturbances. Medical Facilities: Supports essential medical equipment requiring uninterrupted power. Industrial Applications: Suitable for manufacturing and process control systems. Financial Institutions: Provides reliable power for critical financial systems. Services: Engineering: Customized solutions for specific power requirements. Installation: Professional installation services to ensure proper setup. Preventive Maintenance: Regular maintenance to ensure optimal performance and reliability. Monitoring: Remote monitoring services to track UPS performance and health. Recycling: Environmentally responsible disposal of old batteries and equipment. Certifications: ISO 9001: Quality management system certification. ISO 14001: Environmental management system certification. ISO 45001: Occupational health and safety management system certification. CE: Conforms to European Union safety and environmental standards. UL: Conforms to Underwriters Laboratories safety standards. Warranty: Standard Warranty: Typically offers a 2-year warranty on the UPS system and batteries. Extended Warranty: Options for additional warranty coverage may be available. Additional Information: The Vertiv 10kVA UPS is designed to provide high-quality power protection for critical applications, ensuring maximum uptime and reliability. Its true online double-conversion technology and advanced battery management features make it an ideal choice for data centers, telecommunications, medical facilities, and other industries requiring high-availability power systems. If you need more specific details or have further questions, feel free to ask!

Send Message

Still searching for