Faridabad
+918076792323

'ideal modular power protection'

Items tagged with 'ideal modular power protection'

product image
Vertiv Powerbank

The Vertiv Liebert Powerbank 600 is a modular and scalable uninterruptible power supply (UPS) solution designed for critical applications, particularly in data centers and telecommunications. It provides reliable power protection and is known for its flexibility and efficiency. Key Specifications Model: Liebert Powerbank 600 Capacity: 600 kVA Input Voltage: Typically supports 380/400/415 V three-phase systems Output Voltage: Configurable based on system requirements Form Factor: Modular design for easy scalability Efficiency: High efficiency, often exceeding 95% in double conversion mode Features Modular Design: Allows for easy expansion and maintenance, enabling users to add or replace modules as needed. High Availability: Designed for redundancy and reliability, ensuring continuous power supply to critical loads. Advanced Monitoring: Equipped with a user-friendly interface and remote monitoring capabilities for real-time performance tracking. Flexible Configuration: Supports various configurations to meet specific power requirements and environmental conditions. Battery Management: Intelligent battery management features to optimize battery life and performance. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Compact Footprint: Designed to maximize power density in limited spaces, making it suitable for various installation environments. Applications Data Centers: Provides robust power protection for critical IT infrastructure. Telecommunications: Ensures uptime for communication systems. Industrial Applications: Safeguards sensitive equipment in manufacturing and processing environments. Performance Metrics Input Frequency: Typically supports 50/60 Hz Output Power Factor: Generally rated at 0.9, allowing for efficient power delivery. Operating Temperature: Designed to operate in a range of 0 to 40 degrees Celsius. Conclusion The Vertiv Liebert Powerbank 600 is a reliable and efficient UPS solution for businesses that require uninterrupted power supply for their critical applications. Its modular design, advanced features, and scalability make it suitable for a wide range of environments, ensuring that essential systems remain operational during power disturbances. For specific model details and configurations, it is advisable to consult the official Vertiv documentation or a local distributor.

Send Message
product image
Eaton 9395P UPS

The Eaton 9395P UPS is a high-performance uninterruptible power supply designed for critical applications. It features a three-phase online design with power ratings ranging from 250 to 1200 kVA, utilizing advanced technology for high efficiency and scalability. Key Specifications Power Ratings: 250-1200 kVA Input Voltage: Typically 480V, with options for 400V or 600V Efficiency: High double conversion efficiency with reduced energy losses Battery Types: Supports VRLA, AGM, and wet cell batteries Overload Capacity: 110% for 10 minutes, 125% for 2 minutes, 150% for 15 seconds Display: 7” or 10” touchscreen for monitoring and control Features Modular Design: Allows for easy scalability and maintenance. Advanced Monitoring: Provides real-time data and alerts for optimal performance. Compact Footprint: Designed to maximize power density in limited spaces. Applications Ideal for data centers, telecommunications, and industrial environments where reliable power is critical. For more detailed specifications, you can refer to the official Eaton documentation. ### Additional Features Energy Saver System (ESS): Achieves up to 99% efficiency, significantly reducing operational costs. Three-Level Converter Design: Reduces stress on components, extending their lifespan and reliability. Heat Reduction: Produces 33% less heat, leading to lower HVAC costs. Increased Power Density: Offers up to 20% more power in the same footprint compared to previous models. Redundancy: Modular design ensures inherent redundancy, preventing dropped loads. Battery Information Battery System: External battery systems are used, with options for lead-acid or lithium batteries. Batteries Included: Typically, batteries are not included and must be purchased separately. Lead Time Availability: Estimated lead time for delivery is 20+ weeks, depending on configuration and order specifics. Target Markets Enterprise Data Centers: Provides robust power protection for critical IT infrastructure. Colocation Facilities: Supports multiple clients with varying power needs. Server Farms and Telecommunications: Ensures uptime for essential services and applications. Healthcare and Financial Systems: Protects sensitive equipment and data from power interruptions. Conclusion The Eaton 9395P UPS is engineered for high efficiency and reliability, making it an excellent choice for organizations that require uninterrupted power supply. Its modular design, advanced features, and scalability cater to a wide range of applications, ensuring that critical systems remain operational during power disturbances. For further details, consult the official Eaton website or authorized distributors.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
Vertiv Three Phase Online Ups

The Vertiv Online UPS systems offer a range of three-phase solutions designed for critical power applications. Here are some key models and their specifications: 1. Liebert EXS Power Rating: Up to 20 kVA Output Configuration: Configurable for three-phase (3/3) or single-phase (3/1) output Flexibility: On-site configuration allows adaptation to changing power needs Efficiency: High efficiency with double conversion technology Applications: Suitable for data centers and critical IT infrastructure 2. Liebert ITA2 Power Rating: Up to 10 kVA Design: Available in rackmount or tower configurations Reliability: Economical and efficient three-phase power for critical loads Features: High power factor and compact design 3. Liebert NX Power Rating: 40-200 kVA Scalability: Allows growth from 40 to 60 to 80 kVA, and from 80 to 100 to 120 kVA Parallel Operation: Can be paralleled for additional capacity or redundancy Efficiency: Designed for high efficiency and reliability 4. Vertiv Trinergy Power Rating: 1500-2500 kW Modular Design: High-capacity modular UPS for large applications Reliability: Maximized reliability with advanced features for critical systems 5. Liebert NXL Power Rating: Up to 800 kW Input Voltage: 480VAC, three-phase, three-wire Load Voltage: 480VAC, three-phase, three-wire in and out or four-wire in Applications: Ideal for large data centers and mission-critical environments General Features Across Models Double Conversion Technology: Ensures continuous power conditioning and protection against power disturbances High Efficiency: Designed to minimize energy costs while maximizing performance Advanced Monitoring: Many models include LCD displays for real-time monitoring and diagnostics Flexible Configurations: Options for tower or rackmount installations to suit various environments Conclusion Vertiv\'s three-phase UPS systems provide robust and reliable power protection for critical applications, ensuring the availability and integrity of essential systems in data centers and other mission-critical environments.

Send Message
product image
UPS

Emerson offers a variety of Uninterruptible Power Supply (UPS) systems designed to provide reliable power protection for critical applications. Here’s an overview of their offerings: General Specifications: Types: Modular, transformerless, and line-interactive UPS systems. Input Voltage Range: Typically - Input Voltage Range: Typically 100V to 240V depending on the model. Output Voltage: Pure sine wave output for compatibility with sensitive electronic equipment. Form Factor: Available in both tower and rack-mount configurations. Key Models: 1. Emerson Liebert GXT5 Series: Ideal For: Data centers and critical IT applications. Features: High efficiency with online double-conversion technology. LCD display for real-time monitoring and diagnostics. Scalable runtime with external battery cabinets. Models: GXT5-1000RT120: 1000VA/900W GXT5-1500RT120: 1500VA/1350W GXT5-3000RT120: 3000VA/2700W 2. Emerson Liebert PSI5 Series: Features: Compact design suitable for small to medium-sized applications. USB and serial communication ports for monitoring. Built-in battery management for extended life. Models: PSI5-1000RT120: 1000VA/800W PSI5-1500RT120: 1500VA/1200W 3. Emerson Liebert APM Series: Features: Modular design for scalability and redundancy. High efficiency and low total cost of ownership. Advanced monitoring and management capabilities. Models: APM-10K: 10kVA modular UPS. APM-20K: 20kVA modular UPS. Key Features Across Models: High Efficiency: Many models offer efficiencies of 95% or higher, reducing energy costs. Advanced Monitoring: Options for remote monitoring and management through software solutions. Flexible Configuration: Supports various installation environments and requirements. Applications: Data Centers: Protects critical servers and networking equipment. Healthcare: Ensures reliable power for medical devices and systems. Industrial: Supports machinery and equipment during power interruptions. Advantages: Robust Power Protection: Safeguards against power disturbances and outages. User -Friendly Management: Easy to monitor and manage through LCD displays and software. Scalability: Modular options allow for future expansion as power needs grow. Emerson UPS systems are designed to deliver reliable power protection and management solutions tailored to the needs of various industries, ensuring that critical systems remain operational during power disruptions.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
UPS

Vertiv Liebert EXS 80kVA UPS Specifications and Details The Vertiv Liebert EXS is a high-performance uninterruptible power supply (UPS) designed for critical applications requiring reliable power protection. Below are the detailed specifications and features of the Liebert EXS model, which covers the 30-80 kVA range. Key Specifications Model Range: Vertiv Liebert EXS (30-80 kVA) Capacity: Power Rating: Available in 30 kVA, 40 kVA, 60 kVA, and 80 kVA configurations. Input Voltage: Typically operates at 208/220/230/240 VAC. Output Voltage: Configurable to match the input voltage. Phase: Three-phase input and output. Battery Type: Sealed lead-acid or lithium-ion options available. Physical Dimensions Height: Varies by model; typically around 1, 800 mm. Width: Varies by model; typically around 600 mm. Depth: Varies by model; typically around 800 mm. Weight: Varies by model; typically between 500 kg to 800 kg. Features High Efficiency: Offers up to 96% efficiency in double conversion mode, reducing energy costs and heat generation. Scalability: Modular design allows for easy scalability to meet growing power needs. Advanced Monitoring: Equipped with a user-friendly LCD display for real-time monitoring of UPS status and performance metrics. Flexible Configuration: Supports various configurations including parallel operation for redundancy and increased capacity. Smart Battery Management: Extends battery life through intelligent charging and discharging cycles. Environmental Compliance: Designed to meet global environmental standards, including RoHS compliance. Additional Information Output Waveform: Pure sine wave output for compatibility with sensitive electronic equipment. Communication Options: Multiple communication interfaces including SNMP, Modbus, and USB for integration with building management systems. Runtime Performance: Configurable runtime based on battery capacity and load requirements. Conclusion The Vertiv Liebert EXS 30-80kVA UPS is an ideal solution for data centers, industrial applications, and critical infrastructure requiring robust power protection. Its high efficiency, scalability, and advanced monitoring capabilities make it a reliable choice for ensuring continuous power supply and protecting sensitive equipment from power disturbances.

Send Message
product image
Vertiv Data Center Ups

Vertiv is a well-known provider of critical digital infrastructure and continuity solutions, including uninterruptible power supplies (UPS) for data centers. They offer a variety of UPS systems designed to meet the needs of different types of data centers, from small edge installations to large enterprise facilities. Here are some of the main types of UPS systems offered by Vertiv: 1. Single-Phase UPS Vertiv Liebert GXT5: A compact UPS designed for small to medium data centers, offering high efficiency and power density. Vertiv Liebert PSI5: A line-interactive UPS that provides reliable power protection for small IT environments. 2. Three-Phase UPS Vertiv Liebert EXS: A modular UPS solution that offers scalability and flexibility for medium to large data centers. Vertiv Liebert APM: A highly efficient UPS designed for large enterprise environments, providing advanced features and high availability. Vertiv Liebert NXC: A robust UPS solution designed for mission-critical applications, offering high efficiency and reliability. 3. Modular UPS Vertiv Liebert DPA: A modular UPS system that allows for incremental capacity upgrades, making it ideal for growing data centers. 4. Flywheel UPS Vertiv Liebert FPC: A flywheel energy storage system that provides short-term backup power and is often used in conjunction with traditional UPS systems for enhanced reliability. 5. Lithium-Ion UPS Vertiv Liebert APS: A UPS system that utilizes lithium-ion battery technology for longer life and reduced maintenance compared to traditional lead-acid batteries. 6. Eco-Friendly Solutions Vertiv also focuses on energy-efficient and environmentally friendly solutions, such as systems that comply with various sustainability standards and regulations. Key Features Scalability: Many Vertiv UPS systems are designed to be modular, allowing for easy expansion as data center needs grow. Efficiency: High-efficiency designs help reduce energy costs and improve overall sustainability. Advanced Monitoring: Vertiv offers solutions with integrated monitoring capabilities, allowing for real-time performance tracking and proactive maintenance alerts. Redundancy Options: Many systems support N+1 or 2N configurations for enhanced reliability. Applications Enterprise Data Centers: Large facilities requiring high availability and redundancy. Edge Computing: Solutions designed for smaller, distributed data centers. Telecommunications: Power protection for critical telecom infrastructure. Healthcare: Ensuring uptime for critical medical equipment and data. When choosing a UPS system, it's essential to consider factors such as load requirements, runtime needs, efficiency, and the specific environment in which the UPS will operate. For the most accurate and tailored solutions, it's advisable to consult with a Vertiv representative or a certified distributor.

Send Message
product image
UPS

The Vertiv Black UPS is a high-capacity uninterruptible power supply solution that offers maximized reliability and resilience, modular architecture, and high efficiency. It is ideal for medium to large data centers that are facing growing power demands. **Technical Specifications ** Brand: Vertiv Model Name/Number: Liebert GXT5 Lithium-Ion N Online UPS Capacity: 3000VA/2700W 120V Rack/Tower Input Voltage: 120V Output Voltage: 120V Battery Type: Lithium-Ion Runtime: Up to 13 minutes at full load Key Features Superior Battery Technology: Lithium-Ion batteries require fewer battery replacements and last up to 3x as long as traditional VRLA batteries, reducing maintenance, labor, and replacement costs. High Performance: Lithium-Ion battery technology offers better performance at higher temperatures, supports up to 10 times more discharge cycles, and delivers faster recharge times compared to VRLA batteries. Easy Installation: Hot-swappable, user-replaceable batteries may increase the useable life of the UPS by allowing you to easily replace the batteries, if needed, without disrupting power to connected equipment. Scalable Runtime: The UPS has an external battery connector, which is a scalable runtime solution for extended outage protection. (Up to (8) External Battery Cabinets (EBCs)) Remote Management Capability: The RDU101 SNMP/Webcard included with the UPS and FREE Power Insight (Network Management Software) allow you remote infrastructure visibility. Application Areas Server Rooms Network Closets Edge or Distributed IT Locations Critical IT Applications

Send Message

Still searching for
ideal modular power protection?