UPS

The VERTIV Liebert ITON CX 1000VA UPS is a line-interactive uninterruptible power supply designed for home and small office use. Below are the details regarding its unboxing and quick testing. Unboxing Details Packaging: The UPS comes securely packaged to prevent damage during transit. Ensure to check for any visible signs of damage upon receipt. Included Items: VERTIV Liebert ITON CX 1000VA UPS unit User manual and installation guide Power cord with UK outlet Warranty card Initial Inspection: Check the UPS for any physical damage. Verify that all components are included as per the manual. Quick Test Procedure Setup: Place the UPS in a well-ventilated area. Connect the power cord to the UPS and plug it into a wall outlet. Power On: Press the power button to turn on the UPS. Observe the LED indicators: Green Light: Indicates AC mode (normal operation). Red Light: Indicates a fault condition. Battery Mode Test: To test the battery mode, disconnect the UPS from the wall outlet. Ensure that the UPS switches to battery mode automatically. Check the runtime by connecting a load (e.g., a computer) and monitor how long the UPS can sustain power. Load Testing: Connect a load that draws approximately 120W (e.g., a standard desktop computer). Monitor the backup time, which should be around 30 minutes under this load. Recharge Time: After the test, reconnect the UPS to the wall outlet. Note that the typical recharge time is 6-8 hours to reach 90% capacity. Key Specifications Power Capacity: 1000 VA / 600 Watts Input Voltage: 220/230 VAC Output Waveform: Simulated Sine Wave Transfer Time: 2-6 ms Battery Type: 12 V / 7 Ah x 2 Typical Backup Time: 30 minutes at 120W load Dimensions: 369 x 141 x 160 mm Weight: 10 kg Conclusion The VERTIV Liebert ITON CX 1000VA UPS is a reliable solution for power protection in small setups. The unboxing and quick test confirm its functionality and performance, making it a suitable choice for users needing uninterrupted power supply for their electronic devices. Always refer to the user manual for detailed instructions and safety precautions.

Send Message
product image
UPS Rental & UPS Repairing Service

Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems: Repair Process Initial Assessment Gather Information: Document symptoms such as alarms, performance issues, or failure to start. Visual Inspection: Look for signs of physical damage, burnt components, or loose connections. Diagnosis Self-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes. Multimeter Testing: Use a multimeter to check voltage levels, current, and resistance. Battery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity. Inspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault. Common Issues Battery Failure: The most common issue; batteries may need replacement due to age or improper charging. Capacitor Issues: Capacitors can degrade over time, leading to performance problems. Overheating: Caused by dust accumulation, blocked ventilation, or fan failure. Control Board Failures: Issues with the control board can affect functionality. Input/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues. Repair and Replacement Battery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity. Component Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics. Soldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board. Firmware Updates: If applicable, update the firmware for optimal performance. Testing After Repair Functional Testing: Run the UPS to ensure it operates correctly. Load Testing: Test under load conditions to verify performance and capacity. Battery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected. Final Inspection Safety Checks: Verify that all repairs meet safety standards. Documentation: Record all repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct periodic self-tests and inspections to identify potential issues early. Battery Maintenance: Keep battery terminals clean and ensure connections are tight. Cooling: Ensure proper ventilation around the UPS to prevent overheating. Environment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures. When to Seek Professional Help If issues are complex or beyond basic troubleshooting, consult a professional service. Use authorized Vertiv service centers for repairs to ensure quality and warranty compliance. Conclusion Repairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.

Send Message
product image
UPS Repair

Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations: UPS Repair Process Initial Assessment Identify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms. Visual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections. Diagnosis Self-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues. Multimeter Testing: Measure voltage, current, and resistance to identify electrical issues. Battery Testing: Check the health of the batteries using a battery tester or multimeter. Check Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning. Common Issues Battery Failure: Batteries may need replacement due to age or over-discharge. Capacitor Issues: Capacitors can fail due to heat or age, leading to performance issues. Cooling Problems: Blocked fans or insufficient ventilation can cause overheating. Control Board Malfunctions: Issues with the control board can affect the UPS's operation. Input/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry. Repair and Replacement Battery Replacement: Remove and replace old batteries with new ones of the same specifications. Component Replacement: Replace faulty capacitors, fuses, or other components as diagnosed. Resoldering Connections: Fix any broken or loose solder joints on the circuit board. Software/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance. Testing After Repair Functional Testing: After repairs, perform a complete functional test of the UPS. Load Testing: Test the UPS under load to ensure it can handle the required capacity. Battery Cycle Testing: Run the UPS on battery power to check for proper operation. Final Inspection Safety Check: Ensure all repairs meet safety standards. Documentation: Document the repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct regular self-tests and inspections to catch issues early. Battery Maintenance: Check battery connections and terminals periodically; keep them clean and tight. Environment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan. Firmware Updates: Keep the UPS firmware updated for improved performance and security. Professional Repair Services When to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional. Authorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs. Conclusion Repairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.

Send Message
product image
Vertiv PowerBank 600 kVA Online UPS

Vertiv PowerBank 600 kVA Online UPS The Vertiv PowerBank 600 kVA Online UPS is designed for critical power applications, particularly in data centers and industrial environments. Here’s a comprehensive overview of its specifications, features, benefits, and considerations: Overview The Vertiv PowerBank 600 kVA UPS provides robust, uninterrupted power supply with advanced features for high availability, power quality, and energy efficiency. Key Specifications Power Rating: 600 kVA Input Voltage: Typically 400/415V (three-phase) Output Voltage: 400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion Efficiency: Up to 95% in normal operation and can reach 98% in eco mode Total Harmonic Distortion (THD): Typically <5% at full load Battery and Runtime Battery Type: Usually utilizes VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Configuration: Configurable based on requirements, with options for extended runtime Charging Time: Typically 4-8 hours for a full charge, depending on the battery type Runtime: Customizable based on load; options available for longer runtimes (requires additional battery packs) Features Advanced Monitoring: LCD display for real-time monitoring of status, input/output voltage, load percentage, battery status, and alarms. Redundancy: N+1 configuration for enhanced reliability and availability. Scalability: Capable of parallel operation with multiple units for increased capacity and redundancy. Smart Communication: SNMP, USB, and RS232 interfaces for remote management and monitoring. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Hot-Swap Batteries: Some configurations allow for battery replacement without turning off the UPS. Physical Characteristics Dimensions: Varies by model; typically around 120-150 cm in width and depth. Weight: Approximately 600-800 kg, depending on the configuration and battery type. Cooling: Generally air-cooled; ensure proper ventilation in the installation area. Benefits Power Quality: Provides clean, stable, and regulated power to sensitive equipment. High Availability: Designed for critical loads requiring uninterrupted power supply. Energy Efficiency: High-efficiency modes help reduce operational costs. User-Friendly: Intuitive interface and comprehensive management software facilitate easy operation. Considerations Installation: Professional installation is recommended to optimize configuration and ensure compliance with electrical standards. Maintenance: Regular inspections and battery maintenance are crucial for ensuring reliability and longevity. Environmental Conditions: Requires proper ventilation and should be installed in a climate-controlled environment to avoid overheating. Cost: Initial investment can be substantial; consider the total cost of ownership, including maintenance and energy savings. Applications Data Centers Telecommunications Infrastructure Industrial Power Applications Medical Facilities Financial Institutions Conclusion The Vertiv PowerBank 600 kVA UPS is a powerful and reliable solution for ensuring continuous power supply and protecting critical infrastructure.

Send Message
product image
Vertiv 40Kva Online Ups In udhyog vihar Gurgaon

The Vertiv 40 kVA UPS is designed to provide robust power protection and management for critical infrastructure in data centers, IT rooms, and industrial applications. It ensures that sensitive equipment remains operational during power disturbances. Key Specifications Power Rating: 40 kVA Input Voltage: Typically 380/400/415V (three-phase) Output Voltage: 380/400/415V (three-phase) Frequency: 50/60 Hz (auto-sensing) Topology: Online double-conversion or line-interactive Efficiency: Up to 96% in eco mode Total Harmonic Distortion (THD): <5% at full load Battery and Runtime Battery Type: Typically uses VRLA (Valve-Regulated Lead Acid) or Lithium-ion batteries Battery Capacity: Varies based on configuration; options for extended runtime Charging Time: Usually 4-8 hours for a full charge (depending on battery type) Runtime: Configurable based on load; options for longer runtimes available Features Redundancy: N+1 configuration allows for increased reliability. Scalability: Can be expanded with additional units for greater capacity or redundancy. Smart Monitoring: Advanced LCD display for real-time monitoring of UPS status, input/output voltage, load percentage, battery status, and alarms. Communication Options: SNMP, USB, RS232, and optional network management cards for remote management. Bypass Switch: Manual bypass switch allows for maintenance without downtime. Physical Characteristics Dimensions: Varies by model; generally within 60-80 cm in width and depth Weight: Approximately 200-400 kg (depends on battery configuration) Cooling: Typically air-cooled; ensure adequate airflow in the installation environment. Benefits Power Quality: Provides clean and stable power to connected equipment. High Availability: Ensures uptime for critical loads. Flexibility: Suitable for a wide range of applications including data centers, telecommunications, and industrial systems. User-Friendly: Intuitive interface and management software for easy operation and monitoring. Considerations Installation: Professional installation recommended to ensure optimal configuration. Maintenance: Regular inspections and battery replacements are crucial for reliability. Environment: Needs proper ventilation; avoid humid or extreme temperature environments. Cost: Initial investment can be significant; consider total cost of ownership including maintenance and energy savings. Applications Data Centers IT Infrastructure Telecommunications Industrial Equipment Medical Equipment Conclusion The Vertiv 40 kVA UPS is a versatile and powerful solution for ensuring continuous power availability and protecting critical infrastructure.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Exide Battery

Exide Insta Brite is a range of automotive batteries known for providing reliable and high-performance power to vehicles. The Insta Brite series is specially designed to deliver superior cranking power, longer battery life, and low maintenance requirements, making it a popular choice for a wide range of vehicles. Below are the key features and details of Exide Insta Brite batteries: 1. Key Features: High Cranking Power: Provides excellent starting power for engines, even under extreme weather conditions (both hot and cold). Maintenance-Free: Exide Insta Brite batteries are designed to be virtually maintenance-free, reducing the need for constant checks and refills. Durability: Built with robust construction to handle tough environments, ensuring a longer lifespan and reliable performance. Enhanced Safety: These batteries come with advanced safety features, reducing the risk of leakage or damage. Shock and Vibration Resistance: Built to withstand shocks and vibrations that are common in automotive applications. 2. Technology: Lead-Acid Technology: Like most automotive batteries, Exide Insta Brite uses lead-acid technology, which ensures high performance, reliability, and cost-effectiveness. Calcium-Calcium Technology: Some variants of Exide Insta Brite incorporate calcium-calcium technology, which helps in reducing water loss and improving the overall battery performance. Advanced Grid Design: This design improves the efficiency and strength of the battery, enhancing its cranking power and overall battery life. 3. Types of Vehicles: Passenger Cars: Exide Insta Brite is commonly used in standard passenger vehicles like sedans, hatchbacks, and SUVs. Two-Wheelers: Some models are also suitable for motorcycles and scooters. Commercial Vehicles: Some higher-capacity variants are suitable for commercial vehicles, including trucks and buses. 4. Advantages: Longer Life: Designed to provide a longer service life, reducing the frequency of replacements. Excellent Starting Performance: Ensures smooth engine start-ups, especially in cold weather conditions. Cost-Effective: Provides great value by offering a balance of performance, durability, and cost. Environmentally Friendly: Being a lead-acid battery, it is recyclable, making it more eco-friendly than some other types of batteries. 5. Available Sizes/Models: Exide Insta Brite batteries come in different sizes and specifications based on the vehicle’s requirements. These sizes are designed to meet the specific needs of the vehicle, whether it is a compact car or a larger commercial vehicle. 6. Warranty: Exide Insta Brite batteries often come with a manufacturer warranty, typically ranging from 12 months to 36 months depending on the model. The warranty covers manufacturing defects and performance issues, offering peace of mind for the customer. 7. Maintenance: Low Maintenance: While it is a maintenance-free battery, users should still check the battery for any physical damage or signs of wear. Regular Inspections: It's recommended to periodically check the battery's charge level and connections for safety and optimal performance. 8. Application Areas: Automotive: Passenger cars, SUVs, and trucks. Commercial Vehicles: Larger vehicles such as buses and cargo trucks. Motorcycles & Two-Wheelers: Some models are designed for use in motorcycles and scooters. 9. Price Range: The price of Exide Insta Brite batteries typically ranges from INR 3,000 to INR 10,000 or more, depending on the specific model, size, and vehicle type. 10. Availability: Exide Insta Brite batteries are widely available through Exide dealers, automotive battery retailers, and online platforms in various regions. 11. Popular Models in the Insta Brite Series: Exide Insta Brite IB 100: Known for high starting power, suitable for a range of vehicles. Exide Insta Brite IB 120: Offers more power for larger vehicles. Exide Insta Brite IB 150: Ideal for commercial vehicles, providing reliable performance under heavy load conditions.

Send Message
product image
Amaron Quanta 12V 18Ah Battery

The Amaron Quanta 12V 18Ah is a type of sealed lead-acid (SLA) battery, commonly used for backup power applications, such as in UPS systems, inverters, and other critical power supply systems. Here's a detailed breakdown of its specifications and features: 1. General Overview Brand: Amaron Quanta Battery Type: Sealed Lead-Acid (SLA) Battery Voltage: 12 Volts (V) Capacity: 18 Ampere-Hours (Ah) 2. Key Features Longer Battery Life: Amaron Quanta batteries are designed for long-lasting performance and high reliability. They typically offer a good lifespan, especially in applications with a low depth of discharge (DOD). Maintenance-Free: The battery is sealed, so it doesn’t require regular maintenance (e.g., adding water). Vibration Resistance: These batteries are designed to withstand vibrations, making them ideal for use in environments like telecoms, solar power, and UPS systems. Wide Operating Temperature: They can operate in a wide range of temperatures, typically from 0°C to 40°C, making them versatile for use in different climates. 3. Technical Specifications Voltage: 12V (Nominal) Capacity: 18Ah (Ampere-Hours) Dimensions: Length: 181 mm Width: 77 mm Height: 167 mm Weight: Around 5.2 to 5.5 kg (varies slightly based on exact model) Charge Voltage: 14.4V to 15.0V (during charging) Discharge Voltage: Typically 10.5V to 11.0V for complete discharge Self-discharge: Less than 3% per month at 25°C 4. Applications UPS Systems: The 12V 18Ah battery is widely used in smaller uninterruptible power supplies (UPS) for providing backup power to sensitive electronics. Inverters: It can also be used in small-scale inverters to provide backup power to homes or offices. Telecommunications: In telecom applications, these batteries can be used for backup power to critical network equipment. Solar Energy Storage: Sometimes used in small-scale solar energy systems for storing energy for use during off-sunlight hours. 5. Battery Design Features Valve Regulated Lead-Acid (VRLA): The Amaron Quanta battery uses VRLA technology, which means the battery is sealed and uses a valve to release gas in case of overpressure. Deep Cycle: Designed for regular deep discharge cycles, making it suitable for power backup applications where batteries frequently discharge. Absorbent Glass Mat (AGM): Some models use AGM technology, where the electrolyte is absorbed in a fiberglass mat, allowing the battery to be spill-proof and leak-proof. 6. Charge/Discharge Characteristics Charging: Amaron Quanta batteries typically use a constant voltage charge, with a float charge voltage of around 13.5V to 13.8V. Discharge: The battery can typically discharge down to around 10.5V under load, but frequent deep discharges can reduce the battery's overall lifespan. 7. Advantages Longer Service Life: Typically offers a long life when maintained and used properly, making it a cost-effective option for long-term use. Reliable Performance: Known for reliability in maintaining charge over time, especially in demanding environments. Environmentally Friendly: Sealed and maintenance-free design minimizes risks associated with acid leakage and spills. 8. Maintenance Maintenance-Free Design: As mentioned, the battery is sealed, so it doesn't require regular maintenance like adding distilled water. However, regular inspection for corrosion on terminals and proper charge maintenance is recommended. Charging Recommendations: Always charge the battery in accordance with the manufacturer’s recommendations. Overcharging or undercharging can significantly reduce the battery’s lifespan. 9. Warranty Amaron Quanta batteries often come with a warranty that covers defects in material or workmanship, which typically lasts for 1 to 2 years depending on the seller and country-specific terms. 10. Compatibility Compatible Devices: The Amaron Quanta 12V 18Ah battery is commonly used in small UPS systems, solar power applications, and other critical systems where consistent backup power is required. Charging Systems: Can be used with most standard 12V chargers designed for SLA or AGM batteries. Conclusion The Amaron Quanta 12V 18Ah battery is an ideal solution for users looking for a reliable, low-maintenance, and efficient power backup option in smaller systems. It is widely used in UPS systems, inverters, and telecommunications applications where it can provide critical backup power when needed.

Send Message
product image
Amaron GO BATTERY IN DELHI

Amaron GO Car Battery is one of the popular car batteries offered by Amaron, known for its reliable performance, durability, and long lifespan. Here’s a detailed overview of the Amaron GO car battery: Key Features of Amaron GO Car Battery: Technology: Advanced Lead-Acid Technology: The Amaron GO uses lead-acid technology, which is widely used for automotive batteries due to its affordability and effectiveness. HVR (High Vibration Resistance): Designed to withstand high vibrations typically found in modern vehicles, ensuring a longer life even in challenging conditions. Capacity and Voltage: The Amaron GO series offers a wide range of car battery capacities to fit different types of vehicles, typically ranging from 35Ah to 70Ah or higher, with a nominal voltage of 12V. Enhanced Performance: Long Life: Amaron GO batteries are designed for long-lasting performance, offering up to 48 months of warranty (depending on model and usage). Low Maintenance: The Amaron GO is a maintenance-free battery, meaning you don’t need to top it up with water, unlike traditional flooded lead-acid batteries. Leakproof: The battery is designed to prevent leakage, which is a common issue with old or poorly maintained batteries. Durability: Heat Resistance: The Amaron GO car batteries are built to handle extreme weather conditions, making them suitable for both hot and cold climates. Vibration Resistance: With its vibration-resistant design, the battery can last longer even in vehicles that experience high levels of vibration, such as SUVs and trucks. Quick Start Power: The Amaron GO battery is designed to provide strong cranking power for reliable engine starts, even in cold weather conditions. Its quick recharge capability allows your vehicle to return to full charge efficiently. Warranty: Warranty: Typically, the Amaron GO series comes with a 48-month warranty, including a 24-month free replacement and 24-month pro-rata. This warranty may vary depending on your region and the specific model. Applications: Personal Cars: Suitable for most types of personal vehicles like sedans, hatchbacks, and SUVs. Commercial Vehicles: Can also be used for light commercial vehicles, depending on the specific capacity and requirements. Specifications (for a typical Amaron GO battery): Voltage: 12V Capacity: 35Ah, 40Ah, 50Ah, 60Ah, 70Ah (depending on the vehicle model) Cold Cranking Amps (CCA): This varies by battery model, typically ranging from 400 to 650 CCA for vehicles that require more starting power. Warranty: 48 months (subject to terms and conditions). Dimensions: Varies by capacity, but typically around 240mm (L) x 175mm (W) x 190mm (H). Weight: Between 9kg and 20kg, depending on the capacity. Advantages: Maintenance-Free: No need to add water or perform regular maintenance. Reliability: Known for excellent reliability, ensuring consistent performance throughout the year. Long Life and Durability: High durability even in extreme conditions, with a long lifespan and reduced chances of failure. Environmentally Friendly: Made using recyclable materials and follows the necessary environmental standards. Disadvantages: Initial Cost: Amaron batteries might have a higher upfront cost compared to some budget-friendly alternatives, but their longevity and performance can make them a good value over time. Conclusion: The Amaron GO Car Battery is a great choice for vehicle owners looking for a reliable, long-lasting, and maintenance-free battery. Whether you have a compact car, an SUV, or a commercial vehicle, the Amaron GO offers excellent starting power, durability, and performance. With a strong warranty and minimal maintenance requirements, it is a solid option for anyone in need of a quality automotive battery.

Send Message

Still searching for
initial inspection?