UPS ( Uninterrupted Power Supplies)

The Vertiv Liebert Hipulse-U 30kVA UPS is a high-performance uninterruptible power supply designed for critical applications. Here\\\'s an overview of the Vertiv Liebert Hipulse-U 30kVA UPS and its specifications: ** Key Features:** Online double conversion topology for high power quality and reliability 30kVA/30kW power rating with high power factor (0.9-1.0) 3-phase input and 3-phase output configuration Scalable runtime options with matching external battery cabinets ENERGY STAR 2.0 certified for energy efficiency Intuitive gravity sensing full-color LCD display Remote management capabilities with optional Vertiv RDU101 network communications card 3-year comprehensive warranty including battery with options for 2-year extension Technical Specifications: Load Capacity: VA: 30000 VA Watt: 30000 W Output Voltage: 208V AC (3-phase) 400V AC (3-phase) Waveform Type: Pure Sine Wave User Selectable Output: 208/120VAC 400/230VAC Utility (AC) Mode Overload: 105% to 125% for 5 minutes 125% to 150% for 60 seconds Bypass Switch: Automatic & Manual Internal Maintenance Plug/Connector Type: Terminal Block Product Overview: The Vertiv Liebert Hipulse-U 30kVA UPS is designed to protect critical equipment against outages and every type of power disturbance. This 30kVA online double conversion UPS offers continuous power conditioning in centralized and edge locations. With high power factor (0.9-1.0), it allows more connected loads saving space and costs. This tower/rack mount UPS has a built-in Vertiv RDU101 communications card for remote monitoring to help you make more informed decisions and faster event resolution. With the free Vertiv Power Insight software, you can consolidate your view of up to 100 distributed UPS units providing simple notification of status and events in a single pane of glass.

Send Message
product image
Exide Batteries

Exide batteries are known for their reliability and performance, catering to various applications including automotive and industrial use. They offer a range of products, including flat plate flooded lead acid batteries and tubular inverter batteries, designed to meet high standards and operate effectively in diverse conditions. Exide Battery Types Automotive Batteries: Designed for vehicles, ensuring reliable starting power and performance. Available in various models to suit different vehicle types. Xpress Range: Specially designed for the Indian environment, featuring a hybrid alloy system. Enhanced cycle life due to double-clad separation and unique rib-free separator profile. Quick recharge capabilities with a unique tree radial grid design. Maintenance-free with low water loss during high temperatures. Factory-charged and ready to use upon delivery. Key Features Durability: Special polypropylene container withstands severe operating conditions and vibrations. Safety: Micro-porous filter disc in vent openings to prevent acid fumes and spark propagation. Leak-resistant design with a side vented lid to minimize electrolyte leakage. User -Friendly: Magic eye feature for easy monitoring of charge state and electrolyte levels. Requires minimal maintenance, with topping up needed only once every six months. Warranty and Standards Warranty: Comes with a 42-month warranty, ensuring customer satisfaction and reliability. Compliance: Conforms to various standards including IS 14257-1995, JIS-D5301-1999, and IS7372-1995. Applications Energy Storage Solutions: Suitable for both transportation and stationary applications, providing efficient energy storage. Used in various sectors including automotive, industrial, and renewable energy systems.

Send Message
product image
UPS Rental & UPS Repairing Service

Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems: Repair Process Initial Assessment Gather Information: Document symptoms such as alarms, performance issues, or failure to start. Visual Inspection: Look for signs of physical damage, burnt components, or loose connections. Diagnosis Self-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes. Multimeter Testing: Use a multimeter to check voltage levels, current, and resistance. Battery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity. Inspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault. Common Issues Battery Failure: The most common issue; batteries may need replacement due to age or improper charging. Capacitor Issues: Capacitors can degrade over time, leading to performance problems. Overheating: Caused by dust accumulation, blocked ventilation, or fan failure. Control Board Failures: Issues with the control board can affect functionality. Input/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues. Repair and Replacement Battery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity. Component Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics. Soldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board. Firmware Updates: If applicable, update the firmware for optimal performance. Testing After Repair Functional Testing: Run the UPS to ensure it operates correctly. Load Testing: Test under load conditions to verify performance and capacity. Battery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected. Final Inspection Safety Checks: Verify that all repairs meet safety standards. Documentation: Record all repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct periodic self-tests and inspections to identify potential issues early. Battery Maintenance: Keep battery terminals clean and ensure connections are tight. Cooling: Ensure proper ventilation around the UPS to prevent overheating. Environment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures. When to Seek Professional Help If issues are complex or beyond basic troubleshooting, consult a professional service. Use authorized Vertiv service centers for repairs to ensure quality and warranty compliance. Conclusion Repairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.

Send Message
product image
UPS Repair

Repairing uninterruptible power supplies (UPS) involves a series of steps to diagnose and fix issues, ensuring they operate reliably. Here’s a comprehensive overview of the UPS repair process, common issues, and considerations: UPS Repair Process Initial Assessment Identify Symptoms: Gather information on the symptoms or problems, such as failure to start, battery issues, or alarms. Visual Inspection: Check for any visible damage, such as burned components, corrosion, or loose connections. Diagnosis Self-Diagnostics: Utilize built-in self-test features, if available, to diagnose issues. Multimeter Testing: Measure voltage, current, and resistance to identify electrical issues. Battery Testing: Check the health of the batteries using a battery tester or multimeter. Check Fuses and Circuit Breakers: Ensure all fuses and breakers are intact and functioning. Common Issues Battery Failure: Batteries may need replacement due to age or over-discharge. Capacitor Issues: Capacitors can fail due to heat or age, leading to performance issues. Cooling Problems: Blocked fans or insufficient ventilation can cause overheating. Control Board Malfunctions: Issues with the control board can affect the UPS's operation. Input/Output Issues: Problems with input power or output voltage can indicate faults in the UPS circuitry. Repair and Replacement Battery Replacement: Remove and replace old batteries with new ones of the same specifications. Component Replacement: Replace faulty capacitors, fuses, or other components as diagnosed. Resoldering Connections: Fix any broken or loose solder joints on the circuit board. Software/Firmware Updates: If applicable, update the UPS firmware to ensure optimal performance. Testing After Repair Functional Testing: After repairs, perform a complete functional test of the UPS. Load Testing: Test the UPS under load to ensure it can handle the required capacity. Battery Cycle Testing: Run the UPS on battery power to check for proper operation. Final Inspection Safety Check: Ensure all repairs meet safety standards. Documentation: Document the repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct regular self-tests and inspections to catch issues early. Battery Maintenance: Check battery connections and terminals periodically; keep them clean and tight. Environment Control: Ensure the UPS is kept in a cool, dry environment to extend its lifespan. Firmware Updates: Keep the UPS firmware updated for improved performance and security. Professional Repair Services When to Seek Help: If the issue is beyond basic troubleshooting or involves complex repairs, it’s best to consult a professional. Authorized Service Centers: Consider using authorized repair services for specific brands to ensure quality repairs. Conclusion Repairing a UPS requires careful diagnosis, knowledge of electrical systems, and attention to safety. Regular maintenance can help prevent many issues, ensuring your UPS remains reliable in providing backup power when needed. For complex repairs, professional services are recommended to ensure the job is done safely and effectively.

Send Message
product image
UPS

The Vertiv 500 kVA UPS is a high-capacity uninterruptible power supply designed for large data centers, critical infrastructure, and industrial applications. Here are the key details: Specifications Power Rating: 500 kVA Input Voltage: Typically supports 380/400/415V three-phase configurations. Output Voltage: 380/400/415V three-phase. Frequency: 50/60 Hz, auto-sensing. Key Features Double Conversion Technology: Provides clean and stable power by converting AC to DC and then back to AC, ensuring zero transfer time during outages. High Efficiency: Designed for high efficiency, often exceeding 95% in online mode, minimizing energy costs and reducing heat generation. Modular Design: Can be configured in a parallel setup with multiple units for redundancy and increased capacity. Smart Battery Management: Enhances battery performance and lifespan through advanced charging techniques. User-Friendly Interface: Equipped with an LCD touchscreen display for real-time monitoring and easy access to operational data. Physical Characteristics Dimensions: Varies based on the specific model; typically around 1200 mm x 800 mm x 2400 mm (length x width x height). Weight: Approximately 800-1000 kg (exact weight may vary based on configuration). Cooling: Air-cooled; requires adequate space for ventilation. Safety Features Overload Protection: Prevents damage during overload conditions. Short Circuit Protection: Automatically disconnects the unit in case of short circuits. Thermal Protection: Equipped with temperature sensors to prevent overheating. Applications Data Centers: Provides reliable power for IT equipment and servers. Telecommunications: Ensures consistent power for telecom infrastructure. Industrial: Supports critical processes in manufacturing and production environments. Maintenance and Support Service Agreements: Vertiv offers various service plans to ensure reliability and uptime. Remote Monitoring: Many models come with options for remote access and monitoring capabilities. Conclusion The Vertiv 500 kVA UPS is engineered for high performance and reliability, making it suitable for critical applications across various sectors. For specific model details, configurations, pricing, and installation, it is recommended to consult with Vertiv or an authorized distributor.