Faridabad
+918076792323

'modbus'

Items tagged with 'modbus'

product image
40kVA UPS

The Vertiv 40kVA UPS models, such as the Liebert ITA and EXS series, offer robust power protection for critical applications. They feature a power capacity of 40 kVA, double conversion technology, and options for both three-phase and single-phase outputs, ensuring reliable performance and flexibility in installation. Key Specifications: Power Capacity: 40 kVA (40 kW). Input Voltage Range: Typically 176 V AC - 288 V AC. Output Voltage: Configurable options, often 208V or 220V. Form Factor: Available in rack or tower configurations. Efficiency: High efficiency ratings, often exceeding 95%. Communication: Equipped with Vertiv IntelliSlot for SNMP, Modbus, or Relay communication. Battery Type: Generally uses lead-acid batteries with options for extended runtime. Applications: Ideal for data centers, telecommunications, and other critical infrastructure requiring uninterrupted power supply.

Send Message
product image
600kva ups

The Vertiv 600 kVA UPS options include models like the Liebert EXL S1 and Liebert APM. Liebert EXL S1: This model is optimized for efficiency and power density, available in ratings from 250 to 600 kVA. It features a transformer-free design, which contributes to its compact footprint and high operating efficiency. Electrical Input/Output: Designed for robust electrical protection and superior cost savings. Battery Options: Various configurations available to meet specific runtime requirements. Support: Technical consultants are available for assistance with specifications, sizing, and runtime calculations. Liebert APM: This model is designed for critical power applications and offers flexibility in configuration. Topology: Online Double Conversion, ensuring continuous power supply. Runtime: Extended runtime options available with external battery cabinets. Dimensions: UPS: 2000 x 1800 x 1100 mm Battery Frame: 2000 x 2050 x 665 mm Wiring Type: 3-phase wiring for enhanced performance. Warranty: Comes with a 1-year warranty. Communication Management: Options include: Dry Contact SNMP Card Modbus Card RS485 Card Contact and Support: For detailed inquiries or site inspections, customers are encouraged to reach out to Vertiv\'s sales team or authorized resellers for tailored solutions. Contact Information: Email: Info@universalpower.co.in Phone: 8744823336 This information provides a comprehensive overview of the Vertiv 600 kVA UPS options available for critical power applications.

Send Message
product image
UPS

Vertiv Liebert EXS 80kVA UPS Specifications and Details The Vertiv Liebert EXS is a high-performance uninterruptible power supply (UPS) designed for critical applications requiring reliable power protection. Below are the detailed specifications and features of the Liebert EXS model, which covers the 30-80 kVA range. Key Specifications Model Range: Vertiv Liebert EXS (30-80 kVA) Capacity: Power Rating: Available in 30 kVA, 40 kVA, 60 kVA, and 80 kVA configurations. Input Voltage: Typically operates at 208/220/230/240 VAC. Output Voltage: Configurable to match the input voltage. Phase: Three-phase input and output. Battery Type: Sealed lead-acid or lithium-ion options available. Physical Dimensions Height: Varies by model; typically around 1, 800 mm. Width: Varies by model; typically around 600 mm. Depth: Varies by model; typically around 800 mm. Weight: Varies by model; typically between 500 kg to 800 kg. Features High Efficiency: Offers up to 96% efficiency in double conversion mode, reducing energy costs and heat generation. Scalability: Modular design allows for easy scalability to meet growing power needs. Advanced Monitoring: Equipped with a user-friendly LCD display for real-time monitoring of UPS status and performance metrics. Flexible Configuration: Supports various configurations including parallel operation for redundancy and increased capacity. Smart Battery Management: Extends battery life through intelligent charging and discharging cycles. Environmental Compliance: Designed to meet global environmental standards, including RoHS compliance. Additional Information Output Waveform: Pure sine wave output for compatibility with sensitive electronic equipment. Communication Options: Multiple communication interfaces including SNMP, Modbus, and USB for integration with building management systems. Runtime Performance: Configurable runtime based on battery capacity and load requirements. Conclusion The Vertiv Liebert EXS 30-80kVA UPS is an ideal solution for data centers, industrial applications, and critical infrastructure requiring robust power protection. Its high efficiency, scalability, and advanced monitoring capabilities make it a reliable choice for ensuring continuous power supply and protecting sensitive equipment from power disturbances.

Send Message
product image
UPS

Emerson offers a range of three-phase industrial UPS systems designed to provide reliable power protection for critical applications. Here are some key details typically associated with Emerson's three-phase UPS solutions: Key Features Power Capacity: Models often range from 10 kVA to several hundred kVA, catering to different industrial requirements. Topology: Many models utilize an online double-conversion topology, which ensures continuous power supply and zero transfer time during outages. Efficiency: High-efficiency ratings (up to 96% or more) help reduce energy costs and heat generation. Modular Design: Many systems allow for modular configurations, enabling easy scalability and redundancy. Smart Battery Management: Advanced battery management systems extend battery life and enhance performance. User Interface: LCD screens or touchscreen interfaces for real-time monitoring, diagnostics, and control. Communication Protocols: Various options for remote monitoring and integration, including SNMP, Modbus, and other industry-standard protocols. Input/Output Configuration: Flexible I/O options for different electrical environments, often with customizable settings. Applications Data centers Industrial automation systems Telecommunications Manufacturing facilities Critical power applications in healthcare Considerations Installation: Requires professional installation to ensure compliance with local electrical codes and optimal performance. Maintenance: Regular maintenance checks are necessary for reliability; consider a service contract for ongoing support. Load Assessment: Properly assess total load requirements to select the appropriate UPS capacity. Environmental Conditions: Ensure the UPS is suitable for the operating environment (temperature, humidity, etc.). Popular Models Emerson has various models within its UPS lineup, including: Liebert APM: Modular UPS systems known for scalability and high efficiency. Liebert EXL S1: High-density UPS for critical loads, offering excellent performance and efficiency. Conclusion When considering an Emerson three-phase industrial UPS, it's essential to evaluate specific needs, including power requirements, space constraints, and operational conditions. For the most accurate and detailed information, including specifications and installation requirements, consult Emerson's official documentation or contact a local representative. If you have specific models or features in mind, let me know!

Send Message
product image
Vertiv Hiplus 80-800 KVA Online Ups

UPS Renting Services HIPULSE UPS (80-800 KVA) It is a range of uninterruptible power supply (UPS) systems manufactured by a company called HIPULSE. These UPS systems are designed to provide reliable and continuous power protection for a wide range of applications, from small to large-scale industrial and commercial environments. The HIPULSE UPS range typically covers a power capacity range of 80-800 kilovolt-amperes (kVA). Most of Benefits from Universal Power System: Features: On-Line Double C???onversion IGBT-based PWM Inverter Wide input voltage tolerance (+15 / -15%) Wide input frequency tolerance (45Hz-65Hz) Capability to handle: - High crest factor loads - 100% non-linear loads - 100% unbalanced loads Built-in maintenance bypass (Single and 1+N Models) Common battery sharing kit (optional) with 1+1 configuration Built-in maintenance bypass (Single and 1+N Models) Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA UPS Renting Services UPS Renting Services S7400 UPS (10-400 KVA) THE S7400 UPS IS A SERIES OF UNINTERRUPTIBLE POWER SUPPLY (UPS) SYSTEMS MANUFACTURED BY AN UNDISCLOSED COMPANY. THESE UPS SYSTEMS ARE DESIGNED TO PROVIDE RELIABLE AND CONTINUOUS POWER PROTECTION FOR A WIDE RANGE OF APPLICATIONS. THE S7400 SERIES TYPICALLY COVERS A POWER CAPACITY RANGE OF 10 KVA TO 400 KVA. Features: High performance IGBT PWM(Pulse Wave Modification) technology for pure sinewave output LBS configuration for super critical loads True parallelability up to six modules Netcom kit for remote monitoring BMS Connectivity through modbus Remote alarm monitor (RAM) Hardware for Fault Diagnostic Unit (FDU), data logger and power monitoring software Communication card for dial-up monitoring UPS Series 7400 The Series 7400 UPS offers True On-line Field Proven UPS system to maximize Uptime of your Critical Application. The Series 7400 offers a wide range from 10 kVA to 750 kVA single phase systems. The Series 7400 UPS System has a proven track - record of unmatched reliability to support your sensitive and costly equipment, offering maximum availability to virtually any application. The Series 7400 is carefully designed to address the “load power factor” (0.7 lagging upwards) and “non linearity” that critical applications demand. In-built output isolation transformer To offer galvanic isolation between your critical application and the Mains, while feeding the load through the Inverter. Battery Circuit Breaker (BCB): To ensure “Safety” and to protect your “Battery Life”, unlike using DC Isolator. Usage of BCB is much safer in terms of personal hazards on a running system than a DC Isolator. Under Voltage Trip coil of BCB prevents deep-discharging of battery, which cannot be achieved by a DC Isolator. RS-232 Serial port : For carrying out on-line monitoring of Alarm and Status. Optional attachments such as IBM-AS 400 Interface Card/ Relay Interface Card help you to integrate the UPS with your network effectively. High efficiency performance High reliability to maximise system availability Handles 3:1 crest factor loads without de-rating

Send Message

Still searching for
modbus?