product image
Vertiv 60 kVA to 200 kVA Ups

The Liebert SX series from Vertiv offers UPS systems ranging from 60 kVA to 200 kVA, utilizing full IGBT double conversion technology. This design enhances efficiency, reduces installation and operational costs, and provides reliable power backup solutions for critical applications. Key Features of Liebert SX 60kVA to 200kVA Modular Design: The Liebert SX series features a modular architecture that allows for easy scalability and maintenance. Front Access Design: This design minimizes repair time and optimizes installation and serviceability, making it user-friendly. Environmental Standards: The Liebert SX series is designed to meet high environmental standards, promoting energy efficiency and sustainability. ID Card for Each UPS: Each unit comes with an ID card that includes all working parameters, which helps in reducing downtime during maintenance. Applications Power Backup: Ideal for critical applications requiring uninterrupted power supply. Data Centers: Suitable for use in data centers where reliability and efficiency are paramount. Industrial Use: Can be utilized in various industrial settings to ensure consistent power availability. Contact Information for Further Inquiries Company: Universal Power System Location: Plot No.-70, Udyog Vihar-VI, Sector-37 Gurugram, Haryana, India -122001 Mobile - 8744823336 Email: info@universalpower.co.in

Send Message
product image
UPS

The Vertiv 1 kVA UPS options primarily include the Liebert GXT MT+ CX4 and Liebert GXT5 models, both designed for reliable power protection and efficiency. Liebert GXT MT+ CX4 (1 kVA): Topology: Online Double Conversion, ensuring a continuous and clean power supply. Efficiency: High efficiency ratings, typically around 94% in online mode. Input Voltage Range: Wide input voltage range to accommodate various power conditions. Battery Options: Configurable with internal and external battery options for extended runtime. Display: LCD display for real-time monitoring of UPS status and parameters. Liebert GXT5 (1 kVA): Topology: Also features Online Double Conversion for superior power quality. Efficiency: Offers up to 95% efficiency in online mode, contributing to lower operational costs. Form Factor: Compact design suitable for rack or tower configurations. Battery Management: Advanced battery management system for optimal battery performance and lifespan. Communication: Equipped with multiple communication options, including USB, RS232, and SNMP for remote monitoring. Key Features: Protection: Provides protection against power disturbances such as surges, spikes, and outages. Scalability: Can be integrated into larger systems for increased capacity and redundancy. Warranty: Typically comes with a standard warranty, often around 2 years, depending on the model and region. Support and Services: Technical Support: Vertiv offers technical support for installation, maintenance, and troubleshooting. Contact Information: Customers can reach out to Vertiv\'s support team for assistance or inquiries. This overview highlights the essential features and specifications of the Vertiv 1 kVA UPS models, suitable for various applications requiring reliable power protection.

Send Message
product image
UPS

The Vertiv 3 kVA UPS options primarily include the Liebert GXT MT+ and Liebert GXT5 models, both designed for reliable power protection and conditioning. Liebert GXT MT+ (1/2/3 kVA): Topology: Online Double Conversion, ensuring a continuous and clean power supply. Efficiency: High efficiency ratings, typically around 94% in online mode. Input Voltage Range: Wide input voltage range to accommodate various power conditions. Battery Options: Configurable with internal and external battery options for extended runtime. Display: LCD display for real-time monitoring of UPS status and parameters. Liebert GXT5 (1-3 kVA): Topology: Also features Online Double Conversion for superior power quality. Efficiency: Offers up to 95% efficiency in online mode, contributing to lower operational costs. Form Factor: Compact design suitable for rack or tower configurations. Battery Management: Advanced battery management system for optimal battery performance and lifespan. Communication: Equipped with multiple communication options, including USB, RS232, and SNMP for remote monitoring. Key Features: Protection: Provides protection against power disturbances such as surges, spikes, and outages. Scalability: Can be integrated into larger systems for increased capacity and redundancy. Warranty: Typically comes with a standard warranty, often around 2 years, depending on the model and region. Support and Services: Technical Support: Vertiv offers technical support for installation, maintenance, and troubleshooting. Contact Information: Customers can reach out to Vertiv\'s support team for assistance or inquiries. This overview highlights the essential features and specifications of the Vertiv 3 kVA UPS models, suitable for various applications requiring reliable power protection.

Send Message
product image
Online Ups Amc Repair & Services

As a leading provider of UPS services, we understand the criticality of uninterrupted power supply for your business. Our team of highly skilled technicians is dedicated to delivering efficient and reliable online UPS services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . With our expertise and experience, we offer comprehensive solutions for online UPS installation, maintenance, and repair. Whether you are looking for a new installation or need assistance with troubleshooting and repairs, we have got you covered. UPS Repair & Services In Manesar We specialize in UPS Repair & Services in Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . offering professional troubleshooting and repair. Our team is equipped to handle issues of any scale, ensuring your UPS systems are always in top working condition. Maintenance Contract After entering into AMC, the contract will do the 1st preventive maintenance to check UPS condition, Healthy and working UPS only will be considered under AMC and also Faulty will be repaired on chargeable basis before considering it under AMC. If the batteries are found faulty at the time of inspection it will have to be replaced before taking it under AMC. Any make, any capacity (expect Vertiv & Emerson) Unlimited Break Down calls (Except Wire wound components, batteries, transformers). Includes 100% labor and travel coverage 6 days/week, 8 hours/day. Performed by ACCESS factory trained Customer Engineers. Break down calls – UNLIMITED. Subject to all Terms & Conditions as noted in the ACCESS Maintenance Agreement. 8 Hours Turnaround Time. Preventive Service Preventive Measurement : 4 PM per year Cleaning up of Unit, Visual Inspection tocheck any deformation. Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current. Checking and Adjustment (If needed) of Control parameters on different PCBs. Tightness of all connections, if shut down possible. Functional Checking up of Rectifier section. Functional Checking up of Inverter section. Functional Checking up of Static Switch Section. With customer approval, perform operational tests of the system including unit transfer and battery discharge. Maintaining the posted checklist at the client place. Battery Health checks with Multi Meter. Battery AMC Introducing for the very first time in the Industry “Battery AMC”, wherein you get your additional 3rd year warranty only @15% of your previous pay for the batteries. Quanta Amaron Make of battery is only included in AMC. Battery should be within the warranty period. Currently AMC will be carried forward only for Gurgaon, Delhi, Noida, Bawal, Bhiwadi, Manesar, Sonipat , Faridabad . Region. UPS Renting Cost Effective: Rental UPS is very cost effective, you can save on huge project costs. Power Stability: Provides stable power continuously and saves all your expensive equipment from Power Surges. No Minimum Requirements: Online UPS available from 1KVA to 600 KVA on rent for short & long term. No Maintenance Cost: UPS Rental helps you save on maintenance & Servicing cost. Customisable: Special customization facility available for your specific needs. No Power Cuts: Battery life is always ON, due to immediate replacement facility. Maintenance Contracts On line ups in each kVA rating and battery backup system are very sensitive issues and so it should be taken care utmost to enhance the life of UPS system and battery life for almost 99% up time during performance. Access Power Link is a leader in this market for 25 years having expertise and experience in the field to ensure hassle-free UPS AMC services on PAN INDIA level. UPS Servicing To Suit You Our response time is the time to get to site, not the time for a callback Travel and labour is included in all contract prices unless not required Our technical support is offered by actual UPS experts, not a call centre. Our inclusive parts contracts include ALL parts not just “consumables”. Our preventative maintenance includes multipoint checks not just visuals. We offer different plans to pass on savings during normal working hours.

Send Message
product image
Rental And Maintenance

Here are the key details about UPS and batteries rental and maintenance: What is UPS and Batteries Rental? UPS and batteries rental is a service that provides temporary or long-term rental of UPS systems and batteries to meet your power backup needs. This service is ideal for organizations that require a reliable power backup solution for a short period or for those who do not want to invest in purchasing a UPS system. Benefits of UPS and Batteries Rental Cost-Effective: Rental options are often more cost-effective than purchasing a UPS system, especially for short-term needs. Flexibility: Rental options provide flexibility to upgrade or downgrade your power backup solution as needed. Quick Deployment: Rental UPS systems and batteries can be quickly deployed to meet your power backup needs. Types of UPS and Batteries Rental Short-Term Rental: Rental options for a short period, typically for events or temporary power backup needs. Long-Term Rental: Rental options for an extended period, typically for organizations that require a reliable power backup solution for an extended period. Customized Rental: A tailored rental solution that meets the specific needs of your organization. What is UPS and Batteries Maintenance? UPS and batteries maintenance is a service that ensures the smooth functioning of your UPS system and batteries. This service includes regular maintenance, repairs, and replacement of parts to prevent downtime and data loss. Benefits of UPS and Batteries Maintenance Reduced Downtime: Regular maintenance ensures that your UPS system and batteries are functioning properly, reducing the risk of downtime and data loss. Extended Equipment Life: Maintenance helps to extend the life of your UPS system and batteries by identifying and replacing worn-out parts. Priority Support: With a maintenance contract, you get priority support and response times, ensuring that your issues are resolved quickly. Services Covered Under UPS and Batteries Maintenance Regular Maintenance: Scheduled maintenance visits to ensure the UPS system and batteries are functioning properly. Repair and Replacement: Repair or replacement of faulty parts to ensure the UPS system and batteries are functioning at optimal levels. Battery Testing and Replacement: Testing and replacement of batteries to ensure they are functioning within specified parameters. UPS System Testing: Testing of the UPS system to ensure it is functioning properly and providing clean power to your equipment. Types of UPS and Batteries Maintenance Comprehensive Maintenance: Covers all maintenance, repairs, and replacement of parts. Non-Comprehensive Maintenance: Covers only maintenance and repairs, with replacement of parts at an additional cost. Customized Maintenance: A tailored maintenance solution that meets the specific needs of your organization. Why is UPS and Batteries Rental and Maintenance Important? Business Continuity: UPS and batteries rental and maintenance ensure that your business remains operational even during power outages, reducing the risk of data loss and downtime. Data Protection: Rental and maintenance services help to protect your critical data by ensuring that your UPS system and batteries are functioning properly. Equipment Protection: Rental and maintenance services help to protect your equipment from power surges and spikes, reducing the risk of damage and downtime.

Send Message
product image
Ups Battery

UPS (Uninterruptible Power Supply) and batteries AMC (Annual Maintenance Contract) is a service agreement that ensures the smooth functioning of your UPS system and batteries. Here are the key details: What is UPS and Batteries AMC? UPS and Batteries AMC is a comprehensive maintenance program designed to ensure the reliability and performance of your UPS system and batteries. The AMC provides regular maintenance, repairs, and replacement of parts to prevent downtime and data loss. Benefits of UPS and Batteries AMC Reduced Downtime: Regular maintenance ensures that your UPS system and batteries are functioning properly, reducing the risk of downtime and data loss. Extended Equipment Life: The AMC helps to extend the life of your UPS system and batteries by identifying and replacing worn-out parts. Priority Support: With an AMC, you get priority support and response times, ensuring that your issues are resolved quickly. Cost Savings: The AMC helps to reduce costs by identifying and fixing potential issues before they become major problems. Services Covered Under UPS and Batteries AMC Regular Maintenance: Scheduled maintenance visits to ensure the UPS system and batteries are functioning properly. Repair and Replacement: Repair or replacement of faulty parts to ensure the UPS system and batteries are functioning at optimal levels. Battery Testing and Replacement: Testing and replacement of batteries to ensure they are functioning within specified parameters. UPS System Testing: Testing of the UPS system to ensure it is functioning properly and providing clean power to your equipment. Types of UPS and Batteries AMC Comprehensive AMC: Covers all maintenance, repairs, and replacement of parts. Non-Comprehensive AMC: Covers only maintenance and repairs, with replacement of parts at an additional cost. Customized AMC: A tailored AMC that meets the specific needs of your organization. Why is UPS and Batteries AMC Important? Business Continuity: UPS and Batteries AMC ensures that your business remains operational even during power outages, reducing the risk of data loss and downtime. Data Protection: The AMC helps to protect your critical data by ensuring that your UPS system and batteries are functioning properly. Equipment Protection: The AMC helps to protect your equipment from power surges and spikes, reducing the risk of damage and downtime.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
APC 6000VA UPS

The APC Smart-UPS RT 6000VA is a high-performance uninterruptible power supply (UPS) designed to provide reliable power protection for critical equipment in various settings such as data centers, server rooms, and industrial environments. Here are some key features and specifications: Key Features: Power Capacity: 6000VA / 4800W – Suitable for medium-to-large systems that need substantial power backup. Rack-Mountable Design: The UPS can be mounted in a 19-inch rack, making it ideal for environments that require a space-efficient solution. Extended Runtime: It provides sufficient runtime to safely shut down connected equipment or continue operations during short power outages, depending on the load. Pure Sine Wave Output: Ensures high-quality power to sensitive equipment, avoiding power disturbances such as harmonic distortion or voltage spikes. Hot-Swappable Batteries: Allows for maintenance without powering down the UPS, increasing uptime and operational efficiency. LCD Display: A user-friendly LCD display provides detailed information about the UPS status, including input/output voltage, battery charge, and runtime. Extended Battery Options: Can be connected to external battery packs for increased runtime in case of prolonged power outages. Advanced Communication Features: Offers a variety of communication options such as USB, RS-232, or SNMP for monitoring and management. It’s compatible with APC’s PowerChute management software. Environmental Monitoring: Some models include environmental sensors to monitor conditions like temperature and humidity, ensuring the UPS operates in optimal conditions. Safety Features: It includes features such as overload protection, short-circuit protection, and battery optimization to ensure safe and efficient operation. Ideal Use Cases: Data Centers Server Rooms Network Equipment Industrial and Medical Equipment

Send Message
product image
VERTIV UPS

The Liebert APM is a modular, scalable, and flexible Uninterruptible Power Supply (UPS) system from Vertiv (formerly Emerson Network Power). It's designed to provide reliable power protection for a wide range of applications, including IT, industrial, healthcare, and telecommunication environments. The Liebert APM series comes in various power ratings, with the range you mentioned being 30 kW - 300 kW, as well as the smaller 1 to 25 kVA units, offering high flexibility for different power requirements. Key Features of the Liebert APM Series: Modular Design: One of the standout features of the Liebert APM UPS system is its modular design. This allows users to scale the system based on their current needs and future expansion. The modular units can be added incrementally, making it highly adaptable. This modular approach allows for easy maintenance and upgrades without having to replace the entire UPS unit. High Efficiency: The Liebert APM delivers high efficiency, typically achieving up to 95% or more under normal operating conditions. This efficiency helps reduce operational costs and energy consumption. It also features Eco-mode operation, which optimizes energy savings when operating in non-critical situations without compromising protection. Compact and Flexible: Despite its modular nature, the Liebert APM system has a compact design that fits easily into most data centers and industrial setups, where space can often be at a premium. It can be configured for 1-phase or 3-phase power supply, offering flexibility for different types of loads and systems. Scalable Power: The Liebert APM is available in a range from 1 kVA to 300 kVA, which makes it suitable for small server rooms to large data centers. The system allows for easy scalability by adding additional power modules as needed to meet growing demands. Flexible Battery Configurations: The UPS system supports a variety of battery configurations, allowing for customization based on your runtime requirements. You can select from different battery types, including VRLA (Valve-Regulated Lead-Acid) and lithium-ion batteries. Advanced Monitoring and Management: Liebert APM comes with Intelligent Monitoring that provides real-time data on the UPS’s performance, such as input/output voltage, battery status, and efficiency. It supports both local and remote monitoring, ensuring that technicians can be alerted to issues before they become critical problems. The system can be integrated with network management systems (NMS) for centralized control across multiple units. Dual Input Capability: Some models of the Liebert APM offer dual input power sources, providing redundancy for critical applications. This feature ensures that the system remains operational even if one power input fails. Fast Response Time: The Liebert APM offers a fast transfer time (typically in the milliseconds), ensuring that sensitive equipment is protected even during brief power outages or voltage fluctuations. Applications: Data Centers: Providing reliable, scalable power protection for server rooms and IT infrastructure. Industrial: Protecting critical manufacturing equipment and automated systems from power interruptions. Healthcare: Ensuring medical equipment, including imaging devices, lab instruments, and patient monitoring systems, remain operational during power outages. Telecommunications: Keeping communication systems up and running to ensure continuous operation of vital network infrastructure. Benefits: Scalability: The ability to scale up or down as required, which is a huge benefit for growing businesses or changing environments. Reduced Total Cost of Ownership (TCO): With high efficiency and modularity, the Liebert APM reduces energy consumption and minimizes the cost of maintenance. Reliability: Known for providing excellent protection against power issues, including surges, spikes, and outages. Customization: Supports different configurations and battery options to meet specific needs, offering flexibility across various industries. Models & Power Ratings: Small Power Ratings: For smaller environments or edge computing setups, Liebert APM models ranging from 1 kVA to 25 kVA offer robust protection without being overly complex. Large Power Ratings: For larger industrial or data center applications, the 30 kW to 300 kW versions provide scalable power protection to ensure high availability for critical operations.