Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Ups Battery

UPS (Uninterruptible Power Supply) and batteries AMC (Annual Maintenance Contract) is a service agreement that ensures the smooth functioning of your UPS system and batteries. Here are the key details: What is UPS and Batteries AMC? UPS and Batteries AMC is a comprehensive maintenance program designed to ensure the reliability and performance of your UPS system and batteries. The AMC provides regular maintenance, repairs, and replacement of parts to prevent downtime and data loss. Benefits of UPS and Batteries AMC Reduced Downtime: Regular maintenance ensures that your UPS system and batteries are functioning properly, reducing the risk of downtime and data loss. Extended Equipment Life: The AMC helps to extend the life of your UPS system and batteries by identifying and replacing worn-out parts. Priority Support: With an AMC, you get priority support and response times, ensuring that your issues are resolved quickly. Cost Savings: The AMC helps to reduce costs by identifying and fixing potential issues before they become major problems. Services Covered Under UPS and Batteries AMC Regular Maintenance: Scheduled maintenance visits to ensure the UPS system and batteries are functioning properly. Repair and Replacement: Repair or replacement of faulty parts to ensure the UPS system and batteries are functioning at optimal levels. Battery Testing and Replacement: Testing and replacement of batteries to ensure they are functioning within specified parameters. UPS System Testing: Testing of the UPS system to ensure it is functioning properly and providing clean power to your equipment. Types of UPS and Batteries AMC Comprehensive AMC: Covers all maintenance, repairs, and replacement of parts. Non-Comprehensive AMC: Covers only maintenance and repairs, with replacement of parts at an additional cost. Customized AMC: A tailored AMC that meets the specific needs of your organization. Why is UPS and Batteries AMC Important? Business Continuity: UPS and Batteries AMC ensures that your business remains operational even during power outages, reducing the risk of data loss and downtime. Data Protection: The AMC helps to protect your critical data by ensuring that your UPS system and batteries are functioning properly. Equipment Protection: The AMC helps to protect your equipment from power surges and spikes, reducing the risk of damage and downtime.

Send Message
product image
UPS Rental & UPS Repairing Service

Repairing a Vertiv 1 kVA UPS involves a systematic approach to diagnosing and fixing issues. Here’s a detailed overview of the repair process, common problems, and considerations specific to Vertiv UPS systems: Repair Process Initial Assessment Gather Information: Document symptoms such as alarms, performance issues, or failure to start. Visual Inspection: Look for signs of physical damage, burnt components, or loose connections. Diagnosis Self-Diagnostic Tests: Many Vertiv UPS units have built-in diagnostic tools. Run these tests to identify fault codes. Multimeter Testing: Use a multimeter to check voltage levels, current, and resistance. Battery Health Check: Test the battery using a dedicated battery tester or multimeter to check for voltage and capacity. Inspect Fuses and Circuit Breakers: Check for blown fuses or tripped circuit breakers that could indicate a fault. Common Issues Battery Failure: The most common issue; batteries may need replacement due to age or improper charging. Capacitor Issues: Capacitors can degrade over time, leading to performance problems. Overheating: Caused by dust accumulation, blocked ventilation, or fan failure. Control Board Failures: Issues with the control board can affect functionality. Input/Output Problems: Fluctuations in input power or output voltage can indicate deeper electrical issues. Repair and Replacement Battery Replacement: Carefully remove old batteries and install new ones, ensuring correct polarity. Component Replacement: Replace any faulty components, such as capacitors or fuses, as identified during diagnostics. Soldering and Repairing Connections: Resolder any loose or damaged connections on the circuit board. Firmware Updates: If applicable, update the firmware for optimal performance. Testing After Repair Functional Testing: Run the UPS to ensure it operates correctly. Load Testing: Test under load conditions to verify performance and capacity. Battery Discharge Test: Simulate a power outage to ensure the UPS provides backup power as expected. Final Inspection Safety Checks: Verify that all repairs meet safety standards. Documentation: Record all repairs, parts replaced, and any other relevant information for future reference. Maintenance Tips Regular Testing: Conduct periodic self-tests and inspections to identify potential issues early. Battery Maintenance: Keep battery terminals clean and ensure connections are tight. Cooling: Ensure proper ventilation around the UPS to prevent overheating. Environment: Keep the UPS in a controlled environment, away from moisture and extreme temperatures. When to Seek Professional Help If issues are complex or beyond basic troubleshooting, consult a professional service. Use authorized Vertiv service centers for repairs to ensure quality and warranty compliance. Conclusion Repairing a Vertiv 1 kVA UPS requires careful diagnosis and knowledge of electrical systems. Regular maintenance can help prevent many common issues, ensuring reliable performance. For more complicated repairs, seeking professional help is recommended to ensure safety and effectiveness.

Send Message
product image
ALL TYPES OF UPS REPAIR

UPS (Uninterruptible Power Supply) repair typically involves diagnosing and fixing issues related to power failures, battery problems, or malfunctioning components. Here are some common repair tasks: Battery Replacement: Batteries in UPS units degrade over time and may need replacing. This is one of the most common repairs. Power Supply Issues: Problems with the internal power supply circuit or malfunctioning capacitors can cause a UPS to fail to charge or provide backup power. Overheating Issues: Dust buildup or fan failure can cause the unit to overheat, requiring cleaning or fan replacement. Inverter and Charger Problems: If the UPS isn't converting DC to AC power properly, it could be an inverter problem. Similarly, charger failures could stop the battery from charging. Internal Component Replacement: This may involve replacing transformers, fuses, or circuit boards that have failed.

Send Message
product image
VERTIV UPS

The Liebert APM is a modular, scalable, and flexible Uninterruptible Power Supply (UPS) system from Vertiv (formerly Emerson Network Power). It's designed to provide reliable power protection for a wide range of applications, including IT, industrial, healthcare, and telecommunication environments. The Liebert APM series comes in various power ratings, with the range you mentioned being 30 kW - 300 kW, as well as the smaller 1 to 25 kVA units, offering high flexibility for different power requirements. Key Features of the Liebert APM Series: Modular Design: One of the standout features of the Liebert APM UPS system is its modular design. This allows users to scale the system based on their current needs and future expansion. The modular units can be added incrementally, making it highly adaptable. This modular approach allows for easy maintenance and upgrades without having to replace the entire UPS unit. High Efficiency: The Liebert APM delivers high efficiency, typically achieving up to 95% or more under normal operating conditions. This efficiency helps reduce operational costs and energy consumption. It also features Eco-mode operation, which optimizes energy savings when operating in non-critical situations without compromising protection. Compact and Flexible: Despite its modular nature, the Liebert APM system has a compact design that fits easily into most data centers and industrial setups, where space can often be at a premium. It can be configured for 1-phase or 3-phase power supply, offering flexibility for different types of loads and systems. Scalable Power: The Liebert APM is available in a range from 1 kVA to 300 kVA, which makes it suitable for small server rooms to large data centers. The system allows for easy scalability by adding additional power modules as needed to meet growing demands. Flexible Battery Configurations: The UPS system supports a variety of battery configurations, allowing for customization based on your runtime requirements. You can select from different battery types, including VRLA (Valve-Regulated Lead-Acid) and lithium-ion batteries. Advanced Monitoring and Management: Liebert APM comes with Intelligent Monitoring that provides real-time data on the UPS’s performance, such as input/output voltage, battery status, and efficiency. It supports both local and remote monitoring, ensuring that technicians can be alerted to issues before they become critical problems. The system can be integrated with network management systems (NMS) for centralized control across multiple units. Dual Input Capability: Some models of the Liebert APM offer dual input power sources, providing redundancy for critical applications. This feature ensures that the system remains operational even if one power input fails. Fast Response Time: The Liebert APM offers a fast transfer time (typically in the milliseconds), ensuring that sensitive equipment is protected even during brief power outages or voltage fluctuations. Applications: Data Centers: Providing reliable, scalable power protection for server rooms and IT infrastructure. Industrial: Protecting critical manufacturing equipment and automated systems from power interruptions. Healthcare: Ensuring medical equipment, including imaging devices, lab instruments, and patient monitoring systems, remain operational during power outages. Telecommunications: Keeping communication systems up and running to ensure continuous operation of vital network infrastructure. Benefits: Scalability: The ability to scale up or down as required, which is a huge benefit for growing businesses or changing environments. Reduced Total Cost of Ownership (TCO): With high efficiency and modularity, the Liebert APM reduces energy consumption and minimizes the cost of maintenance. Reliability: Known for providing excellent protection against power issues, including surges, spikes, and outages. Customization: Supports different configurations and battery options to meet specific needs, offering flexibility across various industries. Models & Power Ratings: Small Power Ratings: For smaller environments or edge computing setups, Liebert APM models ranging from 1 kVA to 25 kVA offer robust protection without being overly complex. Large Power Ratings: For larger industrial or data center applications, the 30 kW to 300 kW versions provide scalable power protection to ensure high availability for critical operations.

Send Message
product image
2kva ups repair

Vertiv (formerly Emerson Network Power) is a leading provider of uninterruptible power supply (UPS) systems, power management, and thermal management solutions. Vertiv\'s UPS systems, including models with 2kVA capacity, are widely used in homes, offices, and small businesses to provide reliable power backup during grid power failures or fluctuations. When a Vertiv 2kVA UPS encounters issues, it may require repair, either due to a malfunctioning component or wear-and-tear over time. Here’s an overview of common problems, repair procedures, and troubleshooting steps for Vertiv 2kVA UPS repair: Common Problems in Vertiv 2kVA UPS UPS Not Turning On Possible Causes: Faulty battery or dead battery Blown fuse or circuit breaker Power supply input issue (fuse or switch) Repair Action: Check and replace the battery if necessary. Inspect the fuse or circuit breaker and replace if blown. Verify the input power connections. Frequent Switching to Battery Mode Possible Causes: Input power fluctuations or poor power quality Battery failure or degraded battery capacity UPS in bypass mode due to an internal fault Repair Action: Test the incoming voltage using a multimeter to ensure it’s within the UPS input range. Check the battery voltage; if it\'s low, consider replacing the battery. Check if the UPS is in bypass mode and reset it if necessary. UPS Not Charging the Battery Possible Causes: Faulty charger circuit Bad battery connections or corroded terminals Defective charging board Repair Action: Inspect battery terminals for corrosion and clean them. Test the charging voltage and check for proper charging circuit operation. If the charger board is defective, it may need to be replaced. Overheating and Shutdown Possible Causes: Overloaded UPS (too many devices connected) Poor ventilation or blocked air vents Faulty cooling fan Repair Action: Disconnect unnecessary devices and reduce the load. Ensure the UPS has proper ventilation and airflow around it. Check the fan for functionality; replace if faulty. UPS Producing Beeping Sound Possible Causes: Low battery Overload condition Internal fault or failure of components Repair Action: Replace or recharge the battery if it’s low. Disconnect some load if the UPS is overloaded. If the beeping persists, perform a deeper diagnostic of internal components (inverter, rectifier, etc.). Output Voltage Issues (Distorted or Incorrect Voltage) Possible Causes: Faulty inverter or rectifier circuit Problem with the output transformer Faulty output relay or PCB Repair Action: Measure the output voltage and compare it with the rated output. Inspect the inverter and rectifier circuits for any faults or blown components. Check the PCB for signs of damage or burnt components.

Send Message
product image
4 kva ups

The Luminous Cruze+ 4kVA is a high-performance online UPS that provides uninterrupted power for residential, commercial, and IT applications. Being an online UPS, it offers continuous, stable power with zero transfer time, making it ideal for sensitive equipment such as computers, servers, medical devices, and industrial systems. Key Features of Luminous Cruze+ 4kVA UPS Online Double-Conversion Technology: The Cruze+ 4kVA uses true online double-conversion technology, which ensures that your devices get clean, continuous, and regulated power without interruptions. In case of any fluctuations in the input voltage, the UPS immediately corrects it and ensures stable output voltage. Pure Sine Wave Output: The UPS provides pure sine wave output, which is ideal for sensitive devices, as it ensures minimal distortion and avoids any damage to electronic equipment, unlike square wave UPS systems that can harm certain types of equipment. High Efficiency: With a high conversion efficiency, the Cruze+ 4kVA reduces energy consumption and operational costs. This makes it not only a reliable backup solution but also energy-efficient. Wide Input Voltage Range: The Cruze+ UPS is designed to handle a wide input voltage range, which ensures that the system performs well even in areas with frequent voltage fluctuations, thereby reducing wear and tear on both the UPS and connected devices. Long Battery Life: Equipped with advanced battery management features, this UPS helps in optimizing the battery life, offering extended service periods even with frequent use. LCD/LED Display: The LCD display shows real-time status of the UPS, including input/output voltage, battery charge status, load percentage, and any faults. The LED indicators make it easier to monitor and understand the operational status at a glance. Battery Charging: The Cruze+ 4kVA UPS can handle multiple battery types, including lead-acid and VRLA batteries. It is equipped with an intelligent charging system that ensures batteries are charged efficiently without overcharging. Overload and Short Circuit Protection: Provides overload protection and short-circuit protection, ensuring that the system is safe from potential damage during power surges or faults. Battery Bank Options: The Cruze+ 4kVA is typically paired with a separate battery bank that provides the backup power. This can include Exide tubular batteries or Luminous batteries for optimal performance. Applications Residential: For powering sensitive equipment like computers, medical devices, and other electronics. Commercial: Protects servers, networking equipment, and office devices. Industrial: Suitable for critical industrial machines, automation systems, and control panels. Technical Specifications Capacity: 4kVA (4000 VA) Input Voltage: 140V - 300V (Wide input voltage range) Output Voltage: 220V / 230V (Pure sine wave) Output Frequency: 50 Hz ± 0.2 Hz Battery Charging Current: Adjustable (Typically 5-10A) Battery Type: Compatible with VRLA, Lead-Acid, and Tubular Batteries Backup Time: Depends on the battery capacity (typically, it can provide backup for 2-4 hours depending on the load and battery bank size). Dimensions (LxWxH): 465mm x 310mm x 115mm Weight: Around 15-18 kg (excluding battery) Warranty: 2 years on the UPS (can vary based on the model or region)

Send Message
product image
20 KVA UPS

The Vertiv Liebert GXT5-20KMVRT11UXLN is a 20kVA (20000VA) rack/tower UPS from the Liebert GXT5 series. The GXT5 series provides high-performance, reliable power protection for critical equipment in IT environments such as data centers, server rooms, and telecommunications. The Liebert GXT5-20KMVRT11UXLN model is specifically designed to deliver high availability, efficient energy management, and flexible configurations (tower or rackmount). Here\'s a detailed breakdown of the Vertiv Liebert GXT5-20KMVRT11UXLN UPS: Key Features of the Vertiv Liebert GXT5-20KMVRT11UXLN: 1. Power Rating and Capacity: Power Rating: 20kVA / 20000VA Output Power: 16000W (16kW) at 208V (depending on load conditions) This provides robust protection for high-density IT loads, such as servers, network switches, telecom systems, and critical infrastructure. 2. Voltage Configuration: Input Voltage: 208V (for 3-phase input) The GXT5 can also be configured to operate at 120V AC (single-phase) when needed, making it flexible for different types of equipment and power requirements. 3. Topology: On-Line Double-Conversion: The GXT5 series uses double-conversion (On-Line) topology, providing the highest level of protection. This topology ensures that the UPS continuously filters and conditions the input power and provides a pure sinewave output to sensitive loads, completely isolating the load from power disturbances. Zero transfer time from utility power to battery power ensures no downtime for connected equipment. 4. Waveform Type: Pure Sinewave Output: The UPS produces a clean, pure sinewave output which is essential for powering sensitive IT equipment without distortion or interference. 5. Battery Type and Runtime: Battery Type: Typically uses Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) batteries, which require little maintenance and are commonly used in high-performance UPS systems. External Battery Support: The Liebert GXT5-20KMVRT11UXLN supports external battery packs (available separately) to extend runtime for longer periods, making it ideal for power-hungry or mission-critical applications. Charging Time: Typically, it takes about 4-6 hours to recharge the batteries to 90% capacity. 6. Runtime (Backup Time): The battery backup time will vary depending on the load. Here are some estimates: At 50% load (10kVA/10000W): Backup time could range between 15 to 25 minutes. At full load (20kVA/16000W): Backup time would be much shorter, around 5-10 minutes depending on configuration and battery capacity. Extended runtime can be achieved with additional external battery cabinets. 7. Cooling: Fan-assisted cooling ensures optimal temperature management during operation. The UPS is designed to operate efficiently even in environments with higher ambient temperatures. 8. Form Factor: Rackmount and Tower: The Liebert GXT5-20KMVRT11UXLN offers a flexible design, enabling it to be deployed as either a tower or a rackmount UPS. Rackmount form factor: 3U (for the rack version), designed for 19-inch rack installations. The rackmount option allows easy integration into standard server racks or data center environments. 9. Energy Efficiency and Certifications: Energy Star Certification: The Liebert GXT5 is Energy Star certified, meaning it meets high-efficiency standards and minimizes energy consumption during operation. It also has low total cost of ownership (TCO), thanks to its energy-efficient operation. High Efficiency Mode (Eco Mode): The UPS features an eco mode for high-efficiency operation during normal conditions, further reducing energy consumption when conditions permit. 10. Interfaces and Monitoring: LCD Display: The UPS comes with an LCD display that provides real-time information on key parameters such as input/output voltage, battery charge, load levels, and alarm status. Connectivity: USB, Serial, and Network Ports: The GXT5-20KMVRT11UXLN has USB and serial communication ports for local management and monitoring. SNMP Slot: It comes with an optional SNMP card for remote monitoring, allowing you to manage the UPS from anywhere on the network. Dry Contact Interface: Available for integration with building management or alert systems. 11. Advanced Features: Automatic Transfer Switch (ATS): The Liebert GXT5 can support an optional ATS for automatic switching between the utility power and the UPS in the event of a failure, ensuring seamless power continuity. Overload and Short-Circuit Protection: Protects the UPS and connected loads in case of an overload or short circuit by gracefully shutting down the system or providing alarms. Smart Battery Management: The system features battery monitoring to optimize charging cycles and extend the life of the battery bank. Battery health diagnostics help predict and prevent potential failures. Audible Alarms: Provides alerts for low battery, overload, power failure, and other system faults, ensuring that you’re always aware of the UPS condition.

Send Message
product image
6 KVA UPS

The Vertiv 6kVA UPS models are available in both the SB (Standby) and LB (Line-Interactive) series, as well as other more advanced series, such as the On-Line (Double Conversion) series, which are designed for higher power loads and more demanding applications. Below is a breakdown of the 6kVA UPS options from Vertiv, highlighting the SB, LB, and other potential variants, including their key features, specifications, and ideal use cases. Vertiv 6kVA LB (Line-Interactive) Series UPS The LB Series for 6kVA is more advanced than the SB Series, using a Line-Interactive topology that corrects voltage fluctuations without switching to battery power. This is ideal for environments where power stability is critical, and provides more reliable protection for sensitive equipment. Key Features: Topology: Line-Interactive Power Rating: 6kVA / 6000VA Output Power: 4200W - 5400W (depending on model) Input Voltage: 140V - 300V (wider input range than SB series) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (or Pure Sinewave, depending on model) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: 12V, 18Ah, 24Ah, or higher (depending on model) Charging Time: 4-6 hours for full charge Backup Time (Runtime): 10-30 minutes depending on load (e.g., 50-70% load) Cooling: Fan-assisted cooling for high-efficiency operation Interfaces: USB/Serial ports (with optional software for remote monitoring and automatic shutdown) Form Factor: Tower or Rackmount (depending on specific model) Additional Features: Automatic Voltage Regulation (AVR): Helps correct voltage fluctuations (e.g., brownouts or surges) without using battery power Cold Start: Can be turned on without mains power (useful during power failures) LCD/LED Display (on some models): Real-time monitoring of UPS status, battery level, load capacity, etc. Overload, short-circuit, and low-battery protection Smart battery management to extend battery life and improve performance Audible alarms for low battery, overload, and fault events Advanced monitoring and remote management (via optional software) Ideal Use Case: Small-to-medium-sized servers, network equipment, and critical business infrastructure Medical equipment, point-of-sale (POS) systems, and sensitive electronics requiring stable power quality IT infrastructure in small businesses needing both battery backup and protection against power fluctuations Vertiv 6kVA On-Line (Double Conversion) Series UPS The On-Line (Double Conversion) series is the most robust and efficient series, providing true double-conversion power protection. This topology is designed to offer continuous clean and stable power to sensitive equipment, protecting it from all power disturbances including blackouts, brownouts, and voltage surges. Key Features: Topology: On-Line (Double Conversion) Power Rating: 6kVA / 6000VA Output Power: 4800W - 5400W (depending on the model) Input Voltage: 110V - 300V (wide input range) Output Voltage: 230V ± 2% (pure sinewave output) Waveform Type: Pure Sinewave Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 18Ah, or 24Ah, with external battery options for longer runtimes Charging Time: 4-6 hours for full charge Backup Time (Runtime): 20-40 minutes depending on load (e.g., 50-60% load) Cooling: Advanced fan-assisted cooling with efficient heat dissipation Interfaces: USB/Serial ports, RS-232, SNMP for remote monitoring and management Form Factor: Tower or Rackmount Additional Features: Double Conversion: Provides continuous, clean power from the UPS’s inverter, ensuring zero transfer time during power disturbances High Efficiency Mode: Switches to energy-efficient operation during stable power conditions while ensuring seamless transition to double conversion during power failure LCD/LED Display: Provides real-time status of the UPS, battery health, load capacity, etc. Remote Monitoring: Integrated SNMP or optional software for proactive monitoring and automated shutdown Overload and short-circuit protection Extended Battery Options: External battery packs for longer runtime in high-demand applications

Send Message