Faridabad
+918076792323

'short circuit proof inverter'

Items tagged with 'short circuit proof inverter'

product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Luminous Ups

The Luminous LD30KH-PRO is a high-performance Inverter designed to provide reliable backup power for homes, offices, and small commercial setups. It is a part of Luminous' Pure Sine Wave Inverter series, offering high efficiency and stable power supply to sensitive equipment like computers, refrigerators, air conditioners, and other appliances. Here are the key features and specifications of the Luminous LD30KH-PRO: Key Features: Power Capacity: 30 kVA (Kilovolt-Ampere) – It is designed to support large power loads, making it suitable for medium to large residential, commercial, or industrial applications. Pure Sine Wave Output: Provides clean and stable output voltage, ensuring that sensitive equipment (like computers, air conditioners, and medical equipment) operates without issues, such as noise or voltage fluctuations. High Efficiency: The inverter operates with high efficiency, which reduces power loss and ensures that more of the battery's energy is used to power connected appliances. Advanced Microprocessor Technology: The inverter uses a microprocessor-based design to ensure high performance, protection, and reliability. It optimizes charging and discharging cycles, as well as load management. User-Friendly LCD Display: It comes with an intuitive LCD display that shows important information such as battery status, power usage, input and output voltage, and fault conditions. This helps users easily monitor and manage the system. Wide Input Voltage Range: The inverter operates with a wide input voltage range, which helps it perform well under varying input conditions. This feature helps protect connected equipment from power surges and fluctuations. Multiple Protection Mechanisms: Built-in protection features include overload protection, short-circuit protection, deep discharge protection, and battery reverse polarity protection, which ensures the safety of the connected equipment. Battery Compatibility: The Luminous LD30KH-PRO is compatible with both lead-acid and lithium-ion batteries, giving users flexibility depending on their preferences for battery technology. Smart Battery Management: The inverter comes with intelligent battery management to optimize battery performance, extending their lifespan and ensuring safe charging and discharging cycles. Compact and Reliable Design: Designed with a compact form factor and a durable build, the inverter is ideal for both indoor and outdoor installations and can be used for both backup power and off-grid applications. Applications: Residential Homes – For providing backup power for large appliances like air conditioners, refrigerators, lighting, and electronics. Small and Medium Businesses – For ensuring uninterrupted power supply to computers, servers, and other essential equipment. Commercial Use – Ideal for large offices, small industries, and workshops. Rural/Off-Grid Areas – Can be used in places with frequent power outages or no access to the grid, providing a reliable power solution. Specifications Summary: Rated Capacity: 30 kVA Output Type: Pure Sine Wave Input Voltage: 120V – 300V (depending on model) Charging Current: Adjustable (depends on load) Display: LCD with detailed status updates Battery Compatibility: Compatible with lead-acid and lithium-ion batteries

Send Message
product image
AMARON QUANTA TUBULAR BATTERY

The Amaron C10 150AH Quanta Tubular Battery is designed for inverter applications and features the following specifications: Capacity: 150 Ah Voltage: 12 V Type: Tubular Protection: Over temperature, deep discharge, and short circuit Backup Time: Approximately 2 hours This battery is built for high performance and reliability, making it suitable for various power backup needs. Key Features of Amaron C10 150AH Quanta Tubular Battery Construction: Extra thick plates for enhanced longevity Maintenance: Low maintenance requirements due to special alloy composition Charge Acceptance: Excellent charge acceptance, ideal for frequent power cuts Level Indicators: Easy maintenance with built-in level indicators Power Cut Resilience: Designed to withstand frequent and prolonged power outages Specifications Brand: Amaron Model: C10 Voltage: 12V DC Capacity: 150Ah Type of Battery: Tall Tubular Inverter Compatibility: Supports all brands and types of inverters Factory Charged: Yes Warranty: 48 months (36 months replacement and 12 months pro-rata) This battery is an excellent choice for users looking for a reliable and efficient power backup solution, particularly in areas with frequent power interruptions.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
6 KVA UPS

The Vertiv 6kVA UPS models are available in both the SB (Standby) and LB (Line-Interactive) series, as well as other more advanced series, such as the On-Line (Double Conversion) series, which are designed for higher power loads and more demanding applications. Below is a breakdown of the 6kVA UPS options from Vertiv, highlighting the SB, LB, and other potential variants, including their key features, specifications, and ideal use cases. Vertiv 6kVA LB (Line-Interactive) Series UPS The LB Series for 6kVA is more advanced than the SB Series, using a Line-Interactive topology that corrects voltage fluctuations without switching to battery power. This is ideal for environments where power stability is critical, and provides more reliable protection for sensitive equipment. Key Features: Topology: Line-Interactive Power Rating: 6kVA / 6000VA Output Power: 4200W - 5400W (depending on model) Input Voltage: 140V - 300V (wider input range than SB series) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (or Pure Sinewave, depending on model) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: 12V, 18Ah, 24Ah, or higher (depending on model) Charging Time: 4-6 hours for full charge Backup Time (Runtime): 10-30 minutes depending on load (e.g., 50-70% load) Cooling: Fan-assisted cooling for high-efficiency operation Interfaces: USB/Serial ports (with optional software for remote monitoring and automatic shutdown) Form Factor: Tower or Rackmount (depending on specific model) Additional Features: Automatic Voltage Regulation (AVR): Helps correct voltage fluctuations (e.g., brownouts or surges) without using battery power Cold Start: Can be turned on without mains power (useful during power failures) LCD/LED Display (on some models): Real-time monitoring of UPS status, battery level, load capacity, etc. Overload, short-circuit, and low-battery protection Smart battery management to extend battery life and improve performance Audible alarms for low battery, overload, and fault events Advanced monitoring and remote management (via optional software) Ideal Use Case: Small-to-medium-sized servers, network equipment, and critical business infrastructure Medical equipment, point-of-sale (POS) systems, and sensitive electronics requiring stable power quality IT infrastructure in small businesses needing both battery backup and protection against power fluctuations Vertiv 6kVA On-Line (Double Conversion) Series UPS The On-Line (Double Conversion) series is the most robust and efficient series, providing true double-conversion power protection. This topology is designed to offer continuous clean and stable power to sensitive equipment, protecting it from all power disturbances including blackouts, brownouts, and voltage surges. Key Features: Topology: On-Line (Double Conversion) Power Rating: 6kVA / 6000VA Output Power: 4800W - 5400W (depending on the model) Input Voltage: 110V - 300V (wide input range) Output Voltage: 230V ± 2% (pure sinewave output) Waveform Type: Pure Sinewave Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 18Ah, or 24Ah, with external battery options for longer runtimes Charging Time: 4-6 hours for full charge Backup Time (Runtime): 20-40 minutes depending on load (e.g., 50-60% load) Cooling: Advanced fan-assisted cooling with efficient heat dissipation Interfaces: USB/Serial ports, RS-232, SNMP for remote monitoring and management Form Factor: Tower or Rackmount Additional Features: Double Conversion: Provides continuous, clean power from the UPS’s inverter, ensuring zero transfer time during power disturbances High Efficiency Mode: Switches to energy-efficient operation during stable power conditions while ensuring seamless transition to double conversion during power failure LCD/LED Display: Provides real-time status of the UPS, battery health, load capacity, etc. Remote Monitoring: Integrated SNMP or optional software for proactive monitoring and automated shutdown Overload and short-circuit protection Extended Battery Options: External battery packs for longer runtime in high-demand applications

Send Message
product image
battery

The Amaron Quanta 12V 9Ah battery is a type of lead-acid battery commonly used in various applications such as uninterruptible power supplies (UPS), electric vehicles, and other equipment requiring reliable power storage. Here are some key details about the Amaron Quanta 12V 9Ah battery: Specifications: Voltage: 12 volts Capacity: 9 ampere-hours (Ah) Type: Lead-acid battery (typically VRLA - Valve Regulated Lead Acid) Dimensions: Varies by manufacturer, but generally around 151mm x 65mm x 94mm (L x W x H) Weight: Approximately 3.5 to 4 kg, depending on the specific model and manufacturer. Terminal Type: Usually comes with F1 or F2 terminals. Operating Temperature Range: Typically between -15°C to +50°C. Cycle Life: Generally rated for about 300-500 cycles depending on depth of discharge and usage conditions. Features: Maintenance-Free: Designed to be maintenance-free, meaning no need for regular water topping. Leak-Proof Design: The VRLA design prevents leakage, making it safer for various applications. High Discharge Rate: Capable of delivering high currents for short periods, which is beneficial for applications requiring burst power. Deep Cycle Capability: Suitable for deep cycle applications, allowing for a deeper discharge without damaging the battery. Durability: Built to withstand harsh conditions and high temperatures, making it suitable for outdoor use. Applications: Uninterruptible Power Supplies (UPS): Provides backup power during outages. Electric Vehicles (EVs): Used in scooters, bikes, and other electric vehicles. Solar Energy Storage: Can be used in solar energy systems for storing power. Emergency Lighting: Powers emergency lighting systems. Telecommunications: Used in communication equipment for backup power. Maintenance Tips: Regular Inspection: Check for any signs of corrosion on terminals and ensure connections are tight. Proper Charging: Use a compatible charger and avoid overcharging to prolong battery life. Storage: Store in a cool, dry place and maintain a charge if not in use for extended periods. Safety Precautions: Avoid Short Circuits: Ensure terminals do not come into contact with conductive materials. Handle with Care: Batteries can be heavy; handle them carefully to avoid injury. Dispose Properly: Follow local regulations for battery disposal or recycling. For the most accurate and specific details, always refer to the manufacturer\'s datasheet or user manual, as specifications may vary slightly between different production batches or models.

Send Message
product image
amc

To provide you with details about UPS (Uninterruptible Power Supply) and batteries, particularly in the context of AMC (Annual Maintenance Contract), here’s a comprehensive overview: UPS (Uninterruptible Power Supply) Purpose: A UPS provides backup power during outages and protects against power surges, ensuring that electronic equipment remains operational. Types of UPS: Offline/Standby UPS: Activates during power failure. Suitable for personal computers and basic electronic equipment. Line-Interactive UPS: Adjusts voltage fluctuations without switching to battery. Good for small to medium-sized businesses. Online UPS: Continuously provides power from the battery, even during normal operation. Ideal for critical applications requiring consistent power. Components: Batteries: Store energy to provide backup. Inverter: Converts DC from batteries to AC for equipment. Charger: Maintains battery charge. Control Circuit: Manages the UPS operations. Batteries Types Used in UPS: Lead-Acid Batteries: Common in UPS systems. Cost-effective, but heavier and have a shorter lifespan. Lithium-Ion Batteries: Increasingly popular due to longer life and lower weight. More expensive but offer better efficiency. Annual Maintenance Contract (AMC) Purpose of AMC: An AMC ensures regular maintenance, reducing the risk of system failures and prolonging the lifespan of the UPS and batteries. Key Components of AMC: Regular Inspections: Scheduled checks to assess the condition of UPS and batteries. Preventive Maintenance: Cleaning, tightening connections, and replacing worn-out parts. Emergency Support: Availability of technical support in case of a failure. Replacement Services: Agreement on the replacement of batteries and components when necessary. Performance Monitoring: Tracking the UPS performance metrics to ensure efficiency. Choosing an AMC Provider Considerations: Reputation: Look for providers with good reviews and experience. Service Level Agreement (SLA): Ensure clear terms regarding response times and services offered. Expertise: Check for qualified technicians with experience in your specific UPS model. Cost: Compare costs while considering the level of service provided. Conclusion An AMC for your UPS system is crucial for maintaining reliability and performance, especially for critical operations. Regular maintenance helps prevent unexpected downtime and extends the life of both the UPS and its batteries. If you need specific recommendations or details about AMC providers in your area, let me know!

Send Message
product image
Battery

Amaron Short Tubular Batteries are a specific type of lead-acid battery designed primarily for use in inverter applications, particularly in regions with frequent power outages. These batteries are known for their durability, long life, and ability to handle deep discharge cycles. Below are the key details and specifications for Amaron Short Tubular Batteries: General Features: Design: Short tubular design allows for better space utilization and easier installation in various setups. Maintenance-Free: Many models are designed to be low-maintenance, requiring minimal attention during their lifespan. Deep Cycle Capability: Specifically engineered to handle deep discharges, making them ideal for inverter applications. Long Life: Known for their longevity, often lasting longer than conventional flat plate batteries. High Efficiency: Offers better charge acceptance and discharge performance, making them suitable for high-demand applications. Corrosion Resistance: Designed with materials that resist corrosion, enhancing the battery's lifespan. Specifications: While specific specifications can vary depending on the model, here are some common specifications for Amaron Short Tubular Batteries: Voltage: 12V Capacity: Typically ranges from 100 Ah to 220 Ah, depending on the model. Dimensions: Varies by model; common sizes include: 100 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) 150 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) 200 Ah: Approximately 30 cm (L) x 17 cm (W) x 22 cm (H) Weight: Generally ranges from 30 kg to 60 kg depending on capacity. Applications: Inverter Systems: Primarily used in home inverter systems for power backup. Solar Applications: Can also be used in solar power systems for energy storage. Commercial Use: Suitable for small businesses requiring reliable power backup solutions. Warranty: Amaron Short Tubular Batteries typically come with a warranty ranging from 24 to 36 months, depending on the specific model. Maintenance Tips: Water Level Check: If the battery is not maintenance-free, periodically check the electrolyte level and top up with distilled water if necessary. Terminal Cleaning: Regularly clean the battery terminals to prevent corrosion. Secure Installation: Ensure that the battery is securely mounted to prevent movement and damage. Environmental Considerations: Lead-acid batteries must be disposed of properly to prevent environmental harm. Many retailers offer recycling programs for old batteries. Conclusion: Amaron Short Tubular Batteries are a reliable choice for those needing a robust power backup solution, especially in areas with frequent power interruptions. For specific models and their detailed specifications, it is advisable to consult the manufacturer's catalog or speak with a retailer.

Send Message
product image
Amaron Quanta Batteries In Baghanki Manesar

Amaron Quanta batteries are known for their reliability and performance, particularly in applications like UPS systems, solar power setups, and backup power. Here’s an overview of the different types and details of Amaron Quanta batteries: Key Features: Sealed Maintenance Free (SMF): No need for water topping or maintenance. Long Service Life: Designed for extended use and durability. High Performance: Capable of handling high discharge rates. Deep Cycle Capability: Suitable for applications requiring frequent deep discharges. Types of Amaron Quanta Batteries: Amaron Quanta 12V 7Ah Dimensions: Approximately 151 x 65 x 94 mm Weight: About 2.5 kg Applications: UPS, alarm systems, portable electronics. Amaron Quanta 12V 9Ah Dimensions: Approximately 150 x 65 x 95 mm Weight: About 3.0 kg Applications: UPS, small power tools, and backup lighting. Amaron Quanta 12V 18Ah Dimensions: Approximately 181 x 77 x 167 mm Weight: Around 5.5 kg Applications: UPS, solar energy systems, and telecommunications. Amaron Quanta 12V 26Ah Dimensions: Approximately 166 x 175 x 125 mm Weight: About 7.0 kg Applications: Larger UPS systems, solar inverters, and backup power systems. Amaron Quanta 12V 42Ah Dimensions: Approximately 198 x 165 x 170 mm Weight: About 12.5 kg Applications: High-capacity UPS systems, solar power systems, and security systems. Amaron Quanta 12V 65Ah Dimensions: Approximately 350 x 167 x 175 mm Weight: Around 19.0 kg Applications: Heavy-duty UPS, large solar installations, and industrial applications. Charging Recommendations: Charging Voltage: Typically between 14.4 to 15.0 volts. Charging Current: Should not exceed specified rates (e.g., for a 7Ah battery, keep under 1.5A; for a 42Ah, under 6A). Storage and Maintenance: Store in a cool, dry place. Keep the battery fully charged if not in use for long periods. Regularly inspect for physical damage or signs of wear. Safety Precautions: Avoid short-circuiting terminals. Handle with care to prevent damage. Follow manufacturer guidelines for safe usage. For precise specifications and any additional models, it’s advisable to check the official Amaron website or product datasheets

Send Message

Still searching for
short circuit proof inverter?