Faridabad
+918076792323

'ups bx600c in 600va'

Items tagged with 'ups bx600c in 600va'

product image
UPS ( Uninterrupted Power Supplies)

UPS ( Uninterrupted Power Supplies) An uninterruptible power supply or uninterruptible power source (UPS) is an electrical apparatus that provides emergency power to a load when the input power source or mains power fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery run-time of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment. It is a type of continual power system. Features of UPS Systems: Line Interactive Range in 600VA and 2000VA with minimal battery backup. We have an online range of UPSs in 1,2 and 3 kVA category both with an internal battery backup of 10 minutes and with a longer battery backup of up to 4 hours. We offer a mini range of UPSs of capacities 6,10 and 20 kVA with options of internal isolation transformers both in single-phase and three-phase options. We have an ITA series of Hitech UPS systems in the range of 6 to 40 kVA. Hiplulse U series of UPS range with internal isolation transformers essentially meant for industrial applications.

Send Message
product image
Luminous Ups

The Luminous LD30KH-PRO is a high-performance Inverter designed to provide reliable backup power for homes, offices, and small commercial setups. It is a part of Luminous' Pure Sine Wave Inverter series, offering high efficiency and stable power supply to sensitive equipment like computers, refrigerators, air conditioners, and other appliances. Here are the key features and specifications of the Luminous LD30KH-PRO: Key Features: Power Capacity: 30 kVA (Kilovolt-Ampere) – It is designed to support large power loads, making it suitable for medium to large residential, commercial, or industrial applications. Pure Sine Wave Output: Provides clean and stable output voltage, ensuring that sensitive equipment (like computers, air conditioners, and medical equipment) operates without issues, such as noise or voltage fluctuations. High Efficiency: The inverter operates with high efficiency, which reduces power loss and ensures that more of the battery's energy is used to power connected appliances. Advanced Microprocessor Technology: The inverter uses a microprocessor-based design to ensure high performance, protection, and reliability. It optimizes charging and discharging cycles, as well as load management. User-Friendly LCD Display: It comes with an intuitive LCD display that shows important information such as battery status, power usage, input and output voltage, and fault conditions. This helps users easily monitor and manage the system. Wide Input Voltage Range: The inverter operates with a wide input voltage range, which helps it perform well under varying input conditions. This feature helps protect connected equipment from power surges and fluctuations. Multiple Protection Mechanisms: Built-in protection features include overload protection, short-circuit protection, deep discharge protection, and battery reverse polarity protection, which ensures the safety of the connected equipment. Battery Compatibility: The Luminous LD30KH-PRO is compatible with both lead-acid and lithium-ion batteries, giving users flexibility depending on their preferences for battery technology. Smart Battery Management: The inverter comes with intelligent battery management to optimize battery performance, extending their lifespan and ensuring safe charging and discharging cycles. Compact and Reliable Design: Designed with a compact form factor and a durable build, the inverter is ideal for both indoor and outdoor installations and can be used for both backup power and off-grid applications. Applications: Residential Homes – For providing backup power for large appliances like air conditioners, refrigerators, lighting, and electronics. Small and Medium Businesses – For ensuring uninterrupted power supply to computers, servers, and other essential equipment. Commercial Use – Ideal for large offices, small industries, and workshops. Rural/Off-Grid Areas – Can be used in places with frequent power outages or no access to the grid, providing a reliable power solution. Specifications Summary: Rated Capacity: 30 kVA Output Type: Pure Sine Wave Input Voltage: 120V – 300V (depending on model) Charging Current: Adjustable (depends on load) Display: LCD with detailed status updates Battery Compatibility: Compatible with lead-acid and lithium-ion batteries

Send Message
product image
Emerson 3-Phase Ups In Manesar

Emerson 3-Phase UPS (Uninterruptible Power Supply) systems are high-quality, reliable power backup solutions typically used in industrial, commercial, and critical infrastructure applications. These systems are designed to provide uninterrupted power to sensitive equipment, preventing downtime due to power interruptions, voltage fluctuations, or other electrical issues. Key Features of Emerson 3-Phase UPS: Power Capacity: 3-Phase UPS systems come in a wide range of power capacities, generally from 10 kVA to 800 kVA or even higher, depending on the model. Suitable for medium to large-scale facilities like data centers, hospitals, manufacturing plants, and office buildings. Technology: Double Conversion Online Technology: Emerson’s 3-phase UPS systems typically use online double conversion technology, meaning that the inverter constantly supplies clean, regulated power to the load while the battery is charging. Efficiency: High-efficiency models (up to 96% or more) reduce energy consumption and operating costs. Battery Management: Integrated advanced battery management for monitoring health, charge, and backup times. High Availability: Designed to provide reliable power for mission-critical applications. Hot Swappable Batteries: In some models, batteries can be replaced without shutting down the UPS, ensuring uninterrupted power supply. Scalability: Many models allow for modular expansion, meaning you can add additional capacity as needed. Input/Output Voltage: Input Voltage: Common input voltages are 380V, 400V, and 415V (3-phase). Output Voltage: Typically 208V, 220V, 230V, or 400V for 3-phase systems, depending on the regional power grid standards. Power Factor: Emerson UPS systems usually have a high power factor of 0.9 or higher, improving efficiency. Advanced Features: LCD/LED Display: Provides real-time data on UPS status, battery health, load levels, and alarms for easy monitoring. Remote Monitoring: Allows remote access for monitoring via web or SNMP (Simple Network Management Protocol) for real-time alerts and diagnostics. Bypass Capability: If maintenance is required or the UPS is malfunctioning, the system can transfer to bypass mode to avoid downtime. Design and Durability: Compact Design: Many models are designed to be space-efficient without compromising on power or cooling needs. Rack-Mountable or Tower Formats: Depending on the installation space, Emerson offers both tower-style and rack-mounted designs. Thermal Management: These UPS systems typically include advanced cooling systems to maintain efficient operation and prevent overheating. Applications: Data Centers: Ensures uptime for servers and networking equipment. Industrial Equipment: Protects critical machinery and automated systems from power failures. Telecommunications: Keeps communication systems running without interruption. Hospitals: Supports life-saving equipment and systems that require constant power. Commercial Buildings: Ensures backup power for office systems and equipment. Maintenance and Service: Smart Battery Testing: Advanced systems monitor the health of batteries and alert users when maintenance or replacement is required. Serviceable Parts: Emerson provides comprehensive support and service contracts to ensure your UPS remains in optimal condition. Proactive Monitoring: With remote monitoring and diagnostic tools, faults can be detected before they impact operations. Popular Models: Emerson (now part of Vertiv) offers various UPS models under different series, such as: Vertiv Liebert® ITA2: A high-efficiency 3-phase UPS solution for small to medium-sized applications. Vertiv Liebert® EXL S1: A modular UPS system that offers scalability and high availability. Vertiv Liebert® NXL: A large capacity 3-phase UPS designed for data centers and industrial applications. Advantages of Emerson 3-Phase UPS: High Reliability: Ensures critical equipment remains powered during power failures or fluctuations. Advanced Technology: Features like online double conversion, modular design, and remote monitoring provide superior performance and flexibility. Energy Efficiency: Many Emerson UPS systems are highly efficient, reducing operating costs and environmental impact. Scalability: As your power requirements grow, Emerson's modular systems can easily expand to meet increased demand. Conclusion: Emerson 3-Phase UPS systems are excellent solutions for businesses and facilities that require high uptime and reliability. With their advanced features, efficient energy use, and robust design, they provide essential power protection for critical infrastructure. Whether you're in need of a UPS for a small office or a large data center, Emerson offers scalable and reliable power backup systems that ensure uninterrupted operation.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
5kva

The Vertiv Liebert GXT5 5kVA UPS is an online double-conversion uninterruptible power supply designed for critical infrastructure protection. It operates at 5kVA/5kW with user-selectable output voltages of 208V and 120V. This UPS features continuous power conditioning, ensuring that connected equipment is safeguarded against power disturbances and outages. Here are the key details: Key Features Power Rating: 5kVA / 5kW Input/Output Voltage: 208V in / 208V out (also supports 120V out) Power Factor: High power factor (0.9-1.0) allows for more connected loads, optimizing space and cost Design: Tower/rack mountable for flexible installation Remote Monitoring: Equipped with a built-in Vertiv RDU101 communications card for remote monitoring Software Support: Compatible with Vertiv Power Insight software for consolidated monitoring of up to 100 UPS units Runtime Options: Scalable runtime with external battery cabinets for extended backup during outages Certification: ENERGY STAR 2.0 certified for energy efficiency Display: Intuitive gravity-sensing full-color LCD display for easy status monitoring Additional Information Applications: Suitable for both centralized and edge locations, protecting critical equipment in various environments Warranty and Support: On-site service and advanced exchange service options available after remote diagnosis, ensuring quick resolution of issues Conclusion The Vertiv Liebert GXT5 5kVA UPS is a robust solution for ensuring continuous power supply and protection for critical systems, making it ideal for data centers, IT infrastructure, and other sensitive applications.

Send Message
product image
6 kva ups

The Vertiv 6 kVA UPS models, such as the Liebert GXT5 and Liebert GXT MTX+, offer robust power protection for critical equipment. Here are the key specifications and details: Vertiv Liebert GXT5 6 kVA/6 kW Model: Liebert GXT5 Capacity: 6 kVA / 6 kW Input Voltage: 208/120V Output Power Factor: 1.0 (Unity) Form Factor: Rack/Tower Dimensions: Depth: 25.6 inches Rack Height: 4U Weight: Approximately 125.60 lbs Backup/Run Time: Half Load: 9.50 minutes Full Load: 3.50 minutes Transfer Time: 0 ns (no break) Receptacle Type: Hardwired Bypass Switch: Automatic & Manual; Internal Emergency Power OFF: Yes Audible Noise: Less than 55 dBA at 1 meter Vertiv Liebert GXT MTX+ 6 kVA Model: Liebert GXT MTX+ Output Power Factor: 0.8 Input Voltage Range: 110 — 300 Vac Charging Design: 4 Stage Extendable Charging for optimized battery performance Adjustable Battery Charging Current: 1/2/4/6 Amps based on battery capacity Compact Design: Best-in-class online UPS system General Features Type: Online Double Conversion UPS Protection: Protects against outages and all types of power disturbances Applications: Suitable for centralized and edge locations, ideal for critical equipment These UPS systems are designed to ensure reliable power supply and protect sensitive electronic equipment from power disturbances, making them essential for data centers, telecommunications, and other critical applications.

Send Message
product image
S600D UPS

The Liebert S600D 3x1 10/20kVA is a highly efficient, double conversion UPS designed for critical power applications. Here are the key specifications and details: Overview Type: Fully-digital, double conversion UPS. Power Rating - Capacity Options: Available in 10 kVA and 20 kVA models. Input Voltage: 415 VAC. Output Voltage: 230 VAC. Design Features Configuration: 3 Phase Input - 1 Phase Output. Form Factor: Tower model for space efficiency. Weight: 10 kVA model: 158 kg. 20 kVA model: Approximately 200 kg (exact weight may vary). Performance Specifications Efficiency: High efficiency with low input current harmonic distortion (<5%). Power Factor: Unity input power factor for optimal performance. Overload Protection: High overload and short-circuit protection capabilities. Battery and Backup Battery Type: Sealed lead-acid, tubular, or lithium-ion options. Backup Time: Varies based on load; designed for extended backup during outages. Monitoring and Management Display: LCD display and mimic panel for real-time information on UPS status. Intelligent Battery Management: Features temperature-compensated battery charging to enhance battery life. Alarms: Can store alarms in memory for troubleshooting. Applications Suitable for industrial applications, data centers, and critical infrastructure requiring reliable power supply. Ideal for environments where clean and uninterrupted power is essential. Conclusion The Liebert S600D 3x1 UPS series offers robust power protection with advanced features, making it an excellent choice for businesses that demand high reliability and efficiency in their power systems.

Send Message
product image
20kva ups

The Vertiv ITA 20kVA UPS is a robust power protection solution designed for mission-critical applications. Here are the key details: Vertiv ITA 20kVA UPS Overview Type: True online, double conversion, three-phase UPS. **Power Rating - Capacity: 20 kVA / 20 kW. Input Voltage: Configurable for 380/400/415 VAC. Frequency: Operates at 50/60 Hz. Design Features Form Factor: Compact rack-tower design for installation flexibility. Dimensions: Designed to fit in standard server racks or as a standalone unit. Weight: Approximately 200 kg (varies by configuration). Performance Specifications Efficiency: High efficiency with a unity power factor, ensuring maximum power delivery. Output: Provides both three-phase and single-phase output options. Scalability: Can be configured for parallel operation to increase capacity and redundancy. Battery and Backup Battery Type: Typically uses lead-acid batteries, with options for lithium-ion for longer life and reduced maintenance. Backup Time: Varies based on load; designed to provide extended backup for critical systems. Monitoring and Management Display: LCD screen for real-time monitoring of UPS status, battery health, and load levels. Communication: Equipped with SNMP/Web card for remote monitoring and management capabilities. Management Software: Compatible with Vertiv\'s monitoring solutions for enhanced management. Applications Ideal for small computer rooms, network equipment, and data centers requiring reliable power protection. Suitable for industries such as healthcare, finance, and telecommunications where uptime is critical. Conclusion The Vertiv ITA 20kVA UPS is a highly efficient and reliable power protection solution, designed to meet the demands of critical applications with its advanced features and robust performance.

Send Message

Still searching for
ups bx600c in 600va?