Faridabad
+918076792323

'visual indicators'

Items tagged with 'visual indicators'

product image
2 KVA UPS

Vertiv 2kVA UPS SB MODEL & LB MODEL The Vertiv 2kVA UPS models in the SB (Standby) and LB (Line-Interactive) series offer similar features to their 1kVA counterparts, but with higher power ratings to cater to larger or more demanding devices. Here are the general details for each series in the 2kVA range: 1. Vertiv 2kVA SB (Standby) Series UPS The SB Series for 2kVA is a basic UPS solution designed for small office and home office environments where power backup and protection from power surges are required for a range of devices. Key Features: Topology: Standby (Off-line) Power Rating: 2kVA / 2000VA Output Power: 1200W - 1600W (depending on model) Input Voltage: 160V - 280V (wide voltage range) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (approximate sinewave output) Battery Type: Sealed Lead-Acid (SLA) or VRLA (Valve-Regulated Lead-Acid) Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Approximately 4-8 hours for a full charge Backup Time (Runtime): Provides backup for 5-15 minutes depending on the load (e.g., for 60-80% load) Cooling: Fan-assisted cooling for heat dissipation Interfaces: USB or serial ports for monitoring (depending on model) Form Factor: Typically Tower Additional Features: Surge protection Overload and short-circuit protection Low battery, overload, and fault indicators Automatic shutdown feature with optional software Audible alarms for power events (e.g., overload, low battery, fault) Compact design for easier placement in home office or small business environments Ideal Use Case: Home offices and small businesses Workstations, point-of-sale (POS) systems, and network equipment Consumer electronics that need surge protection and limited backup time 2. Vertiv 2kVA LB (Line-Interactive) Series UPS The LB Series for 2kVA is a more robust and efficient option than the Standby series, suitable for more demanding applications. It provides better voltage regulation and a higher level of protection due to the line-interactive topology. Key Features: Topology: Line-Interactive Power Rating: 2kVA / 2000VA Output Power: 1400W - 1800W (varies by model) Input Voltage: 140V - 300V (wider input range than SB series) Output Voltage: 230V ± 10% Waveform Type: Simulated Sinewave (typically) or Pure Sinewave (depending on model) Battery Type: Sealed Lead-Acid (SLA) or VRLA Battery Capacity: Typically 12V, 9Ah or 12Ah (varies by model) Charging Time: Around 4-6 hours to fully charge the battery Backup Time (Runtime): Can provide backup for 10-20 minutes depending on load (typically for a 50-70% load) Form Factor: Tower or Rackmount (depending on model) Interfaces: USB and/or Serial port for monitoring and management (some models support software for auto-shutdown) Additional Features: Automatic Voltage Regulation (AVR) to correct voltage fluctuations Cold Start: Can be turned on without mains power (useful in power failure situations) Overload, short-circuit, and low battery protection LCD or LED display (on some models) for real-time monitoring of UPS status, battery level, load capacity, etc. Enhanced battery management and energy-saving features to extend battery lifespan Audio and visual alerts for power failures, overloads, and battery issues Smart monitoring and management with optional software for power event logging and automatic shutdown Ideal Use Case: Small to medium-sized servers, workstations, and network equipment Sensitive equipment needing more precise power regulation IT infrastructures that require more consistent and reliable power protection Critical devices where frequent voltage fluctuations or outages could damage equipment Conclusion: SB Series (2kVA): The SB Series is a more cost-effective option for users who need basic backup power and surge protection for small office or home use. It is ideal for lower-power devices and non-critical applications where voltage regulation isn't a priority. LB Series (2kVA): The LB Series provides more robust features, such as Automatic Voltage Regulation (AVR), better battery management, and longer runtime. This makes it a better option for users who need more reliable and consistent power, especially in small to medium business environments, servers, or critical systems where power fluctuations are more common.

Send Message
product image
Battery Testing In Sonipat

Battery testing is essential to ensure optimal performance, safety, and longevity. Here are key details: Types of Tests: Voltage Test: Measures the battery's output voltage to check if it meets the specified range. Capacity Test: Assesses how much charge the battery can hold and deliver over time. Load Test: Simulates real-world usage to check how the battery performs under load. Internal Resistance Test: Evaluates the battery's internal resistance, indicating its health. Tools Used: Multimeter, hydrometer (for lead-acid batteries), battery analyzer, and load testers. Frequency: Regular testing is recommended, especially for backup power systems, to prevent unexpected failures. Indicators of a Faulty Battery: Low voltage, poor capacity, high internal resistance, or physical damage like swelling or leakage. Proper battery testing helps in proactive maintenance, ensuring reliability and safety.

Send Message
product image
Powerstack battery Testing

Powerstack batteries, typically used in UPS systems, inverters, and other energy storage applications, require proper testing and maintenance to ensure their efficiency, longevity, and reliability. If you need to perform battery testing on a Powerstack battery, here's a general guide for testing and monitoring its condition: Steps to Test Powerstack Batteries: 1. Visual Inspection Check for Physical Damage: Inspect the battery casing for any cracks, leaks, or bulges. Damaged batteries should be replaced. Clean the Terminals: Ensure the terminals are clean and free from corrosion. If there is any corrosion, clean the terminals with a mixture of baking soda and water. 2. Check Battery Voltage Measure the Open-Circuit Voltage (OCV): Use a digital voltmeter to measure the voltage across the battery terminals when it is not connected to any load. Compare the measured voltage to the battery’s rated voltage. A typical fully charged 12V lead-acid battery should read around 12.6 to 12.8 volts. For a 24V battery, you should see a voltage of around 25.2 to 26.0 volts. Undercharged Battery: If the voltage is significantly lower (e.g., 10.5V or less for a 12V battery), it may indicate that the battery is undercharged or faulty. 3. Load Testing Test under Load: Apply a load to the battery, simulating its normal working conditions. The load can be an inverter or UPS system that draws power from the battery. Monitor the voltage drop under load. The voltage should not drop drastically; otherwise, it may indicate that the battery is aging or weak. DC Discharge Test: If you have access to a battery analyzer or tester, you can perform a discharge test by applying a constant load and measuring the time it takes for the battery to reach a certain voltage cutoff. 4. Battery Charge Test Charge the Battery Fully: Use the manufacturer’s recommended charger to fully charge the battery. Most Powerstack systems will charge to full capacity in 6-12 hours, depending on the charger and battery size. Monitor Charging Parameters: If the battery doesn’t charge properly or takes longer than usual, it might indicate problems with the battery or the charger. End of Charge Voltage: For lead-acid batteries, the end-of-charge voltage should be around 14.4 to 15.0 volts for a 12V battery and 28.8 to 30.0 volts for a 24V battery. 5. Conduct a Specific Gravity Test (for Lead-Acid Batteries) Hydrometer Test: If your Powerstack battery is a lead-acid type, you can measure the specific gravity of the electrolyte inside the battery using a hydrometer. A fully charged battery will have a specific gravity of around 1.265 – 1.280. If the reading is low, it may indicate that one or more cells are faulty. 6. Perform a Battery Health Check (Advanced) Use a Battery Tester: There are advanced battery testers that can measure the internal resistance, capacity, and health of the battery. These testers usually simulate various load conditions and measure how well the battery performs. Internal Resistance: A higher internal resistance indicates aging and reduced capacity. A proper battery tester will show you this resistance reading, which helps in assessing the battery's remaining life. 7. Monitor for Temperature Batteries can heat up during charging and discharging. Check for unusual temperature rises that may indicate internal problems. Excessive heat can degrade battery life and may signal an issue with the battery or the charging system. Signs of a Failing Battery: Rapid Voltage Drop: If the voltage quickly drops under load, the battery is likely deteriorating. Short Runtime: If the battery runs out of charge much faster than expected, it could mean it's near the end of its life. Inconsistent Voltage Readings: Large fluctuations in voltage readings, especially when under load, can indicate a failing battery. Physical Damage: Swelling, leaks, or any visible damage to the battery indicates that it needs to be replaced. Battery Maintenance Tips: Regular Charging: Avoid deep discharges and always keep the battery charged. Environmental Conditions: Keep the battery in a cool, dry place to avoid overheating or damage due to extreme temperatures. Periodic Tests: Test the battery every 3-6 months to assess its health and ensure it’s functioning properly. Use the Right Charger: Always use the manufacturer's recommended charger to prevent overcharging or undercharging. Conclusion: Battery testing is critical for ensuring that your Powerstack battery continues to perform optimally. Regular testing helps in identifying potential problems early and maintaining the battery’s health. Always follow the manufacturer’s instructions and consult with a professional if you're unsure about the testing process.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
AMARON QUANTA TUBULAR BATTERY

The Amaron C10 150AH Quanta Tubular Battery is designed for inverter applications and features the following specifications: Capacity: 150 Ah Voltage: 12 V Type: Tubular Protection: Over temperature, deep discharge, and short circuit Backup Time: Approximately 2 hours This battery is built for high performance and reliability, making it suitable for various power backup needs. Key Features of Amaron C10 150AH Quanta Tubular Battery Construction: Extra thick plates for enhanced longevity Maintenance: Low maintenance requirements due to special alloy composition Charge Acceptance: Excellent charge acceptance, ideal for frequent power cuts Level Indicators: Easy maintenance with built-in level indicators Power Cut Resilience: Designed to withstand frequent and prolonged power outages Specifications Brand: Amaron Model: C10 Voltage: 12V DC Capacity: 150Ah Type of Battery: Tall Tubular Inverter Compatibility: Supports all brands and types of inverters Factory Charged: Yes Warranty: 48 months (36 months replacement and 12 months pro-rata) This battery is an excellent choice for users looking for a reliable and efficient power backup solution, particularly in areas with frequent power interruptions.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
ALL TYPES UPS & BATTERIES AMC

An Annual Maintenance Contract (AMC) for UPS systems typically includes routine maintenance, repair services, and emergency support to ensure optimal performance. It covers inspections, battery maintenance, and high-priority assistance during breakdowns, helping to extend the lifespan of your UPS and batteries. For more specific details, you can refer to the links provided in the search results. UPS AMC Services Overview: Purpose of AMC: The AMC is designed to provide comprehensive support for UPS systems, ensuring they operate efficiently and reliably. This includes regular maintenance, emergency repairs, and technical assistance. Key Components of AMC: Routine Maintenance: Regular inspections and servicing to prevent issues before they arise. Repair Services: Quick response to any failures or malfunctions, minimizing downtime. Emergency Support: 24/7 assistance to address urgent issues. Types of AMC Plans: Platinum Plan: Covers all spare parts during maintenance, excluding natural calamities. High-priority assistance during breakdowns. Regular preventive maintenance and detailed reports with recommendations. Gold Plan: Similar to the Platinum plan but does not include standby units. Focuses on critical equipment maintenance. Silver Plan: Basic support with engineers and technical assistance only. Maintenance Schedule: Monthly Checks: Visual inspections of batteries and connections. Measurement of ambient temperature and humidity. Cleaning of the UPS environment. Quarterly Checks: Voltage measurement of each battery cell. Conductance testing for battery health. Yearly Checks: Torque measurement of all connections. Testing of interconnecting cable resistance. Importance of Battery Maintenance: Regular maintenance is crucial as battery failures account for a significant percentage of UPS failures. Environmental conditions can greatly affect battery life, with temperature fluctuations leading to reduced performance. Contact Information: For inquiries or to set up an AMC, you can reach out via: Email: info@universalpower.co.in Phone: 8744823336

Send Message
product image
UPS

APC offers a range of UPS (Uninterruptible Power Supply) systems, with the Smart-UPS series being particularly popular for providing reliable power protection. Here are some key specifications and details about the APC Smart-UPS models: General Specifications: Types: Line Interactive and On-Line models - Input Voltage: Typically 120V or 230V depending on the model Output Voltage: Pure sine wave output for compatibility with sensitive equipment Form Factor: Available in tower and rack-mount configurations Key Models: 1. APC Smart-UPS C Series: Ideal For: Small and medium businesses Features: Pure sine wave output LCD status display for real-time monitoring Multiple status indicators with load and battery bar graphs Configurable for tower or rack installation Models: SMC1000: 1000VA/670W SMC1500: 1500VA/1000W 2. APC Smart-UPS SMT Series: Features: Multi-function LCD screen DB-9, RS-232, Smart-Slot, and USB interface ports Extended runtime options with additional battery packs Models: SMT750: 750VA/500W SMT1000: 1000VA/670W SMT1500: 1500VA/1000W SMT2200: 2200VA/1980W 3. APC Smart-UPS SMX Series: Features: Similar to SMT series but with scalable runtime Extended run internal batteries Models: SMX750: 750VA/600W SMX1000: 1000VA/800W Key Features Across Models: Pure Sine Wave Output: Ensures compatibility with active PFC servers and sensitive electronics. LCD Display: Provides essential UPS status information at a glance. Multiple Output Receptacles: Varies by model, typically includes multiple 5-15R and 5-20R outlets. SmartConnect: Some models offer cloud monitoring capabilities for remote management. Applications: Data Centers: Protects critical servers and networking equipment. Telecommunications: Ensures reliable power for communication systems. Industrial Applications: Supports machinery and equipment during power interruptions. Advantages: Reliable Power Protection: Safeguards against power disturbances and outages. User -Friendly Management: Easy to monitor and manage through LCD displays and software. Versatile Installation Options: Suitable for various environments and configurations. APC UPS systems are designed to provide robust power protection and management solutions for a wide range of applications, ensuring that critical systems remain operational during power disruptions.

Send Message
product image
4 kva ups

The Luminous Cruze+ 4kVA is a high-performance online UPS that provides uninterrupted power for residential, commercial, and IT applications. Being an online UPS, it offers continuous, stable power with zero transfer time, making it ideal for sensitive equipment such as computers, servers, medical devices, and industrial systems. Key Features of Luminous Cruze+ 4kVA UPS Online Double-Conversion Technology: The Cruze+ 4kVA uses true online double-conversion technology, which ensures that your devices get clean, continuous, and regulated power without interruptions. In case of any fluctuations in the input voltage, the UPS immediately corrects it and ensures stable output voltage. Pure Sine Wave Output: The UPS provides pure sine wave output, which is ideal for sensitive devices, as it ensures minimal distortion and avoids any damage to electronic equipment, unlike square wave UPS systems that can harm certain types of equipment. High Efficiency: With a high conversion efficiency, the Cruze+ 4kVA reduces energy consumption and operational costs. This makes it not only a reliable backup solution but also energy-efficient. Wide Input Voltage Range: The Cruze+ UPS is designed to handle a wide input voltage range, which ensures that the system performs well even in areas with frequent voltage fluctuations, thereby reducing wear and tear on both the UPS and connected devices. Long Battery Life: Equipped with advanced battery management features, this UPS helps in optimizing the battery life, offering extended service periods even with frequent use. LCD/LED Display: The LCD display shows real-time status of the UPS, including input/output voltage, battery charge status, load percentage, and any faults. The LED indicators make it easier to monitor and understand the operational status at a glance. Battery Charging: The Cruze+ 4kVA UPS can handle multiple battery types, including lead-acid and VRLA batteries. It is equipped with an intelligent charging system that ensures batteries are charged efficiently without overcharging. Overload and Short Circuit Protection: Provides overload protection and short-circuit protection, ensuring that the system is safe from potential damage during power surges or faults. Battery Bank Options: The Cruze+ 4kVA is typically paired with a separate battery bank that provides the backup power. This can include Exide tubular batteries or Luminous batteries for optimal performance. Applications Residential: For powering sensitive equipment like computers, medical devices, and other electronics. Commercial: Protects servers, networking equipment, and office devices. Industrial: Suitable for critical industrial machines, automation systems, and control panels. Technical Specifications Capacity: 4kVA (4000 VA) Input Voltage: 140V - 300V (Wide input voltage range) Output Voltage: 220V / 230V (Pure sine wave) Output Frequency: 50 Hz ± 0.2 Hz Battery Charging Current: Adjustable (Typically 5-10A) Battery Type: Compatible with VRLA, Lead-Acid, and Tubular Batteries Backup Time: Depends on the battery capacity (typically, it can provide backup for 2-4 hours depending on the load and battery bank size). Dimensions (LxWxH): 465mm x 310mm x 115mm Weight: Around 15-18 kg (excluding battery) Warranty: 2 years on the UPS (can vary based on the model or region)

Send Message

Still searching for
visual indicators?