Noida
+918076792323

'1 6 kw output'

Items tagged with '1 6 kw output'

product image
10 kW solar system installed at M3M

Universal Power team has installed a 10 kW solar system 18 panel at M3M Key Details of the Installation: Solar System Size: 10 kW refers to the capacity of the solar system. This means the system is designed to generate up to 10 kilowatts (kW) of power under optimal sunlight conditions. Number of Panels: 18 solar panels have been installed. To estimate the power output of each panel, we can divide the system\'s total capacity by the number of panels. 10 kW / 18 panels = approximately 555 watts per panel. This indicates that each panel is likely rated around 555W, which is a common wattage for high-efficiency solar panels used in residential and commercial systems. Location – M3M: M3M could be a residential complex, office building, or another commercial facility. Without more specific information, M3M could refer to the area or project where the installation took place. If it’s a large-scale installation, such as for an office or commercial building, the solar panels are likely being used to reduce energy costs and carbon footprint. Energy Production: The energy output of the system will depend on several factors, including the amount of sunlight received, panel orientation, and local weather conditions. In an area with good sunlight, a 10 kW system could produce roughly 40-50 kWh per day on average, depending on the solar irradiance and hours of sunlight in that region. Over a year, this could amount to around 14, 600 to 18, 250 kWh of electricity. Purpose: The solar power system could be installed for various reasons: To reduce energy bills by using clean solar energy. To support sustainability goals, reduce carbon emissions, and make the building or facility more energy-efficient. To provide backup power or support the grid, especially in commercial or industrial settings. Benefits of a 10 kW Solar System: Reduced Electricity Costs: By producing energy from the sun, the system reduces reliance on grid power, thus lowering electricity bills over time. Environmental Impact: The system helps reduce carbon footprints by utilizing renewable energy instead of fossil fuels. Increased Property Value: Properties with solar installations are often valued higher due to the long-term savings on energy costs. Government Incentives: Depending on the region, there may be tax credits, subsidies, or incentives available for installing solar energy systems.

Send Message
product image
10 kW solar system installed at Parashuram Eye Hospital

10 kW solar Universal Power team has installed a 10 kW solar system at Parashuram Eye Hospital. Key Details of the 10 kW Solar System Installation: Solar Power Generation: A 10 kW system typically generates about 40-50 kWh per day, depending on the location and weather conditions. This translates to 14,600 to 18,250 kWh annually, which will help the hospital meet a significant portion of its energy needs. System Components: Solar Panels: Around 25-30 panels, each with a capacity of 330W-400W. Inverter: A 10 kW inverter is used to convert the DC electricity from the panels into AC electricity for hospital use. Mounting System: Panels are mounted on the roof or ground depending on the hospital's infrastructure. Grid Connection: The system is connected to the grid, allowing the hospital to export excess energy to the grid through net metering. Benefits for Parashuram Eye Hospital: Cost Reduction: The solar system will reduce the hospital's dependence on grid electricity, leading to lower monthly electricity bills. Sustainability: The hospital will be contributing to environmental sustainability by utilizing renewable energy, which helps reduce its carbon footprint. Energy Independence: The system ensures a reliable power source, especially during peak hours or grid outages. Maintenance: Solar panels require minimal maintenance, with periodic cleaning to ensure maximum efficiency. Lifespan: Solar panels typically last 25-30 years, and the inverter may need replacement after 10-15 years. Conclusion: The installation of a 10 kW on-grid solar power system at Parashuram Eye Hospital by Universal Power Team will provide long-term benefits in terms of cost savings, energy independence, and environmental impact. It’s an excellent step towards sustainable energy usage for the hospital. If you need more specific details about this installation, it would be best to contact Universal Power Team or the hospital directly.

Send Message
product image
AMARON QUANTA 12V 46Ah BATTERY

The AMARON 12V 46Ah battery is a reliable sealed lead-acid battery designed for various applications, including automotive and renewable energy systems. It typically features a nominal voltage of 12V, a capacity of 46Ah, and is known for its durability, low maintenance, and ability to perform well in diverse environmental conditions. Product Overview Type: Sealed Lead Acid (SLA) Battery Nominal Voltage: 12V Capacity: 46Ah Weight: Approximately 12-13 kg (varies by model) Dimensions: Typically around 9.1 x 5.4 x 8.5 inches (L x W x H) Key Features Durability: Designed to withstand harsh conditions and vibrations. Long service life with proper maintenance. Maintenance: Low maintenance requirements; sealed design prevents electrolyte loss. Requires periodic checks for optimal performance. Performance: Excellent deep cycle capabilities, suitable for applications requiring sustained power. Good discharge characteristics, providing reliable power output. Applications Automotive: Ideal for use in cars, trucks, and other vehicles. Suitable for starting, lighting, and ignition (SLI) applications. Renewable Energy: Can be used in solar energy systems for energy storage. Effective in off-grid applications and backup power systems. Warranty and Standards Warranty: Typically comes with a warranty period of 12-18 months, depending on the retailer. Certifications: Complies with international safety and performance standards. Charging and Maintenance Charging Voltage: Recommended charging voltage is around 14.4V to 14.8V. Charging Method: Can be charged using standard lead-acid battery chargers. Avoid overcharging to extend battery life. Environmental Considerations Operating Temperature: Performs well in a wide range of temperatures, typically from -20°C to +50°C. Ensure proper ventilation during charging to prevent gas buildup. This battery is a versatile choice for users looking for a dependable power source across various applications.

Send Message
product image
6 kva ups

The Vertiv 6 kVA UPS models, such as the Liebert GXT5 and Liebert GXT MTX+, offer robust power protection for critical equipment. Here are the key specifications and details: Vertiv Liebert GXT5 6 kVA/6 kW Model: Liebert GXT5 Capacity: 6 kVA / 6 kW Input Voltage: 208/120V Output Power Factor: 1.0 (Unity) Form Factor: Rack/Tower Dimensions: Depth: 25.6 inches Rack Height: 4U Weight: Approximately 125.60 lbs Backup/Run Time: Half Load: 9.50 minutes Full Load: 3.50 minutes Transfer Time: 0 ns (no break) Receptacle Type: Hardwired Bypass Switch: Automatic & Manual; Internal Emergency Power OFF: Yes Audible Noise: Less than 55 dBA at 1 meter Vertiv Liebert GXT MTX+ 6 kVA Model: Liebert GXT MTX+ Output Power Factor: 0.8 Input Voltage Range: 110 — 300 Vac Charging Design: 4 Stage Extendable Charging for optimized battery performance Adjustable Battery Charging Current: 1/2/4/6 Amps based on battery capacity Compact Design: Best-in-class online UPS system General Features Type: Online Double Conversion UPS Protection: Protects against outages and all types of power disturbances Applications: Suitable for centralized and edge locations, ideal for critical equipment These UPS systems are designed to ensure reliable power supply and protect sensitive electronic equipment from power disturbances, making them essential for data centers, telecommunications, and other critical applications.

Send Message
product image
ups

Vertiv offers several models of 10kVA Uninterruptible Power Supplies (UPS) designed for critical power applications. Here’s a comprehensive overview of the key models and their features: Key Models: 1. Vertiv Liebert GXT5 UPS: Power Rating: 10kVA / 10kW Input/Output Voltage: 230V in / 230V out, single-phase Technology: Online double conversion for continuous power conditioning Power Factor: Unity power factor (1.0) for efficient load management Form Factor: Tower/rack mount Features: Remote Monitoring: Built-in Vertiv RDU101 communications card for remote monitoring and management Software Integration: Compatible with Vertiv Power Insight software for consolidated monitoring of up to 100 UPS units Scalable Runtime: Options for external battery cabinets to extend runtime during outages Display: Intuitive gravity sensing full-color LCD display for easy status monitoring Energy Efficiency: ENERGY STAR 2.0 certified for reduced energy consumption Applications: Data Centers: Protects critical IT infrastructure from power disturbances Healthcare: Ensures reliable power for medical equipment Telecommunications: Supports network reliability during outages Industrial: Safeguards machinery and sensitive equipment Technical Specifications: Input Connection Types: IEC 320 EN 60320 C13, IEC 60320 C19 Output Connection Types: 4 x IEC 60320 C19 Operating Environment: Designed for both centralized and edge computing applications Advantages: High Efficiency: Reduces operational costs with high power efficiency Robust Protection: Protects against all types of power disturbances, extending battery life Flexible Deployment: Suitable for various installation environments, including rack and tower configurations Vertiv\'s 10kVA UPS solutions are engineered to provide reliable power protection and management for critical applications, ensuring operational continuity during power interruptions.

Send Message
product image
6 KVA POWERBANK

The Vertiv 6kVA PowerBank UPS is typically part of Vertiv's On-Line or Line-Interactive power protection solutions that integrate battery backup systems designed to maintain a continuous supply of power in the event of an outage. These UPS systems are ideal for applications where consistent power quality and uptime are critical, such as for medium to large businesses, IT infrastructure, and high-demand environments like data centers. Although "PowerBank" is a brand name or marketing term used by Vertiv for specific models of UPS systems (often focused on extended battery runtimes or integrated external batteries), detailed product specifications and the exact model can vary. Below is a general overview of the Vertiv 6kVA PowerBank UPS based on the series features typically associated with Vertiv's offerings. Key Features and Specifications: 1. Topology: Double Conversion On-Line: Provides the highest level of protection by continuously filtering and conditioning the incoming utility power. It delivers pure sinewave output, making it suitable for sensitive equipment that requires high-quality power. The On-Line topology ensures zero transfer time in case of power failure because the UPS system is always supplying power from the inverter. 2. Power Rating: 6kVA / 6000VA (Provides backup for medium-sized systems or higher power applications like small-to-medium server rooms, network systems, and critical equipment). 3. Output Power: Output Power: 4.8 kW to 5.4 kW (depending on load and configuration) 4. Input and Output Specifications: Input Voltage: 110V - 300V, wide input range for handling fluctuations without switching to battery mode. Output Voltage: 230V ± 2% (standard in most countries) 5. Waveform Type: Pure Sinewave Output: Ensures that the connected equipment receives a smooth and continuous power supply without the distortions found in some lower-quality UPS systems. 6. Battery Configuration: Battery Type: Typically Sealed Lead-Acid (SLA) or Valve-Regulated Lead-Acid (VRLA) batteries. Battery Capacity: Typically, 12V batteries with 18Ah, 24Ah, or higher capacities. The system may include external battery modules (Battery Banks) for extended runtime, making it suitable for larger power demands and longer backup times. External Battery Packs: Some models support additional external battery cabinets, which allow the UPS to run longer during extended outages. This is especially important for environments where power failures may last for an extended period. 7. Charging Time: Typically, the system will fully recharge in around 4-6 hours, depending on battery size and environmental conditions. 8. Backup Time (Runtime): The backup time can range from 20 minutes to several hours, depending on the load. For example, a 50% load (about 3 kVA or 3000W) will generally offer a longer runtime. A full load of 6kVA will typically provide 10-15 minutes of backup time. If the UPS is configured with external battery packs, the runtime can be extended for much longer periods, making it ideal for critical systems that require extended protection during power outages. 9. Cooling System: The UPS is equipped with fan-assisted cooling to ensure efficient heat dissipation and prevent overheating during extended use. 10. Display and Monitoring: LCD Display: Displays real-time information about UPS status, battery health, load capacity, input/output voltages, battery runtime, and other important parameters. Audible Alarms: Alerts for conditions such as low battery, overload, power failure, and system faults. Smart Battery Management: Ensures optimal battery health and extends the lifespan of the UPS. 11. Connectivity and Interfaces: USB/Serial Ports: For communication with a connected computer or server for monitoring and management. SNMP Slots: Some models may offer SNMP (Simple Network Management Protocol) support for remote monitoring and management via networked devices. Dry Contact Interface: Allows integration with building management or alert systems. Optional Software: Available for automated shutdown in the event of prolonged power outages, and event logging. 12. Form Factor: Tower or Rackmount (depending on the specific model and user preferences). Some models are available in rackmount configurations for server rooms and data centers, while others are more suitable for a tower setup. 13. Additional Features: Overload Protection: Safeguards against exceeding the UPS's rated capacity. Short-Circuit Protection: Provides defense against electrical faults. Automatic Voltage Regulation (AVR): Ensures that the UPS compensates for voltage fluctuations (e.g., brownouts or overvoltages) without resorting to battery backup.

Send Message
product image
Amaron Quanta 12V 42ah Smf Batteries With Vertiv 2Kva Ups

The Amaron 12V 42Ah battery is commonly used in various uninterruptible power supply (UPS) systems, including those from Vertiv. When paired with a Vertiv 2 kVA UPS, it provides reliable backup power for critical applications. Below are the details regarding both the Amaron battery and its application in a Vertiv 2 kVA UPS system. Amaron 12V 42Ah Battery Type: Sealed Lead Acid (SLA) battery, specifically designed for deep cycle applications. Voltage: Nominal Voltage: 12 Volts. Capacity: Ah Rating: 42 Ampere-hours (Ah), which indicates the battery's capacity to deliver a specific current for a certain period. Dimensions: Size: Typically around 9.5 x 5.5 x 8.5 inches (L x W x H), but this can vary by manufacturer. Weight: Approximately 30-35 lbs (13-16 kg), depending on the specific model and manufacturer. Construction: Maintenance-Free: The sealed design prevents leakage and reduces maintenance requirements. Durability: Designed to withstand vibrations and shocks, making it suitable for various environments. Discharge Characteristics: Cycle Life: Can typically provide around 300-500 cycles at 100% discharge, depending on usage and maintenance. Operating Temperature: Generally operates efficiently within a temperature range of -15°C to 50°C (5°F to 122°F). Vertiv 2 kVA UPS Power Rating: Capacity: 2 kVA (2000 VA) / typically around 1.6 kW output, depending on the power factor. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring maximum protection for connected equipment. Input Specifications: Input Voltage: Typically accepts 110-240 VAC. Input Frequency: 50/60 Hz (auto-sensing). Output Specifications: Output Voltage: Configurable, typically 220/230/240 VAC. Output Connections: Multiple IEC or NEMA outlets for connecting devices. Battery Compatibility: The 2 kVA UPS can be paired with multiple 12V batteries (like the Amaron 12V 42Ah) in series or parallel configurations to achieve the desired runtime and capacity. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 for management and monitoring. Some models may have SNMP options. Physical Dimensions: Size: Generally around 3U to 5U in height, depending on the specific model. Weight: Approximately 50-70 lbs (22-32 kg) for the UPS alone, excluding batteries. Applications The combination of the Amaron 12V 42Ah battery with a Vertiv 2 kVA UPS is ideal for protecting critical IT equipment, networking devices, and servers in small to medium-sized data centers, server rooms, and telecommunications environments. Summary The Amaron 12V 42Ah battery is a reliable choice for use in a Vertiv 2 kVA UPS, providing the necessary backup power to maintain operations during outages. The UPS offers advanced features like online double-conversion technology and real-time monitoring, ensuring that sensitive equipment remains protected. For the most accurate and specific details, including installation, configuration, and warranty information, it's advisable to refer to the official documentation from Vertiv and Amaron or consult with their respective representatives.

Send Message
product image
Vertiv 6 Kva Ups

The Vertiv Liebert GXT5-6000RT120 is a popular 6 kVA online uninterruptible power supply (UPS) designed for critical applications in data centers and IT environments. Below are the key specifications and features of the Vertiv 6 kVA UPS: Key Features Form Factor: Rack-mountable (typically 3U) or tower configuration, depending on the model. Power Rating: Capacity: 6 kVA (6000 VA) / 5.4 kW output. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 120 VAC (or 220/230/240 VAC depending on configuration). Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with a hardwired connection or NEMA L6-30P plug. Output Specifications: Output Voltage: Configurable 120/208/230/240 VAC. Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple NEMA outlets or terminal block connections for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries providing backup power during outages. Battery Runtime: Varies based on load; typically offers several minutes to hours of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often exceeding 95% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB, RS-232, and optional SNMP card for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 5.2 inches (3U) in height, with width and depth depending on the specific model. Weight: Typically around 100 lbs (45 kg), depending on the battery configuration. Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT5-6000RT120 is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message
product image
Vertiv 1 kva Ups

The Vertiv Liebert GXT RT+ 1 kVA is a highly regarded rack-mountable uninterruptible power supply (UPS) designed for critical applications, including data centers and IT environments. Below are the key details and specifications for the Liebert GXT RT+ 1 kVA model: Key Features Form Factor: Rack-mountable design, typically in a 2U form factor, allowing for easy integration into standard server racks. Power Rating: Capacity: 1 kVA (1000 VA) / 800 W output. Topology: On-Line Double-Conversion: Provides continuous power and zero transfer time to battery during power disturbances, ensuring the highest level of protection for sensitive equipment. Input Specifications: Input Voltage: 100-240 VAC, auto-sensing. Input Frequency: 50/60 Hz (auto-sensing). Input Connection: Typically comes with IEC C14 inlet. Output Specifications: Output Voltage: 220/230/240 VAC (configurable). Output Frequency: 50/60 Hz (synchronized to mains). Output Connections: Multiple IEC outlets for connecting devices. Battery Specifications: Internal Batteries: Sealed lead-acid batteries that provide backup power during outages. Battery Runtime: Varies based on load; typically provides several minutes of backup for critical devices. Recharge Time: Generally within 4-6 hours to reach full charge after a complete discharge. Efficiency: High efficiency ratings, often above 90% in online mode, reducing energy costs and heat output. Cooling: Internal cooling fans that activate based on temperature and load conditions to maintain optimal operating temperatures. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 ports for management and monitoring. SNMP card options may be available for network management. Software: Compatible with various UPS management software for monitoring and control. Physical Dimensions: Size: Approximately 3.5 inches (2U) in height, with width and depth depending on the specific model. Weight: Varies based on battery configuration but generally around 20-30 lbs (9-14 kg). Environmental Specifications: Operating Temperature: Typically ranges from 0°C to 40°C (32°F to 104°F). Humidity: 0% to 95% non-condensing. Safety and Certifications: Complies with various safety and performance standards, such as UL, CE, and others, ensuring reliability and safety in operation. Applications Ideal for protecting critical IT equipment, networking devices, telecommunications equipment, and small servers in data centers and edge computing environments. Summary The Vertiv Liebert GXT RT+ 1 kVA UPS is designed to provide reliable power protection for sensitive equipment in a compact, rack-mountable format. With its online double-conversion technology, it ensures continuous power supply and high efficiency, making it suitable for various applications requiring high availability and reliability.

Send Message