Noida
+918076792323

'4 batteries batteries'

Items tagged with '4 batteries batteries'

product image
Amaron Quanta 12V 42ah Smf Batteries With Vertiv 2Kva Ups

The Amaron 12V 42Ah battery is commonly used in various uninterruptible power supply (UPS) systems, including those from Vertiv. When paired with a Vertiv 2 kVA UPS, it provides reliable backup power for critical applications. Below are the details regarding both the Amaron battery and its application in a Vertiv 2 kVA UPS system. Amaron 12V 42Ah Battery Type: Sealed Lead Acid (SLA) battery, specifically designed for deep cycle applications. Voltage: Nominal Voltage: 12 Volts. Capacity: Ah Rating: 42 Ampere-hours (Ah), which indicates the battery's capacity to deliver a specific current for a certain period. Dimensions: Size: Typically around 9.5 x 5.5 x 8.5 inches (L x W x H), but this can vary by manufacturer. Weight: Approximately 30-35 lbs (13-16 kg), depending on the specific model and manufacturer. Construction: Maintenance-Free: The sealed design prevents leakage and reduces maintenance requirements. Durability: Designed to withstand vibrations and shocks, making it suitable for various environments. Discharge Characteristics: Cycle Life: Can typically provide around 300-500 cycles at 100% discharge, depending on usage and maintenance. Operating Temperature: Generally operates efficiently within a temperature range of -15°C to 50°C (5°F to 122°F). Vertiv 2 kVA UPS Power Rating: Capacity: 2 kVA (2000 VA) / typically around 1.6 kW output, depending on the power factor. Topology: On-Line Double-Conversion: Provides continuous power with zero transfer time, ensuring maximum protection for connected equipment. Input Specifications: Input Voltage: Typically accepts 110-240 VAC. Input Frequency: 50/60 Hz (auto-sensing). Output Specifications: Output Voltage: Configurable, typically 220/230/240 VAC. Output Connections: Multiple IEC or NEMA outlets for connecting devices. Battery Compatibility: The 2 kVA UPS can be paired with multiple 12V batteries (like the Amaron 12V 42Ah) in series or parallel configurations to achieve the desired runtime and capacity. Management and Monitoring: LCD Display: Provides real-time information on UPS status, including input/output voltage, load level, battery status, and alarms. Communication Ports: Typically includes USB and RS-232 for management and monitoring. Some models may have SNMP options. Physical Dimensions: Size: Generally around 3U to 5U in height, depending on the specific model. Weight: Approximately 50-70 lbs (22-32 kg) for the UPS alone, excluding batteries. Applications The combination of the Amaron 12V 42Ah battery with a Vertiv 2 kVA UPS is ideal for protecting critical IT equipment, networking devices, and servers in small to medium-sized data centers, server rooms, and telecommunications environments. Summary The Amaron 12V 42Ah battery is a reliable choice for use in a Vertiv 2 kVA UPS, providing the necessary backup power to maintain operations during outages. The UPS offers advanced features like online double-conversion technology and real-time monitoring, ensuring that sensitive equipment remains protected. For the most accurate and specific details, including installation, configuration, and warranty information, it's advisable to refer to the official documentation from Vertiv and Amaron or consult with their respective representatives.

Send Message
product image
Amaron Quanta 12v 42Ah Battery

The Amaron Quanta 42Ah (Ampere-hour) battery is a high-performance, maintenance-free lead-acid battery designed for use in UPS systems, inverters, and solar energy storage applications. It provides reliable power backup for a range of devices, especially in environments where power stability and uninterrupted performance are crucial. Key Features of Amaron Quanta 42Ah Battery: Capacity: 42Ah (Ampere-hour) – This means the battery can provide 42 amps of current for one hour, or a proportionally smaller amount of current over a longer period of time, depending on the load. Technology: Maintenance-Free: The Amaron Quanta series batteries are sealed lead-acid batteries (SLA) that do not require frequent maintenance or water refilling, making them very convenient and hassle-free. High Performance: Designed for high efficiency, the Amaron Quanta 42Ah battery offers good charge retention, ensuring long-lasting backup for your UPS or inverter. Deep Cycle Battery: This is a deep-cycle battery, meaning it is designed to handle deeper discharges compared to regular car batteries. It is well-suited for applications where the battery may be discharged and recharged frequently. Durability: Long Shelf Life: Amaron Quanta batteries have a good shelf life and can perform well over extended periods when properly stored. High-Temperature Tolerance: They are built to withstand a wide range of temperatures, making them suitable for varying environmental conditions. Design: Compact and Reliable: The battery is designed to be compact, reliable, and easy to install, especially in environments where space is a concern. Vibration Resistant: The battery is engineered to resist damage from vibration, ensuring its durability in various settings. Safety Features: Flame-Retardant Materials: The Amaron Quanta 42Ah battery uses flame-retardant materials to ensure safety in case of battery malfunction. Leak-Proof: Being a sealed battery, it minimizes the risk of acid leakage, which adds an extra layer of safety. Application Areas: UPS Systems: Provides backup power to computers, servers, and networking equipment. Inverter Systems: Used in residential and small commercial applications to ensure uninterrupted power during outages. Solar Energy Storage: Can be used as part of a solar energy storage system to store excess energy generated during the day for use at night. Warranty: The Amaron Quanta batteries often come with a 2-year warranty, depending on the region and purchase conditions. It is recommended to check with the seller or manufacturer for specific warranty details. General Specifications: Voltage: 12V (standard for most UPS and inverter batteries). Capacity: 42Ah. Type: Sealed Lead-Acid (SLA) or AGM (Absorbent Glass Mat). Charging Voltage: Typically around 14.4 to 15.0V for 12V batteries. Nominal Voltage: 12V. Dimensions: Typically around length: 200mm, width: 165mm, height: 175mm (varies slightly depending on specific model). Weight: Approximately 12-14 kg. Maintenance Tips for the Amaron Quanta 42Ah Battery: Regular Charging: Always ensure that the battery is fully charged and avoid discharging it completely to extend its lifespan. Storage: If you’re storing the battery for an extended period, make sure to store it in a cool, dry place and check the charge level periodically. Clean the Terminals: Ensure the terminals are clean and free of corrosion. Clean the terminals with a mixture of baking soda and water if needed. Avoid Overcharging: Always use a compatible charger to avoid overcharging the battery, which could damage it. Check for Leakage: While the battery is sealed, it's a good idea to check for any leaks, especially if the battery has been in use for a long time or is showing signs of wear. Battery Testing: To check the health of the Amaron Quanta 42Ah battery, you can follow these steps: Voltage Check: Use a voltmeter to check the voltage. A fully charged 12V battery should show between 12.6V to 12.8V. Load Test: Under load, if the voltage drops rapidly below 10.5V for a 12V battery, it may be a sign of degradation. Capacity Test: If your application requires it, you can perform a discharge test to check the battery's capacity. This involves discharging the battery with a known load and measuring how long it takes for the voltage to drop below a certain threshold. Conclusion: The Amaron Quanta 42Ah battery is a reliable and durable option for providing backup power in various applications, including UPS systems, inverters, and solar power storage. It offers maintenance-free operation, a long service life, and excellent temperature tolerance. By regularly maintaining and testing the battery, you can ensure that it continues to perform effectively over time.

Send Message
product image
Maintenance Tips for UPS Systems and Batteries​

Maintaining your Uninterruptible Power Supply (UPS) system and its batteries is crucial for ensuring reliable performance and extending their lifespan. Here are some essential maintenance tips: 1. Regular Inspection Visual Checks: Inspect the UPS and batteries for any signs of physical damage, leaks, or corrosion. Connections: Ensure that all connections are secure and free from dust and corrosion. 2. Battery Maintenance Battery Testing: Regularly test the batteries for capacity and performance. Use a battery tester to check voltage and load. Clean Terminals: Keep battery terminals clean and free from corrosion. Use a mixture of baking soda and water to clean any corrosion, and ensure terminals are dry before reconnecting. Check Electrolyte Levels: For flooded lead-acid batteries, check the electrolyte levels regularly and top up with distilled water as needed. 3. Environmental Considerations Temperature Control: Keep the UPS and batteries in a cool, dry environment. High temperatures can reduce battery life significantly. Ventilation: Ensure proper ventilation around the UPS to prevent overheating. Avoid placing it in enclosed spaces without airflow. 4. Regular Testing Self-Test: Perform regular self-tests to ensure the UPS is functioning correctly. Most UPS systems have a built-in self-test feature. Load Testing: Conduct load tests periodically to ensure the UPS can handle the required load during a power outage. 5. Firmware and Software Updates Keep Software Updated: Regularly check for and install firmware updates for your UPS. This can improve performance and security. Monitoring Software: Use UPS monitoring software to track performance metrics and receive alerts for any issues. 6. Battery Replacement Follow Manufacturer Guidelines: Replace batteries according to the manufacturer\'s recommendations, typically every 3-5 years for lead-acid batteries. Dispose of Batteries Properly: Follow local regulations for the disposal of batteries to ensure environmental safety. 7. Load Management Avoid Overloading: Ensure that the total load connected to the UPS does not exceed its rated capacity. This can lead to overheating and reduced battery life. Balanced Load: Distribute the load evenly across all outlets to prevent any single outlet from being overloaded. 8. Documentation Keep Records: Maintain a log of maintenance activities, battery replacements, and any issues encountered. This can help in troubleshooting and planning future maintenance. 9. Professional Maintenance Schedule Professional Inspections: Consider having a qualified technician perform regular inspections and maintenance, especially for larger UPS systems. 10. User Training Educate Staff: Train staff on the proper use and maintenance of the UPS system, including how to respond in case of a power outage.

Send Message
product image
Exide Batteries

Exide batteries are known for their reliability and performance, catering to various applications including automotive and industrial use. They offer a range of products, including flat plate flooded lead acid batteries and tubular inverter batteries, designed to meet high standards and operate effectively in diverse conditions. Exide Battery Types Automotive Batteries: Designed for vehicles, ensuring reliable starting power and performance. Available in various models to suit different vehicle types. Xpress Range: Specially designed for the Indian environment, featuring a hybrid alloy system. Enhanced cycle life due to double-clad separation and unique rib-free separator profile. Quick recharge capabilities with a unique tree radial grid design. Maintenance-free with low water loss during high temperatures. Factory-charged and ready to use upon delivery. Key Features Durability: Special polypropylene container withstands severe operating conditions and vibrations. Safety: Micro-porous filter disc in vent openings to prevent acid fumes and spark propagation. Leak-resistant design with a side vented lid to minimize electrolyte leakage. User -Friendly: Magic eye feature for easy monitoring of charge state and electrolyte levels. Requires minimal maintenance, with topping up needed only once every six months. Warranty and Standards Warranty: Comes with a 42-month warranty, ensuring customer satisfaction and reliability. Compliance: Conforms to various standards including IS 14257-1995, JIS-D5301-1999, and IS7372-1995. Applications Energy Storage Solutions: Suitable for both transportation and stationary applications, providing efficient energy storage. Used in various sectors including automotive, industrial, and renewable energy systems.

Send Message
product image
All Types Of Ups & Batteries Repair And Maintenance Of Ups

Repair and maintenance of UPS (Uninterruptible Power Supply) systems and batteries are crucial for ensuring their reliability and longevity. Below is a comprehensive overview of the types of UPS systems, batteries, and the associated repair and maintenance practices. Types of UPS Systems Offline/Standby UPS: Description: Provides basic protection; switches to battery during a power outage. Maintenance: Regular battery checks and replacement every 3-5 years. Line-Interactive UPS: Description: Offers voltage regulation and battery backup; ideal for environments with frequent voltage fluctuations. Maintenance: Inspect and test the battery and inverter regularly; check for dust accumulation. Online Double-Conversion UPS: Description: Provides continuous power and isolates equipment from power issues. Maintenance: More complex; requires regular inspection of internal components, battery health checks, and firmware updates. Modular UPS: Description: Scalable systems that allow for adding or removing modules based on power needs. Maintenance: Regular checks on each module, ensuring proper connections and functionality. Types of Batteries Used in UPS Lead-Acid Batteries: Types: Sealed Lead Acid (SLA), Absorbent Glass Mat (AGM), Gel. Maintenance: Regularly check electrolyte levels (for non-sealed types), clean terminals, and test for capacity. Lithium-Ion Batteries: Description: Increasingly used due to longer life and lighter weight. Maintenance: Monitor battery management systems (BMS) for health and performance; check for firmware updates. Nickel-Cadmium (NiCd) Batteries: Description: Used in specific applications; known for durability. Maintenance: Regularly test for capacity and perform equalization charging. Repair and Maintenance Practices 1. Routine Inspections Visual Checks: Inspect for physical damage, corrosion, or loose connections. Environmental Conditions: Ensure the UPS and batteries are in a suitable environment (temperature, humidity). 2. Battery Maintenance Testing: Conduct regular load tests and capacity tests to assess battery health. Cleaning: Clean terminals and connections to prevent corrosion. Replacement: Replace batteries as per manufacturer recommendations (typically every 3-5 years for lead-acid). 3. UPS Maintenance Firmware Updates: Keep the UPS firmware updated for optimal performance. Component Checks: Inspect capacitors, fans, and other internal components for wear and tear. Cooling System: Ensure that cooling fans are operational and that vents are not blocked. 4. Emergency Procedures Testing: Regularly test the UPS under load conditions to ensure it functions correctly during an outage. Documentation: Maintain records of all maintenance activities, repairs, and battery replacements. 5. Professional Servicing Scheduled Maintenance: Engage professional services for comprehensive inspections and repairs, especially for complex systems like online UPS. Emergency Repairs: Have a plan in place for rapid response to UPS failures, including access to spare parts. Conclusion Regular maintenance and timely repairs of UPS systems and batteries are essential for ensuring uninterrupted power supply and protecting sensitive equipment. By following a structured maintenance schedule and engaging professional services when necessary, you can significantly extend the lifespan and reliability of your UPS systems and batteries. For specific service providers or detailed maintenance plans, consider reaching out to local UPS service companies or manufacturers for tailored solutions.

Send Message
product image
ALL TYPES UPS & BATTERIES AMC

An Annual Maintenance Contract (AMC) for UPS systems typically includes routine maintenance, repair services, and emergency support to ensure optimal performance. It covers inspections, battery maintenance, and high-priority assistance during breakdowns, helping to extend the lifespan of your UPS and batteries. For more specific details, you can refer to the links provided in the search results. UPS AMC Services Overview: Purpose of AMC: The AMC is designed to provide comprehensive support for UPS systems, ensuring they operate efficiently and reliably. This includes regular maintenance, emergency repairs, and technical assistance. Key Components of AMC: Routine Maintenance: Regular inspections and servicing to prevent issues before they arise. Repair Services: Quick response to any failures or malfunctions, minimizing downtime. Emergency Support: 24/7 assistance to address urgent issues. Types of AMC Plans: Platinum Plan: Covers all spare parts during maintenance, excluding natural calamities. High-priority assistance during breakdowns. Regular preventive maintenance and detailed reports with recommendations. Gold Plan: Similar to the Platinum plan but does not include standby units. Focuses on critical equipment maintenance. Silver Plan: Basic support with engineers and technical assistance only. Maintenance Schedule: Monthly Checks: Visual inspections of batteries and connections. Measurement of ambient temperature and humidity. Cleaning of the UPS environment. Quarterly Checks: Voltage measurement of each battery cell. Conductance testing for battery health. Yearly Checks: Torque measurement of all connections. Testing of interconnecting cable resistance. Importance of Battery Maintenance: Regular maintenance is crucial as battery failures account for a significant percentage of UPS failures. Environmental conditions can greatly affect battery life, with temperature fluctuations leading to reduced performance. Contact Information: For inquiries or to set up an AMC, you can reach out via: Email: info@universalpower.co.in Phone: 8744823336

Send Message
product image
40kVA UPS

The Vertiv 40kVA UPS models, such as the Liebert ITA and EXS series, offer robust power protection for critical applications. They feature a power capacity of 40 kVA, double conversion technology, and options for both three-phase and single-phase outputs, ensuring reliable performance and flexibility in installation. Key Specifications: Power Capacity: 40 kVA (40 kW). Input Voltage Range: Typically 176 V AC - 288 V AC. Output Voltage: Configurable options, often 208V or 220V. Form Factor: Available in rack or tower configurations. Efficiency: High efficiency ratings, often exceeding 95%. Communication: Equipped with Vertiv IntelliSlot for SNMP, Modbus, or Relay communication. Battery Type: Generally uses lead-acid batteries with options for extended runtime. Applications: Ideal for data centers, telecommunications, and other critical infrastructure requiring uninterrupted power supply.

Send Message
product image
black hiway

Amaron Black Hiway batteries are known for their durability and performance, designed to meet the demands of various vehicles. Here’s a comprehensive overview of their features and specifications: Overview Type: Automotive batteries suitable for a range of vehicles. Technology: Advanced zero-maint enance technology for hassle-free operation. Design: Engineered for tropical climates, ensuring reliability in high temperatures. Key Specifications Capacity Options: Available in various capacities, including 80 AH, 120 AH, and 150 AH. Voltage: Standard voltage of 12 V across models. Cold Cranking Amps (CCA): High CCA ratings, such as 950 CCA for certain models, ensuring reliable starts in cold conditions. Warranty and Support Warranty Period: Typically ranges from 24 to 42 months, depending on the model. Example: 24 months full replacement + 18 months pro-rata for some models. Customer Support: Amaron provides extensive customer support for battery maintenance and inquiries. Performance Features Maintenance-Free: Designed to require no water topping up, reducing maintenance efforts. Vibration Resistance: Built to withstand harsh conditions and vibrations, enhancing longevity. High Heat Technology: Specifically designed to operate efficiently in high-temperature environments. Popular Models HC620D31R: Known for its premium quality and long life. HC180D04R: Offers a balance of performance and affordability. NT800E41R: Features a capacity of 120 AH with a total warranty of 42 months. NTX00D04R: A robust option with 150 AH capacity and high CCA. Conclusion Amaron Black Hiway batteries are a reliable choice for automotive needs, offering a combination of advanced technology, high performance, and minimal maintenance requirements, making them suitable for various driving conditions and vehicle types.

Send Message
product image
Battery

The Amaron Quanta 12V 46Ah battery is a reliable lead-acid battery designed for various applications, particularly in UPS systems. Here are the key specifications and details: Specifications: Voltage: 12V Capacity: 46Ah (Ampere-hours - Type: Sealed Maintenance-Free (SMF) Dimensions: Typically around 197mm x 165mm x 170mm (L x W x H) Weight: Approximately 13.5 kg Key Features: High Power Density: Ensures optimal use of space, making it suitable for installations with limited area. Quick Recharge: Lower internal resistance (IR) values allow for a 10% faster recharge time. Volumetric Energy Density: Requires 10% less space compared to conventional batteries. Long Life Cycle: Designed for extended service life, reducing the need for frequent replacements. Applications: Data Centers: Provides reliable backup power for critical systems. Process Industry: Supports operations that require uninterrupted power supply. Manufacturing Facilities: Ensures machinery and equipment remain operational during outages. Large Corporate Offices: Ideal for powering essential office equipment and systems. Advantages: Maintenance-Free: No need for regular maintenance, making it user-friendly. Robust Design: Built to withstand harsh conditions and provide consistent performance. Environmentally Friendly: Designed with eco-friendly materials and processes. The Amaron Quanta 12V 46Ah battery is an excellent choice for those seeking a dependable power source for various applications, particularly in environments where reliability and efficiency are paramount.

Send Message

Still searching for
4 batteries batteries?